Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Hamada, E." wg kryterium: Autor


Wyświetlanie 1-1 z 1
Tytuł:
Gamma-ray computed tomography SCANNERS for applications in multiphase system COLUMNs
Autorzy:
Calvo, W. A. P.
Hamada, M. M.
Sprenger, F. E.
Vasquez, P. A. S.
Rela, P. R.
Martins, J. F. T.
de Matos Pereira, J. C. S.
Omi, N.
de Mesquita, C. H.
Powiązania:
https://bibliotekanauki.pl/articles/148082.pdf
Data publikacji:
2009
Wydawca:
Instytut Chemii i Techniki Jądrowej
Tematy:
industrial computed tomography
multiphase flow systems
non-destructive testing
gas absorption column
industrial process optimization
packed distillation columns
scanning systems
Opis:
Gamma-ray tomography experiments have been carried out to detect spatial patterns in the porosity, in a 0.27 m diameter packed steel column using a first generation computed tomography (CT) system. The CT scanner consists of a NaI(Tl) detector 5.08 cm in diameter, and an encapsulated 137Cs (3.7 GBq) radioactive source, located opposite to the center of the detector. The detector and the source, mounted on a fixed support and the column, can rotated and dislocate by two stepping motors controlled through a microprocessor. Different sizes of stainless steel Raschig rings (12.6, 37.9 and 76 mm) have been examined. The primary objective of this work is to detect spatial patterns and statistical information on porosity variation in packed distillation columns. Horizontal scans, at different vertical positions of the packed bed were made for each size of Raschig rings. Radial porosity variation within the packed bed has been determined. This study has demonstrated that the porosity and its spatial distribution in a metallic packed column can be measured with adequate spatial resolution using the gamma-ray tomography technique. After validation of this first generation CT, the turntable design to rotate and dislocate the 60Co or 137Cs sealed gamma-ray sources and multidetector array for the third generation industrial computed tomography was also developed.
Źródło:
Nukleonika; 2009, 54, 2; 129-133
0029-5922
1508-5791
Pojawia się w:
Nukleonika
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies