Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "czujniki chemiczne" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Hydrogel-based chemical and biochemical sensors
Chemiczne i biochemiczne czujniki hydrożelowe
Autorzy:
Gerlach, Gerald
Powiązania:
https://bibliotekanauki.pl/articles/268315.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
hydrogels
swelling pressure
chemical sensors
hydrożele
ciśnienie pęcznienia
czujniki chemiczne
Opis:
Hydrogels are cross-linked polymer networks able to absorb or to release large amounts of water. The water uptake is associated with a considerable volume change but also with changes of optical properties like the refractive index. The swelling can be excited by a large spectrum of different physical (e.g. temperature, electrical voltage, magnetic field) and chemical factors (e.g. pH value, concentrations of chemical or biochemical species). The particular sensitivity can be adjusted by tayloring the composition of the hydrogel or via its functionalization. If the interaction between hydrogel and analyte to be measured is reversible then such hydrogels are becoming a promising candidate for miniaturized, cost-effective and inline-capable sensors.
Hydrożele są usieciowanymi sieciami polimerowymi zdolnymi do absorbowania lub uwalniania dużych ilości wody. Pobór wody wiąże się ze znaczną zmianą objętości, ale także ze zmianami właściwości optycznych, takich jak współczynnik załamania światła. Pęcznienie może być wzbudzane przez różne czynniki (np. temperaturę, napięcie elektryczne, pole magnetyczne) i czynniki chemiczne (np. pH, stężenie substancji chemicznych lub biochemicznych). Pożądaną czułość można uzyskać przez odpowiedni skład hydrożelu lub poprzez jego funkcjonalizację. Jeśli oddziaływanie między hydrożelem a analitem, który ma być zmierzony, jest odwracalne, wówczas takie hydrożele stają się obiecującym materiałem do budowy miniaturowych, ekonomicznie opłacalnych czujników.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 66; 15-19
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Process control of air stream deodorization from vapors of VOCs using a gas sensor matrix conducted in the biotrickling filter (BTF)
Kontrola procesowa dezodoryzacji strumienia powietrza z par LZO, przeprowadzonej w biofiltrze zraszanym, przy wykorzystaniu matrycy czujników gazowych
Autorzy:
Dobrzyniewski, Dominik
Szulczyński, Bartosz
Rybarczyk, Piotr
Gębicki, Jacek
Powiązania:
https://bibliotekanauki.pl/articles/27311562.pdf
Data publikacji:
2023
Wydawca:
Polska Akademia Nauk. Czasopisma i Monografie PAN
Tematy:
biofiltration
electronic nose
biotrickling filter
chemical sensors
sensor matrix
odorous compounds
biofiltracja
elektroniczny nos
biofiltr zraszany
czujniki chemiczne
matryca czujników
zanieczyszczenie powietrza
Opis:
This article presents the validity, advisability and purposefulness of using a gas sensor matrix to monitor air deodorization processes carried out in a peat-perlite-polyurethane foam-packed biotrickling filter. The aim of the conducted research was to control the effectiveness of air stream purification from vapors of hydrophobic compounds, i.e., n-hexane and cyclohexane. The effectiveness of hydrophobic n-hexane and cyclohexane removal from air was evaluated using gas chromatography as the reference method and a custom-built gas sensor matrix consisting of seven commercially available sensors. The influence of inlet loading (IL) of n-hexane and cyclohexane on the biotrickling filtration performance was investigated. The prepared sensor matrix was calibrated with use of two statistical techniques: Multiple Linear Regression (MLR) and Principal Component Regression (PCR). The developed mathematical models allowed us to correlate the multidimensional signal from the sensor array with the concentration of the removed substances. The results based on gas chromatography analyses indicated that the elimination efficiencies of n-hexane and cyclohexane reached about 40 and 30 g m-3 h-1, respectively. The results obtained using a gas sensor matrix revealed that it was possible not only to determine concentration reliably of investigated hydrophobic volatile organic compounds in the gas samples, but also to obtain results of a similar high level of quality as the chromatographic ones. A gas-sensor matrix proposed in this work can be used for on-line real-time monitoring of biofiltration process performance of air polluted with n-hexane and cyclohexane.
W artykule przedstawiono zasadność, celowość i sensowność zastosowania matrycy czujników gazowych do monitowania procesów dezodoryzacji powietrza prowadzonych w biofiltrze zraszanym (BTF) z wypełnieniem w postaci torf-perli-pianka poliuretanowa. Celem przeprowadzonych badań była kontrola procesowa skuteczności oczyszczania strumienia powietrza z par związków hydrofobowych, którymi były n-heksan i cykloheksan. Skuteczność usuwania hydrofobowego n-heksany i cykloheksanu z powietrza oceniono przy użyciu chromatografii gazowej jako techniki referencyjnej oraz skonstruowanej matrycy czujników gazowych składającej się z siedmiu komercyjnie dostępnych czujników. Zbadano wpływ obciążenia złoża (IL) n-heksanu i cykloheksanu na wydajności biofiltracji. Przygotowana matryca czujnikowa została skalibrowana z wykorzystaniem dwóch technik statystycznych: Multiple Linear Regression (MLR) oraz Principal Component Regression (PCR). Opracowane modele matematyczne pozwoliły skorelować wielowymiarowy sygnał z matrycy czujników ze stężeniem usuwanych substancji. Wyniki uzyskane na podstawie analiz chromatograficznych wykazały, że wydajność usuwania n-heksanu i cykloheksanu osiągnęły odpowiednio około 40 i 40 gm-3h-1. Wyniki uzyskane z wykorzystaniem matrycy czujników gazowych wykazały, że możliwe było nie tylko wiarygodne określenie stężeń badanych hydrofobowych lotnych związków organicznych w próbkach gazowych, ale również charakteryzowały się podobnie wysokim poziomem jakości jak wyniki chromatograficzne. Zaproponowana w tej pracy matryca czujników gazowych może być wykorzystana do monitorowania procesu biofiltracji powietrza zanieczyszczonego n-heksanem i cykloheksanem w czasie rzeczywistym.
Źródło:
Archives of Environmental Protection; 2023, 49, 2; 85--94
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies