Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "modular construction" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
The optimal insulation thickness determined for modular buildings according to multi-criteria analysis
Autorzy:
Zhelykh, Vasyl
Furdas, Yurii
Powiązania:
https://bibliotekanauki.pl/articles/2065646.pdf
Data publikacji:
2021
Wydawca:
Politechnika Częstochowska
Tematy:
izolacja termiczna
pianka poliuretanowa
konstrukcja modułowa
thermal insulation
polyurethane foam
modular construction
petal diagrams
Opis:
The possibility of using modular buildings for residential and public needs is considered. Due to the peculiarities of technology and the use of thermal insulation materials, such structures are erected in a short time with the help of ready-made modules, characterized by their simplicity and speed of installation. The results of the multi-criteria analysis are presented in the form of petal diagrams and diagrams of global priorities.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2021, 10, 1; 43--51
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikroskop STM/AFM do zastosowań badawczych w zaawansowanych technologiach w przemyśle oraz w dydaktyce szkół wyższych
STM/AFM microscope for application in industrial advanced technologies and the high schools education
Autorzy:
Majcher, A.
Mrozek, M.
Zbrowski, A.
Olejniczak, W.
Pawłowski, S.
Piskorski, M.
Powiązania:
https://bibliotekanauki.pl/articles/256874.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
mikroskop STM/AFM
magistrala VME
konstrukcja modułowa
microscope STM/AFM
VME bus
modular construction
Opis:
W artykule przedstawiono zagadnienia konstrukcyjne związane z budową i oprogramowaniem tunelowego mikroskopu skaningowego oraz mikroskopu sił atomowych. Opracowane urządzenie łączy obydwie funkcje, a dostosowanie do spełniania jednej z nich odbywa się przez wymianę jednej z części głowicy pomiarowej oraz uruchomienia odpowiedniego fragmentu oprogramowania. Z uwagi na przeznaczenie mikroskopu do badań przemysłowych oraz do nauczania podstaw nanotechnologii w szkołach wyższych zostały zastosowane rozwiązania ułatwiające obsługę, a zwłaszcza proces wstępnej regulacji aparatury. Dzięki zastosowaniu modularnej konstrukcji aparatury oraz oprogramowania możliwe jest przystosowanie urządzenia do dalszej rozbudowy rozszerzającej zakres aplikacji.
Construction matters connected with software of scanning tunneling microscope and atomic force microscope have been presented in the article. Those presented devices connect both functions and adaptation of one of the functions which is held by an exchange of one of the parts of the measure heads and by setting an appropriate part of the software in motion. Taking into consideration the fact that the microscope is going to be used in industrial tests as well as to teach basis of nanotechnology at universities, some solutions that made the operation easier have been used - especially the process of initial regulation of the device. Thanks to the implementation of modular construction of the device and the software it is possible to accommodate the device to extend the range of applications.
Źródło:
Problemy Eksploatacji; 2011, 3; 177-188
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the bearing resistance of the modified bolted end-plate joints of thin-walled profiles used in modular construction
Analiza nośności zmodyfikowanych śrubowych złączy doczołowych profili cienkościennych stosowanych w budownictwie modułowym
Autorzy:
Prałat, Karol
Plis, Arkadiusz
Powiązania:
https://bibliotekanauki.pl/articles/27312093.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
konstrukcja modułowa
nośność konstrukcji
kształtownik cienkościenny
węzeł konstrukcyjny
złącze śrubowe
złącze doczołowe
bearing resistance
modular construction
construction node
thin-walled profile
bolted joint
end-plate joint
Opis:
The paper presents the results of testing the bearing resistance of the bolted joints of thin-walled profiles used in modular construction. The two types of joints currently applied in the construction industry were subjected to tests. One of them served as the reference sample, and the other as the research sample, which was used to find a solution that is more favorable in terms of the complexity of its production process and its bearing resistance. In addition to the modified shape of the end-plates, the bearing resistance of the joint was also analyzed with regards to the different diameters of bolts (bolts M12 and M16 were used), their classes (the difference between bolts of class 8.8 and 10.9 was examined), and also the number of them in the joint (3 or 5 bolts). Moreover, two thicknesses of steel sheets (3 mm and 4 mm), from which thin-walled cold-bent profiles were made, were used in the research. The bearing resistance tests were carried out with the use of a testing press of the authors’ own design. On the basis of the measurements, plots of the dependence between the deflection of the samples and the force acting in the middle of their span were drawn. It was shown that the tested profile joint had an increased bearing resistance by up to 26% when compared to the reference sample. The maximum destructive bending moment M was equal to 10,7 kN·m for the reference sample, and to 13.5 kN·m for the analyzed design solution. In total, 6 types of modified joints were made for the tests, of which five showed a comparable or higher bearing resistance than the reference sample. Each type of joint was tested by bending it in two directions in relation to the central axis of its cross-section.
W pracy przedstawiono wyniki badań nośności połączeń, skręcanych profili cienkościennych wykorzystywanych w budownictwie modułowym. W badaniach wykorzystano dwa typy połączeń obecnie stosowanych w budownictwie, z których jedno posłużyło jako próba odniesienia, natomiast drugie jako próba badawcza mająca na celu znalezienie rozwiązania korzystniejszego pod względem złożoności procesu produkcyjnego oraz nośności połączenia. Oprócz zmodyfikowanego kształtu blach czołowych, dokonano również analizy nośności połączenia w zależności od wykorzystanych różnych średnic śrub (stosowano śruby M12 oraz M16), jak również ich klasy (zbadano różnicę pomiędzy śrubami klasy 8.8 i 10.9) i ilości w połączeniu (3 lub 5 śrub). Ponadto w badaniach wykorzystano dwie grubości blach stalowych, z których wykonano łączone zimnogięte profile cienkościenne (3 mm i 4 mm). Próby nośności przeprowadzono z wykorzystaniem prasy wytrzymałościowej własnej konstrukcji. Na podstawie pomiarów sporządzono wykresy zależności ugięcia próbek od działającej w środku ich rozpiętości siły. Wykazano, że badane połączenie profili spowodowało wzrost ich nośności nawet o 26% w stosunku do próby odniesienia. Maksymalny niszczący moment zginający M wynosił 10,7 kN·m w przypadku próbki odniesienia oraz 13,5 kN·m w przypadku analizowanego rozwiązania konstrukcyjnego. Łącznie do testów wykonano 6 typów połączeń modyfikowanych, z czego 5 z nich wykazało nośność porównywalną, lub wyższą od próby odniesienia. Każdy z typów połączenia badano poprzez zginanie w dwóch kierunkach, względem osi centralnych przekroju.
Źródło:
Archives of Civil Engineering; 2023, 69, 2; 245--263
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies