Tytuł:
Fretting Corrosion Studies of Materials Used for Elements of Hip Joint Endoprostheses
Badania fretting-korozji materiałów stosowanych na elementy endoprotez stawu biodrowego
Autorzy:
Wielowiejska-Giertuga, A.
Wiśniewski, T.
Rubach, R.
Powiązania:
https://bibliotekanauki.pl/articles/188558.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoprosthesis
fretting
corrosion
wear
metal-on-metal articulation
endoproteza
korozja
zużycie
skojarzenie materiałowe metal-metal
Opis:
The operational durability of a hip endoprosthesis depends, among others, on the intensity of the damage processes of kinematic junction elements caused by fretting corrosion processes. In the article, the results of comparative studies on the fretting corrosion resistance of alloys commonly used for hip joints, i.e. Ti6Al4V, CoCrMo, stainless steel M30NW, and 316LVM, are presented. The research was carried out by means of a tribological pin-on-disc tester working in reciprocating motion, integrated with a potentiostat equipped with a triac electrode. The tribosystem was a pin pressed by a constant force to a reciprocating disc with a certain amplitude and frequency. The tests were carried out in a medium of aqueous bovine serum heated to 37°C. The conducted comparative tests of the above mentioned materials will allow selection of the best material combination in terms of tribological and fretting corrosion resistance. Under optimized conditions, the modified oils obtained a needed appropriate viscosity class.
Trwałość eksploatacyjna endoprotez stawu biodrowego zależna jest między innymi od intensywności procesów niszczenia elementów połączeń kinematycznych wywołanych procesami korozji frettingowej. W artykule przedstawiono wyniki porównawczych badań odporności na korozję frettingową stopów powszechnie stosowanych na elementy endoprotez stawu biodrowego: Ti6Al4V, CoCrMo, M30NW oraz 316LVM. Badania realizowano za pomocą testera tribologicznego typu pin-on-disc pracującego w ruchu posuwisto-zwrotnym, zintegrowanego z potencjostatem wyposażonym w układ trójelektrodowy. Skojarzenie badawcze stanowił trzpień dociskany ze stałą siłą do płytki poruszającej się ruchem posuwisto-zwrotnym o określonej amplitudzie i częstotliwości. Testy przeprowadzono w środowisku roztworu wodnego surowicy bydlęcej podgrzanej do temperatury 37°C. Przeprowadzone testy porównawcze wymienionych materiałów pozwolą na wytypowanie najkorzystniejszego skojarzenia materiałowego pod względem tribologicznym oraz odporności na fretting-korozję.
Źródło:
Tribologia; 2018, 281, 5; 143-151
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on Friction Wear of Hip Joint Endoprostheses of Polyethylene-Metal Material Combination on Hip Joint Simulator
Badania tribologiczne endoprotez stawu biodrowego o skojarzeniu polietylen–metal na symulatorze stawu biodrowego
Autorzy:
Wiśniewski, T.
Wielowiejska-Giertuga, A.
Rubach, R.
Łapaj, Ł.
Magda, J.
Powiązania:
https://bibliotekanauki.pl/articles/971352.pdf
Data publikacji:
2018
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
endoprosthesis
wear
polyethylene-on-metal articulation
endoproteza
zużycie
skojarzenie materiałowe polietylen–metal
Opis:
The article presents the results of friction wear tests of hip joint endoprostheses. The study comprised tests of endoprostheses, commercially available on the European market, used in total hip arthroplasty. The friction pair was formed by an actual cupacetabular cup made of ultra-high molecular weight polyethylene (PE-UHMW) along with a head having a diameter of 28 mm made of stainless steel FeCrNiMnMoNbN. The friction and wear tests were performed using an SBT 01.2 hip joint simulator of the authors’ own design, which was constructed taking into account the ISO 14242-1 standard. Bovine serum was used as the lubricant. The tests of each friction pair were made up to 5·106cycles of motion. During the tests, simulator operation was interrupted every 5·105 cycles to replace the lubricating liquid, and mass control was performed every 1·106 cycles. Prior to testing, the polyethylene cup was soaked in the lubricant to minimize liquid absorption during the test. Proper preparation of the cup and testing by taking into account a control group weight measurement allowed an accurate determination of the mass loss of the polyethylene cup.
Przedstawiono wyniki badań tarciowo-zużyciowych endoprotez stawu biodrowego. Materiał badany stanowiły endoprotezy komercyjne dostępne na rynku europejskim, stosowane w alloplastyce całkowitej stawu biodrowego. Parę trącą tworzyła panewka wykonana z polietylenu o ultrawysokiej masie cząsteczkowej PE-UHMW wraz z głową o średnicy 28 mm wykonaną ze stali o symbolu producenta SS (FeCrNiMnMoNbN). Badania tarciowo-zużyciowe przeprowadzono przy użyciu symulatora ruchu stawu biodrowego SBT 01.2 własnej konstrukcji, który skonstruowany został w oparciu o normę ISO 14242-1. Jako medium smarujące zastosowano surowicę bydlęcą, która przygotowywana była do testów zgodnie z wytycznymi opisanymi w normie ISO 14242-1. Dla każdej pary trącej zadana liczba cykli ruchu wynosiła 5·106. W trakcie trwania testów, co 5·105 cykli praca symulatora była przerywana celem wymiany cieczy smarującej, a co 1·106 przeprowadzano kontrolę masy próbek. Przed przystąpieniem do testów tarciowo-zużyciowych polietylenowa panewka namaczana była w cieczy smarującej celem zminimalizowania absorpcji cieczy w trakcie trwania testu. Odpowiednie przygotowanie panewek oraz przeprowadzenie testu z uwzględnieniem grupy kontrolnej pozwoliło na określenie zużycia masowego panewek polietylenowych.
Źródło:
Tribologia; 2018, 281, 5; 153-158
0208-7774
Pojawia się w:
Tribologia
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies