Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "kocioł, A." wg kryterium: Wszystkie pola


Wyświetlanie 1-10 z 10
Tytuł:
Influence of the environment on the operational safety of a fluidized bed boiler
Autorzy:
Dudek, Agata
Kobyłecki, Rafał
Powiązania:
https://bibliotekanauki.pl/articles/88702.pdf
Data publikacji:
2019
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
fluidized bed boiler
anchors
refractory damage
kocioł fluidalny
kotwy
uszkodzenie ogniotrwałe
Opis:
The use of fluidized bed boilers in modern power engineering is a promising solution for clean and economically acceptable combustion of various fuels, including coal, biomass and waste, for the generation of electricity. The fluidized bed boilers are nowadays technically advanced and complex combustion facilities where all individual boiler elements are subjected to withstand continuous structural and thermal loads during their operation. Intensive loading of boiler elements can be quite easily linked with boiler operational safety and is quite often one of the main reasons for emergency shutdowns followed by necessary replacements of the damaged items. In case of industrial large-scale circulating fluidized bed boilers the frequency of unplanned shutdowns is also quite often affected by the hydrodynamics of the fluidized bed and some other parameters, such as the intensity of solids circulation, temperature, solids concentration, flue gas composition and velocity, solids accumulation and deposition, as well as the corrosion or erosion of heat transfer surfaces. The present paper briefly reports the results of authors investigation focused on the morphology and structure of some chosen elements (steel anchors) sampled from one of Polish circulating fluidized bed boilers. The anchors were degraded during boiler operation and lost their mechanical durability. In order to determine the reasons of anchors’ degradation chemical composition of the elements was determined with the use of a spark spectrometer SPECTROLAB and sample morphology was investigated with JEOL JSM-6610LV scanning microscope equipped with LaB6 cathode.
Źródło:
System Safety : Human - Technical Facility - Environment; 2019, 1, 1; 678-683
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie komputerowe przegrzewacza pary w kotle fluidalnym
CFD modeling of a CFB boiler superheater
Autorzy:
Ludowski, P.
Powiązania:
https://bibliotekanauki.pl/articles/172952.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł fluidalny
przegrzewacz pary
symulacja numeryczna
proces przepływowo-cieplny
fluidized bed boilers
superheater
computer simulation
flow-thermal process
Opis:
W pracy przedstawiono symulację komputerową przegrzewacza grodziowego drugiego stopnia usytuowanego w górnej części kotła fluidalnego OFz-425. Przegrzewacz zbudowany jest z rur omega o złożonym kształcie przekroju poprzecznego. Za pomocą trójwymiarowej symulacji numerycznej wyznaczony został rozkład temperatury w ściance rury oraz w przepływającej parze przy założeniu, że temperatura złoża fluidalnego w komorze paleniskowej jest znana. Wyniki obliczeń mogą być wykorzystane do prawidłowego doboru długości rur przegrzewacza oraz doboru gatunku stali na poszczególne biegi przegrzewacza. Pokazano również przykład rozwiązania odwrotnego zagadnienia wymiany ciepła występującego w regulacji temperatury pary przegrzanej przegrzewacza. Problem odwrotny polega na wyznaczeniu temperatury na wlocie rury przegrzewacza przy zadanej temperaturze na wylocie.
A computational fluid dynamics (CFD) simulation was carried out for the platen superheater placed in the combustion chamber of the OFe-425 CFB boiler. Superheater consists of omegatype tubes with complex shape of cross-section. Using the 3D numerical simulation determined was temperature distribution in the tube wall and flowing past steam at the assumption that temperature of fluidised bed in chamber is known. results of calculations can be used for appropriate selection of the superheater tube length as well as selection of the steel type for specific tube passes. Presented also is an example of inverse solution of heat transfer problem which is present in temperature control of superheated steam. The inverse problem is related to temperature distribution an inlet to the superheater at a given outlet temperature. Velocity, pressure, and temperature of the steam as well as the temperature of the tube wall with the complex cross section were computed using the ANSYS_CFX software. The direct and inverse problems were solved. In the inverse problem, the steam temperature at tube inlet waas determined based on the temperature at the outlet of the tube. The inverse problem was solved iteratively.
Źródło:
Archiwum Energetyki; 2011, 41, 2; 75-88
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of Air and Oxy-fuel Combustion in a Circulating Fluidized Bed
Modelowanie procesu spalania powietrznego oraz tlenowego w cyrkulacyjnej warstwie fluidalnej
Autorzy:
Adamczyk, W.
Powiązania:
https://bibliotekanauki.pl/articles/397035.pdf
Data publikacji:
2016
Wydawca:
ENERGA
Tematy:
fluidization
modeling
dense flow
combustion
kocioł fluidalny
modelowanie
gęste przepływy
spalanie
Opis:
The paper presents the use of a computer model to simulate the process of fluidization in an industrial boiler at Turów power plant. Air and oxy-fuel combustion was modelled for the study, and the effect of the geometrical model’s simplification on the bulk material distribution in the combustion chamber was examined. Numerical simulations were performed using Ansys FLUENT software enhanced with additional user defined functions that were implemented in the calculation procedure. The computer model allowed for the analysis of the effect of solid phase’s volume fraction in the combustion chamber on the heat exchange between the bulk material and the boiler’s heated surfaces. The computer simulation results showed satisfactory consistence with measured data.
W pracy przedstawiono wykorzystanie modelu komputerowego do symulacji procesu fluidyzacji w przemysłowym kotle elektrowni Turów. W pracy modelowany był proces spalania powietrznego oraz tlenowego, a także badany był wpływ uproszczeń modelu geometrycznego na dystrybucję materiału sypkiego w komorze spalania. Symulacje numeryczne zostały przeprowadzone z wykorzystaniem oprogramowania Ansys FLUENT rozszerzonego o dodatkowe funkcje użytkownika, które zostały zaimplementowane do procedury obliczeniowej. Opracowany model komputerowy pozwolił na analizę wpływu udziału objętościowego fazy stałej w komorze spalania na proces wymiany ciepła pomiędzy materiałem sypkim a powierzchniami ogrzewalnymi kotła. Wyniki symulacji komputerowych pokazały zadowalającą zgodność z danymi pomiarowymi.
Źródło:
Acta Energetica; 2016, 2; 6-13
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja nieszczelności kotła fluidalnego z użyciem modeli rozmyto-neuronowych
Approach to boiler leak detection with fuzzy neural models
Autorzy:
Szadkowski, B.
Jankowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/257517.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Technologii Eksploatacji - Państwowy Instytut Badawczy
Tematy:
detekcja awarii
systemy rozmyto-neuronowe
kocioł fluidalny
modelowanie
detection of outage
fuzzy-neural system
fluidised bed boiler
modelling
Opis:
Zreferowano badania modelowe nad detekcją nieszczelności kotłów fluidalnych z wykorzystaniem danych z archiwum. Modelowanie prowadzono w przyborniku Fuzzy Logic pakietu Matlab. Omówiono dwa podejścia do rozwiązania problemu. W pierwszym - opracowano modele rozmyto-neuronowe typu Takagi-Sugeno-Kanga (TSK) 4 zmiennych procesowych o dużej wrażliwości na przeciek. Uśrednione residua tych zmiennych, w przesuwnym oknie czasowym, pozwoliły wykryć 7 z 8 rozważanych przypadków nieszczelności. Oceniono długość okna i uzyskane wyprzedzenie detekcji względem wyłączenia bloku. Następnie opracowano i przetestowano model awarii o binarnym wyjściu. Równoległe wykorzystanie opracowanych modeli pozwoliło na wykrycie z kilkudniowym wyprzedzeniem wszystkich analizowanych awarii, potwierdzając przydatność modeli TSK w ważnym zadaniu eksploatacyjnym. Wskazano dalsze kierunki prac.
The research results into leak detection in a fluidised bed boiler are presented. The studies took advantage of the historical data from DCS in the professional power plant. Models of neuro-fuzzy Takagi-Sugeno-Kanga (TSK) type were built and tested in the Fuzzy Toolbox of Matlab. The roots of boiler outage (in water-steam pressure system and aside from this system) are indicated. The two approaches to leak detection task are described. In the first, the models of the 4 process variables sensitive to leakage were built. The residues of these models were evaluated in a moving time window. The length of the time window and the advance of leakage detection are discussed. Next, the model the TSK of the boiler faults with binary output was built and tested. Training data was collected for 3 cases of raised outage (models output - 1) and the normal work of installation (models output - 0). The parallel usage of proposed TSK models provided a successful detection of all studied fault cases a few days in advance. This has confirmed the suitability of the fuzzy neural models in an important exploitation task.
Źródło:
Problemy Eksploatacji; 2011, 2; 181-188
1232-9312
Pojawia się w:
Problemy Eksploatacji
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Charakterystyka popiołów ze spalania biomasy w kotłach fluidalnych
Characteristics of ash from the combustion of biomass in fluidized bed boilers
Autorzy:
Uliasz-Bocheńczyk, A.
Pawluk, A.
Pyzalski, M.
Powiązania:
https://bibliotekanauki.pl/articles/215950.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
popiół lotny
spalanie biomasy
kocioł fluidalny
skład chemiczny
wymywalność
skład fazowy
fly ash
biomass combustion
fluidized bed boiler
chemical composition
leachability
phase composition
Opis:
Energetyka zawodowa w zakresie wytwarzania energii ze źródeł odnawialnych wykorzystuje przede wszystkim biomasę, która jest stosowana jako paliwo podstawowe lub w procesie współspalania z węglem. Tak jak w przypadku węgla również przy wykorzystaniu biomasy w energetyce zawodowej powstają uboczne produkty spalania, przede wszystkim w postaci popiołów lotnych. Produkty te różnią się znacząco od tych pozyskanych ze spalania węgla. O ich właściwościach decyduje przede wszystkim rodzaj spalanej biomasy i typ kotła. Ze względu na coraz większy nacisk związany z wykorzystaniem energii ze źródeł odnawialnych, wynikający z wymogów Polityki Energetycznej Polski oraz z przepisów UE, powstaje coraz więcej tego typu odpadów. Popioły ze współspalania biomasy są materiałem stosunkowo dobrze scharakteryzowanym, szczególnie z kotłów konwencjonalnych. Uboczne produkty spalania biomasy są odpadami, które ze względu na właściwości mają ograniczone możliwości wykorzystania gospodarczego. Szczególnie problematyczne są popioły ze spalania w kotłach fluidalnych. W artykule przedstawiono wyniki badań podstawowych właściwości trzech popiołów ze spalania biomasy w kotłach fluidalnych oraz jednego – porównawczo – ze współspalania biomasy z węglem kamiennym w kotle pyłowym przy zastosowaniu tego samego rodzaju biopaliwa. [...]
When it comes to the production of energy from renewable sources, biomass is the main fuel, burned directly or co-fired with coal, used in the professional power industry. As in the case of coal, the use of biomass in the professional power industry is accompanied by the generation of by-products of the combustion process, primarily in the form of fly ash. These wastes significantly differ from those resulting from coal combustion. Their properties depend primarily on the burned biomass and boiler type. Due to the growing pressure on the use of energy from renewable sources resulting from the Energy Policy of Poland and the requirements imposed by the EU, more and more by-products are produced. Ashes from the co-firing of biomass are relatively well studied, especially when it comes to those resulting from the combustion in conventional boilers. The by-products of biomass combustion are of limited economic use due to their specific characteristics. The ashes resulting from the combustion in fluidized bed boilers are particularly problematic. The paper presents the research results on the basic properties of the three ashes generated from the combustion of biomass in fluidized bed boilers and one ash resulting from the co-firing of biomass with coal in pulverized coal boiler for the same biofuel type. [...]
Źródło:
Gospodarka Surowcami Mineralnymi; 2016, 32, 3; 149-162
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A thermodynamic model of CO2 sequestration in aqueous solutions of selected waste
Termodynamiczny model sekwestracji CO2 w wodnych roztworach wybranych odpadów
Autorzy:
Uliasz-Bocheńczyk, A.
Cempa, M.
Powiązania:
https://bibliotekanauki.pl/articles/216347.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
odpady mineralne
mineralna sekwestracja CO2
popioły fluidalne
kocioł fluidalny
modelowanie
mineral waste
mineral sequestration of CO2
fluidized ash
fluidized bed
modelling
Opis:
Mineral sequestration using mineral waste is an interesting attempt at combining the solving of two important ecological problems: the reduction of anthropogenic emissions of CO2 by permanent binding and a fuller use of waste with restricted economic applications. The waste used to bind CO2 by way of mineral sequestration should have a high content of CaO and free CaO. Fly ashes from fluidized beds seem interesting in terms of preparing aqueous suspensions to be used in mineral sequestration of CO2. The article presents the results of modelling of the processes occuring in aqueous suspensions as exemplified by suspensions prepared on the basis of fluidized ashes from the power plant in Tychy subjected to the effects of CO2. The selection of these suspensions was based on the results of previous research. The thermodynamic model presented in the article is an attempt to identify the kind and order of occurrence of chemical reactions leading to permanent binding of carbon dioxide observed in aqueous ash suspensions subjected to the effects of CO2. The elaborated model confirmed both the complexity of themineral sequestration process in this kind of waste and the results of research conducted by other authors.
Mineralna sekwestracja przy zastosowaniu odpadów mineralnych jest interesującą próbą połączenia dwóch ważnych problemów ekologicznych: redukcji antropogenicznej emisji CO2 poprzez jego trwałe wiązanie oraz pełniejszego wykorzystania odpadów o ograniczonym zastosowaniu gospodarczym. Do wiązania CO2 poprzez mineralną sekwestrację powinny być stosowane odpady o wysokiej zawartości CaO i wolnego CaO. Interesującymi odpadami do sporządzania zawiesin wodnych do zastosowania ich dla mineralnej sekwestracji CO2 są popioły fluidalne. W artykule przedstawiono wyniki modelowania dotyczące procesów zachodzących w zawiesinach wodnych na przykładzie zawiesin sporządzonych z popiołem fluidalnym z Ec. Tychy poddanych działaniu CO2. Zawiesiny te wybrano na podstawie wyników wcześniejszych badań. Przedstawiony w artykule model jest próbą identyfikacji rodzaju i kolejności reakcji chemicznych w wodnych zawiesinach popiołowych poddanych działaniu CO2 prowadzących do trwałego wiązania ditlenku węgla. Wykonane modelowanie potwierdziło złożoność procesu mineralnej sekwestracji oraz wyniki badań innych autorów.
Źródło:
Gospodarka Surowcami Mineralnymi; 2010, 26, 4; 119-131
0860-0953
Pojawia się w:
Gospodarka Surowcami Mineralnymi
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Spalanie węgla kamiennego w powietrzu wzbogaconym tlenem a zanieczyszczenia
Coal combustion in an oxygen-enriched atmosphere vs pollutants
Autorzy:
Kowalik, M.
Zajemska, M.
Powiązania:
https://bibliotekanauki.pl/articles/283506.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
spalanie w powietrzu wzbogaconym tlenem
węgiel kamienny
kocioł fluidalny
numeryczne modelowanie
emisja zanieczyszczeń
combustion in oxygen-enriched atmosphere
coal
CFB boiler
numerical modeling
emission of pollutants
Opis:
Obecnie zdecydowana większość państw opiera swój przemysł energetyczny na źródłach nieodnawialnych. Jednak energetycznemu wykorzystaniu zasobów naturalnych towarzyszy emisja szkodliwych produktów spalania. Rosnąca świadomość negatywnego oddziaływania zanieczyszczeń na środowisko, a przede wszystkim na organizm ludzki doprowadziła do wzrastającej aktywności badań w obszarze technologii spalania, które w znacznym stopniu pozwolą na ograniczenie tworzących się zanieczyszczeń. W niniejszym artykule przedstawiono analizę procesu spalania węgla kamiennego w powietrzu wzbogaconym tlenem w eksperymentalnej komorze fluidalnej. Mając na uwadze wymagania dotyczące ochrony środowiska w kwestii ograniczenia emisji zanieczyszczeń szczególną uwagę zwrócono na problematykę formowania szkodliwych produktów spalania węgla. W celu oszacowania składu chemicznego spalin wykorzystano numeryczne modelowanie. Obliczenia wykonano w najnowszej wersji programu CHEMKIN dla reaktora idealnego wymieszania (PSR), opierając je na zmodyfikowanym mechanizmie GRI- Mech 3.0 obejmującym 152 reakcje chemiczne oraz 46 pierwiastków i związków chemicznych. Przeprowadzone obliczenia pozwoliły na ocenę wpływu składu atmosfery gazowej na stężenie: dwutlenku węgla, tlenków siarki, tlenków azotu i tlenku węgla, a także umożliwiły głębsze poznanie mechanizmów tworzenia się poszczególnych zanieczyszczeń. Otrzymane wyniki badań modelowych przedstawiono graficznie oraz dokonano ich analizy. Zaprezentowane wyniki badań dowodzą, że spalanie węgla kamiennego w powietrzu wzbogaconym tlenem prowadzi do wzrostu stężenia CO2 w spalinach, co pozwala na jego ograniczenie w drodze sekwestracji.
Presently, the energy industries of the vast majority of countries are based on non- renewable sources. However, the use of natural resources in energy production is connected with the emission of harmful combustion byproducts. Growing awareness of the negative impact of pollution on the environment and above all human health, has led to increasing research in the field of combustion technology, which will allow a significantly reduction in farmed pollutants. This article presents an analysis of the process of oxygen-enriched hard coal combustion in a fluidized bed. Bearing in mind the environmental protection requirements concerning the reduction in the emissions of pollutants, this analysis paid particular attention to the problems of the formation of harmful coal combustion byproducts. In order to estimate the chemical content of fumes, numerical modeling was applied. Calculations were conducted using the latest version of the CHEMKIN program for the Perfectly Stirred Reactor (PSR), based on a modified GRI-Mech 3.0 mechanism including 152 chemical reactions and 46 elements and chemical compounds. The conducted calculations allowed this study to assess the impact of the gas atmosphere’s content on the concentration of carbon dioxide, sulfur oxides, nitric oxides and carbon monoxide, while also allowing for a better understanding of the mechanisms forming respective pollutants. The results obtained in the model tests were represented graphically and analyzed. The research results prove that the coal combustion in oxygen-enriched atmosphere leads to CO2 concentration in flue gas increase, what allows to its reduction by the sequestration.
Źródło:
Polityka Energetyczna; 2013, 16, 2; 85-101
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Co-Combustion of Municipal Sewage Sludge and Hard Coal on Fluidized Bed Boiler WF-6
Współspalanie komunalnych osadów ściekowych z węglem kamiennym w kotle fluidalnym WF-6
Autorzy:
Rajczyk, R.
Bień, J.
Palka, H.
Pogodziński, A.
Smorąg, H.
Powiązania:
https://bibliotekanauki.pl/articles/950772.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
municipal sewage sludge
co-combustion
bubbling fluidized bed boiler
osady ściekowe komunalne
współspalanie
kocioł fluidalny
Opis:
According to data of the Central Statistical Office, the amount of sludge produced in municipal wastewater treatment plants in 2010 amounted to 526000 Mg d.m. The forecast of municipal sewage sludge amount in 2015 according to KPGO2014 will reach 642400 Mg d.m. and is expected to increase in subsequent years. Significant amounts of sludge will create problems due to its utilization. In order to solve this problem the use of thermal methods for sludge utilization is expected. According to the National Waste Management Plan nearly 30% of sewage sludge mass should be thermally utilized by 2022. The article presents the results of co-combustion of coal and municipal sewage sludge in a bubbling fluidized bed boiler made by SEFAKO and located in the Municipal Heating Company in Morag. Four tests of hard coal and sewage sludge co-combustion have been conducted. Boiler performance, emissions and ash quality were investigated.
Według danych GUS w 2010 r. ilość osadów ściekowych wytworzonych w oczyszczalniach komunalnych wyniosła 526,1 tys. Mg s.m. Natomiast prognozowana wg KPGO2014 na 2015 r. ilość suchej masy komunalnych osadów ściekowych osiągnie poziom 642,4 tys. Mg i będzie dalej zwiększać się w kolejnych latach. Znaczne ilości osadów będą stwarzać problemy w ich zagospodarowaniu. W celu rozwiązania tego problemu stawia się na wykorzystanie termicznych metod unieszkodliwiania osadów. Zgodnie z zapisami Krajowego Planu Gospodarki Odpadami (KPGO2014) przewiduje się wręcz, że w perspektywie do 2022 r. ponad 30% osadów będzie termicznie utylizowane. W artykule przedstawiono wyniki badań procesu współspalania czterech mieszanek na bazie węgla i komunalnych osadów ściekowych przeprowadzonych w kotle fl uidalnym z warstwą pęcherzykową WF-6 produkcji SEFAKO zlokalizowanym w Miejskim Przedsiębiorstwie Energetyki Cieplnej w Morągu. Podczas badań określono towarzyszące temu procesowi emisje, skład powstających popiołów jak również wpływ współspalania na parametry ruchowe kotła.
Źródło:
Archives of Environmental Protection; 2014, 40, 3; 101-113
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the efficiency of the unit based on circulating fluidized bed boiler integrated with three-end high-temperature membrane for air separation
Analiza efektywności układu kotła cyrkulacyjnego typu oxy z membraną wysokotemperaturową typu three-end do separacji powietrza
Autorzy:
Kotowicz, J.
Balicki, A.
Powiązania:
https://bibliotekanauki.pl/articles/172915.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
kocioł fluidalny
membrana typu three-end
separacja powietrza
fluidized boiler
three-end membrane
air separation
Opis:
W artykule analizie poddano kocioł z cyrkulacyjnym złożem fluidalnym. Do spalania węgla brunatnego w kotle użyto tlenu wytworzonego w wysokotemperaturowej membranie typu three-end. Pokazano sposób określenia powierzchni membran oraz energochłonności procesu membranowej separacji powietrza. Sprawność termiczną kotła, energochłonność membranowej separacji powietrza i powierzchnię modułu membranowego wyznaczono w funkcji odzysku tlenu w membranie. Zaproponowano wykorzystanie azotu z instalacji separacji powietrza do suszenia węgla. Dla takiego wariantu również wyznaczono charakterystyki układu. Stwierdzono, że przy wykorzystaniu azotu do suszenia sprawności termicznej kotła rośnie z 76% do 87%, przy wzroście stopnia odzysku tlenu od 0,45 do 0,9, i jest wyższa odpowiednio od 12% do 6% w porównaniu do układu bez suszenia. W zaproponowanym układzie separacji powietrza powierzchnia modułu membranowego zawiera się w przedziale 76,5-95,0 tys. m².
In this paper boiler with circulating fluidized bed was analyzed. For the combustion of lignite in the boiler oxygen produced in the three-end high-temperature membrane was used. Paper shows a method of determining the surface of the membranes and energy consumption of the air separation process. Boiler thermal efficiency, energy consumption of the process and air separation membrane module surface was determined as a function of oxygen recovery in the membrane. Nitrogen from the air separation unit was proposed to be used for drying lignite. For this variant characteristics of the system were determined. It was found that the thermal efficiency of the boiler in case where nitrogen was used for lignite drying increased from 76% to 87% with increasing value of oxygen recovery ratio from 0.45 to 0.9 and is higher, respectively, from 12% to 6% in comparison to the system without drying. In the proposed air separation unit required membrane surface is in the range 76500-95000 m².
Źródło:
Archiwum Energetyki; 2012, 42, 2; 59-71
0066-684X
Pojawia się w:
Archiwum Energetyki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Uszkodzenie wykładziny ceramicznej oddzielacza popiołu kotła fluidalnego na skutek współspalania węgla i biomasy
Damage to the ceramic lining of the ash separator of a fluidized bed boiler resulting from combined combustion of coal and biomass
Autorzy:
Stryszewska, T.
Kańka, S.
Powiązania:
https://bibliotekanauki.pl/articles/163703.pdf
Data publikacji:
2012
Wydawca:
Polski Związek Inżynierów i Techników Budownictwa
Tematy:
kocioł fluidalny
oddzielacz popiołu
okładzina ceramiczna
zniszczenie
przyczyna
fluidized bed boiler
ash separator
ceramic lining
damage
cause
Opis:
W artykule przedstawiono wyniki badań dotyczących określenia przyczyny zniszczenia wykładziny ceramicznej w oddzielaczu popiołu kotła fluidalnego. Szybki postęp degradacji przedmiotowej wykładziny zaobserwowano po wprowadzeniu biomasy jako dodatkowego składnika paliwa energetycznego.
This article presents the results of tests to determine the reasons for damage to the ceramic lining in the ash separator of a fluidized bed boiler. The rapid progress of degradation of the lining was observed after biomass was introduced as an additional component of the combusted fuel.
Źródło:
Przegląd Budowlany; 2012, R. 83, nr 5, 5; 115-118
0033-2038
Pojawia się w:
Przegląd Budowlany
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-10 z 10

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies