Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "micro-CT" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Microstructure characterization by means of X-ray micro-CT and nanoindentation measurements
Autorzy:
Rajczakowska, M.
Stefaniuk, D.
Łydżba, D.
Powiązania:
https://bibliotekanauki.pl/articles/178547.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
micro-CT
nanoindentation
microstructure
composite
Opis:
The aim of this paper is to present an example of the material microstructure characterization with the use of X-ray micro-CT and nanoindentation measurements. Firstly, the current scope of application of the aforementioned techniques is provided within different fields of science. Then, background of each of the methods is presented. The methodology of X-ray micro-CT is described with the emphasis on the Beer’s law formulation. In addition, the basics of the nanoindentation technique are outlined and major formulas for the hardness and Young’s modulus calculation are given. Finally, example results for a concrete sample are presented. The microstructure of the selected material is firstly characterized in terms of geometry using the results from the microtomograhy measurements, e.g., porosity and attenuation profiles, pore and aggregate size distribution, shape factor of pores, etc. Next, the results of the nanoindentation tests are provided, namely the hardness and Young’s modulus versus the height of the sample. The influence of the number of tests and statistical analysis on the final results is underlined.
Źródło:
Studia Geotechnica et Mechanica; 2015, 37, 1; 75-84
0137-6365
2083-831X
Pojawia się w:
Studia Geotechnica et Mechanica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of Properties of Cast Metal Foams with Irregular Inner Structure
Autorzy:
Kroupová, I.
Lichý, P.
Ličev, L.
Hendrych, J.
Souček, K.
Powiązania:
https://bibliotekanauki.pl/articles/355316.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal foams
irregular structure
precursor
porosity
micro-CT
Opis:
Internal structure of metal foams is one of the most important factors that determine its mechanical properties. There exists a number of methods for studying the nature of the inner porous structure. Unfortunately most of these processes is destructive and therefore it is not possible to reuse the sample. From this point of view, as a suitable method seems to be the ability of using the so-called X-ray microtomography (also micro-CT). This is a non-destructive methodology used in a number of fields (industry, science, archaeology, medicine) for a description of the material distribution in the space (e.g. pores, fillers, defects, etc.). In principle, this technology works on different absorption of X-ray radiation by materials with changing proton number. The contribution was worked out in collaboration with experts from the Faculty of Electrical Engineering and Computer Science of the VŠB-Technical University of Ostrava and it is focused on the analysis of internal structure of the metal foam casting with irregular arrangement of internal pores by using micro-CT. The obtained data were evaluated in the commercial software VGStudio MAX 2.2 and in the FOTOMNG system. For the evaluation of these data a new specialized module was introduced in this system. Several methods of pre-processing the image was prepared for the measurement. This preliminary processing consists, for example, from a binary image thresholding for better diversity between the internal porosity and the material itself or functions for colour inversion.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1847-1851
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The ability of S.aureus to form biofilm on the Ti-6Al-7Nb scaffolds produced by Selective Laser Melting and subjected to the different types of surface modifications
Autorzy:
Szymczyk, P.
Junka, A.
Ziółkowski, G.
Smutnicka, D.
Bartoszewicz, M.
Chlebus, E.
Powiązania:
https://bibliotekanauki.pl/articles/306293.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
SLM
micro-CT
scaffolds
Ti-6Al-7Nb alloy
orthopedics
S.aureus
ortopedia
Opis:
The Gram-positive coccus, Staphylococcus aureus, is the leading etiologic agent of limb and life-threatening biofilm-related infections in the patients following the orthopaedic implantations. The aim of the present paper is to estimate the ability of S. aureus to form biofilm on titanium alloy (Ti-6Al-7Nb) scaffolds produced by Selective Laser Melting (SLM) and subjected to the different types of surface modifications, including ultrasonic cleaning and chemical polishing. The results obtained indicate significantly the decreased ability of S.aureus to form biofilm on the surface of scaffolds subjected to the chemical polishing in comparison to the scaffolds cleaned ultrasonically. The data provided can be useful for future applications of the SLM technology in production of Ti-6Al-7Nb medical implants.
Źródło:
Acta of Bioengineering and Biomechanics; 2013, 15, 1; 69-76
1509-409X
2450-6303
Pojawia się w:
Acta of Bioengineering and Biomechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie mikrotomografii komputerowej w analizie żywności
The use of micro computed tomography in food analysis
Autorzy:
Zalewska, M.
Powiązania:
https://bibliotekanauki.pl/articles/270843.pdf
Data publikacji:
2016
Wydawca:
Centralny Ośrodek Badawczo-Rozwojowy Aparatury Badawczej i Dydaktycznej, COBRABiD
Tematy:
mikrotomografia komputerowa
struktura żywności
wizualizacja 3D
micro-CT
micro-computed tomography
food structure
3D visualization
Opis:
Celem niniejszej pracy jest przedstawienie metody mikrotomografii komputerowej (micro-CT), jako przydatnego narzędzia do analizy żywności. Micro-CT to nieinwazyjna technika badawcza, która pozwala odwzorować strukturę wewnętrzną badanego obiektu na podstawie jego dwuwymiarowych projekcji zarejestrowanych pod różnymi kątami. Pozwala na odkrycie struktur wewnętrznych bez ingerencji w fizyczną strukturę badanego materiału. Metoda ta znalazła zastosowanie w wielu dziedzinach nauki i techniki. W przemyśle spożywczym może być wykorzystana do analizy produktów żywnościowych, do oszacowania zawartości poszczególnych składników żywności, a także uzyskania informacji na temat ich rozmieszczenia. Zastosowanie mikrotomografii komputerowej pozwala na zachowanie wysokiej jakości produktów podczas procesu produkcyjnego. Metoda ta przydatna jest także w celu optymalizacji procesów, czyli w uzyskaniu informacji na temat parametrów procesu technologicznego. W pracy przedstawiono zastosowanie metody mikrotomografii komputerowej w przemyśle mięsnym, cukierniczym oraz owocowo-warzywnym.
The aim of this study is to present the method of computer microtomography (micro-CT) as a useful tool for the analysis of food. Micro-CT is a nondestructive research technique for studying the internal structure of the sample based on its two-dimensional projection recorded at different angles. Allows for the discovery of internal structures without interfering with the physical structure of the material being tested. This method has been used in many fields of science and technology. Estimated content of each food ingredients as well as provide information about their location. The use of computer microtomography allows to maintain the high quality of the products during the manufacturing process. This method is also useful for process optimization, which is obtained information about the parameters of technology microtomography use in the meat, confectionery and fruit-vegetables industry is presented.
Źródło:
Aparatura Badawcza i Dydaktyczna; 2016, 21, 2; 85-92
2392-1765
Pojawia się w:
Aparatura Badawcza i Dydaktyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies