Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "flow rate" wg kryterium: Temat


Tytuł:
Design and Modeling of an Experimental Hydraulic Device
Autorzy:
Tkáč, Z.
Halenár, M.
Kosiba, J.
Powiązania:
https://bibliotekanauki.pl/articles/2065018.pdf
Data publikacji:
2018
Wydawca:
STE GROUP
Tematy:
hydraulic fluid
flow rate
flow rate efficiency
Opis:
The design of the experimental laboratory device is based on the construction of the hydraulic circuits of mobile devices. It is possible to ensure the repeatability of the flow characteristic measurements at the laboratory. This means that in the operating test it is possible to verify the flow characteristics of the hydraulic pump and these results are not affected by the change in the physical properties of the applied liquid. By comparing of the flow characteristics directly on the work equipment (mini-excavator, etc.), the disadvantage is the need for dismantling the hydraulic pump and its mounting on the laboratory device. In some working device removal is not possible, where dismantling is structurally difficult or is time consuming, which increases the cost of their operation.The proposed experimental laboratory device serves to verify the flow characteristics of the hydraulic pump and is also designed to be universal, to test external gear hydraulic pump and hydraulic pump with inclined plate.
Źródło:
Multidisciplinary Aspects of Production Engineering; 2018, 1, 1; 63--68
2545-2827
Pojawia się w:
Multidisciplinary Aspects of Production Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The problem with flow in radial channels synchronous machine
Autorzy:
Makki, Z.
Janda, M.
Deeb, R.
Powiązania:
https://bibliotekanauki.pl/articles/377188.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
radial channels
synchronous machine
flow rate
Opis:
This paper describes the use of computational methods for solving the flow of the air-cooling in the large synchronous machines where it is used to cool the stator winding and stator radial channels which are located between the stator packet sheets. The overall process flow is mostly influenced by the size of air gap between stator and rotor, the shape of the radial channels, and by flow rates in machines. This paper mostly discusses about the influence flow rate of the cooling medium which has effects on the pressure distribution and flow rate in the radial channels. Cooling medium considered in this article an air and for and for calculation was chosen ANSYS CFX.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 72; 75-82
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Oxidation Behavior of Steel with Cr Content and Water Flow Rate
Autorzy:
Kim, D.-J.
Kim, K. M.
Shin, J. H.
Cheong, Y. M.
Lee, E. H.
Lee, G. G.
Kim, S. W.
Kim, H. P.
Choi, M. J.
Lim, Y. S.
Hwang, S. S.
Powiązania:
https://bibliotekanauki.pl/articles/351548.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
steel
flow accelerated corrosion
Cr content
flow rate
surface oxides
Opis:
Fast water flow facilitates ferrous ion transport leading to flow accelerated corrosion (FAC) of carbon steel and the possibility of a large accident through a failure of a secondary pipe in a nuclear power plant. Ion transport is directly linked to oxide properties such as the thickness, chemical composition and porosity. This work deals with a precise observation of the cross section of the corroded specimen focusing on an oxide passivity and its thickness using SEM (scanning electron microscope) and TEM (transmission electron microscope) as well as an apparent weight loss and a surface observation for the specimens corroded using a rotating cylindrical electrode autoclave system in pure water of pH 7 at 150°C having dissolved oxygen below 1 ppb within a flow rate range of 0 to 10 m/s. The Cr content in steel was changed from 0.02 to 2.4 wt%. Increasing the Cr content in the alloy, the FAC rate and oxide thickness decreased. The oxide porosity tends to decrease with the Cr content and immersion time owing to the development of Cr containing oxide. The oxidation behavior is not changed with the immersion time.
Źródło:
Archives of Metallurgy and Materials; 2017, 62, 2B; 1383-1387
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of flow rate through analysis of pipe vibration
Autorzy:
Venkata, S. K.
Navada, B. R.
Powiązania:
https://bibliotekanauki.pl/articles/386332.pdf
Data publikacji:
2018
Wydawca:
Politechnika Białostocka. Oficyna Wydawnicza Politechniki Białostockiej
Tematy:
accelerometer
estimation
frequency response
flow rate
neural network
vibration
Opis:
In this paper, implementation of soft sensing technique for measurement of fluid flow rate is reported. The objective of the paper is to design an estimator to physically measure the flow in pipe by analysing the vibration on the walls of the pipe. Commonly used head type flow meter causes obstruction to the flow and measurement would depend on the placement of these sensors. In the proposed technique vibration sensor is bonded on the pipe of liquid flow. It is observed that vibration in the pipe varies with the control action of stem. Single axis accelerometer is used to acquire vibration signal from pipe, signal is passed from the sensor to the system for processing. Basic techniques like filtering, amplification, and Fourier transform are used to process the signal. The obtained transform is trained using neural network algorithm to estimate the fluid flow rate. Artificial neural network is designed using back propagation with artificial bee colony algorithm. Designed estimator after being incorporated in practical setup is subjected to test and the result obtained shows successful estimation of flow rate with the root mean square percentage error of 0.667.
Źródło:
Acta Mechanica et Automatica; 2018, 12, 4; 294-300
1898-4088
2300-5319
Pojawia się w:
Acta Mechanica et Automatica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Single sensor based photovoltaic maximum power point tracking technique for solar water pumping system
Autorzy:
Daoud, A.
Midoun, A.
Powiązania:
https://bibliotekanauki.pl/articles/262763.pdf
Data publikacji:
2008
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
MPPT
boost converter
rmicrocontroller
DC motor-pump
flow rate
Opis:
The development of photovoltaic (PV) panels has made solar-powered pumps a reality. The pump drivers are usually direct-current (DC) motors which are fed by power electronic converters with maximum power point tracking (MPPT) to extract the whole energy that the PV panels can generate depending on the environmental conditions including irradiation and temperature. The implementation of MPPT algorithm essentially involves sensing both an input current and an input voltage. Understandably, such realization is expensive. In this paper, a solar PV water pumping system based on DC to DC converter as MPPT module is considered. The system consists of a PV array, a DC to DC boost converter and the DC motor coupled to a centrifugal pump. A proposed method is employed to seek the maximum power point using the flow rate obtained from a single sensor. A comparison with conventional hill climbing technique is included in experimental results to prove feasibility of the proposed method.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2008, 14, 2; 69-72
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Experimental Equipment for Investigation of Soybean Storage with Active Ventilation
Autorzy:
Duisenova, Sholpan
Atykhanov, Aibek
Karaivanov, Dimitar
Kassymbayev, Bekbossyn
Kalym, Kabdyrakhim
Sagyndikova, Aigul
Powiązania:
https://bibliotekanauki.pl/articles/125394.pdf
Data publikacji:
2020
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
active ventilation
air flow velocity
conveying height
flow rate
power consumption
productivity
Opis:
The article investigates and substantiates the operating modes of a container-modular equipment with active ventilation, such as specified (real) productivity, power consumption of the conveying process, as well as the use of a progressive method of controlling the humidity and temperature in soybean storage volume. Experimental equipment is developed which adequately simulates the proposed technology for soybean storage with active ventilation for the calculated data verification. The experiments confirm that the proposed experimental equipment makes it possible to adequately simulate the process of soybean storage with active ventilation and conduct experiments with the regulation of basic parameters such as productivity, power consumption, humidity, etc. using modern methods, devices and digital technologies. Experimental results are presented. Along with this, using the “Strazh Klimat” software, humidity and temperature are monitored during the experiments. Experimental data are obtained by the use of which it is possible to establish the dependence of the conveying height on the air flow velocity.
Źródło:
Journal of Ecological Engineering; 2020, 21, 3; 117-127
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The flow of rape seed in a silo equipped with a discharge device
Autorzy:
Kamiński, M.
Antonowicz, R.
Powiązania:
https://bibliotekanauki.pl/articles/1955775.pdf
Data publikacji:
2003
Wydawca:
Politechnika Gdańska
Tematy:
silo
anti-dynamic tube
flow rate
pressure distribution
damaged silo
Opis:
The paper contains a review of experiments with rape seed in a model silo with a semicircular flat bottom equipped with a low-height discharge device. Observations of flow patterns were made during filling and discharging through the transparent front wall of the model silo. Measurement of wall normal pressures and discharge flow rate were also made. A properly designed discharging device can eliminate a pressure peak which is usual for the transition point (dynamic overpressure) in mass flow silos. Experiments have shown that a low-height discharge device can be applied to reduce the pressure increase during discharging damaged silos.
Źródło:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk; 2003, 7, 4; 561-569
1428-6394
Pojawia się w:
TASK Quarterly. Scientific Bulletin of Academic Computer Centre in Gdansk
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The role of the gallery in the functioning of the foggara
Rola galerii w funkcjonowaniu foggary (podziemnej instalacji wodnej)
Autorzy:
Remini, B.
Powiązania:
https://bibliotekanauki.pl/articles/293100.pdf
Data publikacji:
2016
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
flow rate
foggara
gallery
Gourara
Touat
water
galeria
przepływ
woda
Opis:
In this article, we have highlighted the role of the gallery to improve the flow rate of foggara. The study based on observations and use of the latest inventory data (census 1998). The gallery of foggara can be divided into two parts: drainage and transport. The “drainage” part which is located inside the aquifer occupies 2/3 of the gallery of the foggara. The “transport” part of a length equal to 1/3 of the gallery of the foggara. Knowing the operating principle of the foggara, old methods of improving the flow of foggara were proposed. These included extension of the drainage part of the gallery, strengthening the base of the sealing of the transport part of the gallery, the realization of a small foggara and digging wells downstream of the main foggara.
W przedstawionej pracy objaśniamy rolę galerii w usprawnianiu przepływu wody w foggarze. Badania oparto na obserwacjach i ostatnim spisie z roku 1998. Galeria foggary składa się z dwóch części: odwadniającej i transportowej. Część odwadniająca jest zlokalizowana w poziomie wodonośnym i stanowi 2/3 galerii. Część transportowa ma długość 1/3 galerii. Znając zasady działania podziemnej instalacji wodnej zaproponowano dawne metody usprawnienia przepływu w podziemnym kanale. Obejmują one rozszerzenie drenującej części galerii, wzmocnienie i uszczelnienie transportowej części galerii, zbudowanie małego kanału i kopanie studni poniżej głównej instalacji.
Źródło:
Journal of Water and Land Development; 2016, 29; 49-57
1429-7426
2083-4535
Pojawia się w:
Journal of Water and Land Development
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zawodnienie szczelinowych skał krystalicznych w Sudetach
Water-bearing capacity of hard rocks in the Sudetes
Autorzy:
Staśko, S.
Powiązania:
https://bibliotekanauki.pl/articles/2063362.pdf
Data publikacji:
2002
Wydawca:
Państwowy Instytut Geologiczny – Państwowy Instytut Badawczy
Tematy:
wody podziemne
skały krystaliczne
zasoby
tempo wymiany
groundwater
hard rocks
water resources
flow rate
Opis:
W pracy przedstawiono nowe wyniki badań dotyczące występowania zwykłych wód podziemnych w środowisku szczelinowym skał krystalicznych Sudetów. Rozważania poprzedzono przeglądem dotychczasowych wyników badań i poglądów. Zaproponowano 3-strefowy model hydrauliczny gromadzenia i przepływu wód, wskazując na istotną rolę pokryw zwietrzelinowych. Model ten zmienia uproszczony, tłokowy schemat szybkiej wymiany wód podziemnych w tych obszarach. Pokrywy zwietrzelinowe powodują, że w modelu przepływu należy uwzględniać schemat mieszania się (przenikania się) wód wolno i szybko przepływających przez ośrodki o różnej pojemności i oporności hydraulicznej. Określono stopień zawodnienia skał krystalicznych w Sudetach, wskazując na wysoki odpływ podziemny i znaczną liczbę źródeł. Skały, z których wody eksploatowane są studniami wykazują średni i niski stopień zawodnienia, co pozwala uzyskać średnią wydajność 5 m3/h ze studni w strefach spękań. Ze względu na geometrię i właściwości hydrauliczne stref wodonośnych poziome ujęcia drenażowe dostarczają nawet do 100 m3/h wód w strefach regionalnych dyslokacji, np. Kletno-Stare Mesto. Propozycja wolnej wymiany wód została uzasadniona obserwacjami drenażu i poparta doniesieniami literaturowymi. Przemawiają za nią badania izotopowe, wskaźnikowe oraz składu chemicznego.
This paper presents new results on fresh groundwater occurrence in fractured crystalline rocks in the Sudetes. Description has been followed by review of previous results and approaches. Three-zones hydraulic model of water storage and flow has been proposed and indicate important role of the weathering cover. Recent study modificate simple piston flow scheme and rapid water exchange in such a region. Weathering zone existence showed that the flow model must be considered as mixing water with different rate of flow through media of different capacity and transmissivity. Water-bearing properties of hard rock in the Sudetes has been evaluated and indicated high groundwater run of fand spring's density. Crystalline formation tapped by water wells indicate low and intermediate yield and provide 5 m3/h of water in fissured zone. Due to geometry and hydraulic properties of water bearing zones horizontal water intake is able to provide up to 100 m3/h of water in regional fracture zones, e.g. Kletno—Stare Mesto in the Śnieżnik Massif. Proposed low groundwater flow has been supported by drainage observation data and also by some publication. Results of isotopic and traser studies as well as water chemical composition support proposed model.
Źródło:
Biuletyn Państwowego Instytutu Geologicznego; 2002, 404; 249--261
0867-6143
Pojawia się w:
Biuletyn Państwowego Instytutu Geologicznego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Metoda pomiaru strumienia objętości płynu w zastosowaniach do przepływomierzy kolanowych
The Indirect measurement method of flow rate in application to elbow meters
Autorzy:
Rup, K.
Malinowski, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/158123.pdf
Data publikacji:
2005
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
metoda pomiaru strumienia objętości płynu
zastosowanie
przepływomierze kolanowe
measurement method
flow rate
elbow meters
Opis:
W pracy zaproponowano metodę pośredniego pomiaru strumienia objętości płynu w zastosowaniu do przepływomierzy kolanowych. Idea metody polega na wyborze takiego rozwiązania numerycznego równań ruchu płynu wraz z równaniami modelu turbulencji, które spełnia z zadaną dokładnością warunek równości zmierzonej i obliczonej różnicy ciśnienia w skrajnych punktach siecznej przepływomierza kolanowego. W celu praktycznej realizacji metody zbudowano stanowisko doświadczalne. Obliczenia numeryczne wykonano za pomocą pakietu FLUENT. Otrzymane rezultaty pomiaru pośredniego porównano z odpowiednimi wynikami wyznaczonymi za pomocą kryzy.
In this paper the indirect measurement method of flow rate in application to elbow meters is proposed. The idea of the method is to choose the proper numerical solution of the flow and turbulence model equations, which will satisfy with required exactness the equality condition of measured and calculated values of pressure difference between edge points on the secant of elbow meter. With the aim of practical realisation of the method experimental facility was built. Numerical calculations were performed with application of FLUENT CFD software. Obtained results were compared to corresponding ones, measured with use of orifice meter.
Źródło:
Pomiary Automatyka Kontrola; 2005, R. 51, nr 5, 5; 35-37
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Określenie przepływów wody ogólnej na przyłączu wodociągowym w budynkach użyteczności publicznej
Determination of water flow connection in water supply system in public buildings
Autorzy:
Gwoździej-Mazur, J.
Tuz, P. K.
Powiązania:
https://bibliotekanauki.pl/articles/400513.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
przyłącze wodociągowe
przepływ obliczeniowy
wodomierz
natężenie przepływu
water supply system connection
design flow
water meter
flow rate
Opis:
Istotnym czynnikiem dla doboru wodomierzy głównych jest precyzyjne określenie przepływów obliczeniowych, wartości ich nieprzewyższenia. Obecnie normatywy techniczne, na podstawie których następuję określenie przepływów obliczeniowych dla doboru średnic przyłączy wodociągowych i w konsekwencji doboru wodomierzy, nie są miarodajne w stosunku do przepływów rzeczywistych, co daje podstawy do stwierdzenia, że normy zharmonizowane nie odpowiadają w założeniach warunkom polskim i wymagają korekty. W artykule zostaną zaprezentowanie metody określenia rzeczywistego przepływu obliczeniowego na przyłączu wodociągowym, który ma wpływ na poprawny dobór wodomierzy głównych w obiektach użyteczności publicznej.
An important factor for selection of main water meters is a precise determination of design flow, value of “nieprzewyższenia”. Presently, technical norms, on which determination of design flow for diameter selection of waterworks selection and consequently water meters selection are based, are no reliable in relation to the actual flow. This gives arguments to ascertain that harmonized standards do not meet Polish conditions and it requires correction. The article presents the method of determining the actual design flow for water supply system connection, which has an impact on a proper selection of main water meters in public buildings.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 74-77
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Outline of a model for flow of inhomogeneous working fluids via an interstice
Autorzy:
Ułanowicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/245561.pdf
Data publikacji:
2009
Wydawca:
Instytut Techniczny Wojsk Lotniczych
Tematy:
interstice
positive allowanc
manifold plunger (spool)
flow rate
volumetric content of contaminations
filtration
contamination concentration
Opis:
The paper presets flow characteristics of a hydraulic unit made up of a cylinder and a plunger, which is typical for most of precision pairs, as a function of contamination content in the working fluid. The consideration cover typical cases, including flow of contaminated fluid via an interstice (positive allowance), when the manifold plunger (spool) is in its initial position and the flow rate Qz of the working fluid at the manifold inlet is higher than the flow rate Q via the interstice, the manifold plunger (spool) is in its initial position and the flow rate Qz of the working fluid at the manifold inlet is lower than the flow rate Q via the interstice and when the manifold plunger moves against the manifold cylinder (body). Mathematical relationships, determined for all the above cases, define the following characteristics: volume of contaminants captured upstream the interstice, volume of contaminants captured in the interstice, volume of contaminants that flow out downstream the interstice, flow rate of the working flow downstream the interstice as a function of time, average velocity for the working fluid that flows out of the interstice as well as time interval that is necessary to fill in the interstice. Distribution of contaminants along the interstice length is described as well. The determined relationships served as a basis to find out interconnections between volumes of fluid that flows via an interstice and duration of the flow process.
Źródło:
Journal of KONES; 2009, 16, 3; 471-482
1231-4005
2354-0133
Pojawia się w:
Journal of KONES
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
CFD simulation and experimental study of ultrasonic flowmeters
Autorzy:
Roman, V.
Matiko, F.
Fedoryshyn, R.
Powiązania:
https://bibliotekanauki.pl/articles/115645.pdf
Data publikacji:
2017
Wydawca:
Fundacja na Rzecz Młodych Naukowców
Tematy:
ultrasonic flowmeter
mathematical model
flow rate
CFD
disturbed flow
error
przepływomierz ultradźwiękowy
model matematyczny
prędkość przepływu
zaburzenie przepływu
błąd
Opis:
This paper deals with CFD simulation and experimental study of ultrasonic flowmeters. A mathematical model of an ultrasonic flowmeter (USM) was built for studying the errors of flow measurement in disturbed flows. The method of defining the position coordinates of the acoustic paths and their weighting factors was improved based on the Gauss-Jacobi method of integration (i.e. the weighting function was improved) which provided the possibility to raise the accuracy of the turbulent flow velocity integration. The effectiveness of the improved method was verified using the Salami functions. New methodology for improving the mathematical model of USM is proposed. According to this methodology the dependence of the calibration factor on the Reynolds number is introduced into the model. A technique for studying the errors of USM in disturbed flows was developed on the basis of the proposed methodology. The developed technique was verified by comparing the CFD simulation results for a 3D model of an acting USM with the experimental results for this meter obtained by means of a reference test rig. The deviation of the simulation results from the obtained experimental data is not more than 1 %. Recommendations on defining the pipe straight lengths for the double-path chordal flowmeters were developed on the basis of the investigation results.
Źródło:
Challenges of Modern Technology; 2017, 8, 1; 37-43
2082-2863
2353-4419
Pojawia się w:
Challenges of Modern Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza przepływów wody w budynkach wielolokalowych przy wykorzystaniu wodomierzy statycznych
Analysis of water flows in multifamily buildings using static water meters
Autorzy:
Gwoździej-Mazur, J.
Powiązania:
https://bibliotekanauki.pl/articles/105377.pdf
Data publikacji:
2017
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
przyłącze wodociągowe
przepływ obliczeniowy
wodomierz
natężenie przepływu
wodomierz statyczny
water supply connection
calculation flow
water meter
flow rate
static water meter
Opis:
Wszelkie zmiany, wprowadzane w praktycznie każdej sferze związanej z działalnością człowieka, bardzo często wiążą się z różnego rodzaju problemami i pytaniami dotyczącymi tego zagadnienia. Okazuje się, że rozliczanie zużycia wody w budynkach wielolokalowych niesie za sobą szereg komplikacji, m.in. rozbieżność bilansu zużycia wody, a także problemy związane z niedoborami w kwestii rozliczania się z dostawcami wody przez zarządców nieruchomości. W artykule zostały zaprezentowanie wielkości przepływów rzeczywistych w ujęciu dobowym na przyłączu wodociągowym określone przy wykorzystaniu wodomierzy statycznych.
Any changes, introduced in practically every sphere of human activity, very often involves various problems and questions related to this issue. It turns out that accounting for water consumption in multifamily buildings carries a number of complications, such as divergence in water balance, also problems with deficiencies in the settlement of water suppliers by property managers. The article will show the actual flow rates in daily terms at the water connection determined using static water meters.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2017, 64, 4/II; 521-530
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelowanie miejskiego systemu zaopatrzenia w wodę na przykładzie osiedla mieszkaniowego Baranówka w Rzeszowie
Modeling of a municipal water distribution system: A case study
Autorzy:
Kotowski, A.
Pawlak, A.
Wójtowicz, P.
Powiązania:
https://bibliotekanauki.pl/articles/237295.pdf
Data publikacji:
2010
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
modelowanie
sieć wodociągowa
pobór wody
ciśnienie
przepływ
kalibracja
modeling
water-pipe network
water demand
pressure
flow rate
calibration
Opis:
Będący przedmiotem badań proces identyfikacji oporności hydraulicznej sieci wodociągowej osiedla Baranówka w Rzeszowie polegał na iteracyjnym dopasowywaniu hipotetycznych oporności każdego przewodu do wartości oporności rzeczywistych, w oparciu o dane wyjściowe dotyczące rodzaju materiału przewodów, czasu eksploatacji, jakości wody oraz wyników pomiarów oporności wybranych przewodów na sieci. Weryfikację zbudowanego modelu oraz adekwatności oporności przewodów przeprowadzono na podstawie kilku eksperymentów, polegających na jednoczesnym pomiarze ciśnienia i strumienia przepływu wody w wybranych punktach pomiarowych, przy zastosowaniu kontrolowanych upustów wody. Proces identyfikacji uznano za zakończony, gdy różnice ciśnień zmierzonych w sieci oraz zasymulowanych przy pomocy zbudowanego modelu nie przekraczały 2 mH2O. Uzyskane wyniki analiz porównawczych, które zostały przeprowadzone w zmiennych warunkach zasilania i poboru wody w sieci wodociągowej, potwierdzają adekwatność zbudowanego modelu hydraulicznego na poziomie założonej dokładności.
The case in point is the water distribution system in Baranowka, a housing estate of the city of Rzeszow. The object under study is the process of hydraulic resistance identification for this water distribution system. The paper includes a description of the identification process, which consisted in adjusting the hypothetic resistance of each pipe to its real resistance, making use of the following input data: pipe material and age, quality of transported water, and the measured values of hydraulic resistance for selected pipes. The constructed hydraulic model and the adequacy of the estimated pipe resistance were verified by a number of experiments, where pressure and flow rate were measured simultaneously at selected points of the water-pipe network during controlled fire hydrant outflows. The identification process was regarded as completed when the difference between the pressure measured in the water-pipe network and the pressure simulated using the hydraulic model did not exceed 2 mH2O. The results of comparative analysis performed under variable conditions of water demand and supply in the water-pipe network substantiate the adequacy of the hydraulic model at the level of the accuracy assumed.
Źródło:
Ochrona Środowiska; 2010, 32, 2; 43-48
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies