Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Machaj, B." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
Influence of aerosol concentration and multivariate processing on the indication of radon progeny concentration in air
Autorzy:
Machaj, B.
Urbański, P.
Powiązania:
https://bibliotekanauki.pl/articles/147261.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon progeny
measurement
data processing
Opis:
Measurements of radon progeny concentration in air by a radon progeny monitor are sensitive to the concentration of particles suspended in air. Minimum detectable concentration and accuracy of the measurement are determined by random errors of the monitor. Multivariate data processing can be used to decrease these random errors. Influence of aerosol concentration on the measured results of radon progeny concentration in air, by an RGR-30 mining radiometer, operating on the principle of alpha radiation detection from radon progeny deposited on an air filter, were determined in a radon chamber experiment. The air suspended particle concentration and the radon concentration in the radon chamber were controlled and the corresponding radon progeny concentration was measured by the radon progeny monitor. Additionally, count rate from the monitor detector, originating from the alpha activity deposited on the air filter, was measured at intervals of one minute and was then used for the three-interval, and Principal Component Regression (PCR) data processing. It was found that for the aerosol concentration in air from 40 p/cm3 to approximately 9,000 p/cm3 indications of the radon progeny monitor depends considerably on the aerosol concentration. Radon daughter concentration normalized to the radon concentration against aerosol concentration varied from 0.3 to 0.9. In mines, where the aerosol concentration generally is high, this phenomenon has little effect on the indication of the radon progeny monitor. At low aerosols concentration, appropriate correction of radon progeny concentration has to be taken. Comparison of random errors when measured signal of the monitor (count rate against time) was processed employing the three-interval method and PCR data processing shows that PCR ensures a lower random error.
Źródło:
Nukleonika; 2004, 49, 3; 123-129
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fast measurement of radon concentration in water with Lucas cell
Autorzy:
Machaj, B.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/147981.pdf
Data publikacji:
2004
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon in water
measurement
concentration
Opis:
Abstract Fast method of measurement of radon concentration in water based on flushing (bubbling) water sample with air in closed loop with Lucas cell is presented. The main feature of the method is washing radon from large sample of water to small volume of air including the volume of Lucas cell, thanks to which high radon concentration in the air and considerable sensitivity of measurement is achieved. Estimated measuring sensitivity is S = 8.5 cpm/(Bq/dm3). Random error due to statistical fluctuations of count rate at radon concentration 1, 100, 10 000 Bq/dm3 is: 11, 1.1, 0.1% correspondingly at counting (measuring) time 10 min. Minimum detectable radon concentration in water for such counting time is 0.11 Bq/dm3.
Źródło:
Nukleonika; 2004, 49, 1; 29-31
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Measurement of radon (222Rn) and thoron (220Rn) concentration with a single scintillation cell
Autorzy:
Machaj, B.
Urbański, P.
Bartak, J.
Powiązania:
https://bibliotekanauki.pl/articles/146829.pdf
Data publikacji:
2007
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
radon
thoron
measurement
scintillation cell
Opis:
. A single scintillation cell (ö 54 × 74 mm) is used for the measurement of radon and thoron. The radon and thoron laden air is filtered and forced to flow at 1 dm3/min through the scintillation cell in the period of 1 10 min. The count number from alpha radiation is registered in the periods of 3 10 min and 20 30 min. Two values of detection and deposition efficiency of alpha radiation are used for radon (at air flow and air at rest in the cell) and for thoron. Measurements of radon laden air and thoron laden air showed good agreement between the reference concentration and the measured concentration, not worse than 1% for radon and not worse than 2% for thoron. Combination of radon + thoron concentration showed also a small interference ("cross talk") not worse than 1%.
Źródło:
Nukleonika; 2007, 52, 4; 167-171
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies