Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "frequency measurement" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
A New Approach to Measurement of Frequency Shifts Using the Principle of Rational Approximations
Autorzy:
Murrieta-Rico, F. N.
Petranovskii, V.
Sergiyenko, O. Y.
Hernandez-Balbuena, D.
Lindner, L.
Powiązania:
https://bibliotekanauki.pl/articles/220851.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency measurement
rational approximations
sensors
Opis:
When a frequency domain sensor is under the effect of an input stimulus, there is a frequency shift at its output. One of the most important advantages of such sensors is their converting a physical input parameter into time variations. In consequence, changes of an input stimulus can be quantified very precisely, provided that a proper frequency counter/meter is used. Unfortunately, it is well known in the time-frequency metrology that if a higher accuracy in measurements is needed, a longer time for measuring is required. The principle of rational approximations is a method to measure a signal frequency. One of its main properties is that the time required for measuring decreases when the order of an unknown frequency increases. In particular, this work shows a new measurement technique, which is devoted to measuring the frequency shifts that occur in frequency domain sensors. The presented research result is a modification of the principle of rational approximations. In this work a mathematical analysis is presented, and the theory of this new measurement method is analysed in detail. As a result, a new formalism for frequency measurement is proposed, which improves resolution and reduces the measurement time.
Źródło:
Metrology and Measurement Systems; 2017, 24, 1; 45-56
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect Analysis of Loudspeaker’s Placement Angle and Direction on Frequency Response and Sound Pressure Level in TV Applications
Autorzy:
Demirel, Ibrahim
Powiązania:
https://bibliotekanauki.pl/articles/1953509.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
acoustic transducers
frequency measurement
frequency response
loudspeakers
Opis:
In a television, obtaining a good acoustic response is a challenging issue because of slim mechanical structures. The area dedicated for speaker’s placement is limited and inadequate space inside the cabinet of a TV prevents possible solutions to increase the sound performance. In addition, frame of the TV’s is getting narrower as the customers searching for the highest screen to body ratio. These designing aspects restrain optimal speaker positioning to achieve good sound performance. In this paper, an analysis related to speaker’s placement and mounting angle is proposed. A rotation setup compatible with a TV was prepared to measure different facing position of the speaker. This paper proposes the analysis of speaker’s rotation and facing direction in a flat panel television and its effects on sound pressure level together with deviation of the acoustic response. Measurement results are analyzed with an audio analyzer together with a statistics tool to achieve precise results.
Źródło:
Archives of Acoustics; 2021, 46, 1; 79-85
0137-5075
Pojawia się w:
Archives of Acoustics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laser frequency counting and frequency modulation width measurement from a FFT signal
Autorzy:
Křen, P.
Powiązania:
https://bibliotekanauki.pl/articles/221880.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
laser
modulation width
frequency measurement
optical frequency synthesizer
Opis:
A new method of optical frequency beat counting based on fast Fourier transform (FFT) analysis is described. Signals with a worse signal-to-noise ratio can be counted correctly comparing to the conventional counting method of detecting each period separately. The systematic error of FFT counting below 10 Hz is demonstrated and can be decreased. Additionally the modulation width of a frequency-stabilized laser with high frequency modulation index can be simultaneously measured during a carrier frequency measurement against an optical frequency synthesizer or other laser.
Źródło:
Metrology and Measurement Systems; 2012, 19, 3; 565-572
0860-8229
Pojawia się w:
Metrology and Measurement Systems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Mikrokontrolerowe konwertery "częstotliwość – kod" o zwiększonej dokładności
Microcontroller based "frequency to code" converters with increased accuracy
Autorzy:
Jasik, J. R.
Gapiński, C.
Powiązania:
https://bibliotekanauki.pl/articles/156366.pdf
Data publikacji:
2013
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
pomiar częstotliwości
metoda synchroniczna
metoda wagowa
mikroprocesorowy pomiar częstotliwości
frequency measurement
synchronous method
weight method
microcontroller based frequency measurement method
Opis:
W artykule przedstawiono nowoczesne metody pomiaru częstotliwości zapewniające zminimalizowanie błędu kwantowania dzięki użyciu zaawansowanych metod pomiarowych, predestynowanych do realizacji komputerowych. Układ zrealizowano przy użyciu 32-bitowego mikrokontrolera STM32F103CBT6 oraz komputera osobistego. Zaprezentowano algorytmy sterujące napisane dla mikrokontrolera w języku C oraz aplikację sterującą w środowisku LabVIEW. Przedstawione wyniki eksperymentu zobrazowały przewagę omówionych nowoczesnych metod w porównaniu do metod klasycznych.
The paper presents modern frequency measurement methods ensuring minimization of the quantization error. The minimization is achieved by using advanced measurement methods predestined for computer realization. The synchronous (Fig. 2) and weight algorithm (Fig. 4) methods are described. The synchronous method decreases the quantization error which is the results of no synchronization between the start and stop gating time Tp and the first and last impulse formed from the measured frequency signal. For low frequency measurements there was used the weight algorithm. This method guarantees minimization of the quantization error thanks to ascribing the weight coefficients to partial results of the measured Txi periods that are located inside the multiple n periods of the measured signal. The paper presents practical realization of the measurement with the constructed measuring system. The system was made by using a 32-bit microcontroller STM32F103CBT6 with counters, DMA and interrupt modules. In the paper there are described the control algorithms in C language for the microcontroller program (Fig. 7) and virtual control panel created in LabVIEW (Fig. 8). The results obtained show the advantages of the discussed methods in comparison to the classical methods (Figs. 10, 11 ).
Źródło:
Pomiary Automatyka Kontrola; 2013, R. 59, nr 7, 7; 624-627
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Krajowe porównanie międzylaboratoryjne generatora z mikroprocesorowym symulatorem sygnału z silnika krokowego zegara elektronicznego
Autorzy:
Osmyk, R.
Szterk, P.
Czubla, A.
Powiązania:
https://bibliotekanauki.pl/articles/1425881.pdf
Data publikacji:
2013
Wydawca:
Główny Urząd Miar
Tematy:
porównania międzylaboratoryjne
pomiar czasu
pomiar częstotliwości
interlaboratory comparisons
time measurement
frequency measurement
Opis:
W artykule przedstawiono zagadnienia dotyczące organizowanych przez GUM krajowych porównań międzylaboratoryjnych w dziedzinie czasu i częstotliwości. Opisano zalety zastosowania jako obiektu porównań generatora z symulatorem sygnału z silnika krokowego zegara elektronicznego i zwrócono uwagę na charakterystykę pracy chronokomparatorów.
Źródło:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar; 2013, 2; 14-16
2300-8806
Pojawia się w:
Metrologia i Probiernictwo : biuletyn Głównego Urzędu Miar
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Symulacja przetwarzania w torze pomiarowym z częstotliwościowym nośnikiem informacji w LabVIEW
Slotted line with frequency carrier of information simulation in LabVIEW
Autorzy:
Warda, P.
Powiązania:
https://bibliotekanauki.pl/articles/157220.pdf
Data publikacji:
2014
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
symulacja
tor z częstotliwościowym nośnikiem informacji
pomiar częstotliwości
LabVIEW
simulation
slotted line with a frequency carrier of information
frequency measurement
Opis:
W artykule opisano sposób realizacji symulacji przetwarzania informacji w torze z częstotliwościowym nośnikiem informacji. Zaproponowano strukturę symulowanego toru. Przedstawiono sposób realizacji proponowanej struktury. Omówiono sposób konfiguracji opracowanego modelu symulacyjnego toru pomiarowego. Przedstawiono przykładowe efekty pracy przyrządu.
In order to both convert and send information about measurement quantities, the slotted line with a frequency data carrier is increasingly often used. Regarding to the fact, that testing new constructions is expensive, the better way is to evaluate new ideas using simulations. In order to test numerical conversion, it is possible to use basic programming languages and dedicated software platforms. LabVIEW software was chosen for simulation purposes of the slotted line with frequency data carrier of information, because it is dedicated to control, metrological research and industrial solutions. Only basic components of the LabVIEW were used to develop new virtual instruments (VI) – a simulator of all parts of the slotted line with a frequency data carrier of information. It consists of a “physical-quantity-to-frequency” converter (X/f), a “frequency-to-code” converter (f/N), an analysing module, a visualisation module and a data saving module (Fig.1). Such an approach gives a very elastic diagram, which can be useful for extension of the simulator functionality. The presented solution (Fig.6) is useful for fast and easy evaluation of new methods. The designed simulator can convert signals with the accuracy better than 0,002%. It is enough for preliminary tests before implementation new concepts in real models. The example of the obtained results for the sinusoidal testing signal with amplitude 4,75V, frequency 1Hz and constant component 5,25V is presented in Fig. 7.
Źródło:
Pomiary Automatyka Kontrola; 2014, R. 60, nr 8, 8; 603-606
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Characteristic pulse detection method for fuzzy area
Autorzy:
Geng, Xin
Du, Baoqiang
Powiązania:
https://bibliotekanauki.pl/articles/2173662.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
frequency measurement
group period
phase coincidence fuzzy area
measurement gate
pomiar częstotliwości
okres grupowy
obszar rozmyty koincydencji faz
bramka pomiarowa
Opis:
In order to achieve higher frequency measurement accuracy, this paper proposed a characteristic pulse detection method of fuzzy area based on the quantized phase processing method of different frequency groups. First, the fuzzy area of the group phase coincidence points continuously moved on the time axis after passing through delay elements. The moving distance, that is, the number of the delay elements was determined by the main clock cycle of the D flip-flop. After that, three groups of phase coincidence detection fuzzy areas in different positions were sent to the digital logic module to extract the edge pulses of the phase coincidence detection fuzzy area. The pulse width is determined by the difference between the clock cycles of the delay elements. The clock cycles of different delay units were adjusted to obtain nanosecond or even picosecond circuit detection resolution. Finally, the pulses generated at the edge of the phase coincidence fuzzy area are taken as the switching signal of the frequency signal counter, so the stability of the gate signal and the accuracy of the gate time measurement are improved. The experimental results show that frequency stability can reach the order of E–13/s. In addition, compared with the traditional measurement method, it is characterized by simple structure, low cost, low noises, and high measurement resolution.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 2; art. no. e140553
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda zmniejszenia wartości błędu uśredniania w systemie pomiarowym wykorzystującym przetwornik "napięcie-częstotliwość"
A method for decreasing the average error in a measurement system using a "voltage-to-frequency" converter
Autorzy:
Warda, P.
Powiązania:
https://bibliotekanauki.pl/articles/155829.pdf
Data publikacji:
2011
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przetwornik napięcie-częstotliwość
pomiar częstotliwości
tor z częstotliwościowym nośnikiem informacji
voltage-to-frequency converter
frequency measurement
slotted line with a frequency carrier of information
Opis:
Przetwarzanie zmiennego napięcia w przetworniku typu "napięcie-częstotliwość" powoduje wygenerowanie sygnału wyjściowego o zmiennej częstotliwości. Istotnym składnikiem wypadkowego błędu przetwarzania informacji o wejściowym, zmiennym napięciu jest błąd uśredniania, którego wartość rośnie wraz ze zmniejszaniem częstotliwości wyjściowej przetwornika. W pracy opisano metodę pozwalającą na zmniejszenie błędu uśredniania poprzez zadawanie dodatkowego napięcia korygującego.
The paper presents a new method decreasing the total error in a slotted line with a frequency carrier of information. A changeable voltage conversion in a "frequency-to-voltage" converter causes generation of a signal of changeable frequency. In the presented situation the essential component of the total conversion error is the average error. When the frequency of a "voltage-to-frequency" converter output signal is decreased, the average error rises. The paper describes the method which allows decreasing the average error by setting the additional correcting voltage. Recent research on decreasing the conversion error in a slotted line are presented in the paper. Influence of the error components on conversion is also discussed (Fig. 1). There has been obtained the formula describing how a quotient of the constant component to the frequency signal amplitude influence the total error (1). A schematic diagram of a system for correction of the constant component is shown in Fig.3. There is also given the analysis of influence of the constant component on the total error (Fig. 5). The procedure for correction of the constant component is described and the procedure algorithm is given.
Źródło:
Pomiary Automatyka Kontrola; 2011, R. 57, nr 11, 11; 1297-1300
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Precyzyjny licznik czasu i częstotliwości z interfejsem PCI
Precise time and frequency counter with pci interface
Autorzy:
Kalisz, J.
Jachna, Z.
Szplet, R.
Różyc, K.
Powiązania:
https://bibliotekanauki.pl/articles/208422.pdf
Data publikacji:
2006
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
metrologia czasu
pomiar odcinka czasu
pomiar częstotliwości
rozdzielczość pikosekundowa
interpolator czasu
przetwornik czas-liczba
time metrology
time interval measurement
frequency measurement
picosecond resolution
time interpolator
time-to-digital converter
Opis:
Opisujemy budowę, działanie i wyniki pomiarów testowych precyzyjnego licznika czasu i częstotliwości, zrealizowanego w postaci karty komputerowej z interfejsem PCI. Pomiar odcinka czasu jest realizowany przy użyciu interpolacyjnej metody Nutta i specjalistycznego układu scalonego, wykonanego w technologii CMOS FPGA oraz zawierającego dwa interpolatory czasu. Licznik umożliwia pomiary odcinka czasu z rozdzielczością 200 ps i typowej niepewności pomiarowej ok. 150 ps, oraz pomiary częstotliwości metodą odwrotnościową do 3,5 GHz. Wbudowane są procedury specjalistyczne do kalibracji licznika, korekcji zegara, pomiaru różnicy częstotliwości i dewiacji Allana. Dzięki zastosowaniu szybkiej pamięci buforowej FIFO uzyskano dużą szybkość pomiarów, sięgającą 1.66⋅10⁶ pomiarów na sekundę przy transmisji danych do pamięci FIFO.
We describe the design, operation and test results of a precise time and frequency counter, built as a computer board with PCI interface. The time interval is measured with the use of the Nutt interpolation method implemented in a CMOS FPGA device containing two proprietary time interpolators. The time interval can be measured with a 200 ps resolution and the measurement uncertainty typically of about 150 ps. The frequency can be measured up to 3.5 GHz using the reciprocal method. Special routines have been built-in for counter calibration, clock correction, measurement of frequency difference, and Allan deviation. Thanks to the use of a fast FIFO memory, a high measurement rate has been achieved, reaching 1.66⋅10⁶ measurements per second when transferring data to FIFO memory.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2006, 55, sp.; 43-58
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies