Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power quality energy" wg kryterium: Temat


Tytuł:
Statistical analysis and dimensioning of a wind farm energy storage system
Autorzy:
Waśkowicz, B.
Powiązania:
https://bibliotekanauki.pl/articles/141698.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy storage
power quality
renewable energy
wind power
Opis:
The growth in renewable power generation and more strict local regulations regarding power quality indices will make it necessary to use energy storage systems with renewable power plants in the near future. The capacity of storage systems can be determined using different methods most of which can be divided into either deterministic or stochastic. Deterministic methods are often complicated with numerous parameters and complex models for long term prediction often incorporating meteorological data. Stochastic methods use statistics for ESS (Energy Storage System) sizing, which is somewhat intuitive for dealing with the random element of wind speed variation. The proposed method in this paper performs stabilization of output power at one minute intervals to reduce the negative influence of the wind farm on the power grid in order to meet local regulations. This paper shows the process of sizing the ESS for two selected wind farms, based on their levels of variation in generated power and also, for each, how the negative influences on the power grid in the form of voltage variation and a shortterm flicker factor are decreased.
Źródło:
Archives of Electrical Engineering; 2017, 66, 2; 265-277
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Review of voltage fluctuation measures in power quality analyzers
Autorzy:
Wiczyński, G.
Powiązania:
https://bibliotekanauki.pl/articles/97690.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electrical energy
voltage
power quality
Opis:
Similarly to a number of other quantities, those describing voltage variation make it possible to provide a complete assessment of the quality of electrical energy. Voltage variation may be described by measures used to assess the obnoxiousness of voltage fluctuations or measures that help indicate the source of fluctuations. The paper provides a comparison of the three most popular measures: the Umax maximum and Umin minimum rms voltage values, the Pst short-term flicker indicator, and voltage fluctuation indicators. The part that specifies the particular measures (including an additional description of the ∆V10 indicator) also contains their short descriptions. The main part of the dissertation describes the dependence of the voltage fluctuation measures on the frequency of the fm amplitude and frequency modulating signal. Observations drawn allow to specify the diagnostic capabilities of particular measures. Due to the complexity of voltage fluctuation measures’ studies the paper deals with only a certain aspect of it and should be concerned as a step to understanding the idea of voltage fluctuation measures.
Źródło:
Computer Applications in Electrical Engineering; 2012, 10; 308-316
1508-4248
Pojawia się w:
Computer Applications in Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unified power quality conditioner in a grid-connected photovoltaic system
Autorzy:
Cavalcanti, M. C.
Azevedo, G. M.
Amaral, B. A.
Neves, F. A.
Powiązania:
https://bibliotekanauki.pl/articles/262717.pdf
Data publikacji:
2006
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
control systems
converters
energy conversion
photovoltaic power systems
power quality
solar energy
Opis:
This paper presents a system that provides photovoltaic generation as well as the functions of a unified power quality conditioner. The system can be controlled for current harmonics and reactive power compensation simultaneously by using a converter operating as active shunt filter. The other converter is used as active series filter and it compensates voltage harmonics or voltage sags and swells. Using only an inverter in photovoltaic energy conversion process, the system presents increased efficiency when compared to the conventional systems. The synchronous reference frame method is used to control the three-phase converters. Simulation results demonstrate the good performance of the proposed configuration. Experimental results corresponding to the operation of the series filter as voltage sag compensator are presented.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2006, 12, 2; 59-69
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Voltage Flicker Mitigation Using STATCOM and BESS
Autorzy:
Virulkar, V. B.
Aware, M. V.
Powiązania:
https://bibliotekanauki.pl/articles/262608.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie
Tematy:
battery energy storage system
power quality
voltage flicker
SVC
STATCOM
Opis:
The Voltage flicker, a phenomenon of annoying light intensity fluctuation, caused by rapid change in industrial and domestic load such as Electric Arc Furnaces (EAF), rolling mills, welding equipments and pumps operating periodically has been a major concern for supply utilities, electricity regulatory agencies and customers. Static Voltage Compensators (SVC's) and Static Synchronous Compensators (STATCOM) have been able to solve the voltage flicker problem by rapidly controlling the reactive power. But, the control of active power along with reactive power control helps to mitigate the voltage flicker problem more effectively. In this paper, voltage flicker mitigation of EAF with STATCOM along with Battery Energy Storage System (BESS) is presented and performance results of the system using PSCAD/EMTDC software are analyzed.
Źródło:
Electrical Power Quality and Utilisation. Journal; 2009, 15, 1; 51-57
1896-4672
Pojawia się w:
Electrical Power Quality and Utilisation. Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Jakość energii elektrycznej w punkcie identyfikacji w systemie elektroenergetycznym
Quality of electrical energy in the identification point in the power system
Autorzy:
Cieślik, S.
Powiązania:
https://bibliotekanauki.pl/articles/266663.pdf
Data publikacji:
2016
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
miara jakości energii
poziom jakości energii
quality of electric energy
power quality
electric power system
Opis:
W artykule przedstawiono uzasadnienie i propozycję definicji jakości energii elektrycznej w punkcie identyfikacji w systemie elektroenergetycznym. Punktem wyjścia było założenie, że energia elektryczna jest towarem w systemie elektroenergetycznym. Podano również definicje pojęć ściśle związanych z jakością energii elektrycznej w tych systemach.
The paper presents the justification and proposal of a definition for quality of electrical energy in the point of identification in the power system. The starting point is the assumption that electrical energy is a commodity in the power system. A definition of terms closely related to the quality of electrical energy in these systems is also presented.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2016, 50; 11-14
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność energetyczna urządzeń oświetleniowych a jakość energii elektrycznej
Energy efficiency of lighting devices versus power quality
Autorzy:
Czapp, S.
Powiązania:
https://bibliotekanauki.pl/articles/268717.pdf
Data publikacji:
2012
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
oświetlenie elektryczne
efektywność energetyczna
jakość energii elektrycznej
electrical lighting
energy efficiency
power quality
Opis:
Energooszczędne urządzenia oświetleniowe od wielu lat są stosowane m.in. w gospodarstwach domowych, obiektach użyteczności publicznej, obiektach przemysłowych i oświetleniu ulicznym, a obowiązująca od 2011 r. Ustawa o efektywności energetycznej z pewnością ich stosowanie zintensyfikuje. Urządzenia te pobierają prąd odkształcony, a w niektórych przypadkach ? silnie odkształcony. Powoduje to różnorodne problemy instalacyjne. W pracy przeprowadzono analizę odkształcenia prądu pobieranego przez wybrane lampy i oceniono je z punktu widzenia wymagań odnośnie do jakości energii elektrycznej.
Energy efficient lighting is increasingly placed in residential, public and industrial indoors as well as in outdoor lighting. This process is assisted by Energy Efficiency Plan 2011 prepared by Euro Parliament. The load current of high efficient lamps usually is distorted and sometimes the distortion is remarkably high. This phenomenon can cause serious problems in the supply installation. This paper presents an analysis of current distortion in lamps circuits and evaluation of this distortion in terms of power quality standards.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2012, 31; 195-200
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lokalizacja źródeł zaburzeń napięcia w oparciu o zagregowane dane pomiarowe
Location of voltage disturbances sources based on aggregated measuring data
Autorzy:
Chmielowiec, Krzysztof
Wiczyński, Grzegorz
Firlit, Andrzej
Dutka, Mateusz
Barczentewicz, Szymon
Powiązania:
https://bibliotekanauki.pl/articles/268160.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
jakość energii elektrycznej
liczniki energii elektrycznej
zaburzenia napięcia
źródła zaburzeń
power quality
energy meters
power disturbances
disturbances sources
Opis:
W ostatnim czasie operatorzy elektroenergetycznych systemów dystrybucyjnych w Polsce zainstalowali w swoich sieciach kilkadziesiąt tysięcy bilansujących liczników energii elektrycznej wyposażonych, zgodnie z wymaganiami Urzędu Regulacji Energetyki, w funkcje pomiaru wskaźników jakości dostawy energii elektrycznej. Liczniki te, z racji swoich nowych funkcji pomiarowych oferują nowe możliwości oceny funkcjonowania oraz diagnostyki sieci dystrybucyjnych. Są też źródłem znaczącego wolumenu danych pomiarowych. Artykuł prezentuje możliwości wykorzystania zagregowanych wartości 10-minutowych pomiaru jakości energii elektrycznej, pochodzących z rozproszonych przyrządów pomiarowych (liczników i analizatorów) energii elektrycznej, w celu lokalizacji dominujących źródeł zaburzeń w elektroenergetycznej sieci dystrybucyjnej.
Recently, electricity distribution system operators in Poland have installed tens of thousands of balancing electricity meters, in accordance with the requirements of the Energy Regulatory Office, with the function of measuring the quality of electricity supply indicators. These meters, due to their new power quality measuring functions and significant volume, offer new possibilities in the assessment of functioning and diagnostics of power distribution systems. The article presents the possibility of using aggregated 10-minute power quality measurement data from electricity from dispersed electricity meters to locate dominant sources of disturbances in the power distribution network.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 67; 53-56
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected aspects of wind and photovoltaic power plant operation and their cooperation
Autorzy:
Lange, Andrzej
Pasko, Marian
Grabowski, Dariusz
Powiązania:
https://bibliotekanauki.pl/articles/2086878.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
harmonic distortion
power quality
renewable energy sources
zniekształcenia harmoniczne
jakość energii
odnawialne źródła energii
Opis:
The connection of renewable energy sources with significant nominal power (in the order of MW) to the medium-voltage distribution grid affects the operating conditions of that grid. Due to the increasing number of installed renewable energy sources and the limited transmission capacity of medium-voltage networks, the cooperation of these energy sources is becoming increasingly important. This article presents the results of a six-year study on a 2 MW wind power plant and a 1 MW photovoltaic power plant in the province of Warmia and Mazury, which are located a few kilometers away from each other. In this study, active energy, currents, voltages as well as active, reactive, and apparent power and higher harmonics of currents and voltages were measured. The obtained results show the parameters determining the power quality at different load levels. Long-term analysis of the operation of these power plants in terms of the generated electricity andactive power transmitted to the power grid facilitated estimating the repeatability of active energy production and the active power generated in individual months of the year and times of day by a wind power plant and a photovoltaic power plant. It also allowed us to assess the options of cooperation between these energy sources. It is important, not only from a technical but also from an economic point of view, to determine the nominal power of individual power plants connected to the same connection point. Therefore, the cooperation of two such power plants with the same nominal power of 2 MW was analyzed and the economic losses caused by a reduction in electricity production resulting from connection capacity were estimated.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2021, 69, 6; e139793, 1--16
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimum tasks and solutions for energy transmission from the source to the receiver
Autorzy:
Siwczyński, M.
Hawron, K.
Powiązania:
https://bibliotekanauki.pl/articles/201042.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy sources
minimum principle
power quality
optimum task
źródła energii
zadanie optymalizacyjne
jakość mocy
Opis:
The article presents the minimum optimization tasks that streamline the operating conditions of real linear power sources. Square functions, depending on source current and source power losses within the common power balance condition, have been proposed as quality criteria. These problems have been solved using the exact and simplified approximate methods.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2018, 66, 5; 655-663
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of Proportional-Integral Controllers of Grid-Connected Wind Energy Conversion System Using Grey Wolf Optimizer Based on Artificial Neural Network for Power Quality Improvement
Autorzy:
Alremali, Fathi Abdulmajeed M.
Yaylacı, Ersagun Kürşat
Uluer, İhsan
Powiązania:
https://bibliotekanauki.pl/articles/2201727.pdf
Data publikacji:
2022
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
artificial neural network
grey wolf optimizer
PI controller
grid connection
power quality
wind energy
Opis:
This research presents a combination of artificial neural network (ANN) with the grey wolf optimizer (GWO) to improve the power quality of a grid-connected distributed power generation system (DPGS). To assess the effectiveness of the proposed algorithm, a grid-tied of small-scale wind energy conversion system (WECS) is chosen. The term power quality refers to voltage and frequency regulation, and limited harmonics. Power quality improvement is achieved through the cascaded control system's optimal tuning of three proportional-integral (PI) controllers of the grid-side inverter (GSI). However, because the DPGS model is computationally costly, the Artificial Neural Network (ANN) model is utilized as an alternative model for DPGS. Furthermore, the ANN model is employed in conjunction with the GWO to boost the optimization precision and minimize the execution time of GWO. The considered power system was repetitively simulated to obtain the input-output datasets, which validate and train the ANN model. According to the ANN model's performance evaluation, the correlation coefficient (R) is close to one, while the mean squared error (MSE) is near zero. These findings demonstrate the ANN model's great accuracy in approximating the DPGS model. Using MATLAB/Simulink, the system's performance is evaluated using the optimum values obtained using GWO-ANN for various wind speed profiles. It showed the suggested power quality method’s improved stability, convergence behavior, the effectiveness of the control mechanism, and the robustness of the proposed topology.
Źródło:
Advances in Science and Technology. Research Journal; 2022, 16, 3; 295--305
2299-8624
Pojawia się w:
Advances in Science and Technology. Research Journal
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wybrane problemy integracji rozproszonych źródeł energii z siecią dystrybucyjną
Selected problems of integration of distributed energy sources in electrical power network
Autorzy:
Wasiak, I.
Powiązania:
https://bibliotekanauki.pl/articles/267294.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
generacja rozproszona
odnawialne źródła energii
zasobniki energii
jakość zasilania
jakość energii
distributed generation
renewable energy sources
energy storage
power quality
Opis:
W artykule omówiono wybrane problemy integracji rozproszonych źródeł energii z siecią elektroenergetyczną. Zdefiniowano zdolność przyłączeniową sieci oraz omówiono sposób jej wyznaczania. Przedstawiono wpływ przyłączania źródeł na parametry jakości napięcia zasilającego. Omówiono rolę zasobników energii w procesie integracji źródeł.
In the paper some selected problems of the integration of distributed energy resources in distribution power networks are presented. The influence of energy sources on the network operation is discussed. Then, network hosting capacity is defined and illustrated for different evaluation indices. The impact of energy sources connection to the network is presented with focus on power quality issues including voltage level, voltage fluctuation, voltage harmonics and asymmetry. A formula for the network hosting capacity determination is derived as regards voltage changes after the source connection. Further, the way of evaluation of voltage fluctuation and resulting flicker phenomena as well as evaluation of voltage harmonics is discussed for wind farms. Finally, the role of energy storages in the process of distributed energy sources integration is discussed with special attention to ancillary services that can be performed by storage inverters. An example of simulation is shown to illustrate the ability of energy storage to control active power and stabilize the supplying voltage at the same time.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 45; 57-62
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy Saving LED and CFL Lamps - Rated vs. True Power and Current Consumption
Energooszczędne lampy LED i CFL - dane znamionowe a rzeczywista moc i pobór prądu
Autorzy:
Mikoś, Zbigniew
Jachimski, Marcin
Bień, Andrzej
Powiązania:
https://bibliotekanauki.pl/articles/275834.pdf
Data publikacji:
2020
Wydawca:
Sieć Badawcza Łukasiewicz - Przemysłowy Instytut Automatyki i Pomiarów
Tematy:
LED lamps
CFL lamps
power measurement
energy measurement
power quality
lampy LED
lampy CFL
pomiar mocy
pomiar energii
jakość energii
Opis:
There is a very high availability of energy-saving lamps for consumer use on the market. Manufacturers, wanting to reach the widest possible range of customers, present on the packaging various data that do not inform the user about the real energy properties of the lamp. The authors have measured the energy parameters of several randomly selected LED and CFL lamps available in commercial networks and compared the obtained results with the parameters declared by the manufacturers.
Na rynku można zauważyć bardzo dużą dostępność lamp energooszczędnych przeznaczonych do zastosowań konsumenckich. Producenci, chcąc dotrzeć do jak najszerszego kręgu odbiorców, prezentują na opakowaniach różne dane, które nie informują użytkownika o rzeczywistych własnościach energetycznych lampy. Autorzy wykonali pomiary parametrów energetycznych kilku, przypadkowo wybranych lamp LED oraz CFL dostępnych w sieciach handlowych i porównali otrzymane dane pomiarowe z parametrami deklarowanymi przez producentów.
Źródło:
Pomiary Automatyka Robotyka; 2020, 24, 2; 51-58
1427-9126
Pojawia się w:
Pomiary Automatyka Robotyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Robocza, odbita i szkodliwa moc czynna
Working, reflected and detrimental active power
Autorzy:
Czarnecki, L. S.
Powiązania:
https://bibliotekanauki.pl/articles/153084.pdf
Data publikacji:
2010
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
rozliczenia energetyczne
jakość energii
harmoniczne
asymetria
odbiorniki
energy accounts
power quality
harmonics
asymmetr
asymmetry
unbalanced loads
Opis:
Moc czynna odbiorników generujących harmoniczne prądu bądź zasilanych napięciem odkształconym lub niesymetrycznym nie jest synonimem mocy użytecznej. Ma ona składniki zarówno użyteczne jak i szkodliwe. Rozliczenia energetyczne uwzględniające użyteczność i szkodliwość składników mocy czynnej mogą tworzyć motywacje ekonomiczne dla poprawy jakości zasilania i jakości użytkowania energii elektrycznej.
The active power of harmonics generating loads or loads supplied with asymmetrical or distorted voltage is not a synonym to the useful power. It has both useful and detrimental components. Energy accounts that recognize the usefulness and harmfulness of these components could create economical incentives for both the supply quality and the loading quality improvement.
Źródło:
Pomiary Automatyka Kontrola; 2010, R. 56, nr 11, 11; 1256-1258
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Strategia sterowania mikrosystemem elektroenergetycznym niskiego napięcia zapewniająca jego elastyczną pracę w trybie połączenia z siecią zasilającą i w trybie wyspowym, przy wykorzystaniu zasobnika energii
A control strategy for flexible operation of lv microgrid in both grid- connected and islanded mode based on energy storage utilization
Autorzy:
Małaczek, Michał
Wasiak, Irena
Powiązania:
https://bibliotekanauki.pl/articles/267429.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
mikrosystemy elektroenergetyczne
sterowanie hierarchiczne
praca wyspowa
jakość zasilania
microgrid autonomous operation
microgrid hierarchical control
energy storage
power quality
Opis:
W artykule zaprezentowano strategię sterowania, która umożliwia pracę mikrosystemu elektroenergetycznego (MSE) niskiego napięcia w dwóch trybach: w połączeniu z siecią zasilającą oraz w trybie wyspowym. Rozpatrywany MSE zawiera sterowalne i niesterowalne źródła energii, zasobnik energii (ZE) oraz odbiory. Strategia sterowania jest hierarchiczna i bazuje na rozszerzeniu funkcjonalności zasobnika energii oraz implementacji centralnego regulatora (CR) zarządzającego pracą urządzeń sterowanych. Przedstawiono koncepcję sterowania ze szczególnym uwzględnieniem działania regulatora centralnego. Zaprezentowano model symulacyjny zbudowany w środowisku PSCAD/EMTDC do analizy proponowanego systemu sterowania i oceny pracy MSE. Przedstawiono i omówiono wyniki symulacji, które obrazują poprawność i efektywność zaproponowanej strategii sterowania.
In the paper, a hierarchical control strategy is presented allowing a low voltage microgrid (MG) to operate in both gridconnected and islanded mode. The considered MG consist of photovoltaic panels (PV), gas microturbine (MT), loads and energy storage (ES). The concept is based on enhancing the functionality of an ESS which is used for energy management in normal operating conditions of the network and a central controller for supervising the network operation in grid-connected and islanded modes. It has been assumed that the ESS serves as grid-forming unit, i.e. maintains the reference voltage and is responsible for short-term power balancing during islanded operation. Performance of the proposed strategy is presented as a reaction of the network on voltage dips, however the idea is applicable to any power quality (PQ) disturbance of unacceptable level occurring in the utility grid. For the considered network a simulation model has been developed using PSCAD/EMTDC platform. Simulation results are presented in the paper which illustrate the operation of the control system and show the microgrid behavior after transition from grid-connected to islanded operation and back.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 77-80
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Celowość stosowania analizy skupień do oceny zagadnień związanych z jakością energii elektrycznej w sieciach kopalnianych
The purpose of using the cluster analysis to evaluate the issues related to the quality of the electric power in the mining networks
Autorzy:
Jasiński, M.
Sikorski, T.
Powiązania:
https://bibliotekanauki.pl/articles/131375.pdf
Data publikacji:
2017
Wydawca:
Uczelnia Jana Wyżykowskiego
Tematy:
jakość energii elektrycznej
JEE
analiza skupień
długoterminowe dane jakości energii elektrycznej
zdarzenia napięciowe
zasilanie zakładów górniczych
generacja rozproszona
odnawialne źródła energii
power quality
cluster analysis
long term power quality data
voltage events
mining plant supply
distributed generation
renewable sources of energy
Opis:
Artykuł prezentuje możliwość zastosowania analizy skupień w analizie danych jakości energii elektrycznej. Pierwsza cześć opisuje ogólnie metody aglomeracji danych oraz wskazuje miejsce analizy skupień w eksploracji danych. Druga część wykazuje cechy analizy skupień sprzyjające zastosowaniu w analizie danych jakości energii elektrycznej. Cześć trzecia to analiza przypadku zastosowania analizy skupień do wyłonienia zdarzeń napięciowych na podstawie posiadanych danych z stacji elektroenergetycznej wybranego zakładu górniczego zlokalizowanego w Zagłębiu Miedziowym. W artykule wyłonienie zdarzeń napięciowych polega na przeprowadzeniu analizy skupień z zastosowaniem algorytmu K-średnich, czego dokonuje się, dobierając odległości Czebyszewa przy zadanej liczby skupień.
The article states that cluster analysis may be used to power quality analysis. First part presents generally the data mining and indicate the placement of cluster analysis in data mining techniques. Second part shows the property indicates of cluster analysis, which indicate the possibility of using it in power quality data analysis. Third part is a case study how to indicates the voltage events by clustering based on power quality data of mining plant in Zagłębie Miedziowe. The indication is made by using K-mean algorithm - Chebyshev distance with the selected number of cluster.
Źródło:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych; 2017, 6; 103-110
2543-6740
Pojawia się w:
Zeszyty Naukowe Uczelni Jana Wyżykowskiego. Studia z Nauk Technicznych
Dostawca treści:
Biblioteka Nauki
Artykuł

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies