Tytuł:
Analysis of the use of waste heat from a glass melting furnace for electricity production in the organic Rankine cycle system
Autorzy:
Musiał, Arkadiusz Mateusz
Antczak, Łukasz
Jędrzejewski, Łukasz
Klonowicz, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/1845495.pdf
Data publikacji:
2021
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
energy efficiency
distributed generation
organic rankine cycle
ORC
industrial waste heat
Opis:
In most production plants, waste heat is usually discharged into the environment, contributing to a reduction in the energy efficiency of industrial processes. This is often due to the low thermal parameters of the carriers in which this energy is contained, such as oils, water, exhaust gases or other post-process gases, which means that their use for electricity production in a conventional Rankine cycle may prove to be economically unprofitable. One of the technologies enabling the use of lowand medium-temperature waste heat carriers is the organic Rankine cycle (ORC) technology. The paper present results of calculations performed to evaluate potential electricity production in ORC using waste heat from a natural gas-fired glass melting furnace. The analysis was carried out assuming the use of a single-stage axial turbine, whose efficiency was estimated using correlations available in the literature. The calculations were carried out for three working fluids, namely hexamethyldisiloxane, dimethyl carbonate, and toluene for two scenarios, i.e. ORC system dedicated only to electricity production and ORC system working in cogeneration mode, where heat is obtain from cooling the condenser. In each of the considered cases, the ORC system achieves the net power output exceeding 300 kW (309 kW for megawatts in the cogenerative mode to 367 kW for toluene in the non-cogenerative mode), with an estimated turbine efficiency above 80%, in range of 80,75 to 83,78%. The efficiency of the ORC system, depending on the used working fluid and the adopted scenario, is in the range from 14.85 to 16.68%, achieving higher efficiency for the non-cogenerative work scenario.
Źródło:
Archives of Thermodynamics; 2021, 42, 1; 15-33
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The use of adsorption chillers for waste heat recovery
Wykorzystanie chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego
Autorzy:
Kuchmacz, Jan
Bieniek, Artur
Mika, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/283345.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Instytut Gospodarki Surowcami Mineralnymi i Energią PAN
Tematy:
waste heat
heat recovery
energy efficiency
adsorption refrigerators
ciepło odpadowe
odzysk ciepła
efektywność energetyczna
chłodziarka adsorpcyjna
Opis:
The purpose of this article was to discuss the use of adsorption chillers for waste heat recovery. The introduction discusses the need to undertake broader measures for the effective management of waste heat in the industry and discusses the benefits and technical problems related to heat recovery in industrial plants. In addition, heat sources for adsorption chillers and their application examples were described. The principle of operation of adsorption chillers is explained in the next chapter. Heat sources for adsorption chillers are indicated and their application examples are described. The above considerations have allowed the benefits and technical obstacles related to the use of adsorption chillers to be highlighted. The currently used adsorbents and adsorbates are discussed later in the article. The main part of the paper discusses the use of adsorption chillers for waste heat management in the glassworks. The calculations assumed the natural gas demand of 20.1 million m3 per year and the electricity demand of 20,000 MWh/year. As a result of conducted calculations, a 231 kW adsorption chiller, ensuring the annual cold production of 2,021 MWh, was selected. The economic analysis of the proposed solution has shown that the investment in the adsorption chiller supplied with waste heat from the heat recovery system will bring significant economic benefits after 10 years from its implementation, even with total investment costs of PLN 1,900,000. However, it was noted that in order to obtain satisfactory economic results the production must meet the demand while the cost of building a heat recovery system shall not exceed PLN 1 million.
Celem artykułu było rozważenie problemu zagospodarowywania ciepła odpadowego przy wykorzystaniu chłodziarek adsorpcyjnych. Na początku wskazano genezę potrzeby podjęcia szerszych działań na rzecz efektywnego zagospodarowywania ciepła odpadowego w przemyśle oraz omówiono korzyści i problemy techniczne związane z odzyskiem ciepła w zakładach przemysłowych. W następnym rozdziale objaśniono zasadę działania chłodziarek adsorpcyjnych. Z kolei wskazano źródła ciepła dla chłodziarek adsorpcyjnych oraz opisano ich przykładowe zastosowania. Powyższe rozważania pozwoliły na uwypuklenie korzyści i barier technicznych związanych z wykorzystywaniem adsorpcyjnych urządzeń chłodniczych. W następnej części pracy scharakteryzowano stosowane obecnie adsorbenty i adsorbaty. W zasadniczej części pracy przeprowadzono analizę wykorzystania chłodziarek adsorpcyjnych do zagospodarowania ciepła odpadowego w hucie szkła. W obliczeniach rozważono przykładową hutę szkła, której zapotrzebowanie na gaz ziemny wynosi 20,1 mln m3/rok, a zapotrzebowanie na energię elektryczną wynosi 20 000 MWh/rok. W efekcie przeprowadzonych kalkulacji dobrano chłodziarkę adsorpcyjną o mocy 231 kW, która zapewni roczną produkcję chłodu wynoszącą 2021 MWh. Analiza ekonomiczna zaproponowanego rozwiązania wykazała, że inwestycja w chłodziarkę adsorpcyjną zasilaną ciepłem odpadowym z instalacji odzysku ciepła przyniesie znaczące korzyści ekonomiczne po 10 latach od jej zrealizowania nawet przy sumarycznych nakładach inwestycyjnych wynoszących 1 900 000 zł. Zaznaczono jednak, że uzyskanie tak zadawalających wyników ekonomicznych będzie możliwe tylko wtedy, gdy w hucie szkła będzie zapewniony ciągły odbiór chłodu, a koszt budowy instalacji odzysku ciepła nie przekroczy 1 mln zł.
Źródło:
Polityka Energetyczna; 2019, 22, 2; 89-106
1429-6675
Pojawia się w:
Polityka Energetyczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Assessment of possibilities for reusing waste heat to cover needs for heating in Bulten Poland S.A.
Ocena możliwości wykorzystania ciepła odpadowego w celu zaspokojenia zapotrzebowania na moc grzewczą w zakładzie Bulten Polska S.A.
Autorzy:
Broniszewski, M.
Werle, S.
Powiązania:
https://bibliotekanauki.pl/articles/389025.pdf
Data publikacji:
2017
Wydawca:
Towarzystwo Chemii i Inżynierii Ekologicznej
Tematy:
energy efficiency
heat recovery
waste heat
SyNiS
industrial energy audit
sustainable development
efektywność energetyczna
odzysk ciepła
ciepło odpadowe
przemysłowy audyt energetyczny
rozwój zrównoważony
Opis:
Contemporary industrial and economic development, due to the dynamic progress of civilization and technology, requires significantly increased amount of energy. For this reason, we are looking for ways to use energy in a smart way, thus improving energy efficiency. One of many possibilities is to recover waste heat from energy-intensive technological processes. The process that creates a great potential for the waste heat collection and management is the process of fasteners’ heat treatment. The aim of the work is to evaluate the possibility of becoming independent from a district heating network in the production of fasteners for automotive industry plant Bulten Poland S.A. The idea is to use heat recovery systems installed on two hardening lines (air/water exchange) and on air compressors (oil/water exchange), which produce the necessary compressed air for bolts production processes. In addition, heat recovery is provided also in the oil bath of one furnace (oil/water exchange). The analyzed solution also assumes installation of two gas boilers, which will take a supporting role in case of extremely low outdoor temperatures and the necessity for increased needs for heat. An essential element of the carried out work is implementation of a superior energy management system (SyNiS), which enables efficient control of the sources’ power and the direction of heat transfer.
Współczesny intensywny rozwój przemysłu i gospodarki, wynikający z dynamicznego postępu cywilizacyjnego i technicznego, wymaga coraz większych nakładów energii. Z tego powodu poszukiwane są możliwości wykorzystywania zużywanej energii w sposób racjonalny, dbając tym samym o poprawę efektywności energetycznej. Jedną z możliwości jest odzyskiwanie ciepła odpadowego z energochłonnych procesów technologicznych. Procesem, który stwarza duży potencjał odbioru i zagospodarowania ciepła odpadowego, jest proces obróbki cieplnej elementów złącznych. Celem pracy jest ocena możliwości uniezależnienia się od dostaw ciepła z miejskiej sieci ciepłowniczej w Zakładzie produkcyjnym elementy złączne dla przemysłu motoryzacyjnego Bulten Polska S.A. Zaproponowano wykorzystanie systemów odzysku ciepła zainstalowanych na dwóch liniach do hartowania wyrobów (wymiana powietrze–woda), oraz na sprężarkach olejowych (wymiana olej–woda), które produkują sprężone powietrze niezbędne w procesach produkcji śrub. Dodatkowo przewidziano odzysk ciepła w wannie olejowej jednego z pieców (wymiana olej–woda). Analizowane rozwiązanie zakłada również instalację dwóch kotłów gazowych, które będą pełnić rolę wspomagającą, w przypadku niższych temperatur zewnętrznych i konieczności dogrzania zakładu. Istotnym elementem przeprowadzonych prac jest wdrożenie nadrzędnego systemu zarządzania energią (SyNiS), umożliwiającego efektywne sterowanie mocą źródeł oraz kierunkiem przesyłu ciepła.
Źródło:
Ecological Chemistry and Engineering. A; 2017, 24, 2; 157-167
1898-6188
2084-4530
Pojawia się w:
Ecological Chemistry and Engineering. A
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance Analysis Based on Experimental Data of Backpressure Steam Turbine for Cogeneration in Saturated Steam Applications
Autorzy:
Vescovi, Guilherme
Grazziotin, Gabriel
Souza, Tales
Guillen, Jorge
Quan, Ge
Powiązania:
https://bibliotekanauki.pl/articles/2051697.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
steam turbine
cogeneration
energy efficiency
heat waste
saturated steam
turbina parowa
kogeneracja
efektywność energetyczna
ubytki ciepła
Opis:
This paper aims to validate the performance capabilities of a Pressure Reducing Turbine (PRT) with respect to initial predictions based on analytic calculations. The designed equipment was installed in a beverage facility, located in Brazil. The validation procedure consists of analyzing the data collected in several periods of PRT’s operation, accessed remotely via an online server. The analysis of empirical data identifies the behavior of two key variables: generated power and effective efficiency. However, the observed boundary conditions differed significantly from expected values, forcing the turbine to operate in off-design conditions. The turbine model was hence refined and used to predict the PRT’s performance in such conditions. Results showed satisfactory accuracy for both power and efficiency predictions.
Źródło:
Civil and Environmental Engineering Reports; 2021, 31, 2; 274-292
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Projekty realizowane przez „Poltegor-Instytut” w ramach programu Interreg Europa Środkowa
Projects realised by „Poltegor-Institute” within Interreg Central Europe Program
Autorzy:
Rogosz, Barbara
Resak, Marta
Szczepiński, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/2029265.pdf
Data publikacji:
2021
Wydawca:
Poltegor-Instytut Instytut Górnictwa Odkrywkowego
Tematy:
Interreg Europa Środkowa
współpraca międzynarodowa
odnawialne źródła energii
efektywność energetyczna
ciepło odpadowe
biowęgiel
Interreg Central Europe
international cooperation
renewable energy sources
energy efficiency
waste heat
biochar
Opis:
Celem artkułu jest zaprezentowanie projektów zrealizowanych przez „Poltegor-Instytut” w ramach programu Interreg Europa Środkowa finansowanego z Europejskiego Funduszu Rozwoju Regionalnego.
The main aim of the paper is to present projects realised by „Poltegor-Institute” within Interreg Central Europe Program.
Źródło:
Górnictwo Odkrywkowe; 2021, 62, 2; 37--43
0043-2075
Pojawia się w:
Górnictwo Odkrywkowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dual ORC-Brayton power system for waste heat recovery in heavy-duty vehicles
Autorzy:
Cholewiński, M.
Pospolita, W.
Błoński, D.
Powiązania:
https://bibliotekanauki.pl/articles/224018.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
organic Rankine cycle
Brayton cycle
energy efficiency
road transport
waste heat utilization
cykl Rankina
cykl Braytona
efektywność energetyczna
transport drogowy
wykorzystanie ciepła odpadowego
Opis:
Reducing the amount of energy required in industrial activities is one of the proven ways to achieve major cost savings, especially in the face of soaring energy prices. In the transport sector, besides the financial benefits, low energy consumption leads to the significant reduction of emissions of many pollutants. In this paper the new concept of dual power technology, dedicated to heavy road transport, was modelled and analysed by computer simulations. The combination of organic Rankine cycle and Brayton cycle was proposed, where the waste heat of fumes was recognized as a upper heat source, whereas the surrounding was adopted to be the lower one. Improvement of total energy conversion efficiency of the truck was the key success factor. Environmental friendly fluids (air and R123) were utilised. The operating parameters, power characteristics and energy streams (i.e. dispersion) of the system were evaluated, calculated and commented from the perspective of its theoretical profitability. The calculated net power capacity of analysed dual system was around 50 hp for 100% load. However, when the engine load is below 50% of nominal capacity, the power generation of combined system might be lower than in the case of single ORC system.
Źródło:
Archives of Transport; 2016, 39, 3; 7-19
0866-9546
2300-8830
Pojawia się w:
Archives of Transport
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-6 z 6

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies