Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "exposure dose" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Expression of cellular isoform of prion protein on the surface of peripheral blood lymphocytes among women exposed to low doses of ionizing radiation
Autorzy:
Klucinski, P
Mazur, B.
Hrycek, A.
Masluch, E.
Cieslik, P.
Kaufman, J.
Martirosian, G.
Powiązania:
https://bibliotekanauki.pl/articles/50336.pdf
Data publikacji:
2007
Wydawca:
Instytut Medycyny Wsi
Tematy:
blood lymphocyte
ionizing radiation
low dose
lymphocyte
cellular isoform
woman
radiation exposure
expression
prion protein
Opis:
Ionizing radiation affects the expression of adhesive and co-stimulatory molecules in lymphocytes. The physiological function of cellular isoform of prion protein (PrPc) is little known. Evidences indicate a link between lymphocytes activation and PrPc expression on their surface; however, no direct effect of radiation on PrPc level in these cells was investigated. The objective of this study was to determinate the effect of low doses of ionizing radiation on the expression of PrPc on the surface peripheral blood lymphocytes in the women operating X-ray equipment. In 36 female workers and 30 persons of the control group the PrPc expression on CD3 (T lymphocytes), CD4 (T helper), CD8 (T cytotoxic) and CD19 (B lymphocytes), as well as the percentage of lymphocytes with PrPc on their surface, were tested. Subgroups with respect to age and length of employment were selected. A signifi cant increase was observed in PrPc expression on CD3 and CD4 with lowered PrPc level on CD8 and percentage of CD8 cells with PrPc in workers compared to control. The PrPc level did not show signifi cant changes in subgroups in relation to age (below and over 40 years old) both in the investigated and control groups, whereas a lower percentage of PrPc expressing CD19 cells showed in employed women below 40 years of age. A signifi cant decrease was found in PrPc expression on the surface of CD3, CD4 and CD8 cells in the subgroup employed for over 10 years than in the subgroup with less than 10 years of employment.
Źródło:
Annals of Agricultural and Environmental Medicine; 2007, 14, 2
1232-1966
Pojawia się w:
Annals of Agricultural and Environmental Medicine
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The assessment of the ionizing radiation dose received by patients during some diagnostic X-ray examinations carried out on the basis of the working procedures in the health care entities
Autorzy:
Bekas, M.
Waniewska, E.
Wardzinski, A.
Wieprzowski, K.
Powiązania:
https://bibliotekanauki.pl/articles/874288.pdf
Data publikacji:
2017
Wydawca:
Narodowy Instytut Zdrowia Publicznego. Państwowy Zakład Higieny
Tematy:
assessment
ionizing radiation
radiation dose
patient
diagnostic method
X-ray method
radiation exposure
working procedure
health care
human health
health risk
Opis:
Background. X-ray examination is a popular and universally used injury and disease diagnostic method. A distinctive X ray examination feature is that it can be done quickly which is extremely important in case of the need for rapid diagnosis of patients in life threatening condition. Another advantage of the X-ray examinations is also relatively low cost of carry. However, X-ray examination involve adverse health effects. During the examination the patient is subjected to ionizing radiation that might have impact on his health. Objective. The aim of this study has been to determine and assess the size of the entrance surface doses (ESD) received by patients during selected X-ray examinations performed on the basis of the medical working procedures available in healthcare entities in Masovian Voivodeship in Poland. Materials and Method. The examinations were conducted for 71 X-ray units located in the Masovian Voivodeship. Measurements of doses received by the patients were based on our own validated test methods. Results. It was found that the range applied to the high voltage in healthcare entities does not always coincide with the values specified in the standard procedures. It was found in the skull projection radiography AP and LAT that the recorded values were from range 60 to 82 kV (the average value of 74 kV) while in accordance with a standard procedure they should be in the range from 65 to 75 kV. Only in case of cervical spine radiography in the AP projection, the LAT exposure conditions were matching with the standard obligatory procedures in Poland. The consequence of selecting exposure conditions are significant differences in the size of the doses the patient receive during the same medical procedures. The greatest range of ESD doses was found during radiography of the thoracic spine in the projection AP and LAT. The projection LAT measured values were in the range of 523 to 10550 μGy (average value 2175 μGy). Conclusions. It is necessary to update immediately the standard procedures and to develop detailed guidelines for the preparation of working procedures in X-ray rooms.
Wprowadzenie. Badania rentgenowskie są powszechnie stosowaną metodą diagnozowania urazów i schorzeń występujących u pacjentów. Największą zaletą tych badań jest szybkość ich wykonania, co jest niezwykle istotne w przypadku konieczności postawienia szybkiej diagnozy medycznej u pacjentów w ciężkim stanie zagrażającym ich życiu. Badania rentgenowskie niosą jednakże ze sobą także negatywne skutki zdrowotne. W trakcie ich przeprowadzania pacjent poddany jest działaniu promieniowania jonizującego, które nie jest obojętne dla zdrowia. Cel. Celem badań było oszacowanie wielkości wejściowej dawki powierzchniowej (ESD) jaką otrzymują pacjenci podczas wybranych badań rentgenowskich przeprowadzonych w oparciu o procedury robocze obowiązujące w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Materiał i metody. Zbadano 71 aparatów rentgenowskich wykorzystywanych w placówkach ochrony zdrowia na terenie województwa mazowieckiego. Pomiary dawek otrzymywanych przez pacjentów podczas badań rentgenowskich przeprowadzono własnymi zwalidowanymi metodami badawczymi. Wyniki. Stwierdzono, iż zakres wartości wysokiego napięcia dobieranego przez personel medyczny na aparatach rentgenowskich w placówkach ochrony zdrowia nie zawsze pokrywa się z wartościami określonymi w procedurach wzorcowych. Stwierdzono, iż w radiografii czaszki w projekcji AP i LAT wartość wysokiego napięcia była od 60 do 82 kV (wartość średnia 74 kV), zaś zgodnie z procedurą wzorcową powinny mieścić się w zakresie od 65 do 75 kV. Najlepszą zgodność pomiędzy wartościami wysokiego napięcia stosowanymi w pracowniach rtg a tymi określonymi w procedurach wzorcowych obowiązujących w Polsce stwierdzono w przypadku radiografii kręgosłupa szyjnego. Konsekwencją tak dobieranych warunków ekspozycji są znaczące różnice w wielkości dawek promieniowania otrzymywanych przez pacjentów dla tych samych procedur medycznych. Największą rozpiętość dawek ESD stwierdzono w trakcie radiografii kręgosłupa piersiowego w projekcji AP oraz LAT. W projekcji LAT zmierzone wartości były w przedziale od 523 do 10550 μGy (wartość średnia 2175 μGy). Wnioski. Niezbędne jest jak najszybsze uaktualnienie procedur wzorcowych oraz opracowanie szczegółowych wytycznych dotyczących przygotowywania procedur roboczych w pracowniach rentgenowskich.
Źródło:
Roczniki Państwowego Zakładu Higieny; 2017, 68, 1
0035-7715
Pojawia się w:
Roczniki Państwowego Zakładu Higieny
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies