Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "AOP" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Influence of pH in AOP on Humic Compounds Removal from Municipal Landfill Leachate Concentrate after Reverse Osmosis
Autorzy:
Koc-Jurczyk, Justyna
Jurczyk, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/125093.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
AOP
Fenton's reagent
RO retentate
landfill leachate
Opis:
The choice of the optimal method of municipal waste landfill leachate treatment should take into account such factors as: the variability of their composition and quantity over time, requirements for effluent or economic capacity. Due to the variety of compounds found in landfill leachate, it is advised to use a combination of different treatment processes. Biological methods are effective in the treatment of leachates from young landfills, but generally their efficiency declines significantly with the age of the landfill. Therefore, the physicochemical methods, i.e. advanced oxidation, adsorption, membrane methods or a combination of the mentioned, are preferred. The aim of the study was the assessment of the Fenton’s reagent utilization to process reverse osmosis concentrate of leachates collected from municipal non-hazardous waste landfill. The research was focused on the influence of pH on the process. Additionally, the effectiveness of organic compounds removal, increasing the biodegradability, as well as humic substances transformations were determined. The concentrations of humic compounds were measured by means of optical density at the wavelengths: 254, 265, 280, 320, 465 and 665 nm. In the experiment, the H2O2/Fe2+ 10: 1 ratio was tested at with a dose of H2O2 equal to 3.4 g/l (0.1 M). It was found that the pH affects the efficiency of COD removal and the increase of the biodegradability of the landfill leachate retentate, as well as the removal of humic substances and its transformation. It was found that at pH 3, the highest removal of COD occurs, with simultaneous increase in biodegradability, and decrease of absorbance caused by humic compounds.
Źródło:
Journal of Ecological Engineering; 2019, 20, 2; 161-168
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ relacji Fe:H2O2 na skład odcieków składowiskowych po oczyszczaniu metodą Fentona
The impact of relation Fe:H2O2 on the composition of leachate after treatment Fenton’s method
Autorzy:
Muszyńska, J.
Gawdzik, J.
Sikorski, M.
Powiązania:
https://bibliotekanauki.pl/articles/126886.pdf
Data publikacji:
2018
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
odcieki składowiskowe
AOP
proces Fentona
remediacja odcieków
landfill leachate
Fenton process
remediation of leachate
Opis:
W wyniku funkcjonowania składowisk odpadów powstają odcieki, które są odzwierciedleniem zmian zachodzących w czaszy składowiska. Na początku funkcjonowania składowiska powstają odcieki zawierające głównie produkty podatne na biodegradację, wraz z upływem czasu rośnie ilość związków trudno biodegradowalnych. Ze względu na zmienność składu i ilości powstających odcieków ich oczyszczanie jest trudnym zadaniem technologicznym i wymaga szeregu badań. Do oczyszczania odcieków stosowane są zarówno metody biologiczne, fizyczno-chemiczne, jak i metody pogłębionego utleniania, np. metoda Fentona. W artykule przedstawiono problematykę dotyczącą wpływu relacji Fe:H2O2 w procesie Fentona na skład oczyszczonych odcieków i redukcję wybranych zanieczyszczeń. Omówiono parametry fizyczno-chemiczne odcieków surowych oraz po procesie oczyszczania metodą Fentona. Celem badań, oprócz wykonania analiz chemicznych, było również określenie zależności pomiędzy stosunkiem Fe:H2O2 a efektem obniżenia wartości wybranych wskaźników zanieczyszczeń. Wyniki analiz odniesiono do dopuszczalnych zakresów stężeń wybranych substancji zamieszczonych w rozporządzeniach krajowych. Proces Fentona prowadzono przy stosunku wagowym Fe:H2O2 jak 1:3, 1:5, 1:7, 1:10 przy dawce Fe co 50 g/m3 w zakresie od 50-400 g/m3. W odciekach surowych i oczyszczonych analizowano zawartość takich parametrów, jak ChZT, OWO, UV254, barwa. Na podstawie wyników badań wybrano optymalną relację Fe:H2O2. Wyjaśniono możliwe przyczyny niskiej skuteczności wysokich dawek Fe przy relacji Fe/H2O2 1:10.
As a result of the storage of waste, generation of leachate reflect changes in the canopy landfill. At the beginning of landfill operation, the landfill leachate arise mainly products biodegradable, over time, increasing the number of non-biodegradable compounds. Due to the variability of the composition and quantity of leachate generated their cleaning is difficult and requires a number of technological research. For leachate treatment they are used both methods of biological and physico-chemical methods such as advanced oxidation e.g. Fenton’s method. The article presents the problem of the impact of the relationship between Fe/H2O2 ratio of process Fenton on the composition of treated effluent and a reduction of selected pollutants. The physico-chemical parameters of raw leachate and after the process of purification by Fenton have been discussed. The aim of the research, in addition to performing chemical analyses, was also to determine the relationship between the ratio Fe:H2O2 and the reduction of selected pollutants. The results of analyses related to the limit values given in national regulations. Fenton process was carried out at a weight of Fe: H2O2 ratio: 1: 3, 1: 5, 1: 7, 1:10 Fe at a dose of 50 g/m3 in the range of 50-400 g/m3. The leachate raw and analysed the contents of parameters such as COD, TOC, UV254, colour. Based on the results of research we selected the optimal ratio of Fe:H2O2. The possible causes of low effectiveness of high doses of Fe for the ratio Fe:H2O2 1:10 was explained.
Źródło:
Proceedings of ECOpole; 2018, 12, 1; 211-217
1898-617X
2084-4557
Pojawia się w:
Proceedings of ECOpole
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of Advanced Oxidation Processes (AOP) for the treatment of landfill leachate
Wykorzystanie zaawansowanych metod utleniania (AOP) do oczyszczania odcieków składowiskowych
Autorzy:
Jelonek, P.
Neczaj, E.
Powiązania:
https://bibliotekanauki.pl/articles/297705.pdf
Data publikacji:
2012
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
odcieki składowiskowe
zaawansowane metody utleniania
AOP
zwiększenie biodegradowalności
landfill leachate
advanced oxidation processes
biodegradability enhancement
Opis:
Formation of leachate poses a problem closely related to the use of landfill sites. Landfill leachate is a wastewater, which as a result of permeation elutes mineral and organic compounds from a bed. Due to its diverse composition, both physical and chemical, it is necessary to purify the leachate before its discharge into drains or a natural receiver. The following article shows that there is a variety of pollutants in municipal landfill leachate. It also presents the dependency existing between the age of a landfill site, and the concentration of pollutants in leachate, as well as how it affects biodegradation of contaminants. There were discussed various methods to purify leachate and the physical, chemical, physico- -chemical and biochemical processes were compared. Comparing these processes, many factors were taken into account: the efficiency and effectiveness of the processes, their side effects, the costs, the amount of energy that is required for a process to take place, reaction dynamics, and more. A successful purification of leachate with use of a single process unit is not possible. Therefore, there are used hybrid systems that combine biological methods of physico-chemical processes, especially the advanced oxidation processes. The most important among the chemical processes used for treatment of leachate are Advanced Oxidation Processes - AOP. Advanced oxidation processes are divided into chemical and photochemical oxidation. The most commonly used methods include oxidation with ozone and hydrogen peroxide and Fenton's reagent oxidation. Processes using ozone are usually employed as the third stage of landfill leachate treatment. This process allows discharge of the leachate into a receiver. The largest decreases in the number of pollutants are obtained using combined processes. Some of the best effects were observed after employment of oxidation both with ozone and hydrogen peroxide, helping to additionally enhance this process photocatalytically. AOP proved to be the most effective method of treatment of waste water that contains organic products (waste water from chemical and agrochemical industries, textiles, paints, dyes). More conventional techniques cannot be used to treat such compounds because of their high chemical stability and low biodegradability. There was also performed a literature review in the field of biological, physical and chemical purification methods of landfill leachate.
Problemem ściśle związanym z użytkowaniem składowiska odpadów komunalnych jest powstawanie odcieków oraz konieczność ich oczyszczania. Odcieki składowiskowe są wodami odpadowymi, które w wyniku przenikania przez złoże wymywają z niego związki mineralne i organiczne. Ze względu na różnorodny skład zarówno fizyczny, jak i chemiczny istnieje konieczność ich oczyszczenia przed odprowadzeniem do odbiornika naturalnego bądź kanalizacji. Liczba i różnorodność związków chemicznych, jakie występują w odciekach, jest ogromna, a ich pełna identyfikacja praktycznie niemożliwa. W artykule omówiono zależność, jaka występuje między wiekiem składowiska a stężeniem zanieczyszczeń w odciekach, a także, jak powyższa zależność wpływa na biodegradację zanieczyszczeń. Do oczyszczania odcieków z młodych składowisk można stosować metody biologiczne z uwagi na znaczne stężenie zanieczyszczeń podatnych na biodegradację. Do usuwania zanieczyszczeń trudno rozkładalnych, znajdujących się w odciekach ze składowisk ustabilizowanych, zastosowanie znajdują różnorodne metody fizyczne i chemiczne. Przy doborze odpowiedniej metody oczyszczania odcieków ze składowisk odpadów komunalnych należy przeprowadzić wnikliwą analizę ich właściwości fizycznych i chemicznych. Należy ponadto rozpatrzyć technologie składowania odpadów, rodzaje składowanych odpadów, jakość i ilość odcieków, jakie powstają, oraz wielkość składowiska. Trzeba również uwzględnić przewidywany czas eksploatacji składowiska, jak również wymogi prawne, pozwalające na odprowadzenie uprzednio oczyszczonych odcieków do odbiornika. Prowadzone od wielu lat badania ukazują, iż niemożliwe jest dobre oczyszczenie odcieków, kiedy stosuje się jeden proces jednostkowy. Zwykle wykorzystuje się do tego celu układy hybrydowe, które łączą metody biologiczne z procesami fizyczno-chemicznymi: procesy zaawansowanego utleniania, metody membranowe bądź procesy sorpcji na węglu aktywnym. Coraz większą uwagę skupia się na wykorzystaniu zaawansowanych procesów utleniania - AOP (Advanced Oxidation Processes) do oczyszczania ścieków o niewielkiej podatności na biodegradację. Cechą, która wyróżnia te procesy, jest czynnik utleniający. Czynnikami utleniającymi są bardzo reaktywne rodniki hydroksylowe. Posiadają one wysoki potencjał utleniająco- redukcyjny, dzięki czemu są zdolne do utleniania związków organicznych. Procesy AOP prowadzą do mineralizacji zanieczyszczeń, polegającej na utlenieniu zanieczyszczenia do dwutlenku węgla, wody i nieorganicznych związków. Zastosowanie AOP jako obróbki wstępnej, wspomagającej oczyszczanie biologiczne, powoduje, że procesy te są efektywne i opłacalne z punktu widzenia ekonomicznego. Do najczęściej stosowanych metod chemicznych zaliczamy utlenianie ozonem, nadtlenkiem wodoru oraz utlenianie odczynnikiem Fentona. Ozonowanie stosuje się najczęściej jako trzeci stopień oczyszczania odcieków wysypiskowych. Metody zaawansowanego utleniania wydają się obiecującą alternatywą dla konwencjonalnych sposobów postępowania z odciekami ze składowisk odpadów komunalnych. Niemniej jednak wysoki koszt technologii AOP oraz nie do końca poznany mechanizm reakcji chemicznych i fizycznych wymaga wciąż prowadzenia dodatkowych badań naukowych.
Źródło:
Inżynieria i Ochrona Środowiska; 2012, 15, 2; 203-217
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies