Wyświetlanie 1-4 z 4
Tytuł:
Analysis of the Problem of False Fire Alarms Generated by Fire Alarm Systems in Poland and Other Selected Countries
Analiza problematyki fałszywych alarmów pożarowych generowanych przez systemy sygnalizacji pożarowej w Polsce i innych wybranych krajach
Autorzy:
Pietrzak, Michał
Chmiel, Michał
Feltynowski, Mariusz
Powiązania:
https://bibliotekanauki.pl/articles/35011322.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire alarm system
fire alarm
false alarm
fire detectors
system sygnalizacji pożarowej
alarm pożarowy
fałszywy alarm
czujka pożarowa
Opis:
Aim: The aim of this article is to discuss the issue of false fire alarms by presenting the most common causes of their occurrence and statistical data, along with the presentation of selected regulatory issues. The article also addresses the issue of minimizing false alarms and the means by which this can be accomplished. Introduction: Due to the fact that triggered fire alarms from fire alarm systems (SSP) initiate a number of triggers of fire protection equipment and can lead to the initiation of fire department actions, it is extremely important to correctly identify the report and confirm its authenticity. However, analysing the statistically available data, it should be noted that unfortunately – despite a number of security methods – false alarms still account for a large percentage of identified calls. This article presents selected false alarm issues from Poland and other countries, such as the United States of America, Germany, Denmark, the Czech Republic, the United Kingdom, Switzerland and Austria. Special attention was paid to statistics on the occurrence of false alarms, formal and legal regulations, causes of false alarms, and used detection elements, including their susceptibility to false reports, along with the methods to reduce them. Methodology: The article uses the results of the authors’ own analysis of the study, made on the basis of the available statistical data from incidents that have occurred, and technical and engineering knowledge of the components of fire alarm system. Conclusions: Analysing the available statistical data, it can be observed that the problem of false alarms is not disappearing. On the contrary – in many countries over the years it is increasing. An increasing percentage of reports from detection systems are false alarms. In addition, considering the available legal regulations, it can be observed that regulations related to false alarms currently focus only on regulating penalties for false alarm reports. Only in a few cases do they concern any other provisions. Nowadays, there are various available methods to protect installations from the occurrence of false alarms, but in order to use them correctly, it is essential that they are properly designed and installed by people with knowledge and experience in this area. Thus, according to the authors, it is reasonable to conclude that the basic requirement for these systems in terms of false fire alarms should be to provide opportunities for obtaining appropriate qualifications and competence among designers, installers and maintainers of SSP systems alike. Keywords: fire alarm system, fire alarms, false alarm, fire detectors.
Cel: Celem artykułu jest omówienie problematyki fałszywych alarmów pożarowych poprzez przedstawienie najczęstszych przyczyn ich występowania oraz danych statystycznych wraz z prezentacją wybranych zagadnień z zakresu regulacji prawnych. Praca porusza także kwestię minimalizacji liczby fałszywych alarmów oraz środków, jakimi może to zostać zrealizowane. Wprowadzenie: Z uwagi na fakt, że wywoływane alarmy pożarowe z systemów sygnalizacji pożarowej (SSP) inicjują szereg wysterowań urządzeń przeciwpożarowych oraz mogą prowadzić do inicjacji działań straży pożarnej, niezwykle istotne jest poprawne rozpoznanie zgłoszenia oraz potwierdzenie jego autentyczności. Jednakże, analizując statystycznie dostępne dane, stwierdzić należy, że niestety – pomimo szeregu metod zabezpieczających – fałszywe alarmy wciąż stanowią duży procent identyfikowanych zgłoszeń. W niniejszym artykule przedstawiono wybrane zagadnienia fałszywych alarmów z Polski i innych krajów, takich jak: Stany Zjednoczone Ameryki, Niemcy, Dania, Czechy, Wielka Brytania, Szwajcaria i Austria. Szczególną uwagę poświęcono statystykom występowania fałszywych alarmów, regulacjom formalnoprawnym, przyczynom powstawania fałszywych alarmów oraz wykorzystywanym elementom detekcyjnym, w tym ich podatności na fałszywe zgłoszenia wraz z metodami pozwalającymi na ich ograniczanie. Metodologia: W pracy wykorzystano wyniki własnej analizy autorów opracowania, dokonanej na podstawie dostępnych danych statystycznych z zaistniałych zdarzeń oraz wiedzę techniczną i inżynierską w zakresie elementów systemu sygnalizacji pożarowej. Wnioski: Analizując dostępne dane statystyczne, można zaobserwować, że problem fałszywych alarmów nie zanika, a wręcz przeciwnie – w wielu krajach na przestrzeni lat nasila się. Coraz większy odsetek zgłoszeń z systemów detekcyjnych stanowią fałszywe alarmy. Dodatkowo, uwzględniając dostępne regulacje prawne, można zauważyć, że przepisy powiązane z fałszywymi alarmami skupiają się obecnie jedynie na regulacji kar za zgłoszenia fałszywych alarmów. Jedynie w nielicznych przypadkach dotyczą one jakichkolwiek innych zapisów. Obecnie dostępne są różne metody pozwalające na zabezpieczanie instalacji przed pojawianiem się fałszywych alarmów, niemniej w celu poprawnego ich wykorzystania niezbędne jest właściwe ich zaprojektowanie i zainstalowanie przez osoby posiadające wiedzę i doświadczenie w tym zakresie. Zasadny jest więc w opinii autorów wniosek, że podstawowym wymaganiem w odniesieniu do tych systemów w aspekcie fałszywych alarmów pożarowych powinno być zapewnienie możliwości zdobycia odpowiednich kwalifikacji i kompetencji zarówno wśród projektantów, instalatorów, jak i konserwatorów instalacji SSP.
Źródło:
Safety and Fire Technology; 2022, 60, 2; 118-132
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania reakcji czujek pożarowych w różnych warunkach pożaru
Testing the Reaction of Fire Detectors in Various Fire Conditions
Autorzy:
Karwat, B.
Górski, A
Stańczyk, E.
Powiązania:
https://bibliotekanauki.pl/articles/373455.pdf
Data publikacji:
2015
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
bezpieczeństwo w budynkach
czujka pożarowa
zjawiska zwodnicze
systemy pożarowe
safety in buildings
fire detector
deceptive events
fire systems
Opis:
Cel: Celem przeprowadzonych badań było określenie przydatności czujek pożarowych do zastosowań w różnych warunkach pożaru, a także zweryfikowanie reakcji testowanych czujek na wymuszone zjawiska zwodnicze. W artykule przedstawiono przykłady najczęściej stosowanych czujek pożarowych, zakres ich stosowalności oraz technologię wykorzystywaną dla zabezpieczenia systemów sygnalizacji pożarowej przed działaniem zjawisk zwodniczych. W pracy omówiono wymagania stawiane nowoczesnym systemom sygnalizacji pożarowej. Wymieniono budynki oraz miejsca, w których istnieje obowiązek stosowania systemów sygnalizacji pożarowej zgodnie z obowiązującymi przepisami. Metody: Wykonano badania reakcji czujek pożarowych w różnych warunkach pożaru oraz zbadano odpowiedź detektorów na działanie zjawisk zwodniczych. W trakcie badań dokonywano pomiaru czynników fizykochemicznych oraz szybkości reakcji detektorów na zaistniałe wymuszenie. Do przeprowadzenia badań użyto czujek pożarowych powszechnie stosowanych w systemach sygnalizacji pożarowej przeznaczonych do różnych zastosowań. Czujki zostały rozmieszczone w odległości około 2 m od źródła symulowanego zagrożenia pożarowego. Przeprowadzono trzy testy, symulując: proces spawania, pożar tlący oraz pożar charakteryzujący się otwartym ogniem. Wykonując symulację zagrożenia pożarowego, dokonywano ciągłego pomiaru temperatury oraz stężenia dymu, a także reakcji czujek na zaistniałe wymuszenie. Wyniki: Badania dowiodły, że tylko czujki wyposażone w nowoczesną technologię dynamicznego dostosowania parametrów do zmieniających się zjawisk pożarowych nadają się do szerokiego zakresu zastosowań, ponieważ zarówno pozwalają na szybsze wykrycie zaistniałego zagrożenia pożarowego, jak i umożliwiają większą odporność na zjawiska zwodnicze w porównaniu z tradycyjnymi czujkami. Wnioski: Dzięki przeprowadzonym badaniom zweryfikowano, w jakim czasie dana czujka jest w stanie przejść ze stanu nieaktywnego w stan alarmu, dla określonych warunków pożarowych. Czas reakcji czujki na zaistniałe zagrożenie jest jednym z podstawowych parametrów określających użyteczność zastosowania danego detektora. Przeprowadzone badania umożliwiły określenie przydatności stosowania czujek dla różnych warunków pożarowych. Dzięki wykonanym badaniom trafniej można dobrać czujkę do konkretnego zastosowania oraz z większym prawdopodobieństwem uniknąć fałszywych alarmów generowanych przez zjawiska zwodnicze.
Aim: The purpose of the study was to determine the suitability of fire detectors for use in different fire conditions as well as verify the reaction of tested detectors to misleading trigger information. The paper describes examples of most frequently used fire detectors, their range of application and the technology harnessed to protect fire alarm systems from deceptive influences. The paper discussed modern fire alarm system requirements and the authors identified buildings, and locations, where installation of fire alarm systems is obligatory, in accordance with current regulations. Methods: The reaction of fire detectors was tested in various fire conditions as well as their response to deceptive influences. During tests, measurements were performed on the chemical reaction and detector response speed upon receipt of input signals. Research investigations were performed on fire detectors in common use for a range of different needs. The detectors were distributed at a distance of about 2 metres from the source of a simulated fire hazard. There were three simulated testing conditions including: a welding process, a smouldering fire and an open fire. During the fire threat simulation, the temperature and smoke concentration as well as the sensors’ activation response were constantly measured. Results: Studies have revealed that only detectors equipped with modern technology, dynamically adapted to deal with a varied range of fire incidents, are suitable for general application. Mainly, because they afford faster detection of potential threats as well as provide greater protection against false activation compared with conventional detectors. Conclusions: As a result of research it was possible to verify, for certain defined fire situations, the time lag for activation of a fire detector. The detector reaction time to a fire threat is one of the fundamental elements, which describe the usefulness of a given sensor. The study made it possible to determine the benefit in use of fire detectors for a range of different circumstances involving the threat of fire. As a result of research it is possible to select more accurately a detector for specific use and, with a higher level of probability, avoid false alarms caused by deceptive forces.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2015, 1; 57-64
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Reducing the Multi-Sensor Smoke Detectors Susceptibility to False Triggering
Ograniczenie podatności wielodetektorowych czujek pożarowych na mylne wzbudzenia
Autorzy:
Szafarczyk, Kalina
Powiązania:
https://bibliotekanauki.pl/articles/34670981.pdf
Data publikacji:
2022
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire detector
false alarms
detector operating modes
reduction of false triggering of fire detectors
czujka pożarowa
fałszywe alarmy
tryby pracy czujki
ograniczenie mylnych wzbudzeń czujek pożarowych
Opis:
Purpose: An assessment of the possibility of reducing the susceptibility of fire detectors to false alarms was carried out by: 1) analysing the impact of changing the operating modes of a multi-sensor detector on minimizing false alarms, and 2) verifying, using ANOVA tests, two hypotheses: either the settings or the sensitivity of the sensor affect the susceptibility of the detectors to false alarms. Project and methods: In order to assess the impact of false alarms on the operation of facilities equipped with a Fire Alarm System, a survey was conducted, directed at their administrators. A study of the fire detectors susceptibility to false alarms included placing the DTC-6046 multi-sensor detector in a closed test chamber and initiating the detector’s triggering by a deceptive agent. It was then observed whether the detector would initiate a fire alarm depending on different operating mode settings. The operation of the sensors was changed to interdependent, independent or coincidence work. Sensitivity settings of the sensors were changed from normal to increased by 20%, decreased by 20% or by 40%. An analysis using ANOVA test was conducted to verify which settings have a significant impact on minimising false alarms. Based on the results, example configuration guidelines were developed. Results: Based on the study, the following main results were formulated. The configuration least prone to false triggering is the one in which the sensors operate interdependently and the sensitivity is reduced by 40%. The highest number of false alarms was observed when sensitivity was increased by 20% with independent sensors and in coincidence, as well as for independent sensors working at normal sensitivity. Performing verification using ANOVA analysis of variance, the hypothesis that sensor settings have a statistically significant effect on minimising false alarms was rejected. Conclusions: There is a need to search for and implement ways to minimise false alarms of Fire Alarm Systems. The most common reason for false triggering of fire detectors are external factors that are not fire hazards (e.g. dust, dirt). The way of minimising false alarms is a proper setting of the detector operating modes (not often used in practice). The operating modes are based on changing the settings of sensor cooperation and detector sensitivity, where changing only the settings of the sensors does not result in such significant changes as changing the sensitivity of the detectors to increased or decreased compared to normal (result of ANOVA analysis).
Cel: Ocena możliwości ograniczania podatności czujek pożarowych na mylne wzbudzenia wykonana na podstawie: 1) analizy wpływu zmiany trybów pracy czujki wielodetektorowej na minimalizację fałszywych alarmów oraz 2) weryfikacji przy wykorzystaniu testów ANOVA dwóch hipotez: nastawy albo czułość sensorów wpływają na podatność czujek na mylne wzbudzenia. Projekt i metody: Aby ocenić wpływ fałszywych alarmów na funkcjonowanie obiektów, przeprowadzono ankietę, skierowaną do administratorów obiektów wyposażonych w system sygnalizacji pożarowej. Badania laboratoryjne podatności czujek pożarowych na mylne wzbudzenia polegały na umieszczeniu czujki wielodetektorowej DTC-6046 w zamkniętej komorze badawczej i próbie wzbudzenia jej czynnikiem zwodniczym. Obserwowano, czy czujka zainicjuje alarm pożarowy w zależności od różnych ustawień trybów pracy. Zmieniane były parametry określające pracę sensorów (współzależnie, niezależnie, w koincydencji) oraz ustawienia ich czułości z normalnej na podwyższoną o 20%, obniżoną o 20% bądź 40%. Przebadano 12 konfiguracji. Wyniki poddano analizie statystycznej metodą ANOVA, która pozwoliła na weryfikację, które ustawienia wpływają znacząco na minimalizację fałszywych alarmów. Na tej podstawie opracowane zostały przykładowe wytyczne konfiguracji. Wyniki: Na podstawie przeprowadzonych badań sformułowano poniższe główne ich wyniki. Najmniej podatna na fałszywe zadziałania jest konfiguracja, w której sensory działają współzależnie, a czułość jest obniżona o 40%. Najwyższą liczbą fałszywych alarmów charakteryzują się ustawienia czułości podwyższonej o 20% w przypadku sensorów niezależnych oraz będących w koincydencji, jak i dla sensorów niezależnych zadziałanie przy czułości normalnej. Przeprowadzenie weryfikacji, wykorzystując analizę wariancji ANOVA, pozwoliło odrzucić hipotezę, jakoby nastawy sensorów w istotnie statystyczny sposób wpływały na minimalizację fałszywych alarmów. Wnioski: Występuje konieczność poszukiwania i wdrażania sposobów minimalizowania fałszywych alarmów SSP. Najczęstszym powodem mylnego wzbudzania czujek pożarowych są czynniki zewnętrzne, niebędące zagrożeniem pożarowym (np. pył, kurz). Sposobem na ograniczenie tego zjawiska jest właściwe ustawienie trybów pracy czujki (stosowane w praktyce niezbyt często). Tryby pracy opierają się na zmianie ustawień współpracy sensorów oraz czułości czujki, gdzie zmiana tylko ustawień sensorów nie powoduje tak znaczących zmian, jak zmiana czułości czujek na podwyższoną bądź obniżoną w stosunku do normalnej (wynik analizy ANOVA).
Źródło:
Safety and Fire Technology; 2022, 60, 2; 164-174
2657-8808
2658-0810
Pojawia się w:
Safety and Fire Technology
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Detekcja dymu w wielkokubaturowych obiektach infrastruktury transportowe
Fire detection in large-volume transport infrastructure objects
Autorzy:
Klimczak, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/312005.pdf
Data publikacji:
2019
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
czujka pożarowa
czujki liniowe dymu
czujki zasysające
wideo detekcja pożaru
detekcja dymu
system sygnalizacji pożarowej
fire detector
smoke line detector
aspiration smoke detector
video fire detection
smoke detection
fire alarm system
Opis:
W artykule omówiono urządzenia (podzespoły wchodzące w skład systemu sygnalizacji pożarowej) służące do detekcji dymu, które można zastosować w celu zapewnienia bezpieczeństwa pożarowego wielkokubaturowych obiektów transportowych. W artykule omówiono zarówno powszechnie stosowane punktowe czujki dymu, czujki liniowe dymu, jak również bardziej zaawansowane technologicznie aspiracyjne czujki dymu (czujki zasysające) oraz czujki wykorzystujące nowoczesne technologie związane z wideo detekcją. Omówiono ponadto praktyczne możliwości w zastosowaniu konkretnych rozwiązań oraz ograniczenia w ich stosowaniu. Zaznaczono kierunki rozwoju systemów sygnalizacji pożarowej, w tym w zakresie detekcji dymu.
The article discusses the possible types of smoke detection devices that can be used to provide fire safety for large volume transport facilities. The article discusses both commonly used point smoke detectors or line detectors, as well as more technologically advanced aspiration smoke detectors (aspiration detectors) and detectors using video detection. Practical possibilities in the application of specific solutions and limitations in their application were also discussed. Development directions of fire alarm systems producers, including smoke detection, have been marked.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2019, 20, 12; 50-54
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies