Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "groundwater treatment" wg kryterium: Temat


Tytuł:
Długopole – The history of a Spa
Historia Uzdrowiska w Długopolu
Autorzy:
RYBECZKA–GACEK, Anna
PIWKOWSKI, Jerzy
MUSZYŃSKA, Bożena
Powiązania:
https://bibliotekanauki.pl/articles/1033773.pdf
Data publikacji:
2014
Wydawca:
Zakład Opieki Zdrowotnej Ośrodek Umea Shinoda-Kuracejo
Tematy:
Długopole
balneology
groundwater
treatment
Opis:
Balneology (from Lat.: balneum - Steam, with gr,: lógos - science) the field of medicine spa known since antiquity that studies the healing properties of groundwater and mud, and using them in therapy. Balneology is especially effective treatment of chronic diseases such as rheumatoid arthritis, osteoarthritis and spine, post-traumatic and post-operative orthopedic osteoarthritis, gout, osteoporosis, coronary heart disease, post myocardial infarction, post alular and vascular diseases, hypertension, diseases of the nervous system and respiratory system. One of the most beautifully situated and rich in water treatment is a spa town in Dlugopole
Źródło:
Medicina Internacia Revuo; 2014, 26, 103; 126-132
0465-5435
Pojawia się w:
Medicina Internacia Revuo
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on the Influence of Temperature on the Activation of Selected Porous Mno2 Beds
Autorzy:
Skoczko, I.
Kisło, A.
Powiązania:
https://bibliotekanauki.pl/articles/124733.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
water treatment
iron
manganese
groundwater
Opis:
Rising demands concerning water treatment and conservation make it necessary to search for more effective as well as cheap and ecologically safe solutions. During the filtration process quartz sand is replaced by filter materials which also have a strong effect on account of reactions taking place on a bed’s surface. Today’s technologies for groundwater and seepage water treatment in rapid filters make use of oxidation beds. They are able to effectively remove manganese (II) and iron (II) compounds based on heterogeneous oxidation catalysis. The main catalyst of the manganese removal process in terms of its catalytic oxidation in filtration beds is manganese dioxide. This compound is used as an oxidizing agent in many processes. The research conducted as part of this paper was aimed at creating a product with the qualities similar to a popular Greensand bed protected by patent. The authors tested washed quartz sand varying in granulation which was subject to activation in 10% KMnO4 solution. Grains of quartz sand after covering them with a permanent coat of manganese oxide developed the superficial oxidation layer. While performing the tests, a temperature of the process served as a variable. The beds produced as a result of the experiment enable the removal of iron and manganese from water without prior alkylation. Furthermore, they are an effective method of purifying water of organic pollutants and ammoniacal nitrogen. They function as oxidizing and filtering masses.
Źródło:
Journal of Ecological Engineering; 2016, 17, 4; 228-231
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Use of Biofiltration Process to Remove Organic Matter From Groundwater
Autorzy:
Papciak, D.
Kaleta, J.
Puszkarewicz, A.
Tchórzewska-Cieślak, B.
Powiązania:
https://bibliotekanauki.pl/articles/952351.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
groundwater
biofiltration process
total organic carbon (TOC)
water treatment
Opis:
The article describes the research on the removal of organic matter from natural underground water using biofiltration process. The study was carried out in semi-technical scale on a model filter composed of activated carbon WD-extra. The development of biological activity in a biosorption bed, as well as observations on the relationship between the processes of sorption and biodegradation was evaluated based on the Eberhardt, Madsen, Sontheimer (EMS) test. Leading operation control parameters of biologically active carbon filter BAF included: change of TOC content, dissolved oxygen and permanganate index. To evaluate the colonization of granular carbon determination of ATP value was used. The presence of the biofilm was found by observation using light and scanning microscopes. The organic compounds in the water taken were adsorbed 100% and 70% biodegradable. The combination of sorption process with biodegradation until depletion of activated carbon adsorption capacity allowed in the initial phase of coalbed work for the removal of organic matter in approx. 100%. Formation of biofilm at the right time allowed to extend the filtration cycle and helped lower the TOC by 70%, i.e. from 10 mg C/l to 3–4 mg C/l.
Źródło:
Journal of Ecological Engineering; 2016, 17, 3; 119-124
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu oddziaływania zanieczyszczeń bytowo-komunalnych ze źródeł rozproszonych na jakość wód podziemnych na przykładzie prac zespołu interwencyjnego państwowej służby hydrogeologicznej
Analysis of the influence of sewage from diffuse sources on the groundwater quality, exemplified by research results of the Polish Hydrogeological Survey intervention team
Autorzy:
Kuczyńska, A.
Janica, R.
Powiązania:
https://bibliotekanauki.pl/articles/2075632.pdf
Data publikacji:
2017
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wody podziemne
zanieczyszczenie wód podziemnych
przydomowe oczyszczalnie ścieków
groundwater
groundwater pollution
on-site wastewater treatment facilities
Opis:
On-site wastewater treatment plants are designed to provide individual treatment of household wastewater to standards similar to those provided by municipal waste water treatment plants. In areas lacking sewage systems, they are an ecological alternative to septic tanks, but their correct functioning is determined by several factors, in particular sufficient infiltration parameters of soils and appropriate distance to the groundwater table. Failure to meet the above requirements may lead to disturbances in their functioning resulting in overflowing and, ultimately, pollution of surrounding soil and aquatic environment. This article shows a case study of groundwater pollution from sewage in a commune where over 400 on-site sewage treatment facilities were installed, funded from the EU programmes. During research conducted by the intervention team of the Polish Hydrogeological Survey it was found that the area of investment is characterized by low filtration parameters, and depth to the water table in many cases is limited and does not provide adequate filtration. Impact of the investment on the groundwater quality was demonstrated by analytical studies investigating the presence of microbial agents and pharmaceuticals.
Źródło:
Przegląd Geologiczny; 2017, 65, 11/2; 1312--1318
0033-2151
Pojawia się w:
Przegląd Geologiczny
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie napowietrzania do poprawy skuteczności sedymentacji zawiesin powstających podczas oczyszczania wód podziemnych.
The use of the aeration process for upgrading the efficiency of suspended solids sedimentation during groundwater treatment.
Autorzy:
Łomotowski, J.
Wiercik, P.
Powiązania:
https://bibliotekanauki.pl/articles/236606.pdf
Data publikacji:
2009
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
wody podziemne
popłuczyny
napowietrzanie
sedymentacja
groundwater
backwash water
aeration
water treatment
Opis:
W pracy podjęto próbę wykorzystania procesu napowietrzania sprężonym powietrzem do poprawy skuteczności sedymentacji zawiesin powstających podczas oczyszczania wód podziemnych. Przeprowadzone doświadczenia wykazały, że napowietrzanie popłuczyn odprowadzanych z filtrów do odżelaziania i odmanganiania wody podziemnej przyspiesza wytrącanie związków żelaza i manganu oraz zwiększa szybkość i skuteczność klarowania wody w odstojnikach. W dużych i średnich zakładach oczyszczania wód podziemnych możliwe będzie zastosowanie napowietrzania do podczyszczania popłuczyn, a po usunięciu osadu można rozważyć zawrócenie sklarowanej wody nadosadowej przed układ oczyszczania. Stosując okresowe napowietrzanie popłuczyn przed sedymentacją możliwe jest znaczne skrócenie czasu ich przetrzymania w odstojnikach, a tym samym zmniejszenie wielkości tych urządzeń.
The aeration process involved compressed air and was aimed at improving the sedimentation of the suspended solids that form in the course of groundwater treatment. The experiments have revealed that the aeration of the backwash water from the filters used for iron and manganese removal from the groundwater being treated not only accelerated the precipitation of iron and manganese compounds but also increased the rate and efficiency of water clarification in the settling tanks. The use of compressed-air aeration seems to be recommendable in large and medium-sized groundwater treatment plants where the process can be applied to the pretreatment of backwash water. It also seems worthwhile to consider the possibility of recirculating (upon sludge removal) the clarified supernatant into the treatment train. Periodic aeration conducted prior to the sedimentation process will shorten the time of backwash water retention in the settling tanks and thus permit their dimensions to be reduced.
Źródło:
Ochrona Środowiska; 2009, 31, 4; 21-24
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Koncepcja modernizacji systemu zaopatrzenia Zielonej Góry w wodę
Water supply system in Zielona Gora (Poland) reconstruction concept
Autorzy:
Jachimko, B.
Powiązania:
https://bibliotekanauki.pl/articles/237834.pdf
Data publikacji:
2013
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
ujęcie wody
woda podziemna
oczyszczanie wody
water intake
groundwater
water treatment
Opis:
Głównym niedomaganiem obecnego systemu zaopatrzenia Zielonej Góry w wodę jest mały stopień wykorzystania zasobów wód podziemnych, a także niewłaściwy rozdział poszczególnych rodzajów wody między odbiorców indywidualnych i przemysł oraz kosztowny system wielostopniowego tłoczenia wody. Opracowany model docelowy zaopatrzenia Zielonej Góry w wodę zakłada budowę dwóch nowych ujęć i stacji oczyszczania wody w południowej części miasta oraz rozszerzenie zasięgu obszaru objętego dostawą wód podziemnych. Z przeprowadzonej analizy wynika, że nie jest możliwe wyeliminowanie udziału wody powierzchniowej z zielonogórskiego systemu zasilania. Proponowany model pozwala jednak na zwiększenie udziału wód podziemnych wykorzystywanych do zaopatrzenia ludności. Na podstawie przeprowadzonej analizy sporządzono następujące wytyczne przebudowy obiektów istniejących: ujęcie wód powierzchniowych zostanie utrzymane (prognozowana wydajność 400 m3/h), stacja oczyszczania wody w Zawadzie nadal będzie oczyszczać wody zmieszane (powierzchniowe i podziemne) w prognozowanej ilości 1000 m3/h, pompownia przy ul. Sulechowskiej powinna w przyszłości zapewnić wydajność 1000 m3/h.
The main disadvantages of current water supply system in Zielona Gora include low degree of groundwater exploitation, improper distribution of individual water types among individual consumers and costly multistage pumping system. The target model of Zielona Gora water supply assumes building of the two new intake sites and a treatment plant in the southern part of the town as well as extension of groundwater supplied area. The analysis completed leads to conclusion that eliminating surface water contribution to Zielona Gora water supply system is not feasible. However, the proposed model allows increasing the contribution of groundwater to the water supply system. The following guidelines regarding existing objects reconstruction were developed based on the performed analysis: surface water intake site shall remain (prognostic efficiency of 400 m3/h), water treatment plant in Zawada shall continue to treat mixed waters (surface and groundwater) according to prognosis of 1000 m3/h, and the pumping system at Sulechowska street should insure future efficiency of 1000 m3/h.
Źródło:
Ochrona Środowiska; 2013, 35, 4; 29-32
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie PIX 112 do usuwania jonów arsenu z wody podziemnej w procesie koagulacji powierzchniowej w złożu filtru piaskowo-piroluzytowego
Application of PIX 112 to arsenic removal from groundwater by surface coagulation in the quartz sand-pyrolusite filter media
Autorzy:
Bray, R. T.
Fitobór, K.
Powiązania:
https://bibliotekanauki.pl/articles/237339.pdf
Data publikacji:
2016
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
oczyszczanie wody
woda podziemna
arsen
koagulacja
filtracja
water treatment
groundwater
arsenic
coagulation
filtration
Opis:
Przedstawiono wyniki badań technologicznych nad usuwaniem jonów arsenu z wody podziemnej z zastosowaniem procesu współstrącania związkami żelaza w układzie filtracji pospiesznej. Woda podziemna wykorzystana w badaniach zawierała około 40 mgAs/m3, 0,3 gFe/m3 oraz 0,09 gMn/m3. Technologia oczyszczania wody polegała na dawkowaniu koagulantu żelazowego do ujmowanej wody, jej napowietrzaniu (mieszaniu) oraz filtracji przez złoże z piasku kwarcowego i piroluzytu. Jako koagulant zastosowano PIX 112, będący wodnym roztworem siarczanu żelaza(III). Badania przeprowadzone w skali pilotowej wykazały, że koagulacja powierzchniowa jonami żelaza(III) pozwoliła na skuteczne usunięcie jonów arsenu do ilości dopuszczalnej w wodzie przeznaczonej do spożycia (<10 mgAs/m3) już przy niewielkich dawkach koagulantu wynoszących około 2,0 gFe/m3. Łącznie z arsenem usuwane były z wody również związki żelaza, zarówno naturalnie występujące w oczyszczanej wodzie, jak i dawkowane do niej w postaci koagulantu. Zastosowanie w złożu filtracyjnym warstwy piroluzytu pozwoliło ponadto na skuteczne usuniecie z wody także związków manganu. Eksploatacyjne układu technicznego w pełni potwierdziła wyniki uzyskane w badaniach pilotowych. W szczególności uzyskano jeszcze większą skuteczność usuwania jonów arsenu (do <6,0 mgAs/m3), przy mniejszych dawkach koagulantu niż w badaniach pilotowych.
Results of technological studies on arsenic removal from natural groundwater using iron co-precipitation in a rapid filtration system were presented. The groundwater used in the research contained approximately 40 mgAs/m3, 0.3 gFe/m3 and 0.09 gMn/m3. Purification system relied on the iron coagulant dosing, water aeration/mixing and filtration through the quartz sand and pyrolusite bed. Solution of iron(III) sulfate, i.e. PIX 112 was applied as a coagulation agent. Pilot scale research demonstrated that surface coagulation with iron(III) ions enabled effective arsenic removal to the level complying with the quality standards for water intended for human consumption (<10 mgAs/m3) even with relatively small coagulant doses of approximately 2.0 gFe/m3. Alongside arsenic, iron compounds were removed, both those naturally occurring in the treated water and those dosed as a coagulant. Moreover, the pyrolusite layer in the filter bed enabled effective manganese removal from water. Full technical scale experiments clearly confirmed the results obtained during the pilot phase. In particular, even higher effectiveness of arsenic removal of up to less than 6.0 mgAs/m3 was obtained with lower coagulant doses than those applied in the pilot studies.
Źródło:
Ochrona Środowiska; 2016, 38, 2; 45-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Water quality assessment after modernization of the technological system in the water treatment plant in Drzenin (Poland)
Autorzy:
Jakubaszek, Anita
Wilczyński, Jarosław
Powiązania:
https://bibliotekanauki.pl/articles/396749.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
groundwater
groundwater treated water
water quality
modernization
water treatment stations
wody gruntowe
uzdatnione wody gruntowe
jakość wody
modernizacja
stacje uzdatniania wody
Opis:
The article assesses the physical and chemical parameters of drinking water before and after the modernization of the technological system of water treatment station in Drzenin, Poland. The extension and modernization of the existing installation was necessary due to the poor technical condition of the devices, increasing demand for water in recent years and the periodic exceeding of the permissible values of water quality indicators. Analysis of physical and chemical properties of drinking water after the modernization of the system showed the effectiveness of the water purification processes used and the correct selection of the technological line. The obtained water quality parameters were in accordance with the Regulation of the Minister of Health on the quality of water intended for human consumption (Journal of Laws of 2017, item 2294).
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 4; 257-266
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of oxidation of manganese by potassium permanganate and chloride in the Velekinca water treatment plant, Kosovo
Autorzy:
Beluli, Valdrin M.
Powiązania:
https://bibliotekanauki.pl/articles/1844416.pdf
Data publikacji:
2020
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
chemical reactions
chlorine Cl2(g)
groundwater
manganese
oxidation
speed reaction
water treatment plant
Opis:
Our scientific research is based on oxidation reactions and monitoring of chemical reaction kinetics in the Velekinca groundwaters plant in Gjilan municipality, Kosovo. The GW of this plant contains high concentration of manganese so we need to use potassium permanganate (KMnO4) as one of the most power oxidants in the water treatment plant. In our research the high concentration of Mn in groundwaters is 0.22–0.28 mg∙dm–3 and this concentration is not in accordance with the WHO. Chlorine is one of the most common disinfectants used in the water treatment industry because it has a low cost and immediate effect on the destruction of microorganisms, the concentration of chlorine (Cl2) in our research is 0.1–0.32 mg∙dm–3. The speed of chemical reactions in the technology of GW is extremely important because sometimes in the elimination of chemical pollutants using oxidizing agents often form intermediate species. The speed of reactions indicates how fast chemical bonds are formed in the creation of a product, and this depends on the rate of reaction (XA). The focus for the research is to study the potassium permanganate and chlorine gas reactions in water if it forms intermediate products (intermediate species) due to the high speed of reactions. Scientific research conclusion, intermediate species in the oxidation reactions of Mn and water disinfection with Cl2(g) it is impossible to cause a high rate of chemical reactions from the reaction rate (XA = 1%) to the reaction rate (XA = 99%). The maximum speed at the highest XA Cl2 is from 4.405∙10–11 to 8.87∙10–10 mol∙dm–3∙s–1, while at Mn is (2.030–4.034)∙10–7 mol∙dm–3∙s–1.
Źródło:
Journal of Water and Land Development; 2020, 47; 30-37
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The Influence of Household Wastewater Treatment Plants with Drainage System on the Quality of Groundwater in the Lublin Province, Poland
Autorzy:
Jóźwiakowski, Krzysztof
Marzec, Michał
Listosz, Agnieszka
Gizińska-Górna, Magdalena
Micek, Agnieszka
Pytka, Aneta
Pochwatka, Patrycja
Rybczyńska-Tkaczyk, Kamila
Powiązania:
https://bibliotekanauki.pl/articles/1839295.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
household wastewater treatment plants
drainage system
water quality
wells
groundwater
physical pollutants
chemical pollutants
microbiological pollutants
Opis:
The work presented the assessment of household wastewater treatment plants with drainage systems on the quality of groundwater in dug wells and deep water wells in the area of 3 selected communes (Drelów, Dębowa Kłoda and Urszulin), located in the Lublin province in south-eastern Poland. The investigations of the physicochemical composition of water from selected 28 dug wells and 2 deep water wells were conducted from June to July 2020, involving 9 measurement series. The microbiological studies consisted in 4 measurement series. The composition of the wastewater from primary settling tanks discharged to soil via drainage systems located in the vicinity of considered wells was also examined on a single occasion. The studies indicate that the water from wells are significantly polluted with ammonia, nitrites, as well as compounds of natural origin: iron and manganese. The presence of microbiological pollution of fecal origin was noted. The studies clearly indicate the possible pollution of the analyzed well waters with domestic sewage discharged to soil via drainage systems. Therefore, it necessary to take the actions aimed at improving the quality of groundwater in the Lublin province, including limitation of drainage systems, especially in the areas with unfavorable subsurface and hydrological conditions as well as low water supply coverage. The need to introduce changes in legal regulations and strategies for the development of technical infrastructure in counties, favoring the most efficient, as well as simple and inexpensive technologies, was indicated.
Źródło:
Journal of Ecological Engineering; 2021, 22, 3; 18-39
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficiency of heavy metals removal during roof runoff infiltration through vegetated soil
Autorzy:
Sakson, G.
Powiązania:
https://bibliotekanauki.pl/articles/208054.pdf
Data publikacji:
2017
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
water treatment
cooper
groundwater
heavy metals
infiltration
soil
uzdatnianie wody
miedź
wody gruntowe
metale ciężkie
infiltracja
gleba
Opis:
Stormwater discharged from urban areas can contain significant amounts of heavy metals, especially zinc and copper. Roof runoff is very often directed into the soil and may pose a risk for groundwater quality. Lysimeter research has shown that zinc and copper contained in stormwater may be effectively removed by passing through vegetated soil. The average removal efficiency was greater than 90% and did not depend on the metal concentration in the influent, and the concentrations in the effluent met the limits for drinking water. Infiltration may be a reliable treatment method for roof runoff and may make stormwater safe for groundwater recharge.
Źródło:
Environment Protection Engineering; 2017, 43, 3; 143-154
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of carbonate-silica rock (opoka) to remove iron, manganese and indicator bacteria from groundwater
Zastosowanie skały węglanowo-krzemionkowej (opoki) do usuwania żelaza, manganu i bakterii wskaźnikowych z wód podziemnych
Autorzy:
Marzec, M.
Pieńko, A.
Gizińska-Górna, M.
Pytka, A.
Jóźwiakowski, K.
Sosnowska, B.
Kamińska, A.
Listosz, A.
Powiązania:
https://bibliotekanauki.pl/articles/947336.pdf
Data publikacji:
2017
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
groundwater
iron removal
manganese removal
silica-carbonate rock
water treatment
opoka
usuwanie manganu
usuwanie żelaza
uzdatnianie
wody podziemne
Opis:
The study investigated the efficiency of removal of iron, manganese and indicator bacteria from potable groundwater by using carbonate-silica rock (opoka). The tests were performed in a laboratory in three filter columns supplied with water containing increased concentrations of iron and manganese. Two of the columns were filled with carbonate-silica rock with particle sizes of 2–5 mm; retention time for water in the columns was set at 1 h and 2 h. A third column was filled with 1–2 mm rock particles, with hydraulic retention time set at 1 h. High removal efficiencies were determined for iron, manganese and coliform bacteria and low removal efficiencies for psychro- and mesophilic bacteria. An increase in the alkalinity of the investigated water was also observed.
W pracy przeanalizowano skuteczność usuwania żelaza, manganu i bakterii wskaźnikowych z wody podziemnej przeznaczonej do picia. Stosowano w tym celu skałę węglanowo-krzemionkową (opokę). Badania wykonano w warunkach laboratoryjnych w trzech kolumnach filtracyjnych zasilanych wodą o zwiększonej zawartości żelaza i manganu. Dwie z kolumn wypełniono skałą węglanowo-krzemionkową (opoką) o granulacji 2–5 mm, czas retencji wody w kolumnach ustalono odpowiednio na 1 i 2 h. Trzecią kolumnę wypełniono skałą o granulacji 1–2 mm, przyjmując czas retencji wody 1 h. Stwierdzono dobre efekty usuwania żelaza i manganu i bakterii grupy coli z badanych wód, niewielką skuteczność usuwania bakterii psychro- i mezofilnych, a także zwiększenie zasadowości wody.
Źródło:
Journal of Water and Land Development; 2017, 34; 197-204
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zero-valent iron for removal of inorganic contaminants from low pH water
Autorzy:
Suponik, T.
Powiązania:
https://bibliotekanauki.pl/articles/206918.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
chemicals removal (water treatment)
alkalinity
aquifers
coal mines
groundwater
groundwater pollution
groundwater resources
impurities
redox reactions
water pollution control
uzdatnianie wody
zasadowość
warstwy wodonośne
kopalnie węgla
wody gruntowe
zanieczyszczenie wód gruntowych
zasoby wód podziemnych
zanieczyszczenia wody
żelazo
reakcje redoks
zanieczyszczenia nieorganiczne
Opis:
The coal mine waste dumps located in the southern provinces of Poland pollute groundwater with metals. As a result of batch experiments presented in the paper, it can be said that it is possible to remove chromium and copper from the groundwater (which is affected by acid mine drainage, thus characterized by low pH) with the use of zero-valent iron in permeable reactive barrier technology. The contaminants are removed from the aquifer by the flow of groundwater through a reactive barrier filled with a special reactive material. Rapid metal removal likely occurred due to the reduction and the precipitation/co-precipitation and/or due to the adsorption onto the iron metal surface or/and onto the iron corrosion products. In accordance with the research it has also been found that in more alkaline environment, the oxidation of Fe(0) proceeds slower. A rapid decrease of the redox potential as well as the increases of pH have also been observed in the batch tests when the dose of Fe(0) in solutions increased.
Źródło:
Environment Protection Engineering; 2015, 41, 1; 15-27
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the properties and particle size distribution of spent filter backwash water from groundwater treatment at various stages of filters washing
Badania właściwości i rozkładów wielkości cząstek zawiesin w popłuczynach w różnych czasach trwania cykli filtracji
Autorzy:
Wiercik, P.
Matras, K.
Burszta-Adamiak, E.
Kuśnierz, M.
Powiązania:
https://bibliotekanauki.pl/articles/296715.pdf
Data publikacji:
2016
Wydawca:
Politechnika Częstochowska. Wydawnictwo Politechniki Częstochowskiej
Tematy:
water treatment plant
spent filter backwash water
laser granulometer
laser diffraction
groundwater
stacja uzdatniania wody
popłuczyny
granulometr laserowy
dyfrakcja laserowa
wody podziemne
Opis:
In Poland, water supply for villages and small towns is provided mainly from groundwater resources. In spite of good physicochemical and bacteriological properties for groundwater, in most cases it is required to remove iron and manganese, which influences the applied treatment technologies. The processes of potable water treatment result in the emergence of certain by-products, i.e. technological wastewater (mainly spent filter backwash water) and sediments that contain the pollutants removed from water. The study presents the results of the Authors’ tests of particle size and quantity distribution in spent filter backwash water from the groundwater treatment plant in Kąty Wrocławskie. The paper also contains an analysis of the changeability of iron and manganese content and turbidity in different phases of filter backwashing (initial backwashing, air backwashing, second backwashing). The research consisted of four series of tests conducted during the period from July 2013 to May 2014. Spent filter backwash water samples were collected during backwashing of two filters. Test results have shown that the quality of spent filter backwash water changed on subsequent stages of backwashing. Suspension particles of a size ranging from 10÷20 μm accounted for the highest volume percentage share in the analysed samples of spent filter backwash water from both filters, while the quantitative distribution of particles of the given diameters was heterogeneous and it depended on the stage of filter backwashing.
W Polsce w celu zaopatrzenia w wodę wsi i małych miasteczek ujmowane są przede wszystkim zasoby wód podziemnych. Pomimo dobrych właściwości fizyczno-chemicznych i bakteriologicznych wykazywanych przez wody podziemne większość z nich wymaga odżelaziania i odmanganiania, co ma wpływ na technologie ich uzdatniania. Podczas procesów uzdatniania wody przeznaczonej do spożycia przez ludzi powstają produkty uboczne, tj. ścieki technologiczne (głównie popłuczyny) oraz osady, w których zawarte są zanieczyszczenia usuwane z wody. W pracy przedstawiono wyniki własnych badań rozkładów wielkości i ilości cząstek zawiesin w popłuczynach ze stacji uzdatniania wód podziemnych w Kątach Wrocławskich. W artykule przeanalizowano również zmienność zawartości żelaza, manganu oraz mętności w różnych fazach płukania filtrów (płukanie wstępne wodą, płukanie powietrzem, płukanie właściwe wodą). Badania obejmowały cztery serie badawcze w okresie od lipca 2013 roku do maja 2014 roku. Próbki popłuczyn były pobierane podczas płukania dwóch filtrów. Wyniki badań wykazały, że jakość popłuczyn ulegała zmianie w kolejnych etapach płukania. Największy udział procentowy cząstek w badanych próbkach popłuczyn z płukania obydwu filtrów w ujęciu objętościowym stanowiły cząstki zawiesin o wielkościach z zakresu 10÷20 μm. Natomiast rozkład ilościowy cząstek o danych średnicach był niejednorodny i zależał od etapu płukania filtrów.
Źródło:
Inżynieria i Ochrona Środowiska; 2016, 19, 1; 149-161
1505-3695
2391-7253
Pojawia się w:
Inżynieria i Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Removal of pesticides and inorganic pollutants by reverse osmosis
Autorzy:
Šír, M.
Podhola, M.
Patočka, T.
Honzajková, Z.
Kocurek, P.
Bystrianský, M.
Vurm, R.
Kubal, M.
Powiązania:
https://bibliotekanauki.pl/articles/207770.pdf
Data publikacji:
2015
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
groundwater
groundwater pollution
pesticides
reverse osmosis
water treatment
batch process
chlorinated pesticides
inorganic pollutants
polyamide membranes
wody gruntowe
zanieczyszczenie wód gruntowych
pestycydy
odwrócona osmoza
uzdatnianie wody
proces wsadowy
chlorowane pestycydy
zanieczyszczenia nieorganiczne
membrany poliamidowe
Opis:
Contamination of soil and groundwater with pesticides is mainly caused by old ecological burdens. This study focuses on the treatment of groundwater contaminated with chlorinated pesticides. The contaminants mainly include α-HCH, β-HCH, γ-HCH, HCB, DDE, DDD and DDT. Reverse osmosis technology using RO98pHt polyamide membranes was used to remove the pollutants under batch process conditions. The observed rate of removal ranged from 98.4% to 99.7%. Total dissolved content solids decreased from 1.35 g/dm3 to below 0.05 g/dm3.
Źródło:
Environment Protection Engineering; 2015, 41, 2; 159-166
0324-8828
Pojawia się w:
Environment Protection Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies