Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Noszczyk-Nowak, A." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Heart rate turbulence in healthy dogs and dogs with dilated cardiomyopathy
Autorzy:
Noszczyk-Nowak, A.
Powiązania:
https://bibliotekanauki.pl/articles/30412.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
heart rate turbulence
healthy animal
dog
animal disease
dilated cardiomyopathy
baroreceptor reflex
Opis:
Heart rate turbulence (HRT) is modulated by the baroreceptor reflex and it was suggested that it could be used as a measure of autonomic dysfunction. Impaired HRT is of a significant prognostic value in humans after myocardial infarction, suffering from dilated cardiomyopathy and patients with heart failure. So far no studies were performed assessing the importance of HRT in dogs. The aim of this study was to prospectively evaluate the HRT turbulence onset (TO) and the turbulence slope (TS) in healthy dogs and in dogs with DCM and to compare the HRT in dogs with DCM that died during the first 30 days of observation and dogs with DCM that survived the first 30 days after the HRT analysis. The current study was aimed at determining reference value of the TO and TS of HRT in healthy dogs (control group) and dogs with dilated cardiomyopathy (DCM group). The tests were carried out on 30 healthy dogs and 30 dogs with DCM composed of Boxers, Doberman pinschers and Great Danes, of different sexes and body weights from 22 to 72 kg, aged between 1.5 and 11.5 years, submitted to the 24-hour Holter monitoring. HRT parameters were calculated using an HolCard software algorithm. TO is a percentage difference between the heart rate immediately following ventricular premature complex (VPC) and the heart rate immediately preceding VPC. TS corresponds to the steepest slope of the linear regression line for each sequence of five consecutive normal intervals in the local tachogram. The average TO in healthy dogs was determined as -13.55 ± 11.12%, TS was 21.33 ± 9.66 ms/RR. TO in dogs with DCM was determined as - 2.61 ± 2.1% and TS was 6.15 ± 3.86 ms/RR. Parameters of HRT were statistically significantly decreased (p<0.01) in dogs with DCM. HRT TO and TS were statistically significantly decreased in dogs with DCM. Dogs with DCM that survived more than 30 days of observation had HRT statistically significantly decreased in comparison to dogs with DCM that died after the 30’th day of observation. Decreased HRT parameters in dogs with DCM suggest an autonomic neuropathy which principally consists of the withdrawal of the cardiac parasympathetic tone. The more the autonomic neuropathy is advanced the faster the death of the dog with DCM might occur, with no correlation with the level of the heart failure.
Źródło:
Polish Journal of Veterinary Sciences; 2012, 15, 3
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Short-term and long-term PQ, QT and R-R intervals variability at the resting condition and after exercise testing in healthy Anglo-Arabian horses
Autorzy:
Paslawska, U.
Zysko, D.
Noszczyk-Nowak, A.
Paslawski, R.
Powiązania:
https://bibliotekanauki.pl/articles/30632.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
electrocardiographic parameter
short-term observation
long-term observation
R-R interval variability
exercise testing
healthy animal
Anglo-Arabian horse
horse
heart
autonomic nervous system
Opis:
The duration of electrocardiographic (ECG) parameters: PQ, QT and R-R intervals change during long-term and short-term observation as the consequence of the fluctuations in autonomic nervous system activity among others dependent on the exercise and resting. There is no data of horse breed influence on these parameters. The aim of the study was to assess the duration and the variability of the PQ, QT and R-R intervals in the resting conditions and after exercise testing in Anglo-Arabian horses. Material and Methods: 27 healthy Anglo-Arabian horses aged 3.4 ± 1.0 years (15 male, 12 female) had ECG examination in the standing position using Einthoven system of leads. The longest and the shortest PQ, QT and R-R intervals were measured after night rest and after exercise testing and the means were calculated. Conclusions: 1) In Anglo-Arabian horses the difference between the longest and the shortest PQ interval at rest vs. after exercise is 0.06 ± 0.05 vs. 0.03 ± 0.02, QT interval is 0.04 ± 0.03 vs. 0.04 ± 0.04, R-R interval 0.19 ± 0.15 vs. 0.08 ± 0.11. 2) The PQ and R-R intervals reveal high short-term variability either at the resting conditions or after exercise testing. 3) After exercise testing PQ, QT and R-R intervals are shorter than at the resting conditions. The delta PQ and R-R are 2 times smaller in contrast to delta QT which is constant. 4) The PQ and R-R interval variability was greater at the baseline condition than after exercise testing. The QT variability was similar at baseline condition to that after exercise testing.
Źródło:
Polish Journal of Veterinary Sciences; 2012, 15, 1
1505-1773
Pojawia się w:
Polish Journal of Veterinary Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies