Tytuł:
Damage Detection of Steel-Concrete Composite Beam
Diagnostyka uszkodzeń stalowo-betonowych belek zespolonych
Autorzy:
Szumigała, M.
Pełka-Sawenko, A.
Wróblewski, T.
Abramowicz, M.
Powiązania:
https://bibliotekanauki.pl/articles/396456.pdf
Data publikacji:
2018
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
steel-concrete composite beams
damage
detection
localization
Python
Abaqus
Matlab
belki zespolone stalowo-betonowe
uszkodzenia
detekcja
lokalizacja uszkodzeń
Opis:
The paper presents analysis results of steel-concrete composite beams, identification and attempts to detect damage introduced in a discrete model. Analysis of damage detection was conducted using DDL (Damage, Detection, Localization), our own original algorithm. Changes of dynamic and static parameters of the model were analysed in damage detection. Discrete wavelet transform was used for damage localization in the model. Prior to ultimate analysis, two-tier identification of discrete model parameters based on experimental data was made. In identification procedure, computational software (Python, Abaqus, Matlab) was connected in automated optimization loops. Results positively verified the original DDL algorithm for damage detection in steel-concrete composite beams, which enables further analysis using experimental data.
Niniejszy artykuł przedstawia wyniki analiz stalowo-betonowych belek zespolonych, identyfikację oraz próby detekcji uszkodzeń wprowadzonych w modelu dyskretnym. Analizy detekcji uszkodzeń przeprowadzono na podstawie opracowanego algorytmu UDL (Uszkodzenia D-detekcja, L-Lokalizacja). Podczas diagnostyki uszkodzeń analizowano zmiany w parametrach dynamicznych i statycznych modelu. Podczas lokalizacji uszkodzeń modelu wykorzystano dyskretną transformatę falkową. Analizy docelowe zostały poprzedzone dwupoziomowym procesem identyfikacji wybranych parametrów modelu dyskretnego w oparciu o wyniki badań doświadczalnych. Procedury identyfikacji przeprowadzono łącząc programy obliczeniowe (Python, Abaqus, Matlab) w automatyczne pętle optymalizacyjne. Wyniki przeprowadzonych analiz pozytywnie weryfikują opracowany algorytm UD-L do diagnostyki uszkodzeń stalowo-betonowych belek zespolonych, co pozwala na dalsze analizy w oparciu o badania doświadczalne.
Źródło:
Civil and Environmental Engineering Reports; 2018, No. 28(3); 30-49
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Supervisory fault tolerant control with integrated fault detection and isolation: a switched system approach
Autorzy:
Yang, H.
Jiang, B.
Cocquempot, V.
Lu, L.
Powiązania:
https://bibliotekanauki.pl/articles/331374.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
sterowanie tolerujące uszkodzenia
detekcja uszkodzeń
lokalizacja uszkodzeń
sterowanie rozdzielcze
układ komutowany
fault-tolerant control
fault detection
fault isolation
switching control
switched systems
Opis:
This paper focuses on supervisory fault tolerant control design for a class of systems with faults ranging over a finite cover. The proposed framework is based on a switched system approach, and relies on a supervisory switching within a family of pre-computed candidate controllers without individual fault detection and isolation schemes. Each fault set can be accommodated either by one candidate controller or by a set of controllers under an appropriate switching law. Two aircraft examples are included to illustrate the efficiency of the proposed method.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2012, 22, 1; 87-97
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robust MPC for actuator-fault tolerance using set-based passive fault detection and active fault isolation
Autorzy:
Xu, F.
Puig, V.
Ocampo-Martinez, C.
Olaru, S.
Niculescu, S. I.
Powiązania:
https://bibliotekanauki.pl/articles/330788.pdf
Data publikacji:
2017
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
fault detection
fault isolation
set theoretic method
fault tolerant control
model predictive control
detekcja uszkodzeń
lokalizacja uszkodzeń
sterowanie tolerujące uszkodzenia
sterowanie predykcyjne
Opis:
In this paper, a fault-tolerant control (FTC) scheme is proposed for actuator faults, which is built upon tube-based model predictive control (MPC) as well as set-based fault detection and isolation (FDI). In the class of MPC techniques, tube-based MPC can effectively deal with system constraints and uncertainties with relatively low computational complexity compared with other robust MPC techniques such as min-max MPC. Set-based FDI, generally considering the worst case of uncertainties, can robustly detect and isolate actuator faults. In the proposed FTC scheme, fault detection (FD) is passive by using invariant sets, while fault isolation (FI) is active by means of MPC and tubes. The active FI method proposed in this paper is implemented by making use of the constraint-handling ability of MPC to manipulate the bounds of inputs. After the system has been detected to become faulty, the input-constraint set of the MPC controller is adjusted to actively excite the system for achieving FI guarantees on-line, where an active FI-oriented input set is designed off-line. In this way, the system can be excited in order to obtain more extra system-operating information for FI than passive FI approaches. Overall, the objective of this paper is to propose an actuator MPC scheme with as little as possible of FI conservatism and computational complexity by combining tube-based MPC and set theory within the framework of MPC, respectively. Finally, a case study is used to show the effectiveness of the proposed FTC scheme.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2017, 27, 1; 43-61
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active fault tolerant control of nonlinear systems: the cart-pole example
Autorzy:
Bonfe, M.
Castaldi, P.
Mimmo, N.
Simani, S.
Powiązania:
https://bibliotekanauki.pl/articles/907604.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
detekcja uszkodzeń
lokalizacja uszkodzeń
filtracja nieliniowa
sterowanie tolerujące uszkodzenia
fault detection
fault isolation
nonlinear filter
nonlinear geometric approach
fault tolerant control
cart pole nonlinear model
Opis:
This paper describes the design of fault diagnosis and active fault tolerant control schemes that can be developed for nonlinear systems. The methodology is based on a fault detection and diagnosis procedure relying on adaptive filters designed via the nonlinear geometric approach, which allows obtaining the disturbance de-coupling property. The controller reconfiguration exploits directly the on-line estimate of the fault signal. The classical model of an inverted pendulum on a cart is considered as an application example, in order to highlight the complete design procedure, including the mathematical aspects of the nonlinear disturbance de-coupling method based on the nonlinear differential geometry, as well as the feasibility and efficiency of the proposed approach. Extensive simulations of the benchmark process and Monte Carlo analysis are practical tools for assessing experimentally the robustness and stability properties of the developed fault tolerant control scheme, in the presence of modelling and measurement errors. The fault tolerant control method is also compared with a different approach relying on sliding mode control, in order to evaluate benefits and drawbacks of both techniques. This comparison highlights that the proposed design methodology can constitute a reliable and robust approach for application to real nonlinear processes.
Źródło:
International Journal of Applied Mathematics and Computer Science; 2011, 21, 3; 441-455
1641-876X
2083-8492
Pojawia się w:
International Journal of Applied Mathematics and Computer Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fault tolerant control of wind turbine via identified fuzzy models prototypes
Autorzy:
Djoudi, Habib Chaouki Ben
Hafaifa, Ahmed
Djoudi, Dalila
Guemana, Mouloud
Powiązania:
https://bibliotekanauki.pl/articles/328473.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
fault detection
fault isolation
fault tolerant control
Benchmark model
proportional integral control
fuzzy control
turbina wiatrowa
detekcja uszkodzeń
lokalizacja uszkodzeń
sterowanie odporne na uszkodzenia
sterowanie rozmyte
Opis:
The main purpose of this study is the comparison of two control strategies of wind turbine 4.8 MW, using fuzzy control and proportional integral control, taking into account eight kinds of faults that can occur in a wind turbine model. A technique based on fault diagnosis has been used to detect and isolate faults actuators and sensors in this system, it's about an observer applied to the benchmark model. The obtained results are presented to validate the effectiveness of this diagnostic method and present the results of the proposed control strategies.
Źródło:
Diagnostyka; 2020, 21, 3; 3-13
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies