Tytuł:
The study of harmonic imaging by AFM
Badania harmonicznych w obrazowaniu AFM
Autorzy:
Babicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/156072.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
mikroskop sił atomowych
powierzchnia
harmoniczne
atomic force microscopy (AFM)
surface
harmonics
Opis:
Atomic Force Microscopy (AFM) is a powerful tool for the analysis of surface samples with accuracy of single atoms. The existing methods include surface roughness, porosity and hardness of the test portion of the sample. The article presents the preliminary studyof a new AFM method of surface analysis. The study indicates that there may be a correlation between intensity of a harmonic resonance frequency of the needle and the system response. The suggested correlation can characterize elasticity of the analyzed surface.
Mikroskop sił atomowych (ang. Atomic Force Microscope - AFM) został wynaleziony w 1986 roku [1] jako alternatywa dla skaningowego mikroskopu tunelowego (ang. Scanning Tunneling Microscope - STM), którego nie można użyć do badań nad materiałami nieprzewodzącymi. AFM umożliwia pomiary materiałów zanurzonych w cieczach, co pozwala badać żywe preparaty biologiczne w warunkach zbliżonych do ich naturalnego środowiska [2]. W artykule przedstawiono zasadę pracy mikroskopu (rys. 1) oddziaływującego siłami van der Waalsa (opisanymi funkcją Lennarda - Jonesa) między ostrzem skanującym a próbką (1) (rys. 2) [3]. Opisano trzy podstawowe tryby pracy mikroskopu: kontaktowy, przerywany [4-6] oraz bezkontaktowy (2). Opierając się na dotychczasowych badaniach [7] wyznaczających różne właściwości materiału w zależności od ich budowy (rys. 3, rys. 4) przebadano próbkę warystora (rys. 5) pod kątem obecności i poziomu kolejnych harmonicznych pobudzającej częstotliwości rezonansowej w odpowiedzi układu. Przeprowadzone pomiary wskazują, że może istnieć związek między intensywnością kolejnych harmonicznych, a właściwościami badanej powierzchni.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 12, 12; 1508-1510
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Atomic force microscope data post-processing algorithm for higher harmonics imaging
Algorytm przetwarzania danych rejestrowanych za pomoca mikroskopu sił atomowych
Autorzy:
Babicz, S.
Powiązania:
https://bibliotekanauki.pl/articles/269108.pdf
Data publikacji:
2013
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
atomic force microscope
harmonics
imaging
algorithm
mikroskop sił atomowych
harmoniczne
obrazowanie
algorytm
Opis:
Previous works have proved that higher harmonics topography imaging using atomic force microscope (AFM) can significantly enhanced its measurement capabilities. Integrated tools dedicated to most of microscopes allow to visualize the investigated surface only by one selected harmonic. Because of the different characteristics of a sample, scanning tip and the environment, appropriate harmonic selection is time consuming and requires multiple scanning. In addition, repeated scanning guarantees no precise location of topographic formations, because the sample may be displaced. The author developed a system that allows simultaneous recording of the excitation signal, tips response signal from the photodiode and synchronization signal during typical surface scanning. The author presents an algorithm that allows higher harmonics surface imaging using these stored data.
Dotychczasowe badania wykazuja, że obrazowanie topografii za pomoca mikroskopu sił atomowych (AFM, ang. Atomic Force Microscope) z wykorzystaniem wyższych harmonicznych moe znaczaco rozszerzyc jego możliwosci pomiarowe. Z uwagi na różne własciwosci próbki, igły skanujacej i srodowiska, w jakim jest przeprowadzany pomiar, dobór odpowiedniej harmonicznej jest czasochłonny i wymagałby wielokrotnego skanowania powierzchni. Autor opracował system umożliwiajacy jednoczesna rejestracje sygnału pobudzajacego wibrujaca igłe skanujaca, sygnału odpowiedzi igły z fotodiody oraz sygnału synchronizujacego. Na podstawie tego ostatniego, możliwe jest precyzyjne okreslenie momentu badania danego obszaru próbki. Wykorzystujac przedstawiony algorytm przetwarzania zarejestrowanych danych, autor obrazuje jednoczesnie powierzchnie badanej próbki za pomoca wyższych harmonicznych oraz za pomoca dedykowanego oprogramowania AFM.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2013, 34; 9-12
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies