Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "JAR" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Comparative studies of coagulation in a batch and continuous mode systems
Badania porównawcze koagulacji w układzie porcjowym oraz przepływowym
Autorzy:
Mołczan, M.
Wolska, M.
Szerzyna, S.
Żółtowska, M.
Wiśniewski, J.
Adamski, W.
Powiązania:
https://bibliotekanauki.pl/articles/205234.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic matter
water treatment
DOC
color
coagulation jar test
UV absorbance
materia organiczna
uzdatnianie wody
kolor
jar test
absorbancja UV
Opis:
Coagulation studies were carried out simultaneously in a batch and continuous mode systems. Four coagulants of varied properties were used. Both test procedures contained the same process phases (rapid mixing, flocculation, sedimentation) and a corresponding coagulant dosage range (1.7–3.3 gAl/m3). In the batch mode test, the raw water composition was stable, while in the continuous mode test it was subject to changes resulting from natural variation in source water properties. The main process effectiveness measures were: color, absorbance at 254 nm, and dissolved organic carbon content. Studies in the batch mode system showed clear linear relationships between coagulant dosage and effectiveness of analyzed water contamination indicators values reduction. Tests in flow conditions confirmed the relationships found in the batch test, albeit with lesser agreement with a linear effectiveness – coagulant dosage model. Due to a comparison of coagulation results from both test systems, it was possible to determine the relationships between coagulation effectiveness obtained in continuous and batch mode systems. The linear relationships obtained show a dependence on current raw water properties and the type of coagulant used. However, in many cases, these relationships do not differ significantly as with respect to analyzed water quality indicators. The general rule is that the effectiveness observed in the continuous mode system is larger than that for the batch mode process, which is justified due to different process conditions. Determining the relationship between coagulation results obtained for different experimental procedures allows for predicting effects of changes in technical systems based on laboratory results.
Prowadzono jednoczesne badania koagulacji w układzie porcjowym oraz przepływowym. Korzystano z czterech koagulantów o zróżnicowanych właściwościach (polimeryzacja, zasadowość, zawartość glinu, koszt zakupu). Obie procedury badawcze zawierały te same fazy procesu (szybkie mieszanie, flokulację, sedymentację) oraz analogiczny zakres dawek koagulantów (1,7-3,3 gAl/m3). W teście porcjowym skład wody surowej był ustalony natomiast w badaniu przepływowym podlegał zmianom wynikającym z naturalnej zmienności charakterystyki ujmowanej wody powierzchniowej. Głównymi wskaźnikami oceny skuteczności procesu były: barwa, absorbancja w 254 nm oraz zawartość rozpuszczonego węgla organicznego. Badania w układzie porcjowym pokazały wyraźne liniowe zależności wiążące dawkę koagulantu ze skutecznością zmniejszania wartości analizowanych wskaźników zanieczyszczenia wody. Badania w warunkach przepływowych potwierdziły prawidłowości odnotowane w układzie porcjowym, jednak przy mniejszej zgodności uzyskanych wyników z liniowym modelem zależności skuteczności procesu od dawki koagulantu. Dzięki zestawieniu wyników koagulacji w obu układach doświadczalnych możliwe było określenie związków skuteczności koagulacji osiąganych w układzie przepływowym i porcjowym. Uzyskane liniowe przebiegi wykazują zależność od aktualnej charakterystyki oczyszczanej wody oraz rodzaju stosowanego koagulantu. Natomiast w wielu wypadkach nie różnią się istotnie w odniesieniu do analizowanych wskaźników jakości wody. Za regułę uznać można większą skuteczność koagulacji obserwowaną w układzie przepływowym wobec układu porcjowego, co znajduje uzasadnienie w różnych warunkach prowadzenia procesu. Ustalanie związków pomiędzy wynikami koagulacji uzyskiwanymi w różnych procedurach badawczych, a w szczególności w układzie porcjowym oraz przepływowym, pozwala na przewidywanie skutków zmian wprowadzanych w układach technicznych w oparciu o efekty doświadczeń laboratoryjnych.
Źródło:
Archives of Environmental Protection; 2018, 44, 3; 99-105
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pulp and Paper Wastewater Treatment with Bottom Ash Using Jar Test
Autorzy:
Pisceselia, Dian F.
Arita, Susila
Agustina, Tuty Emilia
Powiązania:
https://bibliotekanauki.pl/articles/2202330.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
adsorbent
pulp and paper wastewater
bottom ash
jar test
Opis:
The wastewater generated from pulp and paper production still contains pollutants and contaminants, so appropriate and economical materials are needed to reduce pollutants by using adsorbents from bottom ash. This study examined the characteristics of bottom ash and pulp and paper wastewater, the effect of stirring time, stirring speed, and adsorbent activation temperature on decreasing the environmental parameters of wastewater. The synthesis of bottom ash as an adsorbent was carried out by heating at 100 and 200 °C for 1 hour. The wastewater treatment process with maximum yield occurs at a stirring speed of 100 rpm for 50 min. The use of bottom ash without heating as an adsorbent in the pulp and paper wastewater treatment process has reduced TSS 77.5%, COD 85.72%, chloride 26.9%, TDS 1143 ppm, and EC 2180 s/cm, which have met the environmental quality standards.
Źródło:
Journal of Ecological Engineering; 2023, 24, 1; 188--194
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ warunków mieszania na kinetykę usuwania substancji organicznych z wody w procesie magnetycznej wymiany anionowej
Effect of agitation conditions on the kinetics of organic matter removal from water by magnetic anion exchange
Autorzy:
Mołczan, M.
Powiązania:
https://bibliotekanauki.pl/articles/236915.pdf
Data publikacji:
2012
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
wymiana jonowa
naturalne substancje organiczne
test naczyniowy
prędkość mieszania
model kinetyczny
water treatment
ion exchange
natural organic matter
jar test
agitation speed
Opis:
Wykazano, że sposób i intensywność mieszania są istotnymi parametrami procesu wymiany anionowej z użyciem żywicy MIEXŽ, którym dotychczas nie poświęcano wiele uwagi. Dane doświadczalne przedstawiono w postaci krzywych kinetycznych opisanych równaniem reakcji chemicznej pseudo-pierwszego rzędu. Wartości współczynników tego równania posłużyły do interpretacji wyników badań. Uzyskane wyniki badań z użyciem roztworu modelowego zawierającego naturalne substancje organiczne (abs. w UV254nm1m ok. 42, RWO ok. 7,5 gC/m3) potwierdziły, że intensywność mieszania miała istotny wpływ na kinetykę ich usuwania z wody w tym procesie, przy czym jej wpływ na wartość adsorpcji był nieznaczny. Stopniowo zmniejszający się przyrost adsorpcji obserwowany był w całym zakresie badanych intensywności mieszania (100÷300 obr./min). Znacznie istotniejszy był wpływ intensyfikacji mieszania na wzrost szybkości usuwania substancji organicznych. Zależność ta miała charakter liniowy w całym zakresie badanych intensywności mieszania, w którym odnotowano wzrost szybkości reakcji o 80÷90%, w zależności od zastosowanego wskaźnika zawartości substancji organicznych w wodzie (RWO, barwa, absorbancja w nadfiolecie).
Despite their significance in the anion exchange process involving a MIEXŽresin, the mode and speed of agitation have rarely been addressed in the literature. Experimental data were presented in the form of kinetic curves described by the equation of the pseudo-first order chemical reaction. The values of the coefficients of this equation were used for interpreting the results of the study. The results obtained with a model water solution containing natural organic substances (color, about 55 gPt/m3; absorption at UV254nm1m, about 42; DOC, about 7.5 gC/m3) have revealed that agitation speed largely contributed to the kinetics of natural organic matter removal in the MIEXŽ resin process, but only slightly affected the value of adsorption. Gradual decline in the increment of adsorption was observed over the entire range of the agitation speed tested (100 to 300 rpm). Far more significant was the effect of agitation speed on the rate of organic matter removal. This relation was a linear one within the whole agitation speed range examined, where the reaction rate increased by 80 to 90%, depending on the parameter that describes the organic matter content of the water (DOC, color, UV absorbance).
Źródło:
Ochrona Środowiska; 2012, 34, 4; 9-16
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies