Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cooling efficiency" wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Natural ventilation and energy efficiency in non-domestic buildings
Autorzy:
Pieczara, J.
Powiązania:
https://bibliotekanauki.pl/articles/101474.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
natural ventilation
adaptive thermal comfort
energy efficiency
air quality
passive cooling
risk of overheating
thermal mass
Opis:
Over the past 50 years the use of air conditioning in non-domestic buildings has become a norm and an indicator of status. Today the rediscovering of the natural ventilation is a part of rediscovering the buildings’ energy efficiency, or maybe even a part of a wider approach, which is a desire to be closer to nature. The main task of all ventilation systems is to maintain an appropriate indoor air quality and to improve the indoor environment. Natural ventilation systems could do the above using less energy than mechanical systems. However, it requires also the implementation of other passive measures. The most important of them are: the reduction of the harmful air contaminants, the control of heat gains, the exposition of the building’s thermal mass and utilisation of the night cooling. Because of energy efficiency and thermal comfort reasons, in temperate climate ventilation systems have to work according to at least three scenarios: spring/autumn, winter and summer. The thermal comfort parameters in naturally ventilated buildings are usually more variable than in air-conditioned ones, what does not mean that the occupants will experience thermal discomfort. Therefore, thermal comfort in passively ventilated buildings should be evaluated according to the adaptive comfort standard, appropriated for the naturally ventilated buildings. The natural ventilation has its limits and probably not all buildings can be ventilated naturally. From the energy efficiency and thermal comfort reasons, implementing the mixed mode systems is sometimes more feasible. However, the real reason why the full potential of natural ventilation could not be explored is very often the lack of confidence in relying exclusively on it.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, III/1; 935-947
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Modelling of a thermoelectric self-cooling system based on thermal resistance networks for linear direct drives in machine tools
Autorzy:
Uhlmann, Eckart
Salein, Sebastian
Polte, Mitchel
Triebel, Florian
Powiązania:
https://bibliotekanauki.pl/articles/99421.pdf
Data publikacji:
2020
Wydawca:
Wrocławska Rada Federacji Stowarzyszeń Naukowo-Technicznych
Tematy:
legal restrictions
productivity
energy efficiency
thermoelectric generator
cooling
modelling
MATLAB/Simulink
Opis:
The use of direct drives in linear and rotary axes as well as increased power density of main drives offer the potential to raise feet rate, acceleration and thus allow higher productivity of machine tools. The induced heat flow rates of these drives could lead to thermo-elastic deformations of precision related machine tool components. In order to reduce thermally caused displacements of the tool-center-point and to prevent a negative impact on the achievable accuracy, the induced heat flow rates of main drives must be dissipated by effective cooling systems. These systems account for a major share of the machine tool’s total energy consumption.With the intention to overcome the area of conflict regarding productivity and energy efficiency, a so called thermoelectric self-cooling system has been developed. To convert a proportion of thermal losses into electrical energy, thermoelectric generators are placed in the heat flow between the primary part of a linear direct drive and the cooling system. The harvested energy is directly supplied to a pump of the water cooling circuit, which operates a decentralised cooling system with reasonable coolant flow rates. For predicting the thermoelectric system behaviour and to enable a model-based design of thermoelectric self-cooling systems, a thermal resistance network as a system simulation in MATLAB/Simulink is presented. The model is applied to a feed unit with a linear direct drive and allows the calculation of harvested energy as well as the simulation of steady and transient states of the cooling system. The comparison of simulative and experimental determined data indicates a predominantly high model prediction accuracy with short simulation times. At an early stage of development the model turns out to be a powerful tool for design and analysis of water flow thermoelectric self-cooling systems.
Źródło:
Journal of Machine Engineering; 2020, 20, 1; 43-57
1895-7595
2391-8071
Pojawia się w:
Journal of Machine Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Active management of equipment cooling in hoteling data centers
Aktywne zarządzanie przepływem powietrza w centrach danych świadczących usługi kolokacji
Autorzy:
Opaliński, A.
Powiązania:
https://bibliotekanauki.pl/articles/268238.pdf
Data publikacji:
2015
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
air flow
modeling
management
energy efficiency
przepływ powietrza
modelowanie
zarządzanie
efektywność energetyczna
Opis:
Hoteling data centers are designated for housing computing and storage units of many, usually small customers, as opposed to traditional data centers supporting own computing and storage resources of a bigger company. One of the services to be provided to consumer’s equipment is cooling. Cooling in data centers is prevalently achieved by circulating air in computer room. Efficient cooling requires delivering cold air from central cooling units directly to the equipment that needs it, in appropriate quantity, and at the right time. But with centralized cooling, hot spots and cold spots arise in computer room, caused by uneven, uncontrolled heat generation. The proposed active cold air flow management is to periodically input data from sensors into a model which calculates parameters at every floor localization based on measurements taken at the most reliable measurement locations. Such model has been created and verified by implementation in an industrial data center.
Centra danych świadczące usługi kolokacji oferują przestrzeń fizyczną i infrastrukturę do działania sprzętu obliczeniowego małych klientów, w odróżnieniu od tradycyjnych centrów danych obsługujących zasoby własnej, większej firmy. Jedną z usług świadczonych klientom jest usługa chłodzenia ich sprzętu. Najczęstszą metodą chłodzenia w centrach danych jest obieg powietrza chłodzącego w serwerowni. Efektywne chłodzenie polega jednak na tym, by doprowadzać chłodne powietrze z centralnych jednostek chłodzących do odpowiedniej lokalizacji w serwerowni, we właściwej ilości, i we właściwym czasie. Stosowanie centralnych jednostek chłodzących bez dodatkowych zabiegów skutkuje jednak powstawaniem w serwerowni miejsc przegrzanych i miejsc przechłodzonych. Proponowane rozwiązanie aktywnego zarządzania powietrzem chłodzącym polega na modelowaniu parametrów w każdej lokalizacji serwerowni na podstawie pomiarów dokonywanych periodycznie w miejscach serwerowni oferujących najbardziej niezawodne wyniki. Stosowny model został opracowany i zweryfikowany poprzez wdrożenie w jednym z przemysłowych centrów danych.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2015, 47; 127-130
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Energy and Economic Analysis of an R744 Cooling System as a Replacement for an R404A System
Autorzy:
Kozłowski, Cezary
Ruciński, Adam
Powiązania:
https://bibliotekanauki.pl/articles/24202373.pdf
Data publikacji:
2022
Wydawca:
Centrum Rzeczoznawstwa Budowlanego Sp. z o.o.
Tematy:
energy efficiency
refrigerant
f-gases
efektywność energetyczna
czynnik chłodniczy
f-gazy
Opis:
High consumption of energy in HVACR industry need to be reduced according to intense fossil fuels usage. It is dangerous for our climate and then for our health and life quality of next generations. The main aim of the study is to compare two cooling systems with the same cooling capacity but with different working refrigerant. One of them is R404A (fluorinated gas) and another is R744 (carbon dioxide). The question is, which of the systems uses lower amount of energy and which of them has lower LCC. The ‘carbon path’ – CO2 emmision is considered too. In the paper the configuration of the systems were established. The cycle with R404A is straight one stage compressor refrigeration system compare to supercritical compression refrigeration system with R744. The calculation process was done in Pack Calculation Pro software. It gives some databases with climate data which helps to find exploitation energy usage and energy cost with ‘carbon path’ calculations. For a system based on the use of R744 refrigerant, electricity consumption is lower than when using R404A refrigerant. Particularly large savings are generated in winter. Annual savings can be estimated at 28%. This is due to the difference in average annual EER of 1.15. Then, calculation introduced that total emission for the system with R404A is nearly 32% higher than in case of R744 supercritical compression system. The comparison done in this paper shows that supercritical compression systems with R744 is good alternative technology for those with fluorinated gases. However, some technical problems should be improved to make this technology much more efficient, cheaper and safe.
Źródło:
Modern Engineering; 2022, 3; 18--26
2450-5501
Pojawia się w:
Modern Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efficient conversion of energy in the conditions of trigeneration of heat, cooling and electric power
Efektywna konwersja energii w trójgeneracji ciepła, chłodu i energii elektrycznej
Autorzy:
Viktarovich, N
Powiązania:
https://bibliotekanauki.pl/articles/408034.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
trigeneration
CCHP
energy efficiency
primary energy saving
trójgeneracja
efektywność energetyczna
oszczędność energii pierwotnej
Opis:
The paper presents the efficiency comparison of the trigeneration system with respect to the separate generation of heat, cooling and electricity. Trigeneration Primary Energy Saving (TPES) indicator was adopted as an assessment criterion. The results of calculations are presented, based on which the analysis of the effect of a variable rate of heat used for cooling, as well as the turbine inlet temperature, on trigeneration system operations have been performed.
W pracy przedstawiono porównanie wydajności układu trójgeneracyjnego w odniesieniu do układu z oddzielną generacją ciepła, chłodu i energii elektrycznej. Jako kryterium oceny przyjęto wskaźnik względnej oszczędności energii pierwotnej (ang. Trigeneration Primary Energy Saving) TPES. Zaprezentowano wyniki obliczeń symulacyjnych, na podstawie których przeprowadzono analizę wpływu zmiennych wartości udziału ciepła wykorzystywanego do produkcji chłodu oraz temperatury spalin na wlocie do turbiny na efektywność pracy układu trójgeneracyjnego.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2015, 4; 48-51
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Influence of Window Roller Blinds on Energy Consumption in Residential Buildings in Serbia
Autorzy:
Djoković, Jelena M.
Nikolić, Ružica R.
Bokůvka, Otakar
Pastorková, Jana
Powiązania:
https://bibliotekanauki.pl/articles/27323565.pdf
Data publikacji:
2023
Wydawca:
Stowarzyszenie Menedżerów Jakości i Produkcji
Tematy:
exterior window blinds
heat load
cooling load
lighting
energy efficiency
rolety zewnętrzne
obciążenie cieplne
obciążenie chłodnicze
oświetlenie
efektywność energetyczna
Opis:
Roller blinds are devices that are retracted and wrapped in a box above the window opening and are used to protect against the solar radiation. Those are the well-known devices with distinct advantages over the fixed external dimming elements. The influence of external blinds on the internal thermal environment in climatic conditions in the Republic of Serbia, the city of Kragujevac, was considered in this research. An external blind was installed in the test room and its influence on the internal temperature was compared with the internal temperature of the room without the blind. Real-time monitoring was carried out in February and August 2023. The results presented in this paper show that the blind reduces the temperature in summer by 3.57ºC and increases it in winter by 1.76ºC. The cooling load can be reduced by about 20%, and the heat load by about 15%.
Źródło:
System Safety : Human - Technical Facility - Environment; 2023, 5, 1; 75-82
2657-5450
Pojawia się w:
System Safety : Human - Technical Facility - Environment
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Bibliometrics and scientometric review: perspectives and developments in the use of green roofs
Przegląd bibliometryczny i naukometryczny: perspektywy i rozwój w zakresie wykorzystania dachów zielonych
Autorzy:
Rzeszowska, Natalia
Powiązania:
https://bibliotekanauki.pl/articles/27313962.pdf
Data publikacji:
2023
Wydawca:
Zachodniopomorski Uniwersytet Technologiczny w Szczecinie. Wydawnictwo Uczelniane ZUT w Szczecinie
Tematy:
climate change
energy efficiency
green roofs
scientometric review
stormwater management
urban cooling
urban heat island
analiza naukometryczna
chłodzenie budynków
efektywność energetyczna
miejskie wyspy ciepła
zmiany klimatu
zagospodarowanie wody opadowej
dach zielony
Opis:
Green roofs are a multifunctional element of the building envelope, which, with appropriate modifications, can offer many benefits not only for its direct users, but also positively affect the environment around it. Global climate change and rapid urbanization have presented us with a number of urban challenges that negatively affect the physical and mental health of city dwellers. The subject of the article is to present the perspectives and main development trends in the use of green roofs in architecture. On the basis of the bibliometrics and scientometric analysis of the selected subject, the main research trends were presented, the countries contributing most to its development were distinguished, and the most influential authors were presented.
Dachy zielone to multifunkcyjny element obudowy budynku, który przy odpowiednich modyfikacjach może oferować wiele korzyści nie tylko dla jego bezpośrednich użytkowników, ale również pozytywnie wpływać na środowisko wokół niego. Globalne zmiany klimatyczne i szybka urbanizacja postawiły przed nami szereg wyzwań miejskich, które negatywnie wpływają na zdrowie fizyczne i psychiczne mieszkańców miast. Przedmiotem artykułu jest przedstawienie perspektyw oraz głównych nurtów rozwoju w zakresie wykorzystania dachów zielonych w architekturze. Na podstawie analizy bibliometrycznej i naukometrycznej wybranej tematyki, zaprezentowano główne nurty badań, wyodrębniono najbardziej przyczyniające się do jej rozwoju kraje oraz przedstawiono najbardziej wpływowych autorów.
Źródło:
Przestrzeń i Forma; 2023, 54; 98--120
1895-3247
2391-7725
Pojawia się w:
Przestrzeń i Forma
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies