Tytuł:
The efekt fire fighting foams on the environment and fire extinguishing
Skuteczność pian gaśniczych oraz ich wpływ na środowisko
Autorzy:
Turekova, I.
Balog, K.
Półka, M.
Powiązania:
https://bibliotekanauki.pl/articles/373583.pdf
Data publikacji:
2012
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
biodegradowalność środków pianotwórczych
piany
środek gaśniczy
właściwości gaśnicze
biodegradability of foamers
extinguishing properties
fire
fire extinguisher
foams
Opis:
Extinguishing foams are commonly used for extinguishing the fire of flammable liquids, whereby their insulating, choking and quenching effects are exploited. The purpose of this paper is to consider and compare foams currently used in Slovak fire departments, with respect mainly to their high extinguishing effect (capability of faster aborted burning on a large surface at low foam consumption), but also their impact on the environment in each stage of their life cycle. Fire fighting foams are commonly used to reduce the spreading and extinguishing of Class B fires and to prevent re-ignition. These foams can be used to prevent ignition of flammable liquids and in certain conditions for extinguishing Class A fires. Foams can be used in combination with other extinctive substances, mainly gaseous and powders ones. Modern fire-fighting foams can be considered to be very good in terms of physical characteristics, but in recent years, the REACH legislation draws attention to their ecotoxicological properties. If fire-fighting foams are used to extinguish large fires, their products (such as decomposed water from the formed foam) are very likely to get into the soil and water flow, concurrently affecting the possibility of wastewater purification. All types of foam have different ecological characteristics since their components determine the rate of biodegradation. The ecotoxicological tests of Sinapis alba also showed that even a low concentration of foamer exhibits significant toxicity. Tis paper describe of analysis for four foam: Sthamex AFFF 1 %, Sthamex AFFF F-15, Pyronil, Moussol APS F-15. It is necessary to know their physical characteristics, e.g. their stability at low and high temperatures defined by half-life; the number of foaming specifying whether it is heavy, medium or light foam, and also their viscosity properties to be appropriately selected and used in fire-fighting practice.
Piany gaśnicze są zazwyczaj używane do działań gaśniczych pożarów cieczy palnych, przy których wykorzystane są ich właściwości izolacyjne, uszczelniające oraz tłumiące proces spalania. Celem tego artykułu jest podjęcie rozważań i analiza porównawcza powszechnie używanych pian gaśniczych w słowackim departamencie przeciwpożarowym, rozpatrując nie tylko ich wysoką skutecznością gaśniczą (zdolność podawania ich podczas gaszenia pożarów o dużej powierzchni, przy niskim poziomie ich zużycia) ale również ich oddziaływanie na środowisko naturalne uwzględniając ich każdy cykl życia. Piany gaśnicze są zazwyczaj używane w celu zmniejszenia rozprzestrzeniania strefy spalania i gaszenia pożarów klasy B oraz zapobieganiu ponownego ich zapalenia. Piany użyte w analizie są używane do ochrony przed zapłonem rozlewisk cieczy palnych i w pewnych warunkach do gaszenia pożarów klasy A. Piany testowane mogą być użyte w kombinacjach z innymi substancjami tłumiącymi proces spalania, głównie gazami i proszkami. Współczesne piany gaśnicze muszą posiadać nie tylko odpowiednie właściwości fizyczne ale również w ostatnich czasach muszą spełniać przepisy REACH dotyczące właściwości ekologiczno-toksykologiczne. Jeśli piany gaśnicze używane są do gaszenia pożarów o dużych powierzchniach, to pod wpływem czasu, wyciekająca z piany woda, przypomina potok wody i gleby, który zmywa powierzchnię ziemi jednocześnie ją zanieczyszczając. Zastosowane w artykule wszystkie typy pian posiadają różne charakterystyki toksykologiczne, stąd też składniki pian decydują o szybkości biodegradowalności pian. Test toksykologiczny Sinapis alba ukazuje znaczącą toksyczność pian nawet przy ich niskich stężeniach. Artykuł ukazuje analizę dla czterech pian utworzonych ze środków pianotwórczych: Sthamex AFFF 1 %, Sthamex AFFF F-15, Pyronil, Moussol APS F-15. Jest niezbędna znajomość ich właściwości m.in. ich stabilności w niskich i wysokich temperaturach określonych jako czasy pół trwania, liczbę spienienia określoną dla ciężkiej, średniej i lekkiej piany a także ich lepkości w celu odpowiedniego wyboru rodzaju pian do prowadzenia działań ratowniczo-gaśniczych.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2012, 1; 29-35
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Povyšenie èffektivnosti gazovogo požarotušeniâ udarnoj volnoj
Increasing the Effectiveness of Fire Extinguishing using a Gas Method which Applies a Shock Wave
Zwiększenie skuteczności gaszenia pożarów metodą gazową z wykorzystaniem fali uderzeniowej
Autorzy:
Balanyuk, V. M.
Powiązania:
https://bibliotekanauki.pl/articles/373516.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
shock wave
gas fire extinguishing
fire extinguishing concentration
diffusion flame
pożar
fala uderzeniowa
gaszenie gazowe
stężenie gaśnicze
płomień dyfuzyjny
Opis:
Objective: Determine the parameter in order to increase the effectiveness of fire extinguishing of CO2 and N2, as well as the power of the shock wave when they are all applied to extinguish a diffusion flame of n-heptane С7N16. Determine the properties of the proposed combined method of extinguishing the diffusion flame of n-heptane in a special test chamber. Methods: In order to determine the potential of the method of extinguishing the diffusion flame of n-heptane using, at the same time, CO2 and N2 and a shock wave, which occurs during the explosion of a pyrotechnic charge, a test station was prepared. It was a chamber of a volume of 0.5 m3 where a shock wave generator was located, and a crucible with n-heptane was placed at a distance of 1.75 m from it. Gas was delivered through a gasometer. The pressure at the front of the shock wave was measured using a pressure sensor and a temperature BMP180 for Arduino controllers, where the work is based on the piezoresistive effect. Visualization of the process of using, at the same time, CO2 and N2 and a shock wave was performed using Nikkon 1 j4 camera with the ability to record images at the speed of 1200 frames per second. Results: In this paper experimentally justified was the fact that combined action of a shock wave and CO2 or N2 on the n-heptane flame, in the chamber at a distance of 2 meters leads to its supression by bursting and defragmentation. Moreover it was experimentally proven that the extinguishing effect of the shock wave with the front pressure of 125 Pa ensures extinguishing with CO2 at a concentration level of 20.3% and N2 at 30.2%. Increasing the power of the shock wave up to 180 Pa allows to reduce the extinguishing concentration of CO2 to 8.2% and of N2 to 15.4%. Based in the analysis of a series of shots, it can be observed that the extinguishing time in comparison to extinguishing method using only a shock wave with the front pressure of approximately 215 Pa is three times shorter. Conclusions: The possibility of a significant increase in the efficiency of extinguishing using CO2 and N2 gases and a shock wave based on the example of a test n-heptane fire in a chamber at a distance of 2 meters was justified and experimentally demonstrated in this paper. Moreover, it has been proven experimentally that during extinguishing a n-heptane diffusion flame using a shock wave of 180 Pa, the necessary concentration of CO2 is reduced by two and a half, and in case of N2 – two times. The experiment confirmed that as a result of simultaneous use of a shock wave and extinguishing gas extinguishing, the time to extinguish the n-heptane diffusion flame significantly shortened. In the case of the CO2 the time required to extinguish the flame is 7 times shorter and in case of N2 it is up to 4.2 times faster as compared to extinguishing the flame using only a shock wave, which takes 350 milliseconds. The features of the proposed combined method of extinguishing the diffusion flame in a special chamber were determined using an experimental method. This includes, in particular, the fact that the start time of defragmentation is greatly reduced and the flame becomes less fragmented. As a result, the extinguishing process takes less time.
Cel: Określenie parametrów mających na celu zwiększenie skuteczności gaśniczej CO2 i N2 oraz mocy fali uderzeniowej przy ich jednoczesnym zastosowaniu do gaszenia płomienia dyfuzyjnego n-heptanu C7H16. Określenie właściwości zaproponowanego łączonego sposobu gaszenia płomienia dyfuzyjnego n-heptanu w warunkach specjalnej komory testowej. Metody: Do określenia możliwości metody gaszenia płomienia dyfuzyjnego n-heptanu za pomocą jednoczesnego gazów CO2 i N2 i fali uderzeniowej, powstałej w wyniku wybuchu ładunku pirotechnicznego, przygotowane zostało stanowisko w postaci komory o objętości 0,5 m3, w której umieszczony został generator fal, a w odległości 1,75 m tygiel z n-heptanem. Gaz dostarczany był przy użyciu gazometru. Ciśnienie na czole fali uderzeniowej mierzono za pomocą czujnika ciśnienia i temperatury BMP180 dla kontrolerów Arduino, którego praca jest oparta na działaniu piezorezystancyjnym. Wizualizację procesu jednoczesnego gaszenia gazami CO2 i N2 oraz falą uderzeniową przeprowadzono z wykorzystaniem kamery Nikon 1 j4 z możliwością zapisu zdjęć z prędkością 1200 kadrów na minutę. Wyniki: W pracy uzasadniono i wykazano eksperymentalnie, że wspólne działanie na płomień n-heptanu fali uderzeniowej i gazów CO2 i N2, w komorze w odległości 2 metrów prowadzi do jego tłumienia poprzez rozerwanie i defragmentację. Eksperymentalnie udowodniono, że działanie gaśnicze fali uderzeniowej o ciśnieniu na czole w wysokości 125 Pa zapewnia gaszenie CO2 w stężeniu 20,3% i N2 przy stężeniu 30,2%. Zwiększenie mocy fali uderzeniowej do 180 Pa pozwala na zmniejszenie stężenia gaśniczego CO2 do 8,2% i N2 do 15,4%. Na podstawie analizy serii ujęć można zaobserwować, że czas gaszenia w porównaniu do gaszenia tylko falą uderzeniową o ciśnieniu (na czole) około 215 Pa jest trzykrotnie krótszy. Wnioski: W pracy uzasadniono i dowiedziono eksperymentalnie możliwość znaczącego zwiększenia skuteczności gaśniczej gazów CO2 i N2 z wykorzystaniem fali uderzeniowej na przykładzie testowego pożaru n-heptanu w komorze w odległości do 2 metrów. Udowodniono eksperymentalnie, że podczas gaszenia płomienia dyfuzyjnego n-heptanu falą uderzeniową o mocy 180 Pa potrzebne stężenie CO2 zmniejsza się dwuipółkrotnie, a N2 dwukrotnie. Eksperyment potwierdził, że w rezultacie jednoczesnego zastosowania fali uderzeniowej i gazu gaśniczego znacznemu skróceniu ulega czas gaszenia płomienia dyfuzyjnego n-heptanu. W przypadku z CO2 czas potrzebny do ugaszenia płomienia jest 7 razy krótszy, a N2 do 4,2 razy krótszy w stosunku do gaszenia wyłącznie falą uderzeniową, które zajmuje 350 milisekund. Metodą eksperymentalną określono cechy zaproponowanej łączonej metody gaszenia płomienia dyfuzyjnego w warunkach specjalnej komory. Należy do nich m.in. fakt, że czas rozpoczęcia fragmentacji znacznie się skraca i płomień ulega mniejszej fragmentacji. Dzięki temu gaszenie trwa krócej.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 43, 3; 81-93
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Povyšenie ognetušaŝej èffektivnosti binarnyh gazoaèrozolʹnyh smesej udarnymi volnami
The Increase of Fire Extinguishing Efficiency of Gas-Aerosol Binary Mixture Using Shock Waves
Zwiększenie skuteczności gaśniczej binarnych mieszanin gazowo-aerozolowych za pomocą fal uderzeniowych
Autorzy:
Balanyuk, V. M.
Powiązania:
https://bibliotekanauki.pl/articles/373928.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
shock wave
gas
aerosol fire extinguishing
fire extinguishing concentration
pożar
fala uderzeniowa
gaszenie gazem
gaszenie aerozolem
stężenie środka gaśniczego
Opis:
Objective: Determination of the n-heptane diffusion flame-extinguishing efficiency of the combined method which uses a fire extinguishing aerosol, CO2 gases (N2) and the simultaneous impact in their environment of shock waves. The identification of a possible extinguishing mechanism for this method. Methods: In order to determine the possibility of extinguishing the diffusion flame of n-heptane by the combined use of CO2 or N2 gases, aerosol and the shock wave created by the explosion of the pyrotechnic charge, an experimental chamber was set up with a volume of 0.5 m3. Inside the chamber, a shock wave generator was installed, and a crucible with n-heptane was placed at a distance of 1.75 m from it. The gas was fed to the chamber through a gas meter. The pressure in front of the shock wave was measured with a BMP-180 pressure and temperature sensor for the Arduino controller, which operates on a piezoresistive basis. The photographic documentation of the extinguishing process by the combined action of aerosol, CO2 and N2 gases, and a shock wave was done using the Nikkon 1j4 camera with a frame rate of 1200 frames per second. Results: The scientific aspects of the increase in the fire-extinguishing efficiency of the gas-aerosol mixture are theoretically substantiated and experimentally confirmed in this paper. Accordingly, the combined impact of a series of shock waves and CO2 or N2 gases mixed with aerosol on the flame of n-heptane inside a chamber, leads to a significant increase in the extinguishing efficiency of such a method. It has also been demonstrated that the extinguishing aerosol concentrations decrease 8 times, and the gases concentration in the binary mixture with the aerosol decreases 4,6 times for CO2, and 4 times for N2 in a relation to their individual extinguishing concentrations when the diffusion flame of the n-heptane is exposed to a series of 3 shock waves with a frequency of 10 Hz and a total power of only 240 Pa. Conclusion: The characteristics of extinguishing the diffusion flame of n-heptane under the conditions of a special chamber were determined experimentally using the proposed combined extinguishing method. The tests have shown that the time for the onset of fragmentation decreases significantly after exposure to a series of shock waves, and the flame is then detached and dispersed at much lower concentrations of aerosol and gas mixture, which leads to faster extinguishing.
Cel: Określenie skuteczności gaśniczej połączonych trójskładnikowych systemów gaśniczych wykorzystujących aerozol gaśniczy, gazy CO2 (N2) oraz jednoczesne oddziaływanie w ich środowisku fal uderzeniowych w gaszeniu płomienia dyfuzyjnego n-heptanu. Wyznaczenie możliwego mechanizmu gaśniczego omawianego sposobu. Metody: W celu zbadania możliwości gaszenia płomienia dyfuzyjnego n-heptanu przy jednoczesnym zastosowaniu gazów CO2 lub N2, aerozolu i fali uderzeniowej powstającej wskutek wybuchu ładunku pirotechnicznego zbudowane zostało stanowisko badawcze w postaci komory o objętości 0,5 m3. W komorze umieszczono generator fal uderzeniowych, a w odległości 1,75 m od niego – tygiel z n-heptanem. Gaz dostarczany był do komory poprzez licznik gazowy. Pomiary ciśnienia na froncie fali uderzeniowej były wykonywane za pomocą czujników ciśnienia i temperatury BMP-180 kontrolera Arduino, działającego na zasadzie piezorezystancji. Dokumentacja zdjęciowa procesu gaśniczego z jednoczesnym działaniem aerozolu, gazów CO2 i N2 oraz falą uderzeniową była zrealizowana za pomocą aparatu Nikon 1j4, umożliwiającego rejestrację obrazu z szybkością 1200 klatek na sekundę. Wyniki: W artykule w sposób teoretyczny i eksperymentalny potwierdzone zostały aspekty naukowe zwiększenia skuteczności gaśniczej mieszaniny gazów i aerozolu. Zgodnie z nimi połączone oddziaływanie na płomień n-heptanu serii fal uderzeniowych oraz gazów CO2 lub N2 zmieszanych z aerozolem w komorze badawczej pozwala na znaczne zwiększenie skuteczności gaśniczej tej metody. Wykazano również, że przy działaniu na płomień dyfuzyjny n-heptanu serii 3 fal uderzeniowych o częstotliwości 10 Hz i mocy całkowitej 240 Pa stężenie gaśnicze aerozolu zmniejsza się ośmiokrotnie, a stężenie gazów w binarnej mieszaninie z aerozolem w przypadku CO2 zmniejsza się o 4,6 razy, a dla N2 o 4 razy w stosunku do stężeń gaśniczych tych substancji z osobna. Wniosek: W drodze eksperymentu określono właściwości gaszenia płomienia dyfuzyjnego n-heptanu w warunkach specjalnej komory za pomocą zaproponowanej potrójnej metody. Badania wykazały, że po przejściu serii fal uderzeniowych czas rozpoczęcia fragmentaryzacji ulega znaczącemu skróceniu. Jednocześnie płomień odrywa się i dysperguje przy dużo niższych stężeniach mieszaniny aerozolu z gazem, umożliwiając szybsze gaszenie.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 46, 2; 72-86
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Tušenie diffuzionnogo plameni n-geptana udarnoj volnoj
Extinguishment of N-heptane Diffusion Flames with the Shock Wave
Gaszenie płomienia dyfuzyjnego n-heptanu z wykorzystaniem fali uderzeniowej
Autorzy:
Balanyuk, V. M.
Powiązania:
https://bibliotekanauki.pl/articles/373061.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
shock wave
fire extinguishing
fire suppression
diffusion flame
pożar
fala uderzeniowa
gaszenie pożarów
płomień dyfuzyjny
Opis:
Objective: To determine the effectiveness of extinguishing diffusion flames of n-heptane with a shock wave (SW). Establishing a possible mechanism of suppression of diffusion flame with a shock wave on n-heptane С7Н16 flame. Determination of the intensity of the shock wave, which leads to extinguishing n-heptane flame under a special camera. Methods: To determine the possibility for extinguishing the diffusion flame by a shock wave, which occurs during the explosion of a pyrotechnic charge, equipment that looked like a camera with volume of 0.5 m3 was installed. A surge generator was placed inside it and a crucible with n-heptane was located at a distance of 1.75 m. The pressure measurement at the front of the shock wave was conducted using BMP-180 pressure sensor for Arduino controllers. Visualization of the extinguishing process of the shock wave was carried out using Nikon 1 j4 camera with the possibility of obtaining frames at a speed of 1200 frames per second. Results: This article presents as an experiment that the impact of a shock wave with front pressure of about 215 Pа in the chamber at a distance up to 2 meters on n-heptane flame, oleads to its suppression by tearing and defragmentation. Time periods, which confirm the effectiveness of fire-extinguishing of the shock wave, and the transition states of instability have been recorded on video at a frequency of 1200 frames per second. This way respective stages of the storyboard, time periods of flame instability at a pressure of 190 Pa SW, and extinguishing time capacity SW of 215 and 316 Pa were obtained . Conclusions: Extinguishing diffusion flames of n-Heptane shock wave with a power equal to approximately 215 Pа created in the chamber at a distance of 2 meters were theoretically analyzed and experimentally proven to be highly effective e. Based on presented theoretical deliberations a possible mechanism of interaction of shock wave – flame was created. As a result of tearing of the flames, reduction of the following parameters takes place: concentration of the reactants in the combustion zone, pressure, introducing additional gaseous components into the combustion zone, and a sharp decrease in temperature of gasaround the flame. The proposed extinguishing method can guarantee efficient extinguishing of diffusion flames at the initial stage of a fire in hard to reach places and spaces with flammable liquids.
Cel: Zbadanie skuteczności gaszenia płomienia dyfuzyjnego n-heptanu falą uderzeniową. Określenie możliwego mechanizmu gaszenia płomienia dyfuzyjnego falą uderzeniową na przykładzie płomienia n-heptanu С7Н16. Ustalenie mocy fali uderzeniowej, przy której rozpoczyna się proces gaszenia w warunkach laboratoryjnych przy użyciu specjalnej komory. Metody: W celu określenia możliwości gaszenia płomienia dyfuzyjnego falą uderzeniową, która powstaje podczas eksplozji ładunku pirotechnicznego przygotowano specjalnie wyposażone stanowisko z komorą o objętości 0,5m3, w której umieszczono generator fal uderzeniowych, a w odległości 1,75 m tygiel z n-heptanem. Pomiar ciśnienia na froncie fali uderzeniowej wykonywany był za pomocą czujnika ciśnienia i temperatury BMP-180 dla kontrolerów Arduino, praca którego oparta jest na działaniu piezorezystancyjnym. Wizualizację procesu gaszenia falą uderzeniową przeprowadzono z wykorzystaniem kamery Nikon 1 j4 z możliwością zapisu ujęć z prędkością 1200 kadrów na sekundę. Wyniki: W artykule wykazano eksperymentalnie, że wpływ fali uderzeniowej o cieśnieniu na jej froncie wynoszącym ok. 215 Pa na płomień n-heptanu w komorze w odległości do 2 metrów, prowadzi do jego tłumienia poprzez rozerwanie i defragmentację. Zakresy czasowe, które potwierdzają skuteczność gaszenia falą uderzeniową oraz przejściowe stany niestabilności zostały zarejestrowane na taśmę wideo z prędkością 1200 kadrów na s. W ten sposób otrzymano serię ujęć każdego etapu, okresów niestabilności płomieni przy ciśnieniu fali uderzeniowej równej 190 Pa, oraz chwili gaszenia fali o mocy 215 i 316 Pa. Wnioski: W pracy przeanalizowano teoretycznie oraz udowodniono eksperymentalnie wysoką skuteczność metody gaszenia płomienia dyfuzyjnego n-heptanu falą uderzeniową o mocy równej ok. 215 Pa powstałą w komorze, w odległości do 2 metrów. Na podstawie przedstawionych rozważań teoretycznych opracowano możliwy mechanizm oddziaływania fala uderzeniowa – płomień. W wyniku rozerwania płomieni dochodzi do spadku parametrów takich jak: koncentracja substratów reakcji w strefie spalania, ciśnienia oraz wprowadzenia do strefy spalania dodatkowych składników gazowych oraz gwałtownego spadku temperatury gazów wokół płomienia. Zaproponowana metoda gaśnicza może zagwarantować skuteczne gaszenie płomieni dyfuzyjnych w ich początkowym stadium w zamkniętych i trudno osiągalnych miejscach oraz pomieszczeniach z płynami palnymi.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 42, 2; 103-111
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Rascet parametrov podaci ognetushashchich veshchestv distancionno-upravljaemykh sredstv dlja tushenija poligona tverdykh bytovykh otkhudov
Calculation parameters of the remote‑controlled extinguishing device for landfill fires
Obliczanie parametrów zdalnie sterowanych urządzeń stosowanych do gaszenia pożarów na wysypiskach twardych odpadów komunalnych
Autorzy:
Loyk, V.B.
Lazarenko, А.V.
Powiązania:
https://bibliotekanauki.pl/articles/136431.pdf
Data publikacji:
2016
Wydawca:
Szkoła Główna Służby Pożarniczej
Tematy:
fire
hydraulic calculation
deluge sprinkler
municipal solid waste landfill
fire extinguishing
pożar
obliczenia hydrauliczne
potop tryskaczowy
wysypisko odpadów komunalnych
gaszenie pożaru
Opis:
The use of a remotely controlled sprinkler device, “deluge sprinkler” installation to extinguish fire at landfills of solid waste has been proposed in the article. According to the project the use of such remote controlled installations require laws with basic tactical and technical data. The scheme of the system and the results of hydraulic calculations to the project of the extinguishing device have been proposed. On the basis of these calculations required minimum pressure and water flow rate for the designed extinguishing system have been specified.
W artykule opisano zastosowanie zdalnie sterowanych urządzeń typu zraszacze (instalacji „potopu tryskaczowego”) do gaszenia pożaru na wysypiskach twardych odpadów komunalnych. Stosowanie takich instalacji wymaga odpowiednich przepisów prawnych, przy tworzeniu których należy brać pod uwagę podstawowe dane taktyczne i techniczne urządzeń. Przedstawiony w artykule schemat układu jest wynikiem przeprowadzonych obliczeń hydraulicznych potrzebnych do zaprojektowania takiego urządzenia gaśniczego. Na podstawie tych obliczeń określono wymagane minimalne ciśnienie i prędkość przepływu wody, jakie jest wymagane dla projektowanego systemu gaśniczego.
Źródło:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej; 2016, 4, 60; 79-93
0239-5223
Pojawia się w:
Zeszyty Naukowe SGSP / Szkoła Główna Służby Pożarniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Podhod k matematičeskomu modelirovaniû razvitiâ i tušeniâ požarov, voznikaûŝih v kanalah različnymi sredstvami
Wstęp do matematycznego modelowania rozwoju i gaszenia pożarów w tunelach różnymi metodami
The Approach to Mathematical Modelling of Fire Development and Its Extinguishing in Tunnels by Different Means
Autorzy:
Kovalyshyn, V. V.
Powiązania:
https://bibliotekanauki.pl/articles/372996.pdf
Data publikacji:
2013
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
kanał
pożar
gaszenie
proszek
mgła wodna
piana
recyrkulacja
mieszanina parowo-gazowa
model matematyczny
gazy szlachetne
channel
fire
fire extinguishing
powder
dispersed water
foam
recycling
water-vapor mixture
mathematical model
inert gases
Opis:
Cel: Celem pracy było opracowanie uniwersalnego modelu matematycznego, który pozwala wygenerować na komputerze graficzną prognozę skutecznego zastosowania jednej z pięciu możliwych metod gaśniczych: recyrkulacji gazów pożarowych, użycia proszku, mgły wodnej, mieszaniny parowo-gazowej lub piany na bazie produktów spalania. Stworzenie modelu było możliwe dzięki prawidłowościom odkrytym w procesach rozwoju i gaszenia pożarów w obiektach o dużej długości. Prawidłowości wykazano w drodze analizy teoretycznych i eksperymentalnych badań oraz uogólnionego podejścia do stosowania środków gaszenia pożarów w podłużnych kanałach. Metody: W pracy została wykorzystana kompleksowa metoda badawcza, uwzględniająca analizę i syntezę naukowo-technicznych osiągnięć w zakresie obliczeń wentylacji oraz obliczeń termicznych w czasie wybuchu pożaru w tunelu; matematyczne modelowanie ruchów ciepłych mas powietrza i aerologii z użyciem głównych zasad termodynamiki; symulacyjne modelowanie procesów rozprzestrzeniania strumieni gazowych i temperatury w izolowanej części tunelu kablowego w czasie recyrkulacji produktów spalania; wykorzystanie metod matematyki statystycznej w celu sprawdzenia miarodajności otrzymanych wyników. Wyniki: Opracowany został uniwersalny model matematyczny, algorytm oraz program obliczeń gazowych termodynamicznych parametrów spalania i gaszenia pożaru w odizolowanej części kanału z użyciem jednej z pięciu możliwych metod gaśniczych lub ich kombinacji. Model matematyczny czasowej dynamiki zawartości tlenu w ognisku pożaru i poza jego granicami został opracowany z użyciem metody numerycznej oraz równań różniczkowych opisujących niestacjonarny transport mas, które obliczane były metodą liczbową według układu kombinacyjnego (jawnego i niejawnego z jednakowym ciężarem właściwym) i zredukowane do systemu równań algebraicznych. Opracowany został algorytm i program obliczeń w programie komputerowym Excel zmian w czasie koncentracji tlenu w źródle pożaru i poza nim, dynamiki temperatury w źródle i w otaczających go masach. Wnioski: Podsumowano wyniki opracowania modelu matematycznego, odpowiadające wielu danym eksperymentalnym na temat rozwoju i gaszenia pożarów różnymi metodami w podłużnych kanałach. Opracowany został uniwersalny model matematyczny dający możliwość w przypadku zastosowania tego lub innego środka gaśniczego wyliczyć parametry intensywności i czasu jego oddziaływania podczas gaszenia źródła pożaru. Model pozwala również określić niezbędną ilość materiału gaśniczego. Otrzymane wyniki mogą pomóc w ocenie wybranego środka gaśniczego przy jednoczesnej wizualnej weryfikacji jego zalet i wad. Wyniki te można wykorzystywać przy tworzeniu planów usuwania sytuacji nadzwyczajnych.
Objective: The objective of the research was to develop an universal mathematical model which could be displayed in a computer programme as a graphic forecast of the effectiveness of one of the five possible fire extinguishing methods, such as fire gas recirculation, the usage of powder, water mist, vapor-gas mixture or foam. Creation of the model was possible on the basis of the process of development and fighting fires in constructions of considerable length. Obtained by the general results of theoretical and experimental studies. The research was also based on the generalized approach to the use of firefighting equipment in elongated channels. Methods: The methods used in the analysis comprised a complex method of research which involved an analysis and synthesis of scientific and technological achievements in the field of ventilation and thermal calculations during a fire in the tunnel; the mathematical modelling of heat and mass transfer in accordance with basic laws of thermodynamics; simulation modelling of the gas flow and temperature distribution in the isolated area of a cable tunnel during recirculation of combustion products. For testing the reliability of the results we also used the statistical techniques. Results: As the result of the work we obtained the universal mathematical model, the algorithm and the program for calculating thermodynamic parameters of the process of gas burning and fire suppression in the isolated channel volume with the use of one out of five possible firefighting methods or their combination. Mathematical modelling of the temporal concentration of oxygen in the outbreak or beyond the fire was performed with the use of differential equations of unsteady mass transfer, which were solved numerically by the combined scheme and reduced to a set of algebraic equations. The algorithm and the programme for calculating in Excel the temporal concentration of oxygen and the dynamics of the temperature in the source of the fire and in the ambient array were developed. Conclusions: The authors recapped the results of the mathematical modelling which turned out to be equivalent to numerous experimental data on the development and extinguishing of fires in elongated channels. As a result the universal mathematical model for calculations of intensity and exposure time parameters as well as for determining the amount of fire-extinguishing material was created. The obtained results allow to evaluate the extinguishing agent and to verify visually its advantages or disadvantages. These results can be used in the preparation of emergency response plans and other documents.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2013, 4; 37-42
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ustrojstvo vrezki v produktoprovod dlâ podači vozdušno-mehaničeskoj ognetušaŝej peny v gorâŝij rezervuar
A Device for Cutting Holes in the Pipelines in Order to Supply a Burning Storage Tank with Air-Mechanical Firefighting Foam
Urządzenie do wcięcia się w rurociąg w celu podania powietrzno-mechanicznej piany gaśniczej do płonącego zbiornika
Autorzy:
Malashenko, S. M.
Smilovenko, O. O.
Emelyanov, V. K.
Chernevich, O. V.
Powiązania:
https://bibliotekanauki.pl/articles/373724.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
air-mechanical foam fire extinguishing
subsurface method extinguishing oil and petroleum products
built-in bandage
pipeline valve
pożar
powietrzno-mechaniczna piana gaśnicza
podpowierzchniowa metoda gaszenia ropy i produktów ropopochodnych
zawór
wbudowany bandaż
Opis:
Objective: Improvement of subsurface extinguishing technique of oil and oil products fires in storage tanks. Introduction: One of priority directions in prevention of large-scale oil and oil products leaks is the fire protection of oil and oil products storage tanks. An emergence of a fire in one of the tanks in the storage tank facility, failure in its localizing and suppressing can lead to the damage to the tank, leakage of oil or oil products, fast spread of a fire through the entire storage tank complex, destruction of other tanks and even more large-scale leaks of oil and its products. The subsurface method of low expansion foam application is possible not only thanks to the foam pipelines of fire extinguishing systems, but also through the utility lines (oil pipelines, lines for washing out ground deposits), located in the lower part of a tank. Thus, the risk of a damage to the foam generators and pipelines of suppression system due to explosions and thermal streams is completely excluded. Low expansion foam arriving from foam generators located behind the protective dike pushes out the fuel from the pipelines and arrives into the tank. Conclusions: An operative cutting integrated device (further – OCID) for cutting holes in utility lines and transferring fire extinguishing air-mechanical low expansion foam into the fuel layer has been designed and constructed. The OCID can be installed on the pipelines of 159, 168 or 219 mm of external diameter and with lacquer coating. The tactical and technological methods of the operative cutting integrated device for utility lines of storage tanks, designed for the implementation of subsurface method of fire extinguishing have been experimentally developed. Implementation of OCID allows to transfer the foam under the layer of burning oil product in the storage tank not equipped with stationary mounted foam pipeline for extinguishing purposes. Application of the OCID will increase the efficiency of fire extinguishing and will provide higher level of staff’s safety. Implications for practice: Fire extinguishing of oil and oil products in storage tanks not equipped with stationary fire-extinguishing system with the help of subsurface method is principally possible through the utility lines. Supply of air and mechanical foam is carried out both through the existing branch pipes and in the branches which are received by the way of the operative cutting integrated device. The tasks of the operative cutting integrated device are solved with the help of serially produced equipment.
Cel: Udoskonalenie taktyki gaszenia metodą podpowierzchniową pożarów w zbiornikach z ropą i substancjami ropopochodnymi. Wprowadzenie: Jednym z priorytetowych kierunków w zapobieganiu wielkoskalowym wyciekom ropy i produktów ropopochodnych jest ochrona przeciwpożarowa obiektów do przechowywania ropy i jej pochodnych. Wybuch pożaru w jednym ze zbiorników w całym jego kompleksie, niewłaściwe zlokalizowanie i gaszenie pożaru mogą doprowadzić do uszkodzenia zbiornika, wycieku ropy lub ropopochodnych, szybkiego rozprzestrzenienia się pożaru na cały kompleks zbiorników, uszkodzenia innych zbiorników i jeszcze większego wycieku ropy i produktów ropopochodnych. Podanie piany o niskiej liczbie spienienia (piany ciężkiej) metodą podpowierzchniową jest możliwe nie tylko poprzez przewody systemu gaśniczego, lecz także poprzez rury technologiczne (rurociągi naftowe, przewody do oczyszczania z osadów dennych) zlokalizowane w dolnej części zbiornika. Przy tym praktycznie całkowicie wyklucza się możliwość uszkodzenia generatorów piany i rur technologicznych wskutek wybuchów i strumieni ciepła. Piana o niskiej liczbie spienienia wychodząca z generatorów piany umieszczonych za barierą ochronną wypycha z rurociągów paliwo i trafia do zbiornika. Wnioski: Opracowano i skonstruowano urządzenie do operacyjnego wcięcia się w celu wywiercenia otworów w rurach technologicznych i następnie podania powietrzno-mechanicznej piany gaśniczej o niskiej liczbie spienienia do warstwy paliwa. Urządzenie ustawiane jest na rurociągach o zewnętrznej przekątnej 159, 168 lub 219 mm z pokryciem lakierniczym. Przeprowadzono badania eksperymentalne zastosowania urządzenia do wcięcia się w rury technologiczne zbiorników w celu realizacji gaszenia metodą podpowierzchniową. Z pomocą urządzenia podawana jest piana pod powierzchnię płonącego produktu naftowego w zbiorniku niewyposażonym w zamontowany na stałe przewód do podawania piany gaśniczej. Zastosowanie urządzenia zwiększy efektywność gaśniczą oraz zapewni większy poziom bezpieczeństwa załogi. Znaczenie dla praktyki: Gaszenie metodą podpowierzchniową ropy i produktów naftowych w zbiornikach niewyposażonych w stacjonarne systemy gaśnicze jest zasadniczo możliwe dzięki rurom technologicznym. Podawanie powietrzno-mechanicznej piany jest realizowane poprzez dostępne kolanka, jak również przez odgałęzienia otrzymane dzięki wcięciu. Zadanie wycięcia otworu przeprowadzane jest za pomocą sprzętu produkowanego seryjnie.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 2; 115-122
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Matematičeskaâ modelʹ i ocenka riska likvidacii požara
Мathematical Model and Risk Evaluation for Firefighting
Model matematyczny i ocena ryzyka zwalczania pożaru
Autorzy:
Vasiľev, N. I.
Movchan, I. A.
Powiązania:
https://bibliotekanauki.pl/articles/373029.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
extinguishing a fire
probability of extinguishing a fire
mathematical model
Weibull exponential distribution
normal distribution
information technology
pożar
zwalczanie pożaru
ryzyko zwalczania pożaru
model matematyczny
rozkład Weibulla
rozkład wykładniczy
rozkład normalny
technologie informacyjne
Opis:
Aim: The purpose of this article is to identify risks during firefighting operations, utilizing the basic principles of reliability theory, but also functional probability models, for all stages of the firefighting processes. With the aid of acquired data, develop a mathematical model to describe uncertainties associated with various phases of firefighting and define the influence of component parts, through projects and programmes for each operational element, on the overall outcome in the fight with a fire. Methodology: The article utilised a complex approach to identify the probability of overcoming a fire within required timescales, by taking account of all tasks associated with the process. The probabilistic description of each component was based on the use of standard time for the completion of a given task. In order to determine each component of risk, the study utilised Weibull’s distribution, exponential and normal laws of distribution. During the selection of distribution laws use was made of statistical modelling methods to determine the confidence levels for each operational task. Results: Study results facilitate identification of weak areas in the operational performance of teams engaged in firefighting. From an analysis of factors influencing the quality of performance, adverse performance can be eliminated and consequently the effectiveness of firefighting can be significantly improved. Illustratively, the project development of access road selection and use of optimal routes within the operational boundary systems, to determine resource needs in fighting fires and by taking account of predicted timescales for undisturbed burning, will significantly reduce the probability value of failure in extinguishing fires within appropriate/desired time scales. Conclusions: The proposed method for determining the probability of combating fires enables, on the basis of statistical data dealing with lead time for extinguishing fires, the conduct of work analysis for firefighting teams and to diagnose their weaknesses. Analysis of results reveals that the main weakness in team performance is the time taken for the journey to an incident location. Calculations indicate that, in order to reduce the time taken to locate and extinguish the fire, and clear the site of the incident, it is necessary to have at disposal an optimal number of firefighting teams.
Cel: Celem artykułu jest opracowanie metody określenia ryzyka procesu zwalczania pożaru w chronionym obiekcie z wykorzystaniem podstawowych założeń teorii niezawodności, a także funkcjonalnych modeli ryzyka dla każdej operacji taktycznej w procesie zwalczania pożaru. Następnie, z wykorzystaniem otrzymanych danych, opracowanie modelu matematycznego ryzyka zwalczania pożaru oraz określenie wpływu składowych ryzyka operacji taktycznych na zabezpieczenie poprzez projekty i programy każdej operacji taktycznej wpływającej na skuteczność zwalczania pożaru. Metody: W artykule wykorzystano kompleksowe podejście do określenia ryzyka przy zwalczaniu pożaru w wymaganym czasie z uwzględnieniem wszystkich operacji taktycznych związanych z tym procesem. Jako podstawę określenia każdej składowej ryzyka wykorzystano normatywny czas na wykonanie danej operacji taktycznej. Do określenia każdej składowej ryzyka wykorzystano zależności rozkładu Weibulla, rozkładu prawa wykładniczego i normalnego. Przy wyborze prawa rozkładu posługiwano się metodą modelowania statystycznego parametrów niezawodności każdej operacji taktycznej. Wyniki: Wyniki badania pozwalają określić słabe punkty w działaniach zespołów ratowniczo-gaśniczych. Dzięki analizie czynników wpływających na jakość pracy można będzie wyeliminować te negatywne i przez to znacząco zwiększać skuteczność zwalczania pożarów. Przykładowo opracowanie projektu wyboru optymalnych dróg dojazdowych do granic obsługiwanego przez daną jednostkę obszaru pozwala skrócić czas dojazdu na miejsce zdarzenia o 30-35%, a zastosowanie zautomatyzowanych systemów obliczania sił i środków potrzebnych do zwalczania pożarów z uwzględnieniem prognozowanego czasu niezakłóconego spalania znacząco zmniejsza wartość ryzyka nieugaszenia pożaru w odpowiednim/wymaganym czasie. Wnioski: Zaproponowana metoda określenia ryzyka przy zwalczaniu pożaru pozwala, na podstawie danych statystycznych na temat czasu gaszenia pożarów, przeprowadzić analizę pracy zespołów ratowniczo-gaśniczych i zdiagnozować jej słabe punkty. Wyniki analizy ryzyka przy zwalczaniu pożaru pokazują, że głównym słabym punktem w pracy zespołów jest czas dojazdu na miejsce zdarzenia. Aby zmniejszyć czas lokalizacji, gaszenia i dogaszania pożaru, jak pokazały wyniki obliczeń, należy dysponować optymalną liczbę zespołów ratowniczo-gaśniczych.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 41, 1; 47-54
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wygaszanie płomienia falą akustyczną
Flame extinguishing by the acoustic wave
Autorzy:
Radomiak, H.
Łukasiak, K.
Matysiak, H.
Musiał, D.
Bala-Litwiniak, A.
Powiązania:
https://bibliotekanauki.pl/articles/103611.pdf
Data publikacji:
2016
Wydawca:
Uniwersytet Humanistyczno-Przyrodniczy im. Jana Długosza w Częstochowie. Wydawnictwo Uczelniane
Tematy:
gaszenie płomienia
fala akustyczna
spalanie
pożar
flame extinguishing
acoustic wave
combustion
fire
Opis:
Płomień w pewnych przypadkach może być śmiertelnym zagrożeniem dla życia, zdrowia lub mienia ludzi. Dlatego też w czasie pożaru potrzebna jest szybka reakcja, mająca na celu ugaszenie lub przynajmniej zapobiegnięcie rozprzestrzenianiu się ognia. Oprócz znanych, konwencjonalnych metod gaszenia pożaru (woda, piana, dwutlenek węgla) można też zastosować falę dźwiękową. Fala akustyczna właściwie ukierunkowana, o określonej częstotliwości i mocy niesie ze sobą odpowiednią ilość energii, która powoduje sinusoidalne zmiany ciśnienia akustycznego i, natrafiając na płomień, przyczynia się do zerwania jego strugi i rozdzielenia na wiele części. W niniejszej pracy przedstawiono wpływ drgań akustycznych na stabilność płomienia wybranych paliw ciekłych oraz określono go dla jakich wartości częstotliwości oraz mocy fali akustycznej nastąpi wygaszenie tego płomienia. Odpowiednie badania przeprowadzono dla oleju napędowego, benzyny, parafiny oraz mieszanki gliceryny i oleju napędowego.
In some cases, the flame may be a deadly threat for life, health or property of people. Therefore, in case of fire the fast response aiming to extinguish or at least prevent the spread of fire are very important. Besides the known conventional methods of fire extinguishing such as: water, foam, carbon dioxide, the sound wave can also be employed. Properly oriented acoustic wave of specific frequency and power, generates the appropriate amount of energy, that causes a sinusoidal changes of acoustic pressure, therefore encountering on the flame it contributes to the flame breaking and separation into a number of parts. In this study, the influence of acoustic vibrations on the stability of the flame of chosen liquid fuels were investigated. The effects of frequency and power of the acoustic wave on the flame extinguishing were also determined. Corresponding investigations were carried for diesel, gasoline, paraffin, and mixtures of pharmaceutical glycerin and diesel oil.
Źródło:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa; 2016, T. 4; 377-388
2300-5343
Pojawia się w:
Prace Naukowe Akademii im. Jana Długosza w Częstochowie. Technika, Informatyka, Inżynieria Bezpieczeństwa
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Methods Used to Extinguish Fires in Electric Vehicles
Metody gaśnicze stosowane do gaszenia pożarów samochodów elektrycznych
Autorzy:
Lesiak, Piotr
Pietrzela, Dariusz
Mortka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/2060730.pdf
Data publikacji:
2021
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
lithium-ion battery
Li-Ion
fire
extinguishing
suppression
akumulator litowo-jonowy
pożar
gaszenie
tłumienie
Opis:
Aim: The aim of the article is to present the current state of knowledge regarding the possibility of suppressing or effectively extinguishing fires of electric vehicle. Due to the growing popularity of means of transport powered by electric batteries, the problem of emerging fires and their effects is becoming recognizable. Due to the possible violent process of combustion of lithium-ion batteries (hereinafter referred to as Li-Ion batteries), a fire in a vehicle may lead to a wide range of property damage. For at least a decade, intensive efforts have been made to develop appropriate methods to allow firefighters to deal with the problem of fires of electric vehicles. These activities were directed, among others, at new fire extinguishing/suppression techniques, innovative extinguishing agents and methods of their application. Introduction: Taking into account the current global trends in changing the method of powering vehicles from fossil fuels into electricity, the occurrence of such events should be expected to intensify. The authors systematize the issue by analysing the literature on fires, Li-Ion batteries being a critical element that may initiate a fire. The adopted and practiced methods of extinguishing/suppressing a fire as well as the used extinguishing agents were also analysed. The publication may be an element helpful in selecting the most optimal fire extinguishing method of the electric energy storage unit in a vehicle. Methodology: The review of the current state of knowledge was made based on publications on the fire characteristics of Li-Ion batteries, as well as works and research projects in the field of extinguishing methods and the effectiveness of various extinguishing agents. In addition, the procedures used by the emergency services and selected real events were analysed. Conclusions: Fires of Li-Ion batteries are a relatively new and growing phenomenon. Fires in fully or partially electric vehicles are much more difficult to fully extinguish compared to fires in vehicles with internal combustion engines. So far, no effective method has been developed that would allow a fire to be extinguished in a short time. Activities in this area focus on minimizing the effects. There is still a need to look for new technical and tactical solutions in order to optimize the procedures leading to more effective activities of the services in this type of incidents.
Cel: Celem artykułu jest przedstawienie aktualnego stanu wiedzy w zakresie możliwości tłumienia lub skutecznego ugaszenia pożarów pojazdów elektrycznych. Z uwagi na wzrost popularności środków transportu zasilanych z akumulatorów elektrycznych, rozpoznawalna staje się problematyka pojawiających się pożarów i ich skutków. Z uwagi na możliwy gwałtowny proces przebiegu spalania akumulatorów litowo-jonowych (dalej akumulatory Li-Ion), wystąpienie pożaru w pojeździe może doprowadzić do szerokiego spektrum uszkodzeń mienia. Od co najmniej dekady prowadzone są intensywne działania ukierunkowane na wypracowanie właściwych metod pozwalających strażakom zmierzyć się z problemem pożarów pojazdów elektrycznych. Działania te ukierunkowano m.in. na nowe techniki gaszenia/tłumienia pożaru, innowacyjne środki gaśnicze i sposoby ich aplikacji. Wprowadzenie: Ratownicy coraz częściej spotykają się z pożarami układów gromadzenia energii elektrycznej wykonanych w technologii Li-Ion, w tym stosowanych w pojazdach elektrycznych. Biorąc pod uwagę obecne, światowe trendy zmiany sposobu zasilania pojazdów z paliw pochodzących z kopalin na energię elektryczną, należy spodziewać się intensyfikacji pojawiania się takich zdarzeń. Autorzy systematyzują zagadnienie poprzez analizę literaturową w zakresie pożarów akumulatorów Li-Ion jako krytycznego elementu mogącego zapoczątkowywać pożar. Analizie także poddano przyjęte i praktykowane metody gaszenia/tłumienia pożaru oraz wykorzystane środki gaśnicze. Publikacja może stanowić element pomocny w doborze najbardziej optymalnej metody ugaszenia pożaru zespołu gromadzenia energii elektrycznej w pojeździe. Metodologia: Przeglądu obecnego stanu wiedzy dokonano na podstawie publikacji dotyczących charakterystyki pożarowej akumulatorów Li-Ion, a także prac oraz projektów naukowo-badawczych z zakresu metod gaszenia i efektywności różnych środków gaśniczych. Ponadto analizie poddano procedury stosowane przez służby ratownicze oraz wybrane zdarzenia rzeczywiste. Wnioski: Pożary akumulatorów Li-Ion to stosunkowo nowe i narastające zjawisko. Pożary pojazdów w pełni lub częściowo elektrycznych są znacznie trudniejsze do pełnego ugaszenia w porównaniu do pożarów pojazdów z silnikami spalinowymi. Jak dotąd nie opracowano skutecznej metody, która pozwoliłaby na ugaszenie pożaru w krótkim czasie. Działania w tym obszarze skupiają się na minimalizacji skutków. W dalszym ciągu istnieje potrzeba szukania nowych rozwiązań technicznych i taktycznych w celu optymalizacji procedur prowadzących do bardziej efektywnych działań służb przy tego rodzaju zdarzeniach.
Źródło:
Safety and Fire Technology; 2021, 58, 2; 38--57
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gaszenie pożarów we Wrocławiu według Porządków Ogniowych z XVI wieku
Extinguishing fires in Wrocław according to the Fire Orders of the 16th Century
Autorzy:
Ulicki, Bogusław
Powiązania:
https://bibliotekanauki.pl/articles/2189388.pdf
Data publikacji:
2022
Wydawca:
Krakowska Akademia im. Andrzeja Frycza Modrzewskiego
Tematy:
Wrocław
pożar
przepisy przeciwpożarowe
Porządki Ogniowe
Feuer (Fewer) Ordnung
Wrocław (Wroclaw)
fire
fire regulations
Fire Orders
Opis:
Porządek Ogniowy był szczegółowym przepisem porządkowym, regulującym zasady zapobiegania pożarom i ich gaszenia. Prezentowane opracowanie jest pierwszą obszerną analizą wrocławskich porządków ogniowych z lat 1574 i 1586. Autorzy niemieckojęzycznych opracowań historycznych z XIX w. i początku XX w. powoływali się na te przepisy w sposób uniemożliwiający faktyczne poznanie zasad walki z pożarami we Wrocławiu pod koniec XVI stulecia. Celem opracowania jest prezentacja najważniejszych ustaleń rady miejskiej Wrocławia dotyczących gaszenia pożarów i wykazanie zmian, które w nich zaszły w okresie dwunastu lat.
The Fire Order was a detailed ordinance regulating the principles of fire prevention and extinguishing. The presented study is the first comprehensive analysis of the Wrocław fire orders from the years 1574 and 1586. The authors of historical studies in German from the 19th and early 20th centuries referred to these regulations in a way that made it impossible to actually learn the rules of fighting fires in Wrocław at the end of the 16th century. The aim of the study is to present the most important findings of the Wrocław city council regarding firefighting and to show the changes that have taken place in them over the period of twelve years.
Źródło:
Studia z Dziejów Państwa i Prawa Polskiego; 2022, XXV, 25; 247-274
1733-0335
Pojawia się w:
Studia z Dziejów Państwa i Prawa Polskiego
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Postęp w technice gaszenia pożarów lasów
Advances in forest fires extinguishing techniques
Autorzy:
Karpowicz, M.
Gniazdowska, J.
Powiązania:
https://bibliotekanauki.pl/articles/791545.pdf
Data publikacji:
2016
Wydawca:
Wyższa Szkoła Zarządzania Środowiskiem w Tucholi
Tematy:
lasy
pozary lasow
gaszenie pozarow
postep techniczny
srodki gasnicze
zwilzacze
zageszczacze
sprzet gasniczy
fire
forest fire
extinguishing technique
extinguishing agent
wetting agent
thickener
fire-fighting equipment
Źródło:
Zarządzanie Ochroną Przyrody w Lasach; 2016, 10
2081-1438
2391-4106
Pojawia się w:
Zarządzanie Ochroną Przyrody w Lasach
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Gaszenie płomienia dyfuzyjnego przy pomocy fal akustycznych
Extinguishing a diffusion flame with the aid of acoustic waves
Autorzy:
Radomiak, H.
Mazur, M.
Zajemska, M.
Musiał, D.
Powiązania:
https://bibliotekanauki.pl/articles/973263.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
pożar
gaszenie płomienia
płomień dyfuzyjny
fala akustyczna
fire
extinguishing a flame
diffusion flame
acoustic wave
Opis:
Cel: W artykule przedstawiono możliwości wygaszania płomienia dyfuzyjnego za pomocą fal akustycznych. Wyznaczono krytyczną wartość częstotliwości oraz graniczną moc akustyczną, przy których zachodzi zjawisko wygaszenia płomienia. Metody: Na potrzeby realizacji zamierzonego celu niezbędne było skonstruowanie stanowiska umożliwiającego generowanie fal akustycznych w kierunku palnika. Stanowisko wyposażono w generator częstotliwości oraz wzmacniacz sygnału, głośnik o niskim paśmie przewodzenia, falowód, a także mierniki: napięcia, natężenia i częstotliwości. Pomiaru ciśnienia akustycznego w miejscu usytuowania płomienia dokonano za pomocą sondy Culite. Sonda jest skonstruowana na zasadzie mikrofonu z bardzo czułą membraną, elektrodą oraz kondensatorem. Zmiana ciśnienia w ośrodku powoduje minimalne przesunięcie membrany, co w konsekwencji powoduje zmiany w poziomie naładowania kondensatora. Poziom ten jest rejestrowany jako zmiana napięcia przepływającego przez układ. Wartości tego napięcia obserwuje się na ekranie systemu pomiarowego, co pozwala na przeliczenie ich na wartości ciśnienia, uwzględniając zakres pracy systemu pomiarowego. Ponadto wykonano wizualizację przebiegu procesu wygaszania płomienia za pomocą aparatu smugowego. Jest to idealna metoda graficznego dokumentowania wyników badań prowadzonych nad procesami spalania, gdzie niedostateczne oświetlenie wyciemnionego otoczenia nie pozwala na prawidłowe zobrazowanie tradycyjnymi metodami, zaś przy otoczeniu oświetlonym zachodzi nieoddanie całej struktury płomienia na zdjęciu, wywołane mocnym światłem emitowanym przez płomień. Wyniki: Przeprowadzone badania dowiodły, że dla danej wartości mocy cieplnej płomienia możliwe jest jego wygaszenie za pomocą szerokiego spektrum częstotliwości krytycznej (35 ÷ 155 Hz) oraz poziomu mocy granicznej poniżej 30 W. Zdolność gaśniczą oszacowano, wyznaczając współczynnik skuteczności gaszenia płomienia – dla wartości 35 ÷ 45 Hz mieściła się ona w przedziale od 35 do 155 Hz. Ponadto wyznaczono graniczną wartość ciśnienia akustycznego (zakres 45 ÷ 55 Pa), poniżej której zjawisko wygaszania płomienia było praktycznie niezauważalne. Wnioski: Przedstawiona metoda gaszenia płomienia umożliwia, poprzez zadziałanie falą akustyczną o odpowiedniej częstotliwości, całkowite wygaszenie płomienia. Fakt ten potwierdzają uzyskane w ramach eksperymentów wyniki, jak również przeprowadzona wizualizacja za pomocą aparatu smugowego.
Aim: The paper presents the feasibility of extinguishing a diffusion flame with the aid of acoustic waves. The study includes an assignment of critical frequency values and the acoustic force limit, the point at which a flame is extinguished. Methods: In order to achieve the desired aim, it was necessary to construct a test stand, to facilitate the generation of acoustic waves in the direction of a burner. The experimental stand was equipped with a frequency generator and amplifier, speaker with a low frequency band, waveguide and voltage strength and frequency meters. Measurement of sound pressure at the flame location was performed using a Culite probe. The probe was constructed on the principle of a microphone, using a very sensitive membrane, electrode and capacitor. Changing the pressure within the probe resulted in a minimal displacement of the membrane, which in turn caused changes to the charge level of the capacitor. This level was recorded as a change in the voltage flowing through the system. The voltage value was revealed on the screen of the measuring device, which allowed for the calculation of pressure values, taking into account the operating range of the measuring device. Additionally, extinguishing of the flame was observed visually with the aid of Schlieren imagery apparatus. This is considered to be an ideal method for graphical recording of research results associated with the combustion processes where insufficient lighting of a dim environment does not allow for proper imaging, using traditional methods. Whereas, in ambient lit conditions it is not possible to reveal the entire structure of the flame because of strong light emitted by the flame. Results: Studies reveal that for a given value of flame thermal power it is possible to extinguish a flame with the use of a wide spectrum of critical frequency (35 ÷ 155 Hz) and force limit level below 30 W. Extinguishing ability was estimated by assigning a flame extinguishing effectiveness ratio; for the value of 35 ÷ 45 Hz it was within the range between 35 to 155 Hz. Additionally, the sound pressure level limit value (range of 45 ÷ 55 Pa) was assigned, below which the flame extinguishing activity was virtually unnoticeable. Conclusions: The described flame extinguishing technique allows for the total extinguishing of flames with the aid of generated sound waves at an appropriate frequency. This is confirmed by results from research experiments and visual observation, using Schlieren imagery apparatus.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 4; 29-38
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies