Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "drive system" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Predictive speed control of induction drive with high-frequency torsional oscillation
Autorzy:
Serkies, P. J.
Szabat, K.
Dybkowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/97503.pdf
Data publikacji:
2010
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
induction motor
driveline
two-mass drive system
MPC
Opis:
In the paper issues related to the use of model predictive control (MPC) of the drive system with an elastic coupling and an induction motor are presented. After a short introduction the mathematical model of the driving motor with a vector control structure and the two-mass drive system are described. Then, the idea of the MPC is introduced. Next the exact formulation of the MPC for a two-mass drive system is shown. In the MPC algorithm the constraints of the inner and control variables are taken into consideration. The results obtained in the simulation study confirm the correct work of the investigated structure.
Źródło:
Computer Applications in Electrical Engineering; 2010, 8; 120-131
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The equivalent circuit of specially designed induction motor for a main drive system of polymerization reactor
Autorzy:
Rusek, A.
Powiązania:
https://bibliotekanauki.pl/articles/1372702.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
reaktor polimeryzacji
układ napędowy
schemat zastępczy
induction motor
polymerization reactor
drive system
equivalent circuit
Opis:
In the paper a construction of specially designed induction motor for a main drive system of polymerization reactor taking into account the power loss in large-size slide bearing made of sintered carbides is described. The constructional details of motor-bearing set allowing for vertical operation of motor are also given (1), (2). The analysis of power distribution taking into account a slide friction loss in bearing is presented. Resistances of equivalent circuit secondary part as additional vertical branches are determined. The equations describing specially designed induction motor for drive system of polymerization reactor are given. In the equations the loss in large-size slide bearing is taken into account. The equations allow determining static characteristics of the motor. Moreover, in equivalent circuit the phenomenon of agglutination of rotor with stator is taken into account as a result of polymerization phases in reactor chamber where the motor is placed.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2011, 4, 92; 103-108
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energooszczędny układ napędowy
Energy-Saving Drive System
Autorzy:
Bernatt, Jakub
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2091707.pdf
Data publikacji:
2022
Wydawca:
Wydawnictwo Druk-Art
Tematy:
silnik synchroniczny
silnik indukcyjny
układ napędowy wolnoobrotowy
gabaryt
sprawność
synchronous motor
induction motor
low-speed drive system
dimensions
Opis:
Moment znamionowy maszyny elektrycznej determinuje jej gabaryt. Maszyny wolnoobrotowe mają większą objętość i masę od maszyn o tej samej mocy znamionowej, lecz wyższej znamionowej prędkości obrotowej. Sprawność energetyczna maszyny obciążonej mocą znacznie mniejszą od mocy znamionowej ma także sprawność mniejszą od znamionowej. Porównano sprawność energetyczną trzech układów napędowych napędzających maszynę roboczą z prędkością obrotową n = 187,5 obr./min. Wykazano, że sprawność silnika synchronicznego o liczbie par biegunów p = 16 w warunkach pracy wynosi η = 77% i jest mniejsza o 16% od sprawności silnika synchronicznego i silnika indukcyjnego o liczbie par biegunów p = 2 plus przekładnie mechaniczne o przełożeniu i = 8. Silniki synchroniczny i indukcyjny, o liczbie par biegunów p = 2 plus przekładnie mechaniczne o przełożeniu i = 8 stanowią napęd alternatywny do silnika synchronicznego wolnoobrotowego o liczbie par biegunów p = 16.
The rated torque of the electric machine determines its dimensions. Slow-running machines have a larger volume and weight than machines with the same rated power but higher rated rotational speed. The energy efficiency of the machine loaded with power significantly lower than the rated power also has the efficiency lower than the rated one. The energy efficiency of three drive systems driving a working machine with a rotational speed of n = 187,5 rpm was compared and it was shown that the efficiency of a synchronous motor with the number of p = 16 poles under operating conditions is η = 77% and is 16% lower than that of a synchronous motor and an induction motor with the number of pole pairs p = 2, plus mechanical gears with the ratio i = 8. Synchronous and induction motors with the number of pole pairs p = 2 plus mechanical gears with the ratio i = 8 constitute an alternative drive to the slow-speed synchronous motor with the number of pole pairs p = 16
Źródło:
Napędy i Sterowanie; 2022, 24, 1; 30--35
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energooszczędny układ napędowy
Energy-saving drive system
Autorzy:
Bernatt, Jakub
Glinka, Tadeusz
Polak, Artur
Powiązania:
https://bibliotekanauki.pl/articles/2056403.pdf
Data publikacji:
2021
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik synchroniczny
silnik indukcyjny
układ napędowy wolnoobrotowy
gabaryt
sprawność
synchronous motor
induction motor
low-speed drive system
dimensions
efficiency
Opis:
Moment znamionowy maszyny elektrycznej determinuje jej gabaryt. Maszyny wolnoobrotowe mają większą objętość i masę od maszyn o tej samej mocy znamionowej lecz wyższej znamionowej prędkości obrotowej. Sprawność energetyczna maszyny obciążonej mocą znacznie mniejszą od mocy znamionowej ma także sprawności mniejszą od znamionowej. Porównano sprawność energetyczną trzech układów napędowych napędzających maszynę roboczą z prędkością obrotową n = 187,5 obr/min i wykazano, że sprawność silnika synchronicznego o liczbie par biegunów p = 16, w warunkach pracy, wynosi η = 77% i jest mniejsza o 16% od sprawności silnika synchronicznego i silnika indukcyjnego, o liczbie par biegunów p = 2, plus przekładnie mechaniczne o przełożeniu i = 8. Silniki synchroniczny i indukcyjny, o liczbie par biegunów p = 2, plus przekładnie mechaniczne o przełożeniu i = 8 stanowią napęd alternatywny do silnika synchronicznego wolnoobrotowego o liczbie par biegunów p = 16.
The rated torque of the electric machine determines its dimensions. Slow-running machines have a larger volume and weight than machines with the same rated power but higher rated rotational speed. The energy efficiency of the machine loaded with power significantly lower than the rated power also has the efficiency lower than the rated one. The energy efficiency of three drive systems driving a working machine with a rotational speed of n = 187.5 rpm was compared and it was shown that the efficiency of a synchronous motor with the number of p = 16 poles under operating conditions is η = 77% and is 16% lower than that of a synchronous motor and an induction motor with the number of pole pairs p = 2, plus mechanical gears with the ratio i = 8. Synchronous and induction motors with the number of pole pairs plus p = 2 mechanical gears with the ratio i = 8 constitute an alternative drive to the slow-speed synchronous motor with the number of pole pairs p = 16.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2021, 2, 126; 29--34
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rozkład obciążeń między silniki napędzające przenośnik taśmowy
Load distribution between the belt conveyor drive motors
Autorzy:
Karolewski, B.
Ligocki, P.
Powiązania:
https://bibliotekanauki.pl/articles/170943.pdf
Data publikacji:
2014
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
przenośniki taśmowe
układ napędowy
silnik klatkowy
przeciążenie
model matematyczny
rozruch
belt conveyors
drive system
induction motor
overload
mathematical model
starting
Opis:
Wykorzystując rozbudowany matematyczny model przenośnika taśmowego wyznaczano momenty elektromagnetyczne dwóch silników napędzających wspólny bęben napędowy przenośnika. Uwzględniono możliwość wystąpienia różnic pomiędzy parametrami silników oraz przesunięcia czasu załączenia jednego z nich. Badano również przypadek współpracy silników z przemiennikami częstotliwości pracującymi w otwartym układzie sterowania. Uwzględniono różnice przebiegów ramp rozruchowych obu przemienników. Symulacje pozwalają ocenić stopień przeciążenia silnika i dopuszczalność rozruchu w danych warunkach.
Using extensive belt conveyor mathematical model, electromagnetic moments of the two engines driving a common drive drum of the conveyor were determined. Taken into account the possibility of differences between the parameters of the motors and the time shift switch one of them. Were also investigated case of cooperation between motors with frequency converters operating in open loop. Allowances for differences starter ramp waveforms both drives. The simulations allow us to assess the degree of overload and start acceptability under given conditions.
Źródło:
Górnictwo Odkrywkowe; 2014, 55, 4-5; 167-171
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka silników indukcyjnych klatkowych w układach napędowych wagonów tramwajowych
The diagnostics of cage induction motors in drive systems of tram wagons
Autorzy:
Sułowicz, M.
Czechowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/1197463.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
silnik indukcyjny
wagon tramwajowy
diagnostyka uszkodzeń
układ napędowy tramwaju
uszkodzenia elektryczne
uszkodzenia mechaniczne
induction motor
tram wagon
damage diagnostics
tram drive system
electrical faults
mechanical faults
Opis:
The paper presents the results of research conducted on cage induction motors in tram wagons. The research involved several dozens of motors operating in several tram wagons of a local city transport organization. The diagnostic experiment was performed in two different seasons of the year using the Rogowski coil's, data acquisition cards and dedicated computer programs. The acquired data were then subject to a detailed analysis followed by a thorough evaluation of their performance. The analysis of the registered data during test drives allowed the authors to estimate the condition of the motors based on the information gained in both transient and steady-state states. The authors selected optimum analysis tools and developed algorithms for diagnostic evaluation. Based on the analysis data the authors formulated a procedure for conditionmonitoring of the motors in tram wagons during test drives. The developed method will be useful for evaluating the conditions of tram wagons and scheduling their maintenance. The procedure can be adapted for evaluating the condition of cage induction motors in other types of vehicles.
W artykule przedstawiono doświadczenia autorów z przeprowadzonych badań diagnostycznych silników indukcyjnych klatkowych napędów wagonów tramwajowych. Badania diagnostyczne przeprowadzono na kilkudziesięciu silnikach pracujących w kilku wagonach tramwajowych w jednym z przedsiębiorstw komunikacyjnych. Pomiary diagnostyczne, z wykorzystaniem cewek Rogowskiego, karty pomiarowej i dedykowanego oprogramowania wykonano w dwóch różnych porach roku. Zebrane dane pomiarowe poddano szczegółowej analizie i dokonano oceny stanu poszczególnych badanych silników. Analizy zarejestrowanych sygnałów podczas jazd testowych pozwoliły na ocenę stanu silników na podstawie pozyskanych informacji ze stanu ustalonego, jaki i stanów dynamicznych pracy tych maszyn. Wybrano najskuteczniejsze metody analizy i opracowano algorytmy oceny diagnostycznej. W oparciu o przeprowadzone analizy sformułowano procedurę badań diagnostycznych, która pozwoli na wiarygodną ocenę stanu silników podczas jazd kontrolnych. Wypracowana metoda będzie przydatna w przedsiębiorstwie do typowania maszyn do remontu, jak i kontroli stanu maszyn po wykonanych zabiegach remontowych. Opracowane procedury badań mogą zostać również zaadaptowane do oceny stanu silników indukcyjnych klatkowych w napędach innych pojazdów niż wagony tramwajowe.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 3, 119; 189-195
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
System do ciągłej diagnostyki silników indukcyjnych klatkowych pracujących w układach napędowych wagonów tramwajowych
System for continuous diagnostics of squirrel cage induction motors operating in the drive systems of tram cars
Autorzy:
Czechowski, Mirosław
Sułowicz, Maciej
Zielonka, Jakub
Tulicki, Jarosław
Stradowski, Michał
Powiązania:
https://bibliotekanauki.pl/articles/2142556.pdf
Data publikacji:
2022
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
diagnostyka uszkodzeń
układ napędowy tramwaju
uszkodzenia elektryczne
uszkodzenia mechaniczne
monitoring
metody diagnostyki
silnik indukcyjny
wagon tramwajowy
kurtoza
kurtogram
damage diagnostics
tram drive system
electrical faults
mechanical faults
diagnostic methods
induction motor
tram wagon
kurtosis
Opis:
W artykule przedstawiono koncepcję budowy i sposób realizacji systemu diagnostycznego do oceny stanu silników indukcyjnych pracujących w układach napędowych wózków wagonów tramwajowych. Przedstawiono najważniejsze założenie, które należy przyjąć przy projektowaniu i zestawieniu układu pomiarowego oraz doborze skutecznych metod diagnostycznych do wykrywania uszkodzeń elektrycznych i mechanicznych w układzie napędowym tramwaju. Przedstawiono opis układu pomiarowego oraz sygnały, które są wykorzystywane w module diagnostycznym. Na bazie doczasowych doświadczeń autorów wybrano metody diagnostyczne, które poprzez analizę sygnałów prądów, napięć i prędkości w dziedzinie czasowo-częstotliwościowej pozwolą na skuteczne wykrywanie uszkodzeń w stanach dynamicznej pracy napędu. Reprezentatywną grupą metod diagnostycznych przedstawioną w artykule jest metoda analizy spektrogramu kurtozy. Podjęte prace są związane z poszukiwaniem nowych skutecznych metod diagnostycznych do wykrywania uszkodzeń natury elektrycznej i mechanicznej występujących w układach napędowych wagonów tramwajowych.
The article presents the concept of construction and the implementation method of a diagnostic system for the assessment of the condition of induction motors operating in the drive systems of trolley carriages. The most important assumption that should be made when designing and setting up the measurement system and selection of effective diagnostic methods for detecting electrical and mechanical damage in the tram drive system was presented. A description of the measuring system and signals used in the diagnostic module are presented. Based on the authors' past experiences, diagnostic methods have been selected which, by analyzing the signals of currents, voltages and speeds in the time-frequency domain, will allow for effective detection of failures in the states of dynamic operation of the drive. A representative group of diagnostic methods presented in the article is the method of kurtosis spectrogram analysis. The work undertaken is related to the search for new, effective diagnostic methods to detect electrical and mechanical damage occurring in the drive systems of tram cars.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2022, 3, 1 (127); 207--213
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Testing the impact of input signals disturbances of PI controllers in a field-oriented control system with an induction motor
Badanie wpływu zakłóceń sygnałów wejściowych regulatorów typu PI w układzie sterowania polowo-zorientowanego z silnikiem indukcyjnym
Autorzy:
Hudy, W.
Jaracz, K.
Powiązania:
https://bibliotekanauki.pl/articles/1361600.pdf
Data publikacji:
2015
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
drive systems
induction motor
reactive power compensation
control system
silnik indukcyjny
układ napędowy
system sterowania
Opis:
W artykule omówiono wpływ jakościowy zakłóceń działających na sygnały wejściowe poszczególnych regulatorów w układzie polowo-zorientowanym, w którym obiektem sterowania prędkością obrotową jest silnik indukcyjny. Nastawy regulatorów PI obliczono przy zastosowaniu algorytmu ewolucyjnego. Badanie dynamiki układu przeprowadzono metodą komputerową, korzystając z oprogramowania MATLAB/Simulink.
The paper discusses the qualitative impact of disturbances which affect input signals of PI controllers in a field-oriented control system. An induction motor is an object for rotational speed control. The settings of PI controllers were calculated with the use of an evolutionary algorithm. The dynamics of the system was tested by a computer method, with the use of the MATLAB/Simulink software.
Źródło:
Mining – Informatics, Automation and Electrical Engineering; 2015, 53, 1; 12-16
2450-7326
2449-6421
Pojawia się w:
Mining – Informatics, Automation and Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Determination of the working energy capacity of the on-board energy storage system of an electric locomotive for quarry railway transport during working with a limitation of consumed power
Autorzy:
Kondratieva, Liliia
Bogdanovs, Arturs
Overianova, Liliia
Riabov, Ievgen
Goolak, Sergey
Powiązania:
https://bibliotekanauki.pl/articles/27311785.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
railway transport
electric locomotive
energy storage system
traction drive
induction motor
transport kolejowy
lokomotywa elektryczna
system magazynowania energii
napęd trakcyjny
silnik indukcyjny
Opis:
The use of specialized rail rolling stock which is used for transporting ore from the quarry to the crushing plant at mining enterprises is analyzed here. Electric locomotives with an asynchronous traction electric drive and an on-board energy storage system are considered for use. The calculated dependencies of the electric locomotive tractive power were analyzed and it was established that on flat sections of the track profile, the movement is carried out with a power that does not exceed 50% of the nominal one. The movement with the nominal power is carried out on the controlled uphill during the cargo half-passage. To ensure the necessary power for movement in such areas, the use of an on-board energy storage system is proposed, which should feed the traction system while limiting the power consumed from the catenary. This happens when the voltage on the pantograph drops to a minimum level. The aim of this work is to determine the on-board energy storage system parameters during the operation of the electric locomotive with limitation of the power consumed from the traction network. Mathematical models of the energy exchange processes in the electric locomotive traction system have been developed. The criteria for comparing options for calculating the parameters of the on-board energy storage system have been proposed. The criteria take into account the reduction of energy consumption during movement, the efficiency of energy storage, and the complete use of the on-board energy storage system in terms of power and working energy capacity. Based on the calculation results, it was determined that the use of an energy storage device with a power of 3,540 kW and an operating energy capacity of 63.5 kWh provides a 10% reduction in energy consumption, which is being consumed while moving along the sample section of the road. The current that can be consumed by an electric locomotive with such parameters of the on-board energy storage system is limited by 600 A.
Źródło:
Archives of Transport; 2023, 65, 1; 119--154
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies