Wyświetlanie 1-11 z 11
Tytuł:
Comparison of instantaneous fetal heart rate extracted from abdominal and direct fetal electrocardiograms
Autorzy:
Matonia, A.
Kupka, T.
Jezewski, J.
Momot, A.
Jeżewski, M.
Bernys, M.
Powiązania:
https://bibliotekanauki.pl/articles/333262.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia płodu
tętno płodu
fetal monitoring
fetal electrocardiography
fetal heart rate
Opis:
This work is an attempt to assess the reliability of indirect abdominal electrocardiography as an alternative technique of fetal monitoring. As a reference signal we used the simultaneously acquired direct fetal electrocardiogram. Each recording consisted of four signals acquired from maternal abdomen and the reference signal acquired directly from fetal head. The first stage of our study concerned the signal loss episodes. In order to reduce the influence of incorrectly detected R-waves, some certain validation rules were applied. In the second stage, the corresponding intervals determined on basis of both acquisition methods were matched and the accuracy of fetal heart rate measurement was evaluated. Although the accuracy of abdominal electrocardiography turned out to be slightly lower than reported for ultrasound method, it still has some unique features deciding of its prevalence in a certain circumstances.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 19; 101-107
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized fetal monitoring based on bioelectric signals from maternal abdomen
Autorzy:
Matonia, A.
Jeżewski, J.
Gacek, A.
Kupka, T.
Horoba, K.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/333805.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia
tętno płodu
fetal monitoring
fetal abdominal
electrocardiography
fetal heart rate
Opis:
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT37-47
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving the periodicity measurement in fetal heart activity signal
Autorzy:
Roj, D.
Wróbel, J.
Horoba, K.
Przybyła, T.
Kupka, T.
Powiązania:
https://bibliotekanauki.pl/articles/332933.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
USG metodą Dopplera
fetal monitoring
fetal heart rate
ultrasound Doppler
Opis:
In this paper we discussed the influence of preliminary processing of the ultrasound Doppler signal on accuracy of the fetal heart rate estimation as well as on reliability of the FHR instantaneous variability assessment. We attempted to develop an optimal processing channel of US Doppler signal in order to measure the periodicity of fetal heart activity with accuracy as close as possible to that ensured by FECG. The FHR values determined from the US signal were compared to the reference data obtained from direct FECG. In a final evaluation we used the parameters describing the FHR variability as the clinically important signal features being the most sensitive to any periodicity inaccuracy. The results proved that an application of proposed algorithms improves the accuracy of interval measurements and FHR instantaneous variability assessment in relation to the new-generation fetal monitors.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 19-26
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of predictive capabilities of quantitative cardiotocographic signal features
Autorzy:
Czabański, R.
Jeżewski, M.
Roj, D.
Szaszkowski, Z.
Kupka, T.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/332937.pdf
Data publikacji:
2010
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
klasyfikacja sygnału
fetal monitoring
fetal heart rate
signal classification
ROC analysis
Opis:
Cardiotocography (CTG) is the main method of assessment of the fetal state during pregnancy and labour used in clinical practice. It is based on quantitative analysis of fetal heart rate, fetal movements and uterine contractions signals. The evaluation of the CTG signals can be made using criteria recommended by International Federation of Obstetrics and Gynecology. Nevertheless, the diagnosis verification is possible only after the delivery on the basis of newborn assessment. In the proposed work we evaluated the capacity of quantitative analysis of CTG traces in predicting fetal outcome. The relationship between CTG signal features and attributes of fetal outcome was assessed on the basis of ROC curves analysis. The obtained results indicate the adequate predictive capabilities of the selected CTG features especially for fetal outcome assessed with Apgar score and suggest the necessity of applying the criteria for the CTG traces evaluation that are related to the gestational age. Our study also shows the value of the CTG monitoring as a screening procedure providing appropriate confirmation of fetal wellbeing.
Źródło:
Journal of Medical Informatics & Technologies; 2010, 16; 11-17
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuzzy system for evaluation of fetal heart rate signals using FIGO criteria
Autorzy:
Czabański, R.
Jeżewski, M.
Wróbel, J.
Jeżewski, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333142.pdf
Data publikacji:
2009
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring płodu
tętno płodu
kryteria FIGO
fetal monitoring
fetal heart rate
signal classification
fuzzy systems
Opis:
Cardiotocography is a biophysical method of fetal monitoring during pregnancy and labour. It is mainly based on recording and analysis of fetal heart activity. The computerized fetal monitoring systems provide the quantitative description of the recorded signals but the effective methods supporting the conclusion generation are still needed. The evaluation of the signal can be made using criteria recommended by FIGO. Nevertheless, the quantitative description of the traces is inconsistent with qualitative nature of the obstetric knowledge. Therefore, we applied the fuzzy system based on Takagi-Sugeno-Kang model to evaluate and classify signals. FIGO guidelines were used for developing a set of fuzzy conditional rules defining the system performance. The proposed system was evaluated using data collected with computerized fetal surveillance system – MONAKO. The classification results confirm the improvement of the fetal state evaluation quality while using the proposed fuzzy system support.
Źródło:
Journal of Medical Informatics & Technologies; 2009, 13; 189-194
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Inconsistency in evaluation of clinical patterns in fetal heart rate waveforms
Autorzy:
Jeżewski, J.
Horoba, K.
Wróbel, J.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333801.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
przyspieszanie / zwalnianie
fetal monitoring
fetal heart rate
acceleration/deceleration
expert inconsistency
Opis:
Acceleration and deceleration patterns in fetal heart rate (FHR) are widely used as an assessment of fetal condition. The basis for both visual and automated quantitative analysis is correctly determined fetal heart rate baseline. There are many methods for automated fetal heart rate baseline estimation. Since there are no definitive criteria or "gold standard" to evaluate algorithms for baseline determination, a clinical expert could be considered as a reference. Taking into account that not the shape of baseline itself but the results of quantitative analysis obtained using this baseline are important, we stated that such evaluation should be done only on the basis of comparison of effects - the recognized accelerations and decelerations. However, the first step for such comparison is to check how well expert meets established FIGO definition of accelerations and decelerations patterns in FHR trace. The paper presents a method for evaluation of expert's interpretation of these definitions. Two indices describing the inconsistency among fetal monitoring system and experts have been defined. The results obtained indicate the essential differences in procedure of accelerations/decelerations recognition by the computerized system and human expert.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT27-35
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coincidence of maternal and fetal QRS complexes in view of fetal heart rate determination
Autorzy:
Kupka, T.
Jeżewski, J.
Matonia, A.
Wróbel, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333792.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
brzuszne EKG płodu
monitorowanie płodu
tętno płodu
abdominal fetal electrocardiogram
fetal monitoring
fetal heart rate
Opis:
Indirect fetal electrocardiography is a developing diagnostic method in perinatal medicine. Signals of electrical activity being recorded from maternal abdomen surface contain more information than in till now used method of mechanical heart activity measurement based on ultrasound signals. The main problem relies on separation of basic useful component from a signal containing also dominant maternal electrocardiogram and muscles activity artifacts. The algorithms of maternal electrocardiogram suppression via subtraction are commonly used. Although regarding their complexity, these algorithms have limited applicability in systems for long-term monitoring of fetal heart activity. Other solution relies on simple blanking of maternal QRS complexes. However, in case of coincidence of fetal and maternal QRS complexes, this leads to partial loss of information about fetal heart rate variability. For evaluation of how often such coincidence of both complexes takes place, the algorithm has been developed which is described in this paper.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT49-55
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Fuzzy prediction of fetal acidemia
Autorzy:
Czabański, R.
Roj, D.
Jeżewski, J.
Horoba, K.
Jeżewski, M.
Powiązania:
https://bibliotekanauki.pl/articles/333483.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
klasyfikacja sygnału
systemy rozmyte
fetal monitoring
fetal heart rate
signal classification
fuzzy systems
Opis:
Cardiotocography is the primary method for biophysical assessment of a fetal state. It is based mainly on the recording and analysis of fetal heart rate signal (FHR). Computer systems for fetal monitoring provide a quantitative description of FHR signals, however the effective methods for their qualitative assessment are still needed. The measurements of hydronium ions concentration (pH) in newborn cord blood is considered as the objective indicator of the fetal state. Improper pH level is a symptom of acidemia being the result of fetal hypoxia. The paper proposes a twostep analysis of signals allowing for effective prediction of the acidemia risk. The first step consists in the fuzzy classification of FHR signals. The task of fuzzy inference is to indicate signals that according to the FIGO guidelines represent the fetal wellbeing. These recordings are eliminated from the further classification with Lagrangian Support Vector Machines. The proposed procedure was evaluated using data collected with computerized fetal surveillance system. The classification results confirmed the high quality of the proposed fuzzy method of fetal state evaluation.
Źródło:
Journal of Medical Informatics & Technologies; 2011, 17; 81-87
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The influence of window size of autocorrelation function on fetal heart rate variability measurement using the Doppler ultrasound signal
Autorzy:
Roj, D.
Fuchs, T.
Przybyła, T.
Jeżewski, M.
Matonia, A.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333477.pdf
Data publikacji:
2008
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitoring płodu
tętno płodu
USG Dopplera
funkcja autokorelacji
fetal monitoring
fetal heart rate
Doppler ultrasound
autocorrelation function
Opis:
Commonly used noninvasive fetal monitoring is based on fetal heart rate (FHR) variability analysis of the Doppler ultrasound signal coming from the mechanical activity of the fetal heart. Estimation of periodicity of acquired signals using the autocorrelation technique is very important. The determination of cardiac intervals using the Doppler signal is more difficult than in electrocardiography, where the R-waves are evident. We investigated the influence of the autocorrelation window size on the FHR variability analysis. The indices describing the FHR variability calculated for signals obtained using two different autocorrelation techniques with various window lengths were compared with the reference ones obtained from fetal electrocardiogram. The optimal window was a compromise between artifacts resistance and the averaging level of instantaneous variability.
Źródło:
Journal of Medical Informatics & Technologies; 2008, 12; 111-116
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A routing protocol for wireless network of bedside monitors in fetal surveillance system
Autorzy:
Seredynski, R.
Horoba, K.
Roj, D.
Bernys, M.
Przybyla, T.
Jezewski, J.
Powiązania:
https://bibliotekanauki.pl/articles/333626.pdf
Data publikacji:
2012
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
sieci bezprzewodowe
protokoły rutowania
symulacja
fetal monitoring
fetal heart rate
wireless networks
routing protocol
simulation
Opis:
The paper presents the methodology of wireless network design, developed according to the requirements originating from existing wired fetal surveillance systems. The proposed network structure is based on popular radio frequency modules, operating in 433/866MHz band. The described solution is a simple and cost effective alternative to the wired networks, and it will vastly increase the mobility of fetal monitors. The authors also describe software tools which were designed for this purpose and the results of simulations performed on their basis.
Źródło:
Journal of Medical Informatics & Technologies; 2012, 21; 27-33
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of fetal electrocardiogram and systolic time intervals
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Wróbel, J.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334019.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
wybrany termin cyklu sercowego
EKG płodu
tętno płodu
fetal monitoring
cardiac cycle timing
fetal electrocardiography
fetal heart rate
Opis:
Cardiotocography as a simultaneous recording of fetal heart rate (FHR) and uterine contraction activity is a basic method of evaluation of fetal condition. Correct variability of the fetal heart rate is an indirect sign of adequate oxygenation of a fetus. Unfortunately, the reverse case is not always true, signs suggesting pathological changes can also appear in recording when the fetal is not at risk. The cardiotocography shall then be recognized as a more screening than diagnostic method. It will be interesting to develop a non-invasive method being complementary to routine cardiotocography. This method should allow the adequate prediction of a bad neonatal outcome when the test is abnormal. The paper shows the system that makes possible cardiotocograms analysis in parallel with the assessment of additional parameters determined from comparison of mechanical and electrical fetal heart activity signals. The studies are aimed at development of set of parameters that are high correlated with clinical outcome.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT27-34
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies