Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "power plant efficiency" wg kryterium: Temat


Wyświetlanie 1-7 z 7
Tytuł:
Cooling water flow influence on power plant unit performance for various condenser configurations setup
Autorzy:
Dobkiewicz-Wieczorek, Ewa
Powiązania:
https://bibliotekanauki.pl/articles/2091367.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cooling water
power plant efficiency
cooling water flow control
CHP plant
efficiency
Opis:
This paper presents the influence of cooling water regulation on power plant net efficiency. It was examined whether, for the non-nominal low-pressure turbine load, it is justified to reduce the cooling water pump load, and how it would affect the unit net efficiency. Calculations for two types of power units were carried out: with condensing and extraction-condensing turbine. The tested condensing power plant consists of three surface condensers. The calculation included four condensers’ connections set up on the cooling water side to check how the cooling water system pressure drop affects the net unit performance. The result has confirmed that implementing serial connection decreases net efficiency when cooling water flow regulation is used, but the mixed connection should be applied when pump load is not controlled. It was proved that the cooling water flow control gives a profit for both units. Net efficiency for combined heat and power plant can be improved by 0.1–0.5 pp, the gain is remarkable below 60% of the low-pressure turbine part load. Flow control implementation in the unit with condensing turbine water control gives a similar profit just below 80% of the turbine load. Next, an influence of the additional limitations of a cooling water system (minimal total pump head, cooling tower) affecting the feasibility of implementing the water control has been considered. Applying a multi-cell forced draft cooling tower does not have a significant impact on results, but when a natural draft cooling tower is used, the flow control range is strongly reduced.
Źródło:
Archives of Thermodynamics; 2022, 43, 1; 141--167
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Selected aspects of the choice of live steam pressure in PWR nuclear power plant
Autorzy:
Laskowski, Rafał
Smyk, Adam
Jurkowski, Romuald
Ancé, Julien
Wołowicz, Marcin
Uzunow, Nikołaj
Powiązania:
https://bibliotekanauki.pl/articles/2134928.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
live steam
pressure
efficiency
power output
nuclear power plant
nuclear
power
plant
performance
entropy balance
Opis:
In commercially available generation III and III+ PWR (pressurized water reactor) reactors, pressure of steam produced in steam generators varies in a relatively wide range from 5.7 to 7.8 MPa. Therefore, it is important to ask which value of steam pressure should be used for a specific unit, taking into account different location conditions, the size of the power system and conditions of operation with other sources of electricity generation. The paper analyzes the effect of steam pressure at the outlet of a steam generator on the performance of a PWR nuclear power plant by presenting changes in gross and net power and efficiency of the unit for steam pressures in the range of 6.8 to 7.8 MPa. In order to determine losses in the thermal system of the PWR power plant, in particular those caused by flow resistance and live steam throttling between the steam generator and the turbine inlet, results concerning entropy generation in the thermal system of the power plant have been presented. A model of a nuclear power plant was developed using the Ebsilon software and validated based on data concerning the Olkiluoto Unit 3 EPR (evolutionary power reactor) power plant. The calculations in the model were done for design conditions and for a constant thermal power of the steam generator. Under nominal conditions of the Olkiluoto Unit 3 EPR power unit, steam pressure is about 7.8 MPa and the steam dryness fraction is 0.997. The analysis indicates that in the assumed range of live steam pressure the gross power output and efficiency increase by 32 MW and 0.735 percentage point, respectively, and the net power output and efficiency increase by 27.8 MW and 0.638 percentage point, respectively. In the case of all types of commercially available PWR reactors, water pressure in the primary circuit is in the range of 15.5−16.0 MPa. For such pressure, reducing the live steam pressure leads to a reduction in the efficiency of the unit. Although a higher steam pressure increases the efficiency of the system, it is necessary to take into account the limitations resulting from technical and economic criteria as well as operating conditions of the primary circuit, including the necessary DNBR (departure from nucleate boiling ratio) margin. For the above reasons, increasing the live steam pressure above 7.8 MPa (the value used in EPR units that have already been completed) is unjustified, as it is associated with higher costs of the steam generator and the high-pressure part of the turbine.
Źródło:
Archives of Thermodynamics; 2022, 43, 3; 85--109
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badanie efektowności turbin wiatrowych dużej mocy
Research studies on the efficiency of wind turbine generators
Autorzy:
Szczyrba, T.
Boczar, T.
Powiązania:
https://bibliotekanauki.pl/articles/159046.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Elektrotechniki
Tematy:
turbiny wiatrowe
elektrownie wiatrowe
sprawność
wydajność
efektywność
wind turbine
efficiency
power curve
wind power plant
generator
Opis:
Podstawowym celem przeprowadzonych badań, było określenie wpływu zmian gęstości powietrza atmosferycznego na wyniki obliczeń wskaźników charakteryzujących efektywność elektrowni wiatrowych. Przy czy założono, że efektywność opisuje wielkość energii elektrycznej wyprodukowanej w określonym przedziale czasowym, przy istniejących warunkach atmosferycznych dla danej lokalizacji i przy uwzględnieniu jakości wyprodukowanej energii oraz rzeczywistej sprawności podzespołów prądotwórczych instalacji wiatrowych i ich układów sterowania. W części opisowej scharakte-ryzowano zastosowane urządzenia pomiarowe, usytuowanie mierników i sposób ich kalibracji oraz podstawowe zalecenia dotyczące metodyki wykonywania pomiarów wartości temperatury, ciśnienia oraz wilgotności powietrza atmosferycznego. Natomiast w części wynikowej przedstawiono wykresy obrazujące wpływ zarejestrowanych parametrów atmosferycznych i obliczonej na ich podstawie gęstości powietrza na przebiegi empirycznej krzywej mocy oraz na wartości rzeczywistej sprawności.
The primary objective of the research studies was to determine the impact of the air density changes on the calculation results of indicators characterizing the efficiency of a wind power plant. The equipment used for measuring purposes, location of metres and their calibration methods were characterized in the descriptive part of the article. Additionally, basic recommendations on the methodology of measuring the ambient air values of temperature, pressure and humidity. Wherein, it was assumed that the efficiency is being described by the electric force generated in a specified period of time, under existing weather conditions for the given location, taking into account the quality of the generated energy and the real efficiency of components of the wind turbine generators and their control systems. In the part of the describing the results, graphs showing the impact of the recorded atmospheric parameters on the courses of empirical power curve and the real efficiency value were presented.
Źródło:
Prace Instytutu Elektrotechniki; 2013, 261; 97-104
0032-6216
Pojawia się w:
Prace Instytutu Elektrotechniki
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Studying the Efficiency of Treatment Model Mixtures of Petroleum Products with the Modified Sorbent Made of Ash-and-Slag During Dynamic Sorption
Autorzy:
Korotkova, Tatyana Germanovna
Bushumov, Svyatoslav Andreevich
Ksandopulo, Svetlana Yurevna
Solonnikova, Nataliya Vladimirovna
Powiązania:
https://bibliotekanauki.pl/articles/123373.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
ash and slag
thermal power plant
sorbent
sorption dynamics
efficiency
petroleum products
extraction
Opis:
Experimental studies on the dynamic sorption of model mixtures containing petroleum products were performed. The subject of the study was the modified sorbent from the ash-and-slag wastes accumulated in the ash dump of the Novocherkassk State District Power Plant (SDPP) (Russia, Novocherkassk, Rostov Region), obtained using the method of ash removal. The quantity of the sorbent for each model solution was fixed at 5.0 g. The model solutions in the amount of 1 dm3 were passed through a column filled with the modified sorbent at constant filtration rate w = const with filtrate takeout of 0.1 dm3/min. The pH value of the solution, which is advisable for extracting petroleum products, was determined experimentally. For this purpose, the model solutions, containing 100 mg/dm3 of petroleum products with pH = 1.65, 4.01, 6.86, 8.12, 9.18, and 11.34, were prepared. The optimum pH value of the solution was considered pH = 7.5. The content of petroleum products in the filtrate in all experiments was determined using IR spectrometry. The working range of water pollution with petroleum products was determined on a series of model solutions containing petroleum products in the range between 0.5 and 10 mg/dm3 with the increment of 0.5, between 10 and 100 mg/dm3 with the increment of 10, and between 100 and 1,000 mg/dm3 with the increment of 100. The maximum extraction of petroleum products from the solution was 88.23%. The applicability of the Henry’s law to the range of petroleum products concentrations in the filtrate of 50 mg/dm3 was confirmed. The adsorption equilibrium constant (Henry’s law constant) was determined experimentally. The effect of the natural freshwater matrix on the degree of petroleum products extraction was studied; no significant effect on petroleum products sorption was found. A conclusion was made that the sorbent can ensure the efficiency of water purifying from petroleum products of no less than 85% in the range of pollution between 5 and 300 mg/dm3.
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 202-209
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Numerical thermodynamic optimization of supercritical coal fired power plant with support of IPSEpro software
Autorzy:
Elsner, W.
Kowalczyk, Ł.
Marek, M.
Powiązania:
https://bibliotekanauki.pl/articles/240118.pdf
Data publikacji:
2012
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
optymalizacja termodynamiczna
siłownia nadkrytyczna
symulacja
wydajność
efficiency
simulation
supercritical power plant
thermodynamic optimization
Opis:
The paper presents a thermodynamic optimization of supercritical coal fired power plant. The aim of the study was to optimize part of the thermal cycle consisted of high-pressure turbine and two chosen high-pressure feed water heaters. Calculations were carried out using IPSEpro software combined with MATLAB, where thermal efficiency and gross power generation efficiency were chosen as objective functions. It was shown that the optimization with newly developed framework is sufficiently precise and its main advantage is the reduction of computation time on comparison to the classical method. The calculations have shown the tendency of the increase in efficiency, with the rise of a number of function variables.
Źródło:
Archives of Thermodynamics; 2012, 33, 3; 101-110
1231-0956
2083-6023
Pojawia się w:
Archives of Thermodynamics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Efektywność ekonomiczna hybrydowej mikroinstalacji OZE
Efficiency of hybrid microinstallation with renewable energy sources
Autorzy:
Bogalecka, Elżbieta
Krzemiński, Zbigniew
Powiązania:
https://bibliotekanauki.pl/articles/266952.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
mikroelektrownia hybrydowa
efektywność
moc bierna
czas zwrotu nakładów
small hybrid power plant
efficiency
reactive power
payback period
Opis:
W artykule przedstawiono warunki pracy mikroelektrowni hybrydowej zainstalowanej w małej firmie mieszczącej się na terenie przemysłowym. Pokazano strukturę i parametry elektrowni składającej się z paneli fotowoltaicznych i elektrowni wiatrowej. Przeanalizowano odbiorniki energii oraz warunki pobierania mocy biernej. Dla wybranego okresu czasu pokazano zużycie oraz produkcję energii elektrycznej i energię zużytą na potrzeby firmy oraz oddaną do sieci. Na podstawie cen energii określono czas zwrotu nakładów inwestycyjnych już poniesionych. Zbadano celowość modernizacji przekształtników w elektrowni polegającej na wymianie tranzystorów IGBT na tranzystory SiC i celowość zakupu magazynu energii. Wykazano, że poniesione nakłady zwrócą się po ponad 10 latach. Nieuchronny wzrost cen energii spowoduje skrócenie czasu zwrotu nakładów inwestycyjnych do mniej niż 10 lat.
The article presents the working conditions of a hybrid micro-plant installed in a small company located in an industrial area. The structure and parameters of a power plant consisting of photovoltaic panels and a wind power plant are shown. The energy receivers and the conditions of reactive power consumption were analyzed. For the selected period of time, the consumption and production of electricity and energy consumed for the needs of the company and sent to the network were shown. On the basis of energy prices, the payback period of investment outlays was determined. When examining economic efficiency, usually only active power is taken into account. The analysis takes into account the possibility of reactive power compensation by wind turbine and solar power converters. The purposefulness of modernization of converters in a power plant relying on the replacement of IGBT transistors by SiC transistors and the purposefulness of purchasing an energy storage was examined. It has been shown that the expenditure incurred will pay back after more than 10 years. The inevitable increase in energy prices will shorten the payback period of investment outlays to less than 10 years.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 63; 19-22
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Lusatian lignite - sustainable mining to meet future climate change policy
Lignit z terenów łużyckich - zrównoważona eksploatacja zgodnie z przyszłą polityką zmian klimatycznych
Autorzy:
Rolland, W.
Ketzmer, W.
Powiązania:
https://bibliotekanauki.pl/articles/348861.pdf
Data publikacji:
2009
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Wydawnictwo AGH
Tematy:
niezawodność
otwartość
skuteczność
inwestycje przyszłościowe
koncepcja przyszłego rozwoju kopalni odkrywkowych i elektrowni
technologia CCS
region energetyczny Łużyc i Szprewaldu
reliability
opennes
efficiency
future-oriented investments
future mine and power plant development concept
CCS technology
energy region Lausitz/Spreewald
Opis:
For Vattenfall, it is an important aspect of their entrepreneurial activity to make lignite sustainable in a climate-political perspective, in particular with regard to the economic development of the region. Under the headline "Innovative Energy Region Lausitz-Spreewald" representatives of the company, educational and other institutions and last but not least of policy are dedicated to a future-oriented development of Lusatia. An essential element of the long-term mining and power plant concept is the development of the CCS (Carbon Capture and Storage) - technology. Around 2020 this technology should be available for low CO2 emission power generation based on lignite in commercial scale. Apart from climate-neutral lignite-based power generation, the expansion of the energy-economic know-how and the use of other energy sources are among others important topics. This also includes the use of wind energy on recultivation areas, generation of biogas from biomass for power generation and the capture of CO2 by microalgae. Of great importance is also the "low-energy housing" topic, in particular for future resettlement locations. Lignite has its place in the energy mix, because first of all lignite is a chance for the future, especially in Lusatia.
Głównym aspektem działalności przedsiębiorczej koncernu Vattenfall, zwłaszcza w odniesieniu do rozwoju regionu, jest zapewnienie klimatyczno-politycznej perspektywy dla węgla brunatnego. Pod hasłem "Innowacyjny Region Energetyczny Łużyce-Spreewald" chodzi przedstawicielom koncernu, placówkom edukacyjnym, instytucjom i wreszcie też sferom politycznym o ustalenie kierunku przyszłego rozwoju Łużyc. Rozwój technologii CCS (Carbon, Capture and Storage) stanowi w tym ważną część składową długofalowej koncepcji górniczo-energetycznej. Około roku 2020 technologia ta ma być dostępna w skali przemysłowej do wytwarzania energii elektrycznej z węgla brunatnego przy zminimalizowanej emisji CO2. Ważnymi tematami oprócz neutralnej klimatycznie produkcji prądu z węgla brunatnego są mi in. rozwijanie energetyczno-ekonomicznego know-how oraz wykorzystanie innych nośników energii. Do tych ostatnich zalicza się m.in. wykorzystanie energii wiatru na terenach objętych rekultywacją po eksploatacji węgla, pozyskiwanie biogazu z biomasy do wytwarzania prądu oraz wiązanie CO2 za pomocą mikroglonów. Duże znaczenie ma także tematyka "osiedli energooszczędnych", zwłaszcza dla przyszłych osiedli zastępczych, budowanych na przesiedlenia z terenów zajmowanych pod kopalnie. Węgiel brunatny zajmuje stałą pozycję w strukturze nośników energii, bowiem węgiel brunatny jest w pierwszym rzędzie szansą na przyszłość i to przede wszystkim dla Łużyc.
Źródło:
Górnictwo i Geoinżynieria; 2009, 33, 2; 401-408
1732-6702
Pojawia się w:
Górnictwo i Geoinżynieria
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies