Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Półka, Marzena" wg kryterium: Autor


Wyświetlanie 1-2 z 2
Tytuł:
Analysis of Fire and Explosion Properties of LNG
Analiza właściwości pożarowych i wybuchowych LNG
Autorzy:
Półka, Marzena
Piec, Robert
Olcen, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2060731.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
LNG
fire safety
process safety
bezpieczeństwo pożarowe
bezpieczeństwo procesowe
Opis:
Aim: The aim of this article is to analyse fire and explosion properties of LNG along with the identification of hazards that may arise during emergency incidents involving it. The article is based on an analysis of the available literature and a full-scale experimental study involving a 200-liter LNG tank leading to a jet fire. Introduction: Safe use and proper transport of flammable and harmful substances, together with the analysis of the effects of threats, enable the reduction of the number of accidents and provide possible conditions for the evacuation of people and property in a hazard zone. The compilation and systematization of knowledge on the safe use of the environmentally friendly LNG fuel will allow for an increase in the scope of its use. It is consistent with the state’s sustainable development policy consisting in identifying threats or adjusting technical solutions that minimize losses in transport or industry. Methodology: There are many legal acts in the world regarding safe storage and transport of LNG. One of the most important is Directive 2012/18/EC known as “Seveso III”. This document contains requirements for the prevention of major accidents involving hazardous substances – including LNG – and ways to reduce their negative effects on human health and the environment. Relevant requirements have also been specified in standards, tests, articles and other international acts, including in the European agreement on the international carriage of dangerous goods by road (the so-called ADR Agreement). The article compares flammable and explosive parameters of LNG. Possible scenarios occurring during the release and ignition of the LNG vapour cloud have been shown. The change of pressure of LNG vapour in the 200 l tank as a function of its heating time in the burning spill of a mixture of gasoline and diesel fuel is presented. In such a thermal exposure, a jet fire with a flame length of up to 5 meters was obtained. Conclusions: The proper use of flammable gases should be a priority in ensuring fire and explosion safety in facilities, during transport, etc. Hence, recognizing the threats and comparing them, or matching technical solutions that minimize the effects of LNG failures will allow active inclusion of knowledge in this field in the process of protection against fire and explosion. In case of LNG storage, attention should be paid to the types of materials in the immediate vicinity of this liquefied gas in order to have sufficient mechanical properties at the lowest liquefied gas temperature.
Cel: Celem artykułu jest analiza właściwości pożarowych i wybuchowych LNG wraz z określeniem zagrożeń, które mogą pojawić się podczas zdarzeń awaryjnych z jego udziałem. Artykuł opiera się na analizie dostępnej literatury oraz badaniu eksperymentalnym w pełnej skali z udziałem zbiornika LNG o pojemności 200 litrów doprowadzającego do powstania pożaru strumieniowego (ang. jet fire) Wprowadzenie: Bezpieczne stosowanie oraz właściwy transport substancji palnych i szkodliwych wraz z analizą skutków zagrożeń umożliwiają zmniejszenie liczby awarii i dostarczają możliwe warunki do ewakuacji osób oraz mienia znajdujących się w strefie zagrożenia. Zestawienie i usystematyzowanie wiedzy dotyczącej bezpiecznego stosowania paliwa LNG przyjaznego dla środowiska pozwoli na zwiększenie zakresu jego wykorzystania. Jest to spójne z polityką zrównoważonego rozwoju państwa polegającą na identyfikacji zagrożeń czy dopasowaniu rozwiązań technicznych minimalizujących straty w transporcie lub przemyśle. Metodologia: Na świecie istnieje wiele aktów prawnych dotyczących bezpiecznego magazynowania, składowania oraz transportu LNG. Jednym z najważniejszych jest dyrektywa 2012/18/WE znana jako „Seveso III”. Dokument ten zawiera wymagania dotyczące zapobiegania poważnym awariom z udziałem substancji niebezpiecznych – w tym LNG – oraz sposoby zmniejszenia ich negatywnych skutków dla zdrowia ludzkiego i środowiska. Istotne wymagania zostały określone także w normach, badaniach, artykułach i innych aktach międzynarodowych, m.in. w umowie europejskiej dotyczącej międzynarodowego przewozu drogowego towarów niebezpiecznych (tzw. Umowa ADR). W artykule dokonano zestawienia parametrów palnych i wybuchowych LNG. Ukazano możliwe scenariusze zachodzące podczas uwolnienia i zapłonu chmury par LNG. Przestawiono zmianę ciśnienia par LNG w zbiorniku o pojemności 200 l w funkcji czasu jego ogrzewania w palącym się rozlewisku mieszaniny benzyny z olejem napędowym. W takiej ekspozycji cieplnej otrzymano pożar strumieniowy o długości płomienia maksymalnie 5 metrów. Wnioski: Właściwe stosowania gazów palnych powinno być priorytetem w zapewnieniu bezpieczeństwa pożarowego i wybuchowego w obiektach, transporcie itp. Stąd też poznanie zagrożeń i ich zestawienie, czy dopasowanie rozwiązań technicznych minimalizujących skutki awarii z LNG pozwoli na aktywne włączenie wiedzy z tego zakresu w proces zabezpieczenia przed pożarem i wybuchem. W przypadku magazynowania LNG należy zwrócić uwagę na rodzaje materiałów znajdujących się w bezpośrednim otoczeniu z tym gazem skroplonym, aby posiadały wystarczające właściwości mechaniczne w najniższej temperaturze skroplonego gazu.
Źródło:
Safety and Fire Technology; 2021, 58, 2; 58--73
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of Safety Requirements Regarding Trading and Storing of Pyrotechnical Articles in Poland
Przegląd wymagań dotyczących bezpieczeństwa obrotu i magazynowania wyrobów pirotechnicznych w Polsce
Autorzy:
Półka, Marzena
Bielesza, Dorota
Szajewska, Anna
Powiązania:
https://bibliotekanauki.pl/articles/2060779.pdf
Data publikacji:
2020
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire safety
explosion safety
pyrotechnics
explosives
materiały wybuchowe
bezpieczeństwo
pożar
wybuch
materiały pirotechniczne
Opis:
Purpose: The objective of the paper was to identify and analyse relevant requirements regarding the safety of storage and usage of pyrotechnic materials, intended for civil use. The review was based on binding applicable Polish and European legal acts. The results of the review pointed to the ambiguity of the provisions regulating the issues of safe usage and storage of pyrotechnical materials. Introduction: Some pyrotechnic articles, when triggered by a proper impulse, can lead to a violent reaction resulting in the release of a large amount of heat, and the creation of a blast wave. The effects of this reaction have a destructive impact on buildings situated nearby and pose a hazard to human life. Use and storage of pyrotechnic articles against the set rules is associated with the risk of fire or explosion, therefore a number of requirements have been introduced in this area. Methods: In Poland there are many legal acts applicable to explosives. One of the most important one is the Act of 21 June 2002 on explosives designated for civil use, which presents pyrotechnic materials with respect to the safety of their usage and storage. Several key requirements have also been specified in agreements ratified in Poland and in other international acts, such as for example: the European Agreement concerning the International Carriage of Dangerous Goods by Road(ADR), and the Directive of the European Parliament and of the Council 2013/29/EU of 12 June 2013 on the harmonisation of laws of the Member States relating to the making available on the market of pyrotechnic articles. Results: It was established that there is a need of adopting a legal solution for storing pyrotechnical products for temporary sales in containers located near commercial facilities (and serving as back-up facilities). Although the regulations are not clear-cut, such a solution is used in practice, thus it would be advisable to determine by means of legal acts whether it is permissible and what requirements should be fulfilled, for example by a container, in which pyrotechnic articles are temporarily stored. Conclusions: The specification presented in the article allows to see the need to minimize the hazards associated with the marketing of pyrotechnical materials and justifies the necessity of adopting a particularly diligent classification and use of nomenclature for these products. In case of storing pyrotechnical materials, it is erroneous to adopt the determination of class “G” for two variable of net mass values of the explosive (when determining safe distances for explosive storage facilities, including among others class 1, sub-classes 1.3, 1.4). The same applies to the hexogen equivalent of an explosive load (when determining safe distances for explosive storage facilities including class 1, sub-classes 1.1, 1.5 and 4.1). Such provisions are misleading and may cause erroneous interpretations of regulations.
Cel: Celem artykułu było zestawienie oraz przeanalizowanie wymagań dotyczących bezpieczeństwa magazynowania i użytkowania materiałów pirotechnicznych przeznaczonych do użytku cywilnego. Do przeglądu wykorzystano obowiązujące polskie i europejskie akty prawne. Na podstawie przeprowadzonej analizy wykazano niejednoznaczność zapisów regulujących kwestie bezpiecznego stosowania i magazynowania materiałów pirotechnicznych. Wprowadzenie: Niektóre materiały pirotechniczne pod wpływem odpowiedniego impulsu mogą doprowadzić do gwałtownej reakcji, skutkującej wydzieleniem dużej ilości ciepła oraz powstaniem fali podmuchu. Efekty takiej reakcji działają niszcząco na znajdujące się w pobliżu budynki oraz stanowią zagrożenie dla życia ludzkiego. Niezgodne z zasadami stosowanie oraz przechowywanie wyrobów pirotechnicznych wiąże się z ryzykiem pożaru lub wybuchu, dlatego też w obszarze tym wprowadzono szereg wymagań. Metody: W Polsce funkcjonuje wiele aktów prawnych dotyczących materiałów wybuchowych. Jednym z najważniejszych jest Ustawa z dnia 21 czerwca 2002 r. o materiałach wybuchowych przeznaczonych do użytku cywilnego. W dokumencie tym zostały przeanalizowane wymagania dla materiałów pirotechnicznych pod względem ich bezpieczeństwa użytkowania i magazynowania. Istotne wymagania zostały określone także w umowach ratyfikowanych przez Polskę i innych aktach międzynarodowych m.in.: umowie europejskiej dotyczącej międzynarodowego przewozu drogowego towarów niebezpiecznych (tzw. umowa ADR) oraz Dyrektywie Parlamentu Europejskiego i Rady 2013/29/UE z dnia 12 czerwca 2013 r. w sprawie harmonizacji ustawodawstw państw członkowskich odnoszących się do udostępniania na rynku wyrobów pirotechnicznych. Wyniki: Stwierdzono, że potrzebne jest prawne rozwiązanie kwestii przechowywania w kontenerach znajdujących się obok obiektów handlowych (i służących jako zaplecza) zapasu wyrobów pirotechnicznych przeznaczonych do celów tymczasowej sprzedaży. Pomimo że przepisy nie są jednoznaczne, taka metoda magazynowania jest stosowana w praktyce. W związku z tym wskazane jest, aby za pomocą aktów prawnych określić, czy jest ona dopuszczalna oraz jakie wymagania powinien spełniać np. kontener, w którym tymczasowo przechowuje się materiały pirotechniczne. Wnioski: Przedstawione w pracy zestawienie pozwala dostrzec potrzebę minimalizowania zagrożeń związanych z obrotem materiałów pirotechnicznych oraz konieczność szczególnie starannej klasyfikacji i stosowania nazewnictwa tych wyrobów. W przypadku magazynowania materiałów pirotechnicznych mylące jest oznaczenie klasy „G” dla dwóch zmiennych masy netto materiału wybuchowego (przy wyznaczaniu bezpiecznych odległości dla magazynów materiałów wybuchowych, m.in. klasy 1, podklasy 1.3, 1.4). To samo dotyczy równoważnika heksogenowego ładunku wybuchowego (przy wyznaczaniu bezpiecznych odległości dla magazynów materiałów wybuchowych klasy 1, podklasy 1.1, 1.5 i 4.1). Zapisy takie wprowadzają w błąd i mogą być przyczyną błędnej interpretacji przepisów.
Źródło:
Safety and Fire Technology; 2020, 56, 2; 76--90
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies