- Tytuł:
- Selection of the best route for column configuration in an existing copper circuit
- Autorzy:
-
Can, N. Metin
Altun, Okan - Powiązania:
- https://bibliotekanauki.pl/articles/109679.pdf
- Data publikacji:
- 2019
- Wydawca:
- Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
- Tematy:
-
column flotation
sulphide ores
distribution of wash water
airflow rate
froth height - Opis:
- This study was aimed to utilize column flotation to obtain much cleaner concentrate in the Cu circuit. However, the numbers of equipment and the proper streams for column application should be the key for successful operation. Therefore, the effects of some operational parameters such as wash water rate, airflow rate and froth height were investigated on the streams of namely Cu first cleaner concentrate, Cu rougher concentrate and Cu third cleaner concentrate in terms of mineral recoveries and selectivity. Distribution of wash water rate to products was also determined by a tracer test method. Optimum operating conditions and accordingly performance of the column were determined by simulation studies. According to the results, the suitable streams for industrial scale flotation column are advised as the rougher concentrate and/or first cleaner concentrate. With series installation of columns, it is possible to obtain two different concentrates which include 22% Cu, 4% Zn and 17% Cu, 8% Zn without any decrease in overall recovery of plant.
- Źródło:
-
Physicochemical Problems of Mineral Processing; 2019, 55, 2; 552-564
1643-1049
2084-4735 - Pojawia się w:
- Physicochemical Problems of Mineral Processing
- Dostawca treści:
- Biblioteka Nauki