Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "line distance protection" wg kryterium: Temat


Wyświetlanie 1-3 z 3
Tytuł:
Distance protection with dynamic thermal line rating enhancement
Autorzy:
Staszewski, Ł.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410531.pdf
Data publikacji:
2012
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
overload
heat balance
Opis:
As the worldwide analysis of recent wide area cascading failures have shown, very often the main cause of blackout was mal-operation of the third zone of a distance protection relay. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection mal-function. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to controlled impedance encroachment.This paper proposes a new approach to enhance the distance protection relay operation by introducing a new blocking algorithm. The algorithm is based on Dynamic Thermal Line Rating (DTLR) idea to restrain relay from tripping when conditions in electrical power system and weather conditions allow for it.
Źródło:
Present Problems of Power System Control; 2012, 2; 73-84
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Thermal calculation for distance protection enhancement
Autorzy:
Staszewski, Ł
Rebizant, W
Powiązania:
https://bibliotekanauki.pl/articles/410608.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
dynamic thermal line rating
distance protection
power swing
third zone
Opis:
Worldwide analysis of recent wide area cascading failures has shown that very often their main cause was the mal-operation of the distance protection relay third zone. The load encroachment and power swing phenomena are the two dire problems to solve when dealing with the third zone of distance protection. The vast number of blackouts could have been avoided or the consequences lowered if the distance relay had not operated due to impedance encroachment while there was no risk of further, continuous operation. This paper proposes a way to improve operation of the distance protection relay by introducing a new blocking algorithm that uses the Dynamic Thermal Line Rating (DTLR) to restrain relay from tripping when conditions in electrical power system allow for it.
Źródło:
Present Problems of Power System Control; 2013, 3; s. 83-94
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Study of the impact of 220 kV SISFCL on the distance protection for transmission line
Autorzy:
Luo, Y.
Shi, T.
Huang, L.
Powiązania:
https://bibliotekanauki.pl/articles/141728.pdf
Data publikacji:
2018
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
SISFCL
distance protection
EMTDC/PSCAD
220 kV transmission line
setting method
Opis:
As the most typical application of superconducting technology, the Saturated Iron core Superconducting Fault Current Limiter (SISFCL) is a kind of ideal high voltage limiter, which can achieve noticeable limiting endless stream and has wide application prospect. However, the selectivity and sensitivity of the distance protection (DP) in the high voltage transmission network would be affected by the impedance characteristics of SISFCL. For these problems, firstly the structure and the working principle of the SISFCL are introduced briefly. Secondly, the impact mechanisms of 220 kV SISFCL on the original distance protection for the transmission line (TL) are analyzed. Then two methods of eliminating influences are deduced from the previous analysis and an improved setting method based on SISFCL for distance protection is proposed. Finally, we used EMTDC/PSCAD software to build the 220 kV SISFCL and distance protection model in the transmission network. The simulation results demonstrate that the proposed setting strategy can effectively improve the selectivity and sensitivity of distance protection and provide a reference for the practical applications of SISFCL applied to the transmission line.
Źródło:
Archives of Electrical Engineering; 2018, 67, 1; 151-163
1427-4221
2300-2506
Pojawia się w:
Archives of Electrical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies