Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Zajusz-Zubek, E." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Coal Cleaning Versus the Reduction of Mercury and other Trace Elements’ Emissions from Coal Combustion Processes
Autorzy:
Zajusz-Zubek, E.
Konieczyński, J.
Powiązania:
https://bibliotekanauki.pl/articles/204840.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heavy metals
steam coals
coal wet cleaning
densimetric fractions
mercury emission reduction
metale ciężkie
spalanie węgla
proces czyszczenia węgla
redukcja emisji rtęci
Opis:
Samples of steam coal used in heat and power plants as well as densimetric fractions obtained on a laboratory scale by dense organic liquid separation have been examined. The contents of ash, mercury, chromium, cadmium, copper, nickel and lead have been determined in coal, in the light and medium fraction as well as in the refuse. The degree of removal of mineral matter and the examined heavy metals as well as the coal combustible parts yield have been determined. Examination of 5 coals revealed that it is possible to remove 41% of mercury and more than 35% of other heavy metals bound to mineral matter in coal.
Źródło:
Archives of Environmental Protection; 2014, 40, 1; 115-127
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza występowania pierwiastków śladowych w formie mobilnej frakcji respirabilnej pyłu (PM2,5) pobranego w otoczeniu elektrowni węglowej
Analysis of trace elements in the mobile form of respirable fraction PM2.5 collected in the surroundings of power plant
Autorzy:
Zajusz-Zubek, E.
Mainka, A.
Powiązania:
https://bibliotekanauki.pl/articles/297310.pdf
Data publikacji:
2015
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
analiza specjacyjna
PM2,5
metale ciężkie
elektrownia węglowa
zanieczyszczenia powietrza
speciation analysis
heavy metals
power plant
air pollutants
Opis:
W pracy przedstawiono wstępne wyniki badań występowania wybranych pierwiastków śladowych (As, Cd, Co, Cr, Pb, Sb i Se), należących do grupy HAPs (ang. Hazardous Air Pollutants), w formie biodostępnej frakcji respirabilnej (PM2,5). Odpowiednią frakcję pyłu pobrano w otoczeniu pracującej elektrowni węglowej opalanej węglem kamiennym. Analiza specjacyjna frakcji pyłu PM2,5 została przeprowadzona według zmodyfikowanego schematu Tessiera z wykorzystaniem ekstrakcji formy rozpuszczalnej w wodzie (Frakcja 1). Średnie stężenia pierwiastków badanych we frakcji rozpuszczalnej w wodzie utworzyły następujący szereg: Pb>Cr>As>Sb>Cd>Se>Co. Jest on zbliżony do szeregu otrzymanego w źródłach literaturowych.
Research regarding environment and dust exposition conducted so far has been based on theoretical factors. These factors primarily concern the total content of heavy metals in suspended dust. However, there is a shortage of data on the specific chemical forms of trace elements. These forms condition the heavy metal threat on the environment and human health. Based on the results of chemical speciation, we can define the mobility of elements (including heavy metals) in the environment, that is, their bio-chemical activity during assimilation by organisms. The paper presents preliminary results of the occurrence of selected trace elements (As, Cd, Co, Cr, Pb, Sb and Se) that belong to the HAPs group (Hazardous Air Pollutants) in the PM2.5 water soluble form. The appropriate fraction of particulate matter was collected by Dekati PM10 Impactor in the surroundings of a working power plant that is fired with hard coal. The speciation analysis of PM2.5 fraction was conducted using a modified Tessier scheme. This procedure employs the extraction of a water soluble fraction (Fraction 1). The concentrations of elements were determined using the ICPMS technique. Measurements delivered data on the average concentration of respirable fraction PM2.5, which equaled 22.93 μg/m3. While conducting the research in the surroundings of a working power plant, a relatively high ratio of PM2.5 to TSP (83%) and to PM10 (88%) was found. Among the determined trace elements, the highest average total concentration in PM2.5 was found for Pb (82.17 ng/m3), while the lowest (less than 1 ng/m3) was found for Co. The highest average concentration in water soluble fraction F1 in PM2.5 was also found for Pb (12,97 ng/m3), while the lowest concentration (below 1 ng/m3) was found for Sb, Cd, Se and Co. The average concentrations of trace elements determined in the bioavailable fraction were found in a following order: Pb>Cr>As>Sb>Cd>Se>Co. This sequence is similar to the order received in the existing literature. In future, received data will assist in determining the forms of hazardous trace elements in total suspended particles (TSP), suspended dust (PM10) and in respirable fraction (PM2.5) in the surroundings of selected working power plants.
Źródło:
Inżynieria i Ochrona Środowiska; 2015, 18, 2; 245-258
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies