- Tytuł:
- Development and validation of rapid LC-MS with electrospray ionization for the quantification of pramipexole in human plasma
- Autorzy:
-
Lavudu, P.
Rani, A. P.
Sekharan, C. B. - Powiązania:
- https://bibliotekanauki.pl/articles/411617.pdf
- Data publikacji:
- 2014
- Wydawca:
- Przedsiębiorstwo Wydawnictw Naukowych Darwin / Scientific Publishing House DARWIN
- Tematy:
-
Pramipexole
LC-MS
human plasma
bioanalytical metod - Opis:
- A rapid, accurate and precise LC-MS method is described for the quantitative determination of pramipexole in human plasma matrix using ropinirole as internal standard. Pramipexole and ropinirole were extracted from plasma by liquid-liquid extraction technique. The method was validated over the concentration range of 100-2514 pg/mL. The method was found to have acceptable accuracy, precision, linearity and selectivity. The mean extraction recovery from spiked plasma samples was in the range of 79.415-87.00 %. The intra-day accuracy of the assay ranged from 98.924 to 112.236 % and intra-day precision ranged from 3.489 to 6.756 %. Inter-day accuracy and precision results for quality control samples ranged between 100.340 and 107.443% of nominal and precision is observed to be 3.970-5.714 %. The pramipexole was found to be stable after several stability studies. The proposed method yielded a quick, simple and reliable protocol for estimating pramipexole concentrations in human plasma.
- Źródło:
-
International Letters of Chemistry, Physics and Astronomy; 2014, 18; 1-15
2299-3843 - Pojawia się w:
- International Letters of Chemistry, Physics and Astronomy
- Dostawca treści:
- Biblioteka Nauki