Tytuł:
Pollutant concentrations from deciduous wood fuelled heat station
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185275.pdf
Data publikacji:
2011
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
stacja ciepła
spalanie
emisja
drewno
heat station
wood
combustion
emission
Opis:
CO, NO, NO2 and dust concentrations from combustion of deciduous wood (birch, beech, lime-tree) logs and pellets in two heating boilers (15 and 25 KW), situated in a heat station were investigated. Time dependences of pollutant concentrations as well as the impact of temperature in the combustion chamber and oxygen concentration on pollutant concentrations were presented. Pollutant emission indices have been estimated.
Źródło:
Chemical and Process Engineering; 2011, 32, 1; 41-55
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Concentrations of carbon monoxide and nitrogen oxides from a 25 kW boiler supplied periodically and continuously with wood pellets
Autorzy:
Juszczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/185416.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pelety
spalanie
emisja
stacja ciepła
coniferous
wood pellets
combustion
emission
heat station
Opis:
The impact of the fuel feeding mode (continuous or periodic with different stand-by/operation time ratios) on carbon monoxide (CO) and nitrogen oxides (NO, NOx) concentration values in the flue gas was analysed for coniferous wood pellet firing. Experiments were performed in a 25 kW water boiler equipped with an over-fed wood pellet furnace located in a full scale heat station simulating real-life conditions. Influence of oxygen concentration and temperature in the combustion chamber on carbon monoxide and nitrogen oxide concentrations was presented in diagrams. Dust and hydrocarbon concentrations were also monitored. It was concluded that the commonly used periodic fuel supply does not necessarily cause a significant increase of carbon monoxide concentration, as compared to the continuous fuel feeding mode. Continuous fuel supply can even induce higher carbon monoxide concentrations when fuel mass stream is not chosen properly. Each time new fuel type is used in a specific furnace, one should perform experiments to determine the adequate settings (stand-by/operation time ratio, fuel mass streams, air stream) to obtain the optimal, lowest possible emission for a certain boiler heat output.
Źródło:
Chemical and Process Engineering; 2014, 35, 2; 163-172
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ własności absorpcyjno-emisyjnych ściany wewnętrznej na charakterystykę cieplną fasady podwójnej
The efect of wall emission-absorption on thermal characteristic of DSF
Autorzy:
Heim, D.
Jabłoński, Ł.
Powiązania:
https://bibliotekanauki.pl/articles/363014.pdf
Data publikacji:
2007
Wydawca:
Instytut Fizyki Budowli Katarzyna i Piotr Klemm
Tematy:
fasady podwójne
absorpcja
emisja
magazynowanie ciepła
energooszczędność
emission
double facades systems
absorption
heat accumulation
Opis:
W niniejszej pracy przeanalizowano wpływ emisyjności powierzchni ściany pomidzy użytkową przestrze- nią budynku a przestrzenią podwójnej fasady na cieplne zachowanie się przegrody oraz jej wydajność energetyczną. Dyskretyzacji w przestrzeni dokonano za pomocą Metody Objętości Skończonych, zaś analizy symulacyjne wykonano metodą opartą na sprzężonym modelu wymiany ciepła i masy w budynkach [1]. Otrzymano wartości temperatur ekstremalnych w przestrzeni fasady oraz w pomieszczeniu znajdującym się w bezpośrednim, termicznym kontakcie z fasadą.
The paper presents and discusses the efect of the emission-absorption characteristics of the inner skin in double fasades systems (DSF). The second skin of fasades are design inter alia in order to keep the comfort and healthy indoor climate but the properties of inner elements may play so important role as ventilation or shading. The thermal analysis of DSF have been done using the whole building simulation technique -En- vironmental System Performance (ESP). The results of the air and shows the important differences between light and heavy traditional constructions
Źródło:
Fizyka Budowli w Teorii i Praktyce; 2007, T. 2; 79-82
1734-4891
Pojawia się w:
Fizyka Budowli w Teorii i Praktyce
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pollutant emission from a heat station supplied with agriculture biomass and wood pellet mixture
Autorzy:
Juszczak, M.
Lossy, K.
Powiązania:
https://bibliotekanauki.pl/articles/185505.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pozostałości rolnicze
drewno
spalanie
emisja
stacja ciepła
agricultural residue
wood
combustion
emission
heat station
Opis:
Tests for combustion of hay and sunflower husk pellets mixed with wood pellets were performed in a horizontal-feed as well as under-feed (retort) wood pellet furnace installed in boilers with a nominal heat output of 15 and 20 kW, located in a heat station. During the combustion a slagging phenomenon was observed in the furnaces. In order to lower the temperature in the furnace, fuel feeding rate was reduced with unaltered air stream rate. The higher the proportion of wood pellets in the mixture the lower carbon monoxide concentration. The following results of carbon monoxide concentration (in mg/m3 presented for 10% 02 content in flue gas) for different furnaces and fuel mixtures (proportion in wt%) were obtained: horizontal-feed furnace supplied with hay/wood: 0/100 - 326; 30/70 - 157; 50/50 - 301; 100/0 - 3300; horizontal-feed furnace supplied with sunflower husk/wood: 50/50 - 1062; 67/33 - 1721; 100/0 - 3775; under-feed (retort) furnace supplied with hay/wood: 0/100 - 90; 15/85 - 157; 30/70 - 135; 50/50 - 5179; under-feed furnace supplied with sunflower husk/wood: 67/33 - 2498; 100/0 - 3128. Boiler heat output and heat efficiency was low: 7 to 13 kW and about 55%, respectively, for the boiler with horizontal-feed furnace and 9 to 14 kW and 64%, respectively, for the boiler with under-feed furnace.
Źródło:
Chemical and Process Engineering; 2012, 33, 2; 231-242
0208-6425
2300-1925
Pojawia się w:
Chemical and Process Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza energetyczno-ekologiczna wykorzystania pompy ciepła do ogrzewania tunelu foliowego
Power use and ecological analysis for use of heat pump applied to heat a foil tunnel
Autorzy:
Kurpaska, S.
Latała, H.
Powiązania:
https://bibliotekanauki.pl/articles/287516.pdf
Data publikacji:
2007
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
tunel foliowy
pompa ciepła
emisja
substancja szkodliwa
ciepło
foil tunnel
heat pump
emission
harmful wastes
heat
Opis:
W pracy przedstawiono wyniki badań związanych z efektami energetyczno-ekologicznymi wykorzystania pompy ciepła do ogrzewania tunelu foliowego. Pompa grzewcza pracowała w układzie hybrydowym, tzn. jako dolne źródło ciepła wykorzystano energię zmagazynowaną w zbiorniku cieczowym. W zbiorniku zainstalowano wymiennik stanowiący dolne źródło ciepła sprężarkowej pompy grzewczej. Uzyskane wyniki przeliczono na zmiany emisji substancji szkodliwych emitowanych do atmosfery w wyniku spalania tradycyjnego nośnika ciepła.
The paper presents test results pertaining to power use and ecologic effects for use of heat pump applied to heat a foil tunnel. The heat pump was operated in a hybrid system, i.e. the energy stored in a tank with liquid was used as a lower source of heat; the mentioned tank being equipped with a heat exchanger to be utilized as a lower source of heat for compressor type heat pump. The obtained results were calculated into changes of harmful waste substances flowing to the environment as a result of traditional burning of the heating medium.
Źródło:
Inżynieria Rolnicza; 2007, R. 11, nr 6 (94), 6 (94); 121-127
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Limiting odour emission from piggery trough application of heat recovery system
Ograniczanie emisji odorów z tuczarni poprzez zastosowanie instalacji do odzysku ciepła
Autorzy:
Rzeźnik, W.
Mielcarek, P.
Rzeźnik, I.
Powiązania:
https://bibliotekanauki.pl/articles/93428.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
odour emission
deep litter
heat pump
cooling manure
odór
emisja
głęboka ściółka
pompa ciepła
schładzanie obornika
Opis:
The aim of the study was to determine the effect of manure cooling by the use of the heat recovery system on odour emission from a deep litter piggery. Annual comparative research was carried out in a twinroom deep litter piggery located in Wielkopolska Voivodeship. The recovered heat was transferred to central heating and domestic hot water systems of a residential building. The study showed that the average odour emission rate from the room, where heat was recovered (0.192±0.083 ouE·s-1·kg m.c.-1) was lower than in the room without heat recovering (0.273±0.138 ouE·s-1·kg m.c.-1) (p<0.05). The difference was 27%. It was also found that there was statistically significant strong correlation (r =0.86) between the amount of the recovered heat and the percentage odour emission reduction (p <0.05). This relationship was described by the logarithmic regression line y=12.5ln(x)-21.5 (r2=0.74).
Celem pracy było określenie wpływu schładzania obornika, w kojcu z głęboką ściółką na emisję odorów z tuczarni, poprzez zastosowanie instalacji do odzysku ciepła. Roczne badania porównawcze przeprowadzono w dwukomorowej tuczarni na głębokiej ściółce znajdującej się w województwie wielkopolskim. Budynek wyposażony był w instalację do odzysku ciepła z głębokiej ściółki. Dolnym źródłem był obornik znajdujący się w kojcu, natomiast górnym były instalacje centralnego ogrzewania i ciepłej wody użytkowej budynku mieszkalnego. W pracy wykazano, że średni wskaźnik emisji odorów z komory, gdzie odzyskiwano ciepło (0,192±0,083 ouE·s-1·kgm.c.-1) był mniejszy, niż w komorze bez odzysku ciepła (0,273±0,138 ouE·s-1·kgm.c.-1) (p<0,05). Różnica ta wynosiła 27%. Stwierdzono również, że między ilością pobranego ciepła, a procentową redukcją emisji odorów istnieje statystycznie istotna silna zależność, r=0,86 (p<0,05). Opisano ją dobrze dopasowaną do danych empirycznych (r2=0,74) logarytmiczną linią regresji o równaniu y=12,5ln(x) – 21,5.
Źródło:
Agricultural Engineering; 2016, 20, 1; 167-176
2083-1587
Pojawia się w:
Agricultural Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Natural gas saving and emissions decrease in public health care sector – a case study
Ograniczenie zużycia gazu ziemnego i redukcja emisji w sektorze zdrowia publicznego – studium przypadku
Autorzy:
Mierka, Otto
Variny, Miroslav
Skalíková, Ingrida
Sámel, Peter
Kizek, Ján
Súth, Róbert
Nagy, Karol
Powiązania:
https://bibliotekanauki.pl/articles/396176.pdf
Data publikacji:
2019
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
public building
health care sector
natural gas
emission
heat loss
budynek użyteczności publicznej
gaz ziemny
emisja
straty ciepła
Opis:
A study on natural gas saving and emissions decrease in the public health care sector is presented. The analyzed hospital complex belongs to the largest ones in Slovakia and uses both hot water and water steam for heating purposes. Visual steam system inspection revealed serious inefficiencies, including steam venting, missing pipelines insulation and obsolete steam sources with dysfunctional blow-down system. Defined experiment with stepwise steam appliances shutdown enabled quantification of excess natural gas consumption due to these inefficiencies. Measures proposed for the solution of this state are inexpensive, with a short payback period. The expected natural gas savings amount up to 3200 MWh/year, which represents roughly 50% of the total natural gas consumption in the hospital complex.
Niniejszy artykuł prezentuje studium przypadku na temat ograniczenia zużycia gazu ziemnego i emisji w sektorze zdrowia publicznego. Analizowany kompleks szpitalny należy do największych na Słowacji i używa do ogrzewania zarówno ciepłej wody użytkowej, jak i pary wodnej. Kompleks ten będzie w najbliższych latach poddany renowacji, włącznie z instalacją dystrybucji mediów. Analiza obecnego systemu i wynikające z niej zaproponowane sposoby na zaoszczędzenie energii oferują redukcję kosztów powiązanych z przyszłą inwestycją. Wizualna ocena systemu dystrybucji pary wodnej ujawniła poważne wady tego systemu, w tym w odpowietrzaniu systemu, uszkodzonej bądź brakującej izolacji rur, przestarzałych bojlerach parowych z niedziałającym systemem usuwania zanieczyszczeń. Eksperyment ze stopniowym wyłączaniem urządzeń parowych umożliwił ilościowe określenie nadmiaru zużycia gazu ziemnego spowodowanego wspomnianymi niedostatkami. Metodologia takiego eksperymentu jest uniwersalna i łatwa w zastosowaniu w jakimkolwiek innym budynku użyteczności publicznej gdzie podobny system pary wodnej jest w użyciu. Zaproponowane rozwiązania dla poprawy takiego stanu są niedrogie i z krótkim czasem zwrotu inwestycji. Zastosowanie nowej izolacji rur, naprawa odwadniaczy oraz naprawa zaworów redukcyjno-regulacyjnych do odpowietrzania pary w odpowietrznikach są przedmiotem rozważań. Oczekiwana redukcja zużycia gazu ziemnego wynosi do 3200 MWh/rok, co stanowi około 50% rocznego zapotrzebowania tego gazu w kompleksie szpitalnym. Ocena środowiskowa zaproponowanych zmian pozwala oczekiwać redukcji emisji dwutlenku węgla na poziomie 644 ton rocznie oraz tlenków azotu na poziomie 0.75 ton rocznie.
Źródło:
Civil and Environmental Engineering Reports; 2019, 29, 1; 119-127
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ograniczanie emisji zanieczyszczeń gazowych z tuczarni poprzez zastosowanie instalacji do odzysku ciepła
Limiting emission of gas pollution from the fattening house through application of heat recovery installation
Autorzy:
Rzeźnik, W.
Powiązania:
https://bibliotekanauki.pl/articles/288663.pdf
Data publikacji:
2013
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
emisja
zanieczyszczenia gazowe
głęboka ściółka
pompa ciepła
schładzanie
obornik
emission
gas pollution
deep bedding
heat pump
cooling manure
Opis:
Celem pracy było określenie wpływu schładzania obornika w kojcu z głęboką ściółką, poprzez zastosowanie instalacji do odzysku ciepła, na emisję zanieczyszczeń gazowych (NH3, N2O oraz CH4) z tuczarni. Badania porównawcze przeprowadzono w budynku dla trzody chlewnej utrzymywanej na głębokiej ściółce, wyposażonym w instalację do odzysku ciepła, w okresie jednego roku. Górnym źródłem były instalacje c.o. (centralne ogrzewanie) i c.w.u. (ciepła woda użytkowa) budynku mieszkalnego. W pracy wykazano, że między ilością pobranego ciepła a procentową emisją zanieczyszczeń gazowych (NH3, N2O, CH4) istnieje korelacja (p<0,05). Zależności te opisano logarytmicznymi krzywymi regresji: y = 10,8ln(x) - 26,2 (R2=0,83) dla amoniaku, y = 11,5ln(x) - 28,8 (R2=0,9) dla podtlenku azotu oraz y = 6,9ln(x) - 13,4 (R2=0,7) dla metanu. Schładzanie obornika w kojcu z głęboką ściółką poprzez zastosowanie instalacji do odzysku ciepła zmniejsza emisję gazów szkodliwych średnio o 15,7% dla NH3, o 16,2% dla N2O oraz o 12,1% dla CH4.
The objective of the paper was estimation of the impact of cooling manure in a pigpen with deep bedding through the use of the heat recovery installation on emission of gas pollution (NH3, N2O andCH4) from the fattening house. The research was carried out in the building for pigs maintained in deep bedding equipped with the heat recovery installation within one year. Central heating and utility hot water installations of a residential building constituted the upper source. The paper presents that between the amount of the collected heat and percentage emission of gas pollutions (NH3, N2O, CH4) there is a correlation (p<0.05). These relations were expressed with logarythmic regression curves: y = 10.8ln(x) - 2.2 (R2=0.83) for ammonia, y = 11.5ln(x) – 28.8 (R2=0.9) for nitrous oxide and y = 6.9ln(x) – 13.4 (R2=0.7) for methane. Cooling manure in a pigpen with deep bedding through the use of the heat recovery installation reduced emission of harmful gases at the average by 15.7% for NH3, and 16.2% for N2O and by 12.1% for CH4.
Źródło:
Inżynieria Rolnicza; 2013, R. 17, nr 3, t. 2, 3, t. 2; 331-339
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-8 z 8

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies