Tytuł:
Role of intraoperative neuromonitoring of the recurrent laryngeal nerves during thyroid reoperations of recurrent goiter
Autorzy:
Sopiński, Jan
Kuzdak, Krzysztof
Hedayati, Masoud
Kołomecki, Krzysztof
Powiązania:
https://bibliotekanauki.pl/articles/1393574.pdf
Data publikacji:
2017
Wydawca:
Index Copernicus International
Tematy:
recurrent goiter
recurrent laryngeal nerve
intraoperative neuromonitoring
Opis:
Reoperations of the thyroid gland are challenging to any surgeon. Such procedures are technically difficult and involve higher risk of complications than primary procedures. Recurrent laryngeal nerve (RLN) palsy is one of such complications The aim of the study was to evaluate the effectiveness of intraoperative neuromonitoring (IONM) in preventing RLN palsy during recurrent goiter operations. Material and methods. We retrospectively analyzed the results of thyroid reoperation performed at the Department of Endocrine, General and Vascular Surgery of Medical University of Lodz in the period from January 2014 to June 2016. The study included 80 patients, who were divided into 2 groups: group A consisted of 27 patients, who had undergone surgery with the use of IONM, while group B included 53 patients, in whom RLN was identified visually. During statistical analysis we took into account the number of nerves at risk, not the number of patients. There were 47 nerves at risk In group A and 86 in group B. We analyzed whether application of IONM had any effect on the frequency of RLN palsy and procedure duration. Results. The frequency of RLN palsy was 10.64% (5/47) in group A and 15.12% (13/86) in group B (no statistical significance, p=0,47). Mean operation time was shorter in group B 71.29 ± 17.125 minutes vs. 75.75 ± 17.94 minutes in group A (no statistical significance, p=0,377). Conclusion. Use of IONM did not significantly reduce the occurrence of RLN palsy and procedure duration.
Źródło:
Polish Journal of Surgery; 2017, 89, 3; 11-15
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of the Learning Curve for Intraoperative Neural Monitoring of the Recurrent Laryngeal Nerves in Thyroid Surgery
Autorzy:
Pragacz, Krzysztof
Barczyński, Marcin
Powiązania:
https://bibliotekanauki.pl/articles/1396001.pdf
Data publikacji:
2015-03-01
Wydawca:
Index Copernicus International
Tematy:
thyroid surgery
intraoperative neuromonitoring
recurrent laryngeal nerve
Opis:
Intraoperative neuromonitoring facilitates identification of the recurrent laryngeal nerves (RLN) and allows for predicting their postoperative function. Nevertheless, the outcome of thyroid surgery monitoring is affected by both the experience of the operator and his mastering of the technique. The aim of the study was the assessment of the learning curve for intraoperative RLN neuromonitoring. Material and methods. The prospective analysis included 100 consecutive thyroid operations performed by a single surgeon during implementation of RLN neuromonitoring in a district surgical ward in Staszów. RLN neuromonitoring was performed in keeping with the recommendations of the International Neural Monitoring Study Group using a C2 NerveMonitor (Inomed, Germany). The outcomes of initial 50 procedures (group I: 08/2012-07/2013) were compared with the results of subsequent 50 operations (group II: 08/2013-07/2014). The evaluation included demographic and intraoperative data along with predictive value of the method and complications. Results. In group II as compared to group I, a significant reduction of operative time was noted (102.1±19.4 vs 109.9±19; p=0.045), along with an increased percentage of identified RLNs (99% vs 89.2%; p=0.006), a decreased percentage of correction-requiring technical errors (8% vs 24%; p=0.029), an improved negative predictive (99% vs 89.3%; p<0.001) and positive value (75% vs 55.6%; p<0.001), as well as a decreased percentage of RLN injuries (3% vs 14%; p=0.006). Conclusions. Mastering the technique of intraoperative RLN neuromonitoring in thyroid surgery requires the surgeon to perform independently approximately 50 monitored procedures, what allows for achieving the predictive value of the method that is comparable to outcomes published by referral centers.
Źródło:
Polish Journal of Surgery; 2014, 86, 12; 584-593
0032-373X
2299-2847
Pojawia się w:
Polish Journal of Surgery
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Does neuromonitoring affect voice quality in patients subjected to a complete thyroidectomy ?
Autorzy:
Bryk, Piotr
Głuszek, Stanislaw
Powiązania:
https://bibliotekanauki.pl/articles/23203211.pdf
Data publikacji:
2021-05-12
Wydawca:
Index Copernicus International
Tematy:
intraoperative neuromonitoring
recurrent laryngeal nerve
vocal cord
thyroidectomy
voice assessment
voice quality
Opis:
Introduction: Voice dysfunction is the most common complication of thyroid surgery. The use of intraoperative neuromonitoring (IONM) is to protect the recurrent laryngeal nerves, the damage of which causes voice dysfunction. Aim: The aim of the study was to evaluate voice quality in patients who underwent complete thyroidectomy operated on with the application of IONM as well as a group of patients operated on with only macroscopic nerve visualization. In the analysis, clinical voice assessment was performed with particular focus on voice efficiency using the Voice Handicap Index (VHI), Vocal Tract Discomfort (VTD) and GRBAS scale. Material and methods: The study group consisted of 205 patients operated on with IONM. The control group consisted of 162 patients subjected to surgery only with macroscopic visualization of recurrent laryngeal nerves, without IONM. During the follow-up period from 2 to 10 years after surgery, checkups were performed. Each patient who came for a checkup was subjected to perceptual voice evaluation with the use of the GRBAS scale, indirect laryngoscopy procedure and voice selfevaluation with two questionnaires (VHI and VTD). Results: The frequency of vocal fold palsy did not differ significantly statistically in the study group and the control group. Both in the study group and in the control group, patients with vocal fold paralysis had statistically significantly higher results in the VHI and VTD questionnaires as well as in the GRBAS study. Conclusion: Patients with recurrent laryngeal nerve injury show significant differences in the scope of voice handicap, both in the voice quality assessment with the use of the GRBAS scale, and self-evaluation questionnaires: VHI and VTD. All voice disorders evaluated with self-assessment are medium voice disability
Źródło:
Polish Journal of Otolaryngology; 2021, 75, 5; 16-23
0030-6657
2300-8423
Pojawia się w:
Polish Journal of Otolaryngology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies