Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Ahmed, S." wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Passive filter design for three-phase inverter interfacing in distributed generation
Autorzy:
Ahmed, K. H.
Finney, S. J.
Williams, B. W.
Powiązania:
https://bibliotekanauki.pl/articles/262578.pdf
Data publikacji:
2007
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
DG
inverter
grid connected
filtering
damping
harmonics
Opis:
With the growing use of inverters in distributed generation, the problem of injected harmonics becomes critical. These harmonics require the connection of low pass filters between the inverter and the network. This paper presents a design method for the output LC filter in grid coupled applications in distributed generation systems. The design is according to the harmonics standards that determine the level of current harmonics injected into the grid network. Analytical expressions for the maximum inductor ripple current are derived. The filter capacitor design depends on the allowable level of switching components injected into the grid. Different passive filter damping techniques to suppress resonance affects are investigated and evaluated. Simulated results are included to verify the derived expressions.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2007, 13, 2; 49-58
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Magnetic field evaluation around 400 KV underground power cable under harmonics effects
Autorzy:
Boudjella, Houari
Ayad, Ahmed N. E. I.
Rouibah, Tahar
Larouci, Benyekhlef
Alghamdi, Thamer A. H.
Althobaiti, Ahmed
Ghoneim, Sherif S. M.
Tayeb, Abdelkader Si
Powiązania:
https://bibliotekanauki.pl/articles/2096182.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
electric power cables
magnetic field
harmonics
shielding
400 kV underground power system
kabel energetyczny
pole magnetyczne
harmoniczne
Opis:
Power lines or underground power cables generate electromagnetic interaction with other objects near to them. This study evaluates the magnetic field emitted by underground extra high voltage cables. The presented work aims to show a numerical simulation of the magnetic field of a buried 400 kV underground power line, which is used as a novel prototype in several countries at a short distance. The underground power cable study, in the presence of the current harmonics at different positions, with time variation by finite element resolution, using Comsol Multiphysics with Matlab software in two dimensions. The simulation results illustrate the magnetic flux density variation-in terms of amplitude and distribution as a function of different actual harmonics rates. The underground cable performance and magnetic field have affected by the harmonics effects. The maximum magnetic induction levels generated by significant harmonics are superior to the limits recommended by the international standard norms. In this paper, shielding has been used as an appropriate remedy to attenuate the magnetic field.
Źródło:
Diagnostyka; 2022, 23, 2; art. no. 2022209
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies