Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Naskalski, Jerzy" wg kryterium: Wszystkie pola


Wyświetlanie 1-1 z 1
Tytuł:
Potentiometric determination of cysteine with thiol sensitive silver-mercury electrode
Autorzy:
Drożdż, Ryszard
Naskalski, Jerzy
Ząbek-Adamska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/1041141.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
potentiometry
cysteine
real time assay
homocysteine
glutathione
Opis:
A potentiometric procedure for cysteine thiol group concentration monitoring in media generating free radicals was developed using a thiol specific silver-mercury electrode. Electrolytic deposition of mercury on a silver wire and treatment with 20 mM cysteine in 0.5 M NaOH were used to produce the electrode. A silver-chloride electrode in saturated KCl was the reference. A glass capillary with 1 M KNO3 in 1% agarose gel was the liquid junction. The electrode responded to cysteine concentration in the range from 0.01 to 20 mM yielding a perfect linear relationship for the dependence of log [cysteine] versus electrode potential [mV], with b0 (constant) = -373.43 [mV], b1 (slope) = -53.82 and correlation coefficient r2 = 0.97. The electrode potential change per decade of cysteine concentration was 57 mV. The minimal measurable signal response was at a cysteine concentration of 0.01 mM. The signal CV amounted to 4-6% for cysteine concentrations of 0.01 to 0.05 mM and to less than 1% for cysteine concentrations of 0.5 to 20 mM. The response time ranged from about 100 s for cysteine concentrations of 0.01 to 0.1 mM to 30 s at higher cysteine concentrations. The standard curve reproducibility was the best at cysteine concentrations from 0.1 to 20 mM. In a reaction medium containing cysteine and copper(II)-histidine complex ([His-Cu]2+) solution in 55 mM phosphate buffer pH 7.4 the electrode adequately responded to changes in cysteine concentration. Beside cysteine, the silver-mercury electrode responded also to thiol groups of homocysteine and glutathione, however, the Nernst equation slope was about half of that for cysteine.
Źródło:
Acta Biochimica Polonica; 2007, 54, 1; 205-211
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies