Research on efficiency of heat recovery in the cross-plate heat exchanger made of plastic
Autorzy:
Sas, S.
Kasprzyk, P.
Powiązania:
https://bibliotekanauki.pl/articles/88926.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Wydział Geoinżynierii, Górnictwa i Geologii. Instytut Górnictwa
Tematy:
heat exchanger
heat recovery
Opis:
The article content the results of study of heat exchanger. Exchanger was made of plastic material: polystyrene. The measurement results were used for efficiency analysis of this type of heat exchanger as an alternative to the commonly used heat exchangers made of aluminum.
Źródło:
Mining Science; 2015, 22, Special Issue 2; 151-159
2300-9586
2353-5423
Pojawia się w:
Mining Science
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mathematical model and measurements of a combi-steamer condensation hood
Autorzy:
Tokarski, Mieszko
Ryfa, Arkadiusz
Buliński, Piotr
Rojczyk, Marek
Ziarko, Krzysztof
Nowak, Andrzej J.
Powiązania:
https://bibliotekanauki.pl/articles/240444.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy balance
heat transfer
heat exchanger
condensation
condensation hood
Opis:
Combi-steamer condensation hoods are widely used in modern gastronomy. They condense steam produced by the combi-steamer and also filter solid particles, moisture, grease and smells. All these factors negatively affect the staff and dishes, so efficient work of the condensation hoods becomes important. A mathematical and experimental analysis of such a device is described in this paper. First a measurement methodology was designed and measurements of air humidity, temperature and mass flow rates were performed. The measurement procedure concerned dedicated a steam generator and combi-steamer. Next a mathematical model was developed. It was based on mass and energy balances of the condensation hood. The condensate flow rate turned out to be insufficient to fulfill the energy balance while measured directly. Hence, it was calculated from heater’s power of the steam generator and the balance model was validated. The combisteamer had an unknown output, so the condensate flow rate was provided by the balance model after its validation. A preliminary diagnosis of the device was carried out as well.
Źródło:
Archives of Thermodynamics; 2020, 41, 1; 125-149
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical analysis of the steam flow field in shell and tube heat exchanger
Autorzy:
Bartoszewicz, J.
Bogusławski, L.
Powiązania:
https://bibliotekanauki.pl/articles/240429.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat transfer
heat exchanger
shell and tube heat exchanger
przenikanie ciepła
wymiennik ciepła
wymiennik płaszczowo-rurowy
Opis:
In the paper, the results of numerical simulations of the steam flow in a shell and tube heat exchanger are presented. The efficiency of different models of turbulence was tested. In numerical calculations the following turbulence models were used: k-ε, RNG k-ε, Wilcox k-ω, Chen-Kim k-ε, and Lam-Bremhorst k-ε. Numerical analysis of the steam flow was carried out assuming that the flow at the inlet section of the heat exchanger were divided into three parts. The angle of steam flow at inlet section was determined individually in order to obtain the best configuration of entry vanes and hence improve the heat exchanger construction. Results of numerical studies were verified experimentally for a real heat exchanger. The modification of the inlet flow direction according to theoretical considerations causes the increase of thermal power of a heat exchanger of about 14%.
Źródło:
Archives of Thermodynamics; 2016, 37, 2; 107-120
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimizing of Metal Foam Design for the Use as a Heat Exchanger
Autorzy:
Radkovský, F.
Gebauer, M.
Merta, V.
Powiązania:
https://bibliotekanauki.pl/articles/947585.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
metal foam
3D modeling
heat exchanger
heat conduction
efficiency
Opis:
The work deals with possibilities of using this specific material. It is focused on cast metal foams with a regular arrangement of internal cells and it refers to already used casting technologies – the production of metal foams with the aid of sand cores. Metal foams are used in many industries, such as: automotive, aerospace, construction, power engineering. They have unique propertiesand due to lower weight with sufficient strength and greater contact surface can be used, for example, for the conduction of heat. This article deals with the use of the metal foam as a heat exchanger. The efficiency of the heat exchanger depends on its shape and size and therefore the study is focused first on the optimization of the shape before the proper manufacture.
Źródło:
Archives of Metallurgy and Materials; 2018, 63, 4; 1875-1881
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/793577.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
heat pump
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
coefficient performance
statistical analysis
variance analysis
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 1
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods of Thermal Calculations for a Condensing Waste-Heat Exchanger
Autorzy:
Rączka, P.
Wójs, K.
Powiązania:
https://bibliotekanauki.pl/articles/185363.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odzysk ciepła kondensacji
obliczanie transferu ciepła i masy
wymiennik ciepła
ciepło odpadowe
condensation heat recovery
calculation of heat and mass transfer
heat exchanger
waste heat
Opis:
The paper presents the algorithms for a flue gas/water waste-heat exchanger with and without condensation of water vapour contained in flue gas with experimental validation of theoretical results. The algorithms were used for calculations of the area of a heat exchanger using waste heat from a pulverised brown coal fired steam boiler operating in a power unit with a capacity of 900 MWe. In calculation of the condensing part, the calculation results obtained with two algorithms were compared (Colburn-Hobler and VDI algorithms). The VDI algorithm allowed to take into account the condensation of water vapour for flue gas temperatures above the temperature of the water dew point. Thanks to this, it was possible to calculate more accurately the required heat transfer area, which resulted in its reduction by 19 %. In addition, the influence of the mass transfer on the heat transfer area was taken into account, which contributed to a further reduction in the calculated size of the heat exchanger - in total by 28% as compared with the Colburn-Hobler algorithm. The presented VDI algorithm was used to design a 312 kW pilot-scale condensing heat exchanger installed in PGE Belchatow power plant. Obtained experimental results are in a good agreement with calculated values.
Źródło:
Chemical and Process Engineering; 2014, 35, 4; 447-461
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy efficiency of ground heat exchangers co-operating with a compressor heat pump
Efektywnosc energetyczna wymiennikow gruntowych wspolpracujacych ze sprezarkowa pompa ciepla
Autorzy:
Kurpaska, S.
Latala, H.
Powiązania:
https://bibliotekanauki.pl/articles/792483.pdf
Data publikacji:
2012
Wydawca:
Komisja Motoryzacji i Energetyki Rolnictwa
Tematy:
compressor heat pump
heat exchanger
horizontal exchanger
vertical exchanger
ground heat exchanger
coefficient performance
statistical analysis
energy efficiency
Źródło:
Teka Komisji Motoryzacji i Energetyki Rolnictwa; 2012, 12, 2
1641-7739
Pojawia się w:
Teka Komisji Motoryzacji i Energetyki Rolnictwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Identification of fouling deposited on the heat transfer surfaces of the steam power plants heat exchangers
Autorzy:
Hajduk, T.
Powiązania:
https://bibliotekanauki.pl/articles/241825.pdf
Data publikacji:
2016
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
steam power plant
heat exchanger
heat transfer surface deposit
spectral analysis
Opis:
The term “fouling” refers to a substance, which settles on the heat transfer surface and causes the rise of thermal resistance to the heat transfer process. Sometimes, fouling is regarded as deposit but that term should be only used to fouling in the form of solid. Taking the traditional division of matter states as a criterion for fouling classification, there are three sorts of fouling: the solid ones, e.g. boiler scale, metal oxides, mud; the liquid ones, e.g. lubricating turbine oil and the volatile ones, air as for example an inert gas. Despite maintaining the recommended methods of correction for the steam power plants working agents, such as: the feed water, the boiler water, the condensate and the water vapour, for example by using the phosphate-ammonia correction, both corrosion and deposition phenomena occur in the water and the steam sides of the heat exchanger. Recognition of the type and the amounts of deposits gathered on heat transfer surfaces of the steam power plants heat exchangers is used within the thermal-flow diagnostics and also supports the planning of overhaul and routine repair of these devices. The results of the author’s own experimental research based on the method of spectral analysis were presented in the paper. The study was carried out in order to identify the type of fouling settled on both the outer side (steam side) and the internal side (waterside) on the heat transfer surfaces.
Źródło:
Journal of KONES; 2016, 23, 4; 135-142
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie korelacji opisujących wymianę ciepła w obszarze uderzających mikrostrug do projektowania kompaktowych wymienników ciepła: cz. 1. Budowa modelowego wymiennika ciepła i jego charakterystyka
Applicability of correlations of heat transfer in arrays of microjets to design compact heat exchangers: part 1. Model heat exchanger design and its characteristics
Autorzy:
Muszyński, T.
Andrzejczyk, R.
Powiązania:
https://bibliotekanauki.pl/articles/151400.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikrostrugi
wymiennik ciepła
intensyfikacja wymiany ciepła
microjets
heat exchanger
heat transfer intensification
Opis:
W artykule przedstawiono konstrukcję prototypowego, modułowego mikrostrugowego wymiennika ciepła. Przeprowadzone badania cieplno przepływowe w układzie woda-woda, umożliwiają określenie efektywności wymiany ciepła, charakterystyk cieplno przepływowych, oraz wielkości współczynnika przejmowania ciepła. Eksperymenty w dalszej części publikacji posłużą do weryfikacji stosowalności istniejących korelacji opisujących wymianę ciepła w obszarze uderzającej mikrostrugi.
The article presents experimental studies on a compact heat exchanger with heat transfer intensification by means of impinging microjets. The pursuit to provide high performance of heat exchangers is a response to the demand both in economics and in the universal tendency to miniaturization of industrial equipment. This paper presents the design of a prototype, modular microjet heat exchanger. The modular design of the heat exchanger allows to change its geometrical dimensions, as well as changing the heat exchange membrane material. Schematics, view of test section and design of the heat exchanger are shown in Figures 1 to 4. The study of heat transfer in water-water flow, allows to determine the heat transfer efficiency, the characteristics of heat transfer, and the heat transfer coefficient values. Data were collected for the pressure drops in heat exchanger not exceeding 15 kPa, i.e. such as in conventional heat exchangers. Hydraulic characteristics of a model heat exchanger are shown in Figures 5 and 6. Additionally for the two experimental series, comparison of the performance of tested heat exchanger with standard pipe in the pipe heat exchanger has been made, as shown in Figure 9. Conducted experimental research, in the following part of publication will be used to verify the applicability of the existing correlations of heat transfer in microjet impingement area.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 11, 11; 1021-1024
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A PCM-water heat exchanger with polymeric hollow fibres for latent heat thermal energy storage: a parametric study of discharging stage
Autorzy:
Hejčĺk, J.
Charvát, P.
Klimeš, L.
Astrouski, I.
Powiązania:
https://bibliotekanauki.pl/articles/280172.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
polymeric hollow fibre
heat exchanger
latent heat thermal energy storage
phase change materials
Opis:
The paper presents a theoretical parametric study into latent heat thermal energy storage (LHTES) employing polymeric hollow fibres embedded in a phase change material (PCM). The polymeric hollow fibres of five inner diameters between 0.5 mm and 1.5 mm are considered in the study. The effectiveness-NTU method is employed to calculate the thermal performance of a theoretical LHTES unit of the shell-and-tube design. The results indicate that the hollow fibres embedded in a PCM can mitigate the drawback of low thermal conductivity of phase change materials. For the same packing fraction, the total heat transfer rates between the heat transfer fluid and the PCM increase with the decreasing diameter of the hollow fibres. This increase in the heat transfer rate and thus the efficiency of the heat exchange to some extent compensate for the energy consumption of the pump that also increases with the decreasing fibre diameter.
Źródło:
Journal of Theoretical and Applied Mechanics; 2016, 54, 4; 1285-1295
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Utilization of heat from sewage
Wykorzystanie ciepła z kanalizacji
Autorzy:
Perackova, J.
Podobekova, V.
Powiązania:
https://bibliotekanauki.pl/articles/2065164.pdf
Data publikacji:
2013
Wydawca:
Politechnika Częstochowska
Tematy:
heat exchanger
heat recovery
wastewater
sewage pipes
wymiennik ciepła
rekuperacja
woda odpadowa
kanalizacja
Opis:
The increase in fossil fuel prices and the negative environmental impacts of fossil fuel use force people to use renewable energy more widely. Recovery of waste heat also ranks among the renewable energy sources. It is proposed mainly in passive houses and energy-efficient buildings. Heat from wastewater can be optimally used for heating, cooling and hot water preparation in low-energy houses. Thermal energy can be extracted from the drain outside the housing and also in the building. For heating or cooling systems in buildings sources of wastewater with higher flow, for example the administrative buildings, the swimming pools or industrial production are suitable. For preheating domestic hot water locally regenerative systems inside buildings can be used.
Wzrost cen paliw kopalnych oraz negatywne oddziaływanie na środowisko związane z ich użytkowaniem skłania ludzi do szerszego stosowania źródeł odnawialnych. Odzysk ciepła odpadowego również zalicza się do odnawialnych źródeł energii. Rozwiązania takie proponuje się głównie w domach energooszczędnych i pasywnych. Ciepło odzyskane ze ścieków może być wykorzystywane do ogrzewania, przygotowania ciepłej wody czy chłodzenia. Ciepło ze ścieków można odzyskać w budynkach, ale też poza nimi. Do ogrzewania lub chłodzenia w budynkach bardziej odpowiednie są źródła ścieków o wyższym przepływie, np. z budynków administracyjnych, basenów czy przemysłowych. Do przygotowania ciepłej wody użytkowej mogą być użyte lokalne systemy odzysku wewnątrz budynków.
Źródło:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym; 2013, 2 (12); 79--86
2299-8535
2544-963X
Pojawia się w:
Budownictwo o Zoptymalizowanym Potencjale Energetycznym
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Stanowisko do analizy pracy pomp ciepła wykorzystywanych do ogrzewania tuneli foliowych
Setup for analysing operation of heat pumps used to heat plastic tunnels
Autorzy:
Kurpaska, S.
Sporysz, M.
Powiązania:
https://bibliotekanauki.pl/articles/291602.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
ogrzewanie
wymiennik ciepła
plastic tunnel
heat pomp
heating
heat exchanger
Opis:
W pracy przedstawiono wyposażenie stanowiska, które będzie służyło do przeanalizowania pracy pomp ciepła wykorzystywanych do ogrzewania tuneli foliowych. Obiekt ten jest zlokalizowany na terenie Wydziału Agroinżynierii Akademii Rolniczej w Krakowie. Obiekt wyposażony jest w zarówno w wymienniki poziome jak i pionowe (dolne źródło ciepła) oraz sprężarkową pompę ciepła.
The paper presents equipment of the stand, which will be used to analyse operation of heat pumps used to heat plastic tunnels. This facility is located at the Faculty of Agricultural Engineering, Agricultural University in Krakow. The system is equipped with horizontal and vertical exchangers (lower heat source), and compressor-type heat pump.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 9 (97), 9 (97); 119-125
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Application of water equivalents method to calculations of cross-finned aluminium heat exchangers
Zastosowanie metody równoważników wodnych do obliczeń poprzecznie użebrowanych aluminiowych wymienników ciepła
Autorzy:
Karczewski, K.
Powiązania:
https://bibliotekanauki.pl/articles/263809.pdf
Data publikacji:
2010
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
wymiennik ciepła
równoważnik wodny
liczba jednostek przenikania ciepła
zredukowany współczynnik przenikania ciepła
powierzchnia wymiany ciepła
heat exchanger
water equivalent
number of heat transfer units
reduction over-all heat-transfer coefficient
heat surface area
Opis:
On an experimental post were carried out hydraulic and heat research of exchanger elements made of aluminium alloy. The research and calculations make possible to identify the reduction over-all heat-transfer coefficient from oil to heating air. The results of research enable to determine by water equivalents method design and using parameters of heat exchanger.
Na stanowisku doświadczalnym wykonano badania hydrauliczne i cieplne elementów wymiennika ciepła ze stopu aluminiowego. Badania i obliczenia umożliwiły identyfikację zredukowanego współczynnika przenikania ciepła od oleju do nagrzewanego powietrza. Wyniki badań umożliwiły określenie według metody równoważników wodnych parametrów konstrukcyjnych i eksploatacyjnych wymiennika ciepła.
Źródło:
Metallurgy and Foundry Engineering; 2010, 36, 1; 37-46
1230-2325
2300-8377
Pojawia się w:
Metallurgy and Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie dynamiki wymiany ciepła przy zastosowaniu technik filmowych
Investigation of heat exchange dynamics using film techniques
Autorzy:
Piotrowska, E.
Chochowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/288087.pdf
Data publikacji:
2012
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
smugoskop
wymiana ciepła
wymiennik ciepła
techniki filmowe
streak camera
heat exchange
heat exchanger
film technique
Opis:
W celu modelowania sieci hybrydowego układu zasilanego źródłami energii odnawialnej tworzony jest schemat zastępczej sieci cieplnej, składającej się z elementów obwodu elektrycznego, odpowiadających - przy zastosowaniu analogii termoelektrycznej elementom rzeczywistym. Prowadzone są prace nad stworzeniem modelu wymiennika ciepła, których fragmentem są eksperymenty nad elementami modelującymi wymiennik ciepła: element aktywny nagrzewa element pasywny poprzez medium, jakim jest powietrze. W opisanym fragmencie prowadzonych prac zastosowano smugoskop do zbadania pól temperatury, tworzących się w otoczeniu badanych elementów i pomiędzy nimi. Zaobserwowano zjawisko wzajemnego przekazywania sobie energii między elementem aktywnym i pasywnym, a ponadto intensywny ruch konwekcyjny, a więc w efekcie pole temperatur wewnątrz nagrzewanej spirali i nad jej centrum.
In order to model hybrid network of the system supplied with renewable energy sources, a new scheme of a substitutive heating network, composed of electric circuit elements, similar at use to thermoelectric analogy, real elements, is formed. Works on creating a heat exchanger model are carried out. Experiments on elements which model a heat exchanger constitute a part of these works: an active element heats a passive element through a medium, that is air. In the described part of the works, a streak camera was used to investigate temperature fields which form around the researched elements and between them. Mutual transfer of energy between an active and a passive element as well as intense convective movement were reported. Therefore, as a consequence, a temperature field inside the heated spiral and over its centre was reported.
Źródło:
Inżynieria Rolnicza; 2012, R. 16, nr 4, t. 1, 4, t. 1; 331-337
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Recuperator with microjet technology as a proposal for heat recovery from low-temperature sources
Autorzy:
Wajs, J.
Mikielewicz, D.
Fornalik-Wajs, E.
Bajor, M.
Powiązania:
https://bibliotekanauki.pl/articles/240624.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heat exchanger
microjet technology
heat recovery
Wilson plot method
wymiennik ciepła
odzysk ciepła
metoda Wilsona
Opis:
A tendency to increase the importance of so-called dispersed generation, based on the local energy sources and the working systems utilizing both the fossil fuels and the renewable energy resources is observed nowadays. Generation of electricity on industrial or domestic scale together with production of heat can be obtained for example through employment of the ORC systems. It is mentioned in the EU directive 2012/27/EU for cogenerative production of heat and electricity. For such systems the crucial points are connected with the heat exchangers, which should be small in size but be able to transfer high heat fluxes. In presented paper the prototype microjet heat exchanger dedicated for heat recovery systems is introduced. Its novel construction is described together with the systematical experimental analysis of heat transfer and flow characteristics. Reported results showed high values of the overall heat transfer coefficient and slight increase in the pressure drop. The results of microjet heat exchanger were compared with the results of commercially available compact plate heat exchanger.
Źródło:
Archives of Thermodynamics; 2015, 36, 4; 49-64
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies