Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Noszczyk-Nowak, A." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Acid-base balance parameters and a value of anion gap of arterial and venous blood in Malopolski horses
Autorzy:
Slawuta, P.
Noszczyk-Nowak, A.
Nowakowski, H.
Powiązania:
https://bibliotekanauki.pl/articles/32496.pdf
Data publikacji:
2010
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
acid-base balance
anion gap
arterial blood
venous blood
Malopolska breed
horse
pH
hydrogen carbonate concentration
carbon dioxide molecule pressure
respiratory system
animal disease
liver
Opis:
The comparative study of the acid-base balance (ABB) parameters has been performed on 20 clinically healthy mature Małopolski horses. An arterial blood sample from the facial artery and a sample of venous blood from the external cervical vein were colected from each animal. In the samples tested, the blood pH, pCO₂, tCO₂, HCO₃-, concentration of Na+, K+, Cl-, and a value of the anion gap were determined. The difference among pCO₂, tCO₂, and HCO₃ - in both samples tested was statistically significant, whereas the pH of the arterial blood and the pH of the venous blood did not differ significantly. The anion gap in both types of blood did not differ significantly. Conclusions: 1) ABB parameters such as pCO₂, HCO₃-, and tCO₂ determined in the arterial and venous blood of the Małopolski horses differ from each other significantly. 2) In spite of the lack of the differences between pH of the arterial and venous blood, the ABB parameters in horses should be determined in the arterial blood, because the comparative study performed proves that the analysis of the ABB parameters determined for the venous blood of a healthy horse may lead to a wrong diagnosis of the compensated respiratory acidosis. 3) The mean value of anion gap in horses aged 8-12 years amounts to 20.9 mmol/l for the arterial blood and 19.93 for the venous blood; the difference between the two values is not statistically significant.
Źródło:
Polish Journal of Veterinary Sciences; 2010, 13, 4
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-term and long-term PQ, QT and R-R intervals variability at the resting condition and after exercise testing in healthy Anglo-Arabian horses
Autorzy:
Paslawska, U.
Zysko, D.
Noszczyk-Nowak, A.
Paslawski, R.
Powiązania:
https://bibliotekanauki.pl/articles/30632.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrocardiographic parameter
short-term observation
long-term observation
R-R interval variability
exercise testing
healthy animal
Anglo-Arabian horse
horse
heart
autonomic nervous system
Opis:
The duration of electrocardiographic (ECG) parameters: PQ, QT and R-R intervals change during long-term and short-term observation as the consequence of the fluctuations in autonomic nervous system activity among others dependent on the exercise and resting. There is no data of horse breed influence on these parameters. The aim of the study was to assess the duration and the variability of the PQ, QT and R-R intervals in the resting conditions and after exercise testing in Anglo-Arabian horses. Material and Methods: 27 healthy Anglo-Arabian horses aged 3.4 ± 1.0 years (15 male, 12 female) had ECG examination in the standing position using Einthoven system of leads. The longest and the shortest PQ, QT and R-R intervals were measured after night rest and after exercise testing and the means were calculated. Conclusions: 1) In Anglo-Arabian horses the difference between the longest and the shortest PQ interval at rest vs. after exercise is 0.06 ± 0.05 vs. 0.03 ± 0.02, QT interval is 0.04 ± 0.03 vs. 0.04 ± 0.04, R-R interval 0.19 ± 0.15 vs. 0.08 ± 0.11. 2) The PQ and R-R intervals reveal high short-term variability either at the resting conditions or after exercise testing. 3) After exercise testing PQ, QT and R-R intervals are shorter than at the resting conditions. The delta PQ and R-R are 2 times smaller in contrast to delta QT which is constant. 4) The PQ and R-R interval variability was greater at the baseline condition than after exercise testing. The QT variability was similar at baseline condition to that after exercise testing.
Źródło:
Polish Journal of Veterinary Sciences; 2012, 15, 1
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies