Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Pietek, G." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Contaminants of post-leaching copper solutions and their behavior during extraction with industrial extractants
Autorzy:
Gotfryd, L.
Pietek, G.
Powiązania:
https://bibliotekanauki.pl/articles/109816.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
industrial copper extractants
copper contaminants
copper extraction isotherms
Opis:
Several copper extractants have been examined in laboratory glassware with a special attention paid to their behavior towards cations others than copper(II). In the studies 25 vol. percent of hydrocarbon (Exxsol D80 AZ) solutions of six industrial copper extractants have been used. They were mainly rea-gents of hydrooxime type (LIX 860N-IC, LIX 984, LIX 984N, LIX 84-I, Acorga M5640) and diketone type LIX 54-100. Individual isotherms of independent extraction of copper(II) and selected cations (Fe3+, Fe2+, Co2+, Ni2+, Zn2+, Mn2+, Cd2+, Mg2+) versus equilibrium pH have been compared. Investigations have been conducted with synthetic 0.1 mol/L solutions of their sulfates. The values of pH50% − parameter defined as an equilibrium pH at the moment of half-and-half extraction of the investigated cationic spe-cies have been presented. Also ΔpH50%, that is differences between values of pH50% for specific cation Me(II) and copper(II): ΔpH50% = pH50%(Me) − pH50%(Cu), have been given. In addition to that 25% LIX 984 has been used in counter-current pilot trials for copper(II) extraction from naturally contaminated solutions produced by bioleaching of industrial sulfide copper concentrate to observe behavior of investi-gated contaminants such as correlations between their real co-extraction with copper(II) and the position of their extraction on the pH scale. Copper electrolyte/strip solution, working alternately within close loop of coupled stripping - electrowinning system, has been analyzed during consecutive cycles to observe building up of the contaminants concentrations in the course of test.
Źródło:
Physicochemical Problems of Mineral Processing; 2013, 49, 1; 133-143
1643-1049
2084-4735
Pojawia się w:
Physicochemical Problems of Mineral Processing
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies