Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Wrobel, A" wg kryterium: Autor


Wyświetlanie 1-7 z 7
Tytuł:
Inconsistency in evaluation of clinical patterns in fetal heart rate waveforms
Autorzy:
Jeżewski, J.
Horoba, K.
Wróbel, J.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333801.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
tętno płodu
przyspieszanie / zwalnianie
fetal monitoring
fetal heart rate
acceleration/deceleration
expert inconsistency
Opis:
Acceleration and deceleration patterns in fetal heart rate (FHR) are widely used as an assessment of fetal condition. The basis for both visual and automated quantitative analysis is correctly determined fetal heart rate baseline. There are many methods for automated fetal heart rate baseline estimation. Since there are no definitive criteria or "gold standard" to evaluate algorithms for baseline determination, a clinical expert could be considered as a reference. Taking into account that not the shape of baseline itself but the results of quantitative analysis obtained using this baseline are important, we stated that such evaluation should be done only on the basis of comparison of effects - the recognized accelerations and decelerations. However, the first step for such comparison is to check how well expert meets established FIGO definition of accelerations and decelerations patterns in FHR trace. The paper presents a method for evaluation of expert's interpretation of these definitions. Two indices describing the inconsistency among fetal monitoring system and experts have been defined. The results obtained indicate the essential differences in procedure of accelerations/decelerations recognition by the computerized system and human expert.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT27-35
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Computerized fetal monitoring based on bioelectric signals from maternal abdomen
Autorzy:
Matonia, A.
Jeżewski, J.
Gacek, A.
Kupka, T.
Horoba, K.
Wróbel, J.
Powiązania:
https://bibliotekanauki.pl/articles/333805.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
elektrokardiografia
tętno płodu
fetal monitoring
fetal abdominal
electrocardiography
fetal heart rate
Opis:
The paper presents an instrumentation set for effective diagnostics of early symptoms of fetal distress in high-risk pregnancy based on bioelectric signals recording. The representative database of records has been established that enabled the complex analysis of signals recorded on a surface of maternal abdomen. As an outcome, the effective algorithms have been developed for processing both the fetal electrocardiogram and the signal of electrical activity of a uterine muscle. This allowed the development of unique diagnostic system based on external biosignal measurement module connected to the standard personal computer. In this system, like in a classical fetal monitor, the fetal heart rate (FHR) signal together with contraction activity signal of uterine muscle and fetal movement become an essential source of information on fetal condition. In addition, there is a possibility for spectral analysis of FHR signal as well as a morphology assessment of fetal ECG signal.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT37-47
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Coincidence of maternal and fetal QRS complexes in view of fetal heart rate determination
Autorzy:
Kupka, T.
Jeżewski, J.
Matonia, A.
Wróbel, J.
Horoba, K.
Powiązania:
https://bibliotekanauki.pl/articles/333792.pdf
Data publikacji:
2002
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
brzuszne EKG płodu
monitorowanie płodu
tętno płodu
abdominal fetal electrocardiogram
fetal monitoring
fetal heart rate
Opis:
Indirect fetal electrocardiography is a developing diagnostic method in perinatal medicine. Signals of electrical activity being recorded from maternal abdomen surface contain more information than in till now used method of mechanical heart activity measurement based on ultrasound signals. The main problem relies on separation of basic useful component from a signal containing also dominant maternal electrocardiogram and muscles activity artifacts. The algorithms of maternal electrocardiogram suppression via subtraction are commonly used. Although regarding their complexity, these algorithms have limited applicability in systems for long-term monitoring of fetal heart activity. Other solution relies on simple blanking of maternal QRS complexes. However, in case of coincidence of fetal and maternal QRS complexes, this leads to partial loss of information about fetal heart rate variability. For evaluation of how often such coincidence of both complexes takes place, the algorithm has been developed which is described in this paper.
Źródło:
Journal of Medical Informatics & Technologies; 2002, 4; MT49-55
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Smart selection of signal analysis algorithms for telecare of high-risk pregnancy
Autorzy:
Wróbel, J.
Matonia, A.
Horoba, K.
Jeżewski, J.
Czabański, R.
Pawlak, A.
Porwik, P.
Powiązania:
https://bibliotekanauki.pl/articles/333593.pdf
Data publikacji:
2014
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal monitoring
abdominal fetal electrocardiogram
smart signal processing
telemedicine
monitorowanie płodu
brzuszne EKG płodu
inteligentne przetwarzanie sygnałów
telemedycyna
Opis:
Telemedical system for fetal home monitoring with smart selection of signal analysis algorithms is presented in this paper. Fetal monitoring signals are provided by a mobile instrumentation consisting of bioelectrical signal recorder and tablet PC which retrieves and processes the data as well as provides wireless data transmission based on Internet. The fetal surveillance system enables analysis, dynamic presentation and archiving of acquired signals and medical data. Novelty of the proposed approach relies on smart fitting of the algorithms for analysis of the abdominal signals in mobile instrumentation, as well as on controlling of the fetal monitoring session from the surveillance center. These actions are performed automatically through continuous analyzing of the signal quality and the reliability of the quantitative parameters determined for the acquired signals. Using that approach the amount and content of data transmitted through remote channels to the surveillance center can be controlled to ensure the most reliable assessment of the fetal well-being.
Źródło:
Journal of Medical Informatics & Technologies; 2014, 23; 27-33
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A novel approach to comparison of the fetal heart rate baseline estimation algorithms
Autorzy:
Jezewski, J.
Horoba, K.
Roj, D.
Wrobel, J.
Kupka, T.
Matonia, A.
Powiązania:
https://bibliotekanauki.pl/articles/332862.pdf
Data publikacji:
2015
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
fetal monitoring
baseline estimation
acceleration
deceleration
monitorowanie płodu
estymacja
przyspieszanie
zwalnianie
Opis:
A number of algorithms for estimating the so called fetal heart rate baseline was proposed so far. However, there is no reference pattern enabling their objective evaluation, and thus no methodology of comparing the competing algorithms still exists. In this paper we propose a method for evaluation of automatically determined baseline in reference to a group of experts, basing on ten separate groups of signals comprising typical patterns observed in the fetal heart rate. For the purpose of quantitative assessment of the estimated baseline a new synthetic inconsistency coefficient is presented. The proposed methodology was applied to evaluate ten well-known algorithms. We believe that the method will be a valuable tool for assessment of the existing algorithms, as well as for developing new ones.
Źródło:
Journal of Medical Informatics & Technologies; 2015, 24; 231-238
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Combined analysis of fetal electrocardiogram and systolic time intervals
Autorzy:
Matonia, A.
Jeżewski, J.
Kupka, T.
Horoba, K.
Wróbel, J.
Widera, M.
Powiązania:
https://bibliotekanauki.pl/articles/334019.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
monitorowanie płodu
wybrany termin cyklu sercowego
EKG płodu
tętno płodu
fetal monitoring
cardiac cycle timing
fetal electrocardiography
fetal heart rate
Opis:
Cardiotocography as a simultaneous recording of fetal heart rate (FHR) and uterine contraction activity is a basic method of evaluation of fetal condition. Correct variability of the fetal heart rate is an indirect sign of adequate oxygenation of a fetus. Unfortunately, the reverse case is not always true, signs suggesting pathological changes can also appear in recording when the fetal is not at risk. The cardiotocography shall then be recognized as a more screening than diagnostic method. It will be interesting to develop a non-invasive method being complementary to routine cardiotocography. This method should allow the adequate prediction of a bad neonatal outcome when the test is abnormal. The paper shows the system that makes possible cardiotocograms analysis in parallel with the assessment of additional parameters determined from comparison of mechanical and electrical fetal heart activity signals. The studies are aimed at development of set of parameters that are high correlated with clinical outcome.
Źródło:
Journal of Medical Informatics & Technologies; 2003, 6; IT27-34
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Data stream processing in fetal monitoring system: I. algebra and query language
Autorzy:
Widera, M.
Jeżewski, J.
Winiarczyk, R.
Wróbel, J.
Horoba, K.
Gacek, A.
Powiązania:
https://bibliotekanauki.pl/articles/333189.pdf
Data publikacji:
2003
Wydawca:
Uniwersytet Śląski. Wydział Informatyki i Nauki o Materiałach. Instytut Informatyki. Zakład Systemów Komputerowych
Tematy:
język zapytań
przetwarzanie strumienia danych
system zarządzania bazami danych
monitorowanie płodu
query language
data stream processing
database management system
fetal monitoring
Opis:
The paper presents the algebra and declarative query language developed for fetal monitoring system MONAKO. At present, the system architecture is centralised. Recording, analyzing and visualization of data are carrying out in the central unit. Therefore, the system cannot scale in a simple manner. Presented solution enables to define query based on data streams that makes the updated answers currently available. Applying database management system that carries out its tasks based on presented assumptions enables the construction of monitoring system of distributed architecture
Źródło:
Journal of Medical Informatics & Technologies; 2003, 5; MI83-90
1642-6037
Pojawia się w:
Journal of Medical Informatics & Technologies
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies