Tytuł:
Assessment of fatigue life of aluminized, coarse-grained MAR247 alloy supported by full-field ESPI measurements
Autorzy:
Kopec, Mateusz
Kukla, Dominik
Kowalewski, Zbigniew L.
Powiązania:
https://bibliotekanauki.pl/articles/2200834.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Mechaniki Teoretycznej i Stosowanej
Tematy:
fatigue development
damage
nickel alloys
electronic speckle pattern interferometry
Opis:
In this paper, fatigue performance of an aluminide layer coated, coarse-grained MAR247 nickel superalloy was monitored by using the full-field Electronic Speckle Pattern Interferometry (ESPI) method in the range of stress amplitude from 350MPa to 650MPa. It was found, that the ESPI method enables precise monitoring of the fatigue behaviour of coated MAR247 specimens since the area of potential failure was accurately indicated within the initial stage of fatigue damage development.
Źródło:
Journal of Theoretical and Applied Mechanics; 2022, 60, 4; 619--623
1429-2955
Pojawia się w:
Journal of Theoretical and Applied Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
The stress and strain distribution in X10CrMoVNb9-1 power engineering steel after long time degradation studied by the ESPI system
Autorzy:
Kopec, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/2173671.pdf
Data publikacji:
2022
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
damage
P91 steel
electronic speckle pattern interferometry
ESPI
optical measurements
szkoda
stal P91
elektroniczna interferometria plamkowa
pomiar optyczny
Opis:
Maintenance of assets and equipment in power plants is essential for their safety and is required to help the plant stay active. In this paper, the specimens manufactured from a pipe of X10CrMoVNb9-1 (P91) power engineering steel in the as-received state and after operating for 80 000 h at internal pressure of 8.4 MPa and temperature of 540ºC were subjected to tests using electronic speckle pattern interferometry (ESPI) under static loading of up to 2.5 kN. Such a procedure enables assessment of strain and stress distribution maps to compare material integrity in the as-received state and after exploitation in its elastic range. The measurements conducted showed no effect of long time operation on the mechanical response of P91 steel under the power installations conditions since the field strain distributions for each type of specimen were found to be similar.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2022, 70, 3; art. no. e141181
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies