Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "magnetic field" wg kryterium: Temat


Wyświetlanie 1-13 z 13
Tytuł:
Method of estimating the exposure of the natural environment to 50 Hz electric and magnetic fields in power systems with distributed and centralized generations
Autorzy:
Zeńczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/140965.pdf
Data publikacji:
2016
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
distributed generation
electric field
magnetic field
power line
Opis:
The development of a distributed generation will influence the structure of the power transmission and distribution network. Distributed sources have lower power and therefore the lines of lower voltage are used. Therefore, the electric field intensity near such lines is lower. On the other hand magnetic field intensity may prove essential. The main aim of the paper is to present a method estimating the “ballast” of the natural environment at 50 Hz electric and magnetic fields in the power system, with distributed and centralized generation in real operating conditions.
Źródło:
Archives of Electrical Engineering; 2016, 65, 2; 295-304
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Using the EMTP/ATP program for calculation of electric and magnetic field distribution under overhead line
Zastosowanie programu EMTP/ATP do obliczania rozkładu pól i elektrycznych i magnetycznych pod linią napowietrzną
Autorzy:
Wiśniewski, J.
Anderson, E.
Karolak, J.
Powiązania:
https://bibliotekanauki.pl/articles/376500.pdf
Data publikacji:
2012
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
electric field
magnetic field
overhead line
EMTP-ATP
Opis:
This paper presents the method of calculation of the electric and magnetic fields under overhead transmission line with any number of circuits, phase positions, voltages and current loads. Calculations of this type usually require specialized and costly programs. The program EMTP/ATP is a royalty free tool to calculate the electric transient and steady states in complex power systems. You can use this program and through appropriate modeling the multi-phase wire system representing the line and measurement device calculate the strength of the electric and magnetic fields. The results of calculations are characterized by a very small error compared to the results obtained by using the specialized program. This method can be used with other popular engineering tools like Matlab/Simulink or PSCad.
W artykule przedstawiono metodę obliczeń pól elektrycznych i magnetycznych pod linią wysokiego napięcia o dowolnym układzie faz, liczbie torów, napięciach i obciążeniach. Obliczenia tego typu wymagają zwykle wyspecjalizowanych i kosztownych programów. Program EMTP/ATP jest bezpłatnym narzędziem do obliczania stanów ustalonych i nieustalonych w złożonych układach elektroenergetycznych. Można przy użyciu programu poprzez odpowiednie zamodelowanie układu wieloprzewodowego odwzorować układ pomiarowy pozwalający obliczyć wartość natężenia składowej elektrycznej i magnetycznej pola. Uzyskane wyniki obliczeń charakteryzują się bardzo małym błędem w stosunku do wyników uzyskanych wyspecjalizowanym programem. Metodę tę można stosować przy użyciu także innych szeroko rozpowszechnionych inżynierskich narzędzi jak Matlab/Simulink lub PSCad.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2012, 69; 73-80
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Power line magnetic field mitigation using a passive loop conductor
Autorzy:
Budnik, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/376311.pdf
Data publikacji:
2013
Wydawca:
Politechnika Poznańska. Wydawnictwo Politechniki Poznańskiej
Tematy:
magnetic field
electric field
electric power lines
Fourier transform
loop conductor
Opis:
The paper presents in a tutorial manner methods of the calculation of magnetic fields in vicinity of overhead electric power lines without and with passive mitigation loops. Exact and simplified methods of the determination of the magnetic field of a straight overhead conductor based on the Fourier transform technique are presented. The mitigation effects due to the passive loop are also investigated, whereas the mitigation loop can be treated as a rectangular loop (two-conductor closed mitigation loop) horizontal located under the power line. The decomposition of the magnetic fields in two components: magnetic field obtained in free space from the Biot-Savart law and the magnetic field produced by earth current shows that in practical cases the effects from earth currents can be neglected as compared with effects from line currents.
Źródło:
Poznan University of Technology Academic Journals. Electrical Engineering; 2013, 73; 137-145
1897-0737
Pojawia się w:
Poznan University of Technology Academic Journals. Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Optimization of electric and magnetic field intensities in proximity of power lines using genetic and particle swarm algorithms
Autorzy:
Król, K.
Machczyński, W.
Powiązania:
https://bibliotekanauki.pl/articles/141588.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
power line
electric field
magnetic field
optimization
genetic algorithm
particle swarm algorithm
Opis:
The paper presents optimization of power line geometrical parameters aimed to reduce the intensity of the electric field and magnetic field intensity under an overhead power line with the use of a genetic algorithm (AG) and particle swarm optimization (PSO). The variation of charge distribution along the conductors as well as the sag of the overhead line and induced currents in earth wires were taken into account. The conductor sag was approximated by a chain curve. The charge simulation method (CSM) and the method of images were used in the simulations of an electric field, while a magnetic field were calculated using the Biot–Savart law. Sample calculations in a three-dimensional system were made for a 220 kV single – circuit power line. A comparison of the used optimization algorithms was made.
Źródło:
Archives of Electrical Engineering; 2018, 67, 4; 829-843
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Szacowanie maksymalnego pola elektrycznego indukowanego w ciele człowieka przez zewnętrzne pole magnetyczne
Assessment of the maximum electric field induced by an external magnetic field
Autorzy:
Lisewski, T.
Mikołajczyk, A.
Abramik, S.
Powiązania:
https://bibliotekanauki.pl/articles/408842.pdf
Data publikacji:
2016
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
pole elektryczne
ocena ekspozycji
pole magnetyczne
SEMCAD X
electric field
exposure assessment
magnetic field
Opis:
Oceniając ekspozycję człowieka na zewnętrzne pole magnetyczne niskich częstotliwości brane pod uwagę jest maksymalne indukowane pole elektryczne w ciele człowieka będące skutkiem pola zewnętrznego. Pole elektryczne indukowane w człowieku nie jest wielkością mierzalną, może ono być jedynie szacowane za pomocą obliczeń analitycznych lub numerycznych. W przypadku obliczeń numerycznych wyznaczona wartość maksymalna obarczona jest błędem wynikającym z dyskretyzacji modelu ciała człowieka. Błąd ten powoduje zawyżenie poziomu ekspozycji. Zalecaną przez ICNIRP metodą redukcji błędów numerycznych jest uśrednianie i rozważanie 99 centyla wartości dla danej tkanki. W przypadku lokalnych źródeł pola prowadzi to z kolei do niedoszacowania poziomu ekspozycji. Niniejszy artykuł prezentuje nową metodę eliminacji błędów numerycznych polegającą na zastosowaniu filtru dolnoprzepustowego. Przedstawiono porównanie wyników uzyskanych bezpośrednio ze środowiska symulacyjnego SEMCAD X, wyników uśrednionych standardowymi metodami oraz wyników uzyskanych po zastosowaniu nowego filtra dolnoprzepustowego.
The maximum induced electric field by external low frequency magnetic fields is considered when evaluating exposure of a body to magnetic field. The induced electric field cannot be measured but can only be assessed using analytical or numerical calculations. In the case of numerical simulations results are affected by errors caused by discretization of a body model being exposed. This error causes overestimation of the exposure level. The recommended ICNIRP approach to reduce errors is to average the results over a small cubic volume, and then take into account the 99th percentile value for a specific tissue. When evaluating exposure from small or local sources taking into account the 99th percentile value leads to underestimation. This paper propose a new method of reducing numerical errors using low pass filter. There is also presented results obtained directly from the simulation platform SEMCAD X compared to averaged values, and to results obtained using the new filtering method.
Źródło:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska; 2016, 1; 63-65
2083-0157
2391-6761
Pojawia się w:
Informatyka, Automatyka, Pomiary w Gospodarce i Ochronie Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Diagnostyka pól elektromagnetycznych w wybranych stacjach radiolokacyjnych
Diagnostics of electromagnetic fields in chosen radar stations
Autorzy:
Brejwo, W.
Paś, J.
Powiązania:
https://bibliotekanauki.pl/articles/327220.pdf
Data publikacji:
2006
Wydawca:
Polska Akademia Nauk. Polskie Towarzystwo Diagnostyki Technicznej PAN
Tematy:
pole elektryczne
pole magnetyczne
widmo
stacja radiolokacyjna
electric field
magnetic field
spectrum
radar station
Opis:
W opracowaniu przedstawiono wyniki badań pól elektrycznych i magnetycznych, z zakresu częstotliwości od 5 Hz do 100 kHz, przy wybranych urządzeniach w stacjach radiolokacyjnych. Przedstawiono wyniki badań charakterystyk widmowych tych pól. Szczególną uwagę zwrócono na wytwarzane przy wskaźnikach radiolokacyjnych pola elektromagnetyczne, które uważane są za istotny czynnik wpływający na warunki pracy operatorów.
In the elaboration there were presented the results of measurements of electric and magnetic fields in the 5 Hz - 100 kHz range. The research was carried out near selected devices of radar stations. Besides, there were presented the results of the measurements of the splittings of the spectrum. Electromagnetic fields induced near the radar displays, regarded as an important factor, which influences the working conditions of crew, were especially taken into consideration.
Źródło:
Diagnostyka; 2006, 3(39); 79-86
1641-6414
2449-5220
Pojawia się w:
Diagnostyka
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Przegląd miar skutków narażenia na zmienne w czasie pole elektromagnetyczne i właściwości metrologicznych mierników, istotnych podczas oceny narażenia w środowisku pracy
A review of the effects of exposure to a time-varying electromagnetic field and the metrological properties of measurement devices that have a significant influence when evaluating exposure in the work environment
Autorzy:
Bieńkowski, P.
Karpowicz, J.
Kieliszek, J.
Powiązania:
https://bibliotekanauki.pl/articles/137758.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
zagrożenia elektromagnetyczne
narażenie pracowników
ocena ekspozycji
pole elektryczne
pole magnetyczne
electromagnetic hazards
workers’ exposure
exposure evaluation
electric field
magnetic field
Opis:
Eksploatacja wszystkich urządzeń i instalacji zasilanych prądem elektrycznym jest nierozerwalnie związana z zamierzoną lub niezamierzoną emisją energii elektromagnetycznej. W wyniku tej emisji pole elektromagnetyczne powszechnie występuje w środowisku. Bezpośrednim skutkiem oddziaływania pola z obiektami elektroprzewodzącymi (w tym z ciałem człowieka) jest indukowanie pola elektrycznego i prądu elektrycznego w eksponowanych obiektach (pojedynczych obiektach w tzw. wolnej przestrzeni lub w grupach obiektów połączonych galwanicznie). W organizmie człowieka mogą one wywołać elektrostymulację tkanek pobudliwych lub wzrost temperatury, co prowadzi do zaburzeń funkcjonowania organizmu lub utrudnia bezpieczne realizowanie obowiązków zawodowych. Przy identyfikacji, badaniach i ocenie parametrów narażeń na pola elektromagnetyczne są stosowane zarówno techniki pomiarowe, symulacje komputerowe, jak i analiza parametrów technicznych obiektów technicznych emitujących pola elektromagnetyczne. Zwykle największą miarodajność w przypadku oceny zagrożeń zawodowych mają badania in situ, ponieważ umożliwiają ocenę zarówno rzeczywistych parametrów pola elektromagnetycznego w specyficznych warunkach przestrzeni pracy, gdzie eksploatowane mogą być jednocześnie różnorodne urządzenia i instalacje elektryczne oraz rozmieszczone są zróżnicowane obiekty materialne modyfikujące morfologię ekspozycji (m.in. rozkład przestrzenny i zmienność w czasie), jak i ocenę warunków narażenia przy aktualnym stanie technicznym źródeł pola, który zmienia się wskutek zmiennych warunków ich eksploatacji i konserwacji oraz procesów starzeniowych urządzeń. W artykule omówiono: charakterystyki bezpośredniego i pośredniego oddziaływania pola elektromagnetycznego na organizm człowieka, miary skutków narażenia na zmienne w czasie pole elektromagnetyczne (o częstotliwości z pasma od 5 Hz do 300 GHz), parametry charakteryzujące pole elektromagnetyczne w środowisku (stosowane zgodnie z wymaganiami prawa pracy podczas oceny narażenia pracowników), zasady pomiaru pola elektrycznego i magnetycznego oraz właściwości metrologiczne mierników (istotne z punktu widzenia jakości pomiarów wykorzystywanych w dziedzinie bezpieczeństwa i higieny pracy). Ponadto scharakteryzowano czynniki determinujące niepewność pomiarów pola elektromagnetycznego w środowisku pracy, ze szczególnym uzasadnieniem wymagań określających parametry metrologiczne aparatury wykorzystywanej do pomiarów podjętych ze względu na ocenę zgodności warunków narażenia z ustalonymi limitami dotyczącymi natężenia pola elektrycznego i magnetycznego w miejscu pracy.
Any use of electric devices and installations is inextricably linked to the intentional or unintentional emission of electromagnetic energy. Consequently, the electromagnetic field is commonly present in the environment. The direct effects of the electromagnetic influence on electrically conductive objects (including the human body) consists in the electric field and current induction in exposed objects (single objects in the ‘free space, or in groups of objects with galvanic contact). In the human body, they may cause electrostimulation in electro sensitive tissues or an increase in temperature that may lead to malfunctions within the body or difficulties in the safe performance of professional duties. When identifying, investigating and evaluating the parameters of the electromagnetic field, various techniques can be applied: measurements, computer simulations or the analysis of parameters of technical objects emitting an electromagnetic field. The highest quality evaluation of occupational hazards usually comes from in-situ investigations. This is because they allow the evaluation of the real parameters of electromagnetic fields in the particular conditions of the workplace where various electric devices and installations may be used at the same time, and where various physical objects are present that might influence the exposure morphology (e.g. spatial distribution and time variability). They also permit an evaluation of the exposure conditions taking into account the actual technical stage of the field sources, which vary due to changes in the use and maintenance conditions, or due to aging devices. The article presents: the characteristics of direct and indirect interaction between the electromagnetic field and the human body, the measures of exposure to a time-varying electromagnetic field (5 Hz – 300 GHz frequency band), the parameters characterizing the electromagnetic field in the environment (used according to the labour law in evaluations of workers’ exposure), the principles of electric and magnetic field measurements and the metrological properties of measurement devices (significant from the point of view of the quality of measurements used in the area of occupational health and safety). Factors determining the uncertainty of electromagnetic field measurements are also characterized, focusing on the rationale for guidelines on the metrological parameters of devices used in measurements intended to evaluate whether exposure conditions comply with the established limits of electric and magnetic field strength at the workplace.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2016, 4 (90); 41-74
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pola elektromagnetyczne w budynkach ze stacjami transformatorowymi
Electromagnetic fields in buildings with transformer stations
Autorzy:
Gryz, K.
Karpowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/209311.pdf
Data publikacji:
2009
Wydawca:
Wojskowa Akademia Techniczna im. Jarosława Dąbrowskiego
Tematy:
inżynieria środowiska
stacje transformatorowe
pole magnetyczne
pole elektryczne
ekspozycja środowiska
environmental engineering
transformer stations
magnetic field
electric field
environment's exposure
Opis:
Przedstawiono problematykę zagrożeń elektromagnetycznych występujących w budynkach, w których zlokalizowane są stacje transformatorowe. Zaprezentowano wyniki badań indukcji magnetycznej pola magnetycznego zmiennego o częstotliwości przemysłowej 50 Hz w pomieszczeniach sąsiadujących ze stacjami transformatorowymi. Omówiono metody ograniczania pola magnetycznego w otoczeniu elektroenergetycznego wyposażenia budynków.
Transformer stations are sometimes located in dwellings and buildings with work space. Problems of electromagnetic fields produced by transformers and the need of their reduction in the buildings is important in the aspects of the possible health effects of chronic exposure to a low frequency magnetic field, even relatively weak (especially the possibility of increased cancer risk). Presented investigations were done in transformer stations 15/0.4 kV of power in the range of 160-1000 kVA and in the neighbouring working and living rooms. These investigations consisted of measurements of the rms value of magnetic flux density and electric filed strength in transformer stations, measurements of the rms value of magnetic flux density in rooms neighbouring to transformer stations and many hours registration of the rms value of magnetic flux density in rooms. Measurements were done in the so called ELF frequency range (50 Hz-2 kHz). Current loads of transformers were identified to establish their relation with the results of measurements of magnetic field. Magnetic flux density in the nearest rooms to transformer stations can reach values up to a few or a few tens of microtesla (µT) and is below a limit value for general public exposure (in Poland: 75 µT). Magnetic flux density in stations is significantly higher and can exceed permissible value for 8 hours workers' exposure (in Poland: 200 µT). The level of magnetic filed in the rooms neighbouring to transformers stations depends on an load of transformer, kind of transformer power output (cables or buses), and distance of cables or buses from walls and ceilings of station. The data from operators of city electrical system shows differences in current loads of transformers: from 50 A for all transformers up to 460 A in case of transformers of 630 kVA nominal power. The differences in current loads result from changes in consumption of power depended on time of day or season of year and numbers of consumer of electric energy connected to a transformer station. Maximum phase current is usually (50-70%) of maximum output current. The increase in current from transformers and increase in produced magnetic field is possible in current technical system. Most often the phase load of transformers of 160-630 kVA nominal power is in the range of 50-150 A. Various constructional and architectural solutions (dimensions of transformer stations and distribution rooms of low voltage, distance of electrical equipment from working and living rooms) influence on a level of magnetic filed in the vicinity of electrical devices. Usually, the height of transformer station is in the range of 3-4 m. The buses or cables of low voltage connected transformer with switch box are located 0.5-1.7 m under ceiling. Sometimes cables are put on the wall. Exposure to magnetic field of low frequency in the rooms neighbouring to transformer stations is below permissible exposure for general public, nevertheless a level of magnetic field is significantly higher than in rooms in buildings without transformers. According to resolutions of European Parliament and standing of World Health Organisation, available measures to reduce a level of magnetic field should be undertaken. One of the most effective methods is close-up of cables to allow the self-compensation of magnetic fields produced by currents of different phases. This method in case of transformer stations can give 10 - fold decrease in magnetic field in the rooms neighbouring to transformers stations.
Źródło:
Biuletyn Wojskowej Akademii Technicznej; 2009, 58, 4; 125-137
1234-5865
Pojawia się w:
Biuletyn Wojskowej Akademii Technicznej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Monitoring of brain tumor evolution using impedance tomography
Obserwacja rozwoju guza mózgu przy użyciu tomografii impedancyjnej
Autorzy:
Ostanina, K.
Dědková, J.
Powiązania:
https://bibliotekanauki.pl/articles/159002.pdf
Data publikacji:
2011
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
tomografia impedancyjna
pole elektryczne
pole elektromagnetyczne
elektryczna tomografia impedacyjna
electrical impedance tomography
biological tissue
magnetic field
conductivity
electric field
electrical capacitance tomography
magnetic flux density
voltages
magnetic resonance
Opis:
The paper proposes new technique for a non-invasive monitoring of local changes in a biological tissue based on impedance tomography. The injected current causes apart of the electric field inside the given object also the magnetic field. The new algorithm for conductivity image reconstruction, which uses the internal current information with respect to corresponding boundary conditions and one component of an external magnetic field, was developed. The internal conductivity distribution obtained using the proposed method is compared with those using conventional methods based on Electrical Impedance Tomography.
Artykuł proponuje nową metodę nieinwazyjnej obserwacji lokalnych zmian tkanki biologicznej opartej na tomografii impedancyjnej. Wprowadzony prąd powoduje oprócz pola elektrycznego wewnątrz danego obiektu także powstanie pola magnetycznego. Został opracowany nowy algorytm do rekonstrukcji obrazu przewodności wykorzystujący informację od wewnętrznego prądu, odpowiednio do warunków brzegowych i jedną składową zewnętrzną pola magnetycznego. Rozkład wewnętrznej przewodności otrzymany przy użyciu proponowanej metody porównano z wynikami konwencjonalnych metod opartych na Elektrycznej Tomografii Impedancyjnej.
Źródło:
Prace Instytutu Elektrotechniki; 2011, 252; 87-92
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Electro-magnetohydrodynamic two fluid flow of ionized-gases with hall and rotation effects
Autorzy:
Linga Raju, T.
Powiązania:
https://bibliotekanauki.pl/articles/2174161.pdf
Data publikacji:
2021
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
pole magnetyczne
pole elektryczne
plazma
wymiana ciepła
magnetic field
electric field
immiscible flow
plasma
Hall effect
rotating frame
heat transfer
insulating plate
Opis:
An electro-magnetohydrodynamic (EMHD) two fluid flow and heat transfer of ionized gases through a horizontal channel surrounded by non-conducting plates in a rotating framework with Hall currents is investigated. The Hall effect is considered with an assumption that the gases are completely ionized and the strength of the applied transverse magnetic field is strong. The governing equations are solved analytically for the temperature and velocity distributions in two fluid flow regions. The numerical solutions are demonstrated graphically for various physical parameters such the Hartmann number, Hall parameter, rotation parameter, and so on. It was noticed that an increment is either due to the Hall parameter or the rotation parameter reduces the temperature in the two regions.
Źródło:
International Journal of Applied Mechanics and Engineering; 2021, 26, 4; 128--144
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ocena przydatności metod fizycznych do zwalczania przechowalniczych chorób bulw ziemniaka
Feasibility study of physical methods for treating potato bulb diseases resulting from storage
Autorzy:
Marks, N.
Lipiec, J.
Jakubowski, T.
Powiązania:
https://bibliotekanauki.pl/articles/286534.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Inżynierii Rolniczej
Tematy:
promieniowanie mikrofalowe
pole elektryczne
pole magnetyczne
choroba przechowalnicza
odmiana
ziemniak
microwave radiation
electric field
magnetic field
diseases resulting from storage
species
potato
Opis:
W pracy dokonano oceny przydatności wybranych metod fizycznych do zwalczania przechowalniczych chorób bulw ziemniaka jak rizoktonioza i parch zwykły. Badania prowadzono w latach 2002 – 2004 na trzech odmianach ziemniaków: Salto, Drop i Irga. Poddanie bulwy ziemniaka działaniu impulsowego pola elektrycznego, ekspozycji na działanie pola magnetycznego czy stosowanie promieni mikrofalowych redukuje rozwój i populację niektórych bakterii oraz grzybów charakterystycznych dla chorób przechowalniczych ziemniaków. Oceniając wpływ badanych czynników na stopień porażenia bulw rizoktoniozą i parchem zwykłym, stwierdzono pozytywny ich wpływ (poprawę zdrowotności bulw) w przypadku rizoktoniozy i negatywny wpływ w stosunku do kontroli w przypadku parcha zwykłego. Przedstawione rezultaty wskazują na celowość dalszych badań w tym zakresie.
The paper provides a feasibility study of selected physical methods for treating potato bulb diseases resulting from storage, such as rhizoctonia and common scab. The study was carried out between 2002 and 2004 on three potato species: Salto, Drop and Irga. Subjecting a potato bulb to pulsating electric field, exposure to magnetic field and application of microwaves inhibits growth of some bacteria, fungus and development of diseases typical for stored potatoes. While estimating the effect of studied factors on the extent of occurrence of rhizoctonia and common scab in potato bulbs, they have been found positive (improvement in bulb health) in case of rhizoctonia, and negative in relation to control, in case of the common scab. The results demonstrated indicate that it is quite reasonable to further investigate this issue.
Źródło:
Inżynieria Rolnicza; 2005, R. 9, nr 7, 7; 169-175
1429-7264
Pojawia się w:
Inżynieria Rolnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Unsteady electro-magneto hydrodynamic flow and heat transfer of two ionized fluids in a rotating system with Hall currents
Autorzy:
Raju, T. Linga
Rao, B. Venkat
Powiązania:
https://bibliotekanauki.pl/articles/2174167.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
transfer ciepła
przepływ nieustalony
plazma
pole magnetyczne
pole elektryczne
unsteady flow
magnetic field
electric field
immiscible flow
plasma
Hall effect
rotating frame
heat transfer
insulating plate
Opis:
An unsteady flow and heat transmission of ionized gases via a horizontal channel enclosed by non-conducting plates in a rotating framework with Hall currents is examined using electro-magnetohydrodynamic (EMHD) two-fluid heat flow. The Hall current impact is taken into account by assuming that the gases are totally ionized, the applied transverse magnetic field is very strong. For temperature and velocity distributions in two-fluid flow regions, the governing equations are solved analytically. For numerous physical parameters such as the Hartmann number, Hall parameter, rotation parameter, viscosity ratio, and so on, numerical solutions are visually displayed. It was discovered that an increase in temperature in the two regions is caused by the thermal conductivity ratio. It was also realized that an increase in rate of heat transfer coefficient at the plates is caused by either the Hartman number or the Hall parameter.
Źródło:
International Journal of Applied Mechanics and Engineering; 2022, 27, 1; 125--145
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Narażenie na pole elektromagnetyczne w przestrzeni pracy podczas użytkowania systemów elektroenergetycznych i elektrycznych instalacji zasilających prądu przemiennego w energetyce : metoda pomiaru pola elektromagnetycznego in situ – wymagania szczegółowe
Exposure to the electromagnetic field in the work space during the use of electricity and electric installations of alternating current in power engineering : the method of in situmeasurements of electromagnetic field –specific requirements
Autorzy:
Szuba, M.
Hasiec, I.
Papliński, P.
Śmietanka, H.
Zajdler, K
Zmyślony, M.
Gryz, K.
Karpowicz, J.
Powiązania:
https://bibliotekanauki.pl/articles/138452.pdf
Data publikacji:
2016
Wydawca:
Centralny Instytut Ochrony Pracy
Tematy:
elektroenergetyczne linie wysokiego napięcia
rozdzielnie elektroenergetyczne
instalacje elektroenergetyczne
pole elektryczne
pole magnetyczne
pomiary pola elektromagnetycznego
metoda rekomendowana
środowisko pracy
bezpieczeństwo i higiena pracy
high voltage power lines
high voltage switchyards
electric power installations
electric field
magnetic field
electromagnetic field measurements
recommended method
working environment
occupational safety and health
Opis:
Pole elektromagnetyczne (pole-EM) występuje w otoczeniu wszystkich instalacji i urządzeń zasilanych energią elektryczną, jest więc również nierozerwalnie związane z przesyłaniem energii elektrycznej przez sieć elektroenergetyczną, tworzoną głównie przez linie i rozdzielnie elektroenergetyczne: najwyższych, wysokich, średnich i niskich napięć, w których otoczeniu może występować pole-EM stref ochronnych. Obiekty takie zostały wymienione wśród typowych źródeł pola-EM jako „systemy elektroenergetyczne i elektryczna instalacja zasilająca” w rozporządzeniu Ministra Rodziny, Pracy i Polityki Społecznej z dnia 29 czerwca 2016 r. w sprawie bezpieczeństwa i higieny pracy przy pracach związanych z narażeniem na pole-EM (DzU 2016, poz. 950, zm. poz. 2284; zał. 1., poz. 2.). W związku z tym, warunki narażenia pracujących w otoczeniu urządzeń lub instalacji sieci elektroenergetycznych wymagają okresowej kontroli, zgodnie z wymaganiami określonymi w rozporządzeniu Ministra Zdrowia z dnia 2 lutego 2011 r. w sprawie badań i pomiarów czynników szkodliwych dla zdrowia w środowisku pracy, w którym określono, że powinna być ona wykonana „zgodnie z metodami określonymi w Polskich Normach, a w przypadku braku takich norm, metodami rekomendowanymi i zwalidowanymi” (DzU 2011, poz. 166). Celem takiej kontroli jest rozpoznanie zagrożeń elektromagnetycznych w przestrzeni pracy i podjęcie odpowiednich środków ochronnych (DzU 2016, poz. 950, zm. 2284). Ponieważ metody pomiarów pola-EM odpowiednie do realizacji tych wymagań prawa pracy nie są obecnie znormalizowane, celem przeprowadzonych badań było opracowanie metody rekomendowanej do pomiaru parametrów pola-EM in situ w przestrzeni pracy, podczas użytkowania sieci elektroenergetycznych. Rekomendowana metoda pomiarów została opracowana na podstawie przeglądu: parametrów konstrukcyjnych i elektrycznych infrastruktury energetycznej użytkowanej w Polsce, przeglądu danych literaturowych oraz wyników badań własnych wykonanych przez autorów w kilkuset obiektach elektroenergetycznych (najwyższych, wysokich, średnich i niskich napięć) o zróżnicowanej strukturze geometrycznej i funkcjonalnej, użytkowanych na terenie całego kraju. Przeprowadzone pomiary obejmowały pomiary wartości skutecznych natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych wg procedur określanych jako praca na potencjale. Przeprowadzone badania obejmowały pomiary wartości skutecznej natężenia pola elektrycznego i natężenia pola magnetycznego w przestrzeni pracy, z wyłączeniem narażeń występujących podczas prac wykonywanych według procedur określanych jako praca na potencjale. Pomiary obejmowały następujące obiekty prądu przemiennego użytkowane w ramach krajowego systemu elektroenergetycznego: napowietrzne i wnętrzowe rozdzielnie elektroenergetyczne o napięciach znamionowych (110 ÷ 750) kV oraz linie elektroenergetyczne o napięciach znamionowych (110 ÷ 400) kV, określanych jako wysokie lub najwyższe napięcia (WN lub NN); linie elektroenergetyczne niskiego lub średniego napięcia (nn lub SN) o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); rozdzielnie i transformatory nn lub SN o napięciach znamionowych (0,4 ÷ 110) kV (z wyłączeniem obiektów o napięciu 110 kV, zaliczanym do WN); generatory prądu wraz z torami prądowymi oraz aparaturą łączeniową i pomiarową o mocach powyżej 1 MW; instalacje potrzeb własnych na stacjach elektroenergetycznych; trójfazowe instalacje przemysłowe. Na podstawie wyników przeprowadzonych badań wykazano, że podczas użytkowania wspomnianych elementów sieci elektroenergetycznej są wykorzystywane prądy przemienne o częstotliwości 50 Hz i o stabilnym napięciu charakterystycznym dla jej poszczególnych obiektów, a obciążeniach prądowych zmieniających się w znacznym stopniu (o kilkaset procent), zależnie od zapotrzebowania odbiorców na energię elektryczną. W związku z tym, zarekomendowano metodę pomiarów, która obejmuje pomiar wartości skutecznej (RMS) natężenia pola elektrycznego i natężenia pola magnetycznego, których wyniki są oceniane bezpośrednio w odniesieniu do limitów narażenia, które określono w prawie pracy w stosunku do wartości równoważnych takich parametrów narażenia. W metodzie określono również zasady: przygotowania pomiarów i aparatury pomiarowej, wyboru punktów pomiarowych, wyznaczania zasięgu stref ochronnych oraz dokumentowania wyników pomiarów, a także warunki klimatyczne wykonywania pomiarów. Omówiono również najistotniejsze źródła niepewności wyników pomiaru pola-EM przy omawianych urządzeniach elektroenergetycznych.
Electromagnetic field (EMF) occurs around all the installations and equipment powered by electricity, so it is also inextricably linked to the transmission of electricity through the power grid, created mainly by the power lines and switchyards of the highest, high, medium and low voltage. In their vicinity EMF of protection zones may occur. Such installations have been listed among the common sources of EMF as a "power systems and electrical power supply installation" in the Regulation of the Minister of Family, Labour and Social Policy on health and safety at work related to exposure to EMF(OJ 2016 item. 950, est. 1, pos. 2). The refore, the exposure conditions of workers in the vicinity of equipment or installation of power grids require periodic inspections in accordance with the requirements of the Regulation of the Minister of Health on the tests and measurements of health hazard factors in the working environment (Regulation ...., OJ 2011, pos. 166), which should be done "in accordance with the methods set out in Polish standards, in the absence of such standards, using recommended and validated methods". The purpose of such inspection is to identify the electromagnetic hazards in work space and take appropriate protective measures (OJ 2016 pos. 950). Because the methods of EMF measurement adequate to meet the requirements of labour law are currently not standardized, the objective of conducted research was to develop a method recommended for measuring parameters of the EMF in situ in the work space during the use of electricity networks. The recommended method of measurement was developed on the basis of the review of design and electrical parameters of energy infrastructure in Poland, the review of literature and own research performed by the authors in hundreds of power facilities (the highest, high, medium and low voltage)and installations of various geometrical and functional structures used in the whole country. The performed research included measurements of RMS value of electric field and magnetic field strength in the work space, with the exception of exposures occurring during the work performed according to procedures known as live-line work. The measurements included the following objects used in the national electricity grid: electrical switchyards with nominal voltage from 110 kV to 750 kV (outdoor and indoor); power lines of high voltage (HV) with nominal voltage from 110 kV to 400 kV; power lines of low or medium voltage (LV or MV) with rated voltage of 0.4 kV to 110 kV (with the exception of 110 kV); switchyards, LV or MV switchboards and transformers; generators with bus bars, cables etc., current transformers, switchgear and measuring equipment with capacity exceeding 1 MW, installations of own needs on electrical substations, three-phase alternating current industrial installations. On the basis of the results of the research it was demonstrated that during the use of these elements of the power grid alternating currents with a frequency of 50 Hz are used, with a stable voltage characteristic of the individual objects and the load current changing significantly (by several hundred percent), depending on customers’ demand for electricity. The measurement method was recommended which involves measuring the RMS value of electric field strength and magnetic field strength, which results are evaluated immediately with respect to the exposure limits set in the labour law to the equivalent value of such exposure parameters. The method also describes principles: measurements and measurement devices preparation, choice of measurement points, determining the ranges protection zones and document measurement results, as well a climatic conditions of measurements. It also discusses the most important sources of uncertainty of results of EMF measurement near discussed power devices.
Źródło:
Podstawy i Metody Oceny Środowiska Pracy; 2016, 4 (90); 91-150
1231-868X
Pojawia się w:
Podstawy i Metody Oceny Środowiska Pracy
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-13 z 13

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies