Magnetizing current effect minimization in current transformers
Autorzy:
Dusza, D.
Rzepecki, B.
Powiązania:
https://bibliotekanauki.pl/articles/1813967.pdf
Data publikacji:
2013
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current transformer
value converter
ratio
error minimization
magnetizing current effect
current transformer's error
current measurement
Opis:
Magnetizing current effect minimization in current transformers is considered in this paper. Double-core current transformer operation is described in the following text. The influence of the magnetizing current, which is a significant element of current transformer's error, has been minimized in a new type of double-core current transformer connection. The accuracy evaluation of built double-core current transformer has been carried out according to obtained transformation precision.
Źródło:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały; 2013, 69, 33; 469--476
1733-0718
Pojawia się w:
Prace Naukowe Instytutu Maszyn, Napędów i Pomiarów Elektrycznych Politechniki Wrocławskiej. Studia i Materiały
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Differential protection with better stabilization for external faults
Zabezpieczenie różnicowe z lepszą stabilizacją dla zwarć zewnętrznych
Autorzy:
Solak, K.
Rebizant, W.
Powiązania:
https://bibliotekanauki.pl/articles/410581.pdf
Data publikacji:
2011
Wydawca:
Politechnika Wrocławska. Oficyna Wydawnicza Politechniki Wrocławskiej
Tematy:
current differential criterion
current transformer
fuzzy logic
saturation
Opis:
This paper presents a new differential protection scheme for transmission lines with application of fuzzy signal processing and support of phase comparison criterion. Traditional differential relays may have problems with proper classification of external faults with CT saturation. Better protection stabilization for such cases is obtained with support of fuzzy signal processing. In proposed solution the input signals as well as the standard percentage characteristic are fuzzified. The performance of presented fuzzy protection scheme has been tested with the signals generated with use of EMTP-ATP program and compared to the traditional solution.
W artykule zaprezentowano nowe zabezpieczenie różnicowe, w którym zastosowano rozmyte przetwarzanie sygnałów oraz dodatkowe kryterium porównawczo-fazowe. Proponowane zabezpieczenie jest bardziej odporne na zwarcia zewnętrzne z nasyceniem przekładników prądowych, co potwierdziły przeprowadzone testy. Proponowany algorytm testowany był na sygnałach pochodzących z symulacji w EMTP-ATP, a wyniki porównano ze standardowym przekaźnikiem różnicowym.
Źródło:
Present Problems of Power System Control; 2011, 1; 39-48
2084-2201
Pojawia się w:
Present Problems of Power System Control
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of the inductive current transformer derating for operation with distorted currents
Autorzy:
Kaczmarek, M.
Powiązania:
https://bibliotekanauki.pl/articles/201060.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
current transformer
distorted current
derating conditions
composite errors
transformer correction factor
accuracy class
Opis:
The aim of the paper is to present a new method for estimation of the CT (Current Transformer) rated primary current and / or load of the secondary winding derating levels for transformation of distorted current in relation to the rated values fixed for transformation of sinusoidal current. This ensures the values of the CT composite errors/transformer correction factors as resulting from its IEC 60044-1/IEEE C57.13 accuracy class in condition of distorted currents transformation.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2014, 62, 2; 363-366
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wykorzystanie nowoczesnych materiałów magnetycznych w konstrukcji magnetowodów
Application of modern magnetic materials to magnetic cores
Autorzy:
Kwiczala, J.
Rodoń, F.
Cholewa, S.
Powiązania:
https://bibliotekanauki.pl/articles/157370.pdf
Data publikacji:
2006
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
materiały amorficzne
rdzeń magnetyczny
przekładnik prądowy
amorphous materials
magnetic core
current transformer
Opis:
W artykule przedstawiono możliwości wykorzystania materiałów amorficznych w konstrukcji magnetowodów. Materiały te charakteryzują się bardzo dużą przenikalnością początkową oraz bardzo małą stratnością. Opisano możliwości zastosowania, np. w konstrukcji przekładników Ferrantiego, rdzeni kompozytowych - rdzeni złożonych z materiału tradycyjnego (żelazokrzem) o małej przenikalności i dużej indukcji nasycenia oraz materiału o dużej przenikalności magnetycznej i małej indukcji nasycenia (metglas).
The paper presents application of amorphous materials to construction of magnetic cores. These materials are characterized by very high initial relative permeability and very low losses. Application of composite cores to construction i.e of. the Ferranti earth-fault current transformer was presented. The composite core consisting of two toroidal cores made of silicon-iron steel (low permeability and high magnetic flux density saturation) and metglas tape (high permeability and low magnetic flux density saturation).
Źródło:
Pomiary Automatyka Kontrola; 2006, R. 52, nr 7/8, 7/8; 38-41
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Układ pomiaru symetrycznych i asymetrycznych prądów zwarciowych z zastosowaniem wielozakresowych przekładników prądowych w warunkach laboratorium zwarciowego
The system of measurement of symmetrical and asymmetric short circuit current with multi range current transformers in conditions of short-circuit testing laboratory
Autorzy:
Babiuch, Michał
Olak, Jan
Powiązania:
https://bibliotekanauki.pl/articles/267651.pdf
Data publikacji:
2019
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
badania zwarciowe
pomiar prądów zwarciowych
przekładnik prądowy
short-circuit test
short-circuit current measurement
current transformer
Opis:
W artykule przedstawiono różne wymagania zawarte w normach przedmiotowych, dotyczące parametrów probierczych dla aparatury elektroenergetycznej i różnych rodzajów badań wykonywanych w laboratorium zwarciowym. Opisano wyposażenie badawczo pomiarowe Zwarciowni Instytutu Elektrotechniki w Warszawie (IEL). Przedstawiono układ pomiaru prądów zwarciowych przy użyciu nowo opracowanych przekładników. Opisano metodę sprawdzenia dokładności przekładników prądowych do pomiaru prądów zwarciowych i zamieszczono przykładowe wyniki i oscylogramy z badań. Układ został wdrożony i jest eksploatowany w Zwarciowni IEL.
The article contains an overview of various requirements for the parameters of the Short-Circuit Testing Laboratory: symmetrical and asymmetrical short-circuit currents, time constant for the disappearance of the constant short-circuit component, asymmetrical peak factor and various types of short-circuit tests performed on various devices operating in power systems, contained in different subject standards . The equipment of the Short-Circuit Testing Laboratory of the Electrotechnical Institute and the modernized test chamber No. 6 is described, equipped with new multi range current transformers and a modern measuring system for short-circuit current. The method of checking the accuracy of current transformers for measuring short-circuit currents is described and example oscillograms are given. The values of the adopted parameters of the transformers and the way of designing the test track are highlighted, enabling the simplification of preparatory works to carry out short-circuit tests and research organization. The article contains electrical diagrams of measurement systems, diagrams of current transformer windings and photograph of modernized test chamber No. 6.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2019, 62; 159-162
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Właściwości metody programowej korekcji błędów częstotliwościowych transformatora prądowego w zakresie nieliniowej pracy przy pomiarach mocy
Properties of the method of current transformer frequency error correction within the range of nonlinear operation for power measurements
Autorzy:
Furmankiewicz, L.
Powiązania:
https://bibliotekanauki.pl/articles/157884.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
błędy częstotliwościowe
korekcja błędów częstotliwościowych
current transformer
frequency errors
frequency error correction
Opis:
Artykuł dotyczy metody korekcji częstotliwościowych błędów modułu i błędów fazowych opracowanej dla liniowych obwodów wejściowych. Korekcja realizowana jest w sposób programowy w dziedzinie widmowej. Przedstawiono wyniki badań eksperymentalnych obrazujące skuteczność metody korekcji przy pomiarach mocy sygnałów w zakresie nieliniowej charakterystyki przetwarzania przekładnika prądowego. Wyniki badań wskazują, że możliwa jest korekcja błędów częstotliwościowych obwodów wejściowych przy pomiarach mocy również w zakresie nieliniowej pracy obwodów wejściowych.
The paper deals with the method for correction of dynamic module and phase errors of linear input circuits. The method is implemented in the spectral domain in a programmed manner using the FFT algorithm. Correction of the signal spectrum is based on frequency characteristics of the input circuit module and phase errors determined on the basis of previous measurements [1]. The method can be used for measuring the RMS value and power of signals. This paper presents the results of experiments showing the effectiveness of the correction method for measuring the power in the range of the current transformer nonlinear operation. Figs. 1a and 1b show the frequency characteristics of the module and phase errors of the current transformer used for tests. The block diagrams of the measuring systems used for examination of the correction effectiveness for measuring sinusoidal and non-sinusoidal waveforms are depicted in Figs. 2 and 3. The power measurement errors before and after correction for a sinusoidal waveform of frequency 50 Hz and 350 Hz and a resistive load are presented in Fig. 4a, while Fig. 4b shows the power measurement errors before and after correction for the phase angle between the voltage and current equal to 30 and 60 degrees. In Tab. 1 there are given the power measurement errors before and after correction for the waveform containing the first and third harmonic and a resistive load. In Tab. 2 there are compared the power measurement errors before and after correction for the waveforms similar to that of the thyristor voltage regulator and for a resistive load. The results show that it is possible to correct the frequency errors of current transformers when measuring the power in the range of the transformer nonlinear operation.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 9, 9; 767-769
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universal Current Transformer for Accurate Measurement of Short-circuit Currents
Uniwersalny przekładnik prądowy do dokładnego pomiaru prądów zwarciowych
Autorzy:
Przybysz, J.
Olak, J.
Piątek, Z.
Powiązania:
https://bibliotekanauki.pl/articles/397436.pdf
Data publikacji:
2017
Wydawca:
ENERGA
Tematy:
current transformer
aperiodic time constant
short circuit tests
przekładnik prądowy
aperiodyczna stała czasowa
badania zwarciowe
Opis:
The paper presents the design of a special current transformer developed by the Institute of Power Engineering in cooperation with TRANSFORMEX sp. z o.o. The aim of the project was to obtain current transformers allowing not only a thorough transformation of symmetrical currents – which is characteristic for typical current transformers, but also of asymmetrical shortcircuit currents containing an aperiodic component, which are not reproduced by classic current transformers. A current transformer has been developed with a range of short-circuit currents established from 1 kA to 50 kA, and short-circuit currents with an aperiodic component with a decay time constant up to 200 ms, peak value from 2.5 kA to 125 kA, assuming the possibility of five-fold repetition of short circuits with the same value and the same constant component polarity, with the assumed transformation accuracy.
W artykule przedstawiono konstrukcję specjalnego przekładnika prądowego opracowanego we współpracy Instytutu Energetyki z firmą TRANSFORMEX sp. z o.o. Celem pracy było uzyskanie przekładników prądowych umożliwiających nie tylko dokładną transformację prądów przemiennych ustalonych – co jest znamienne dla typowych przekładników prądowych, ale również niesymetrycznych prądów zwarciowych zawierających składową bezokresową, których klasyczne przekładniki prądowe nie odtwarzają. Opracowano przekładnik prądowy o zakresie prądów zwarciowych ustalonych od 1 kA do 50 kA oraz prądów zwarciowych ze składową bezokresową o stałej czasowej zanikania do 200 ms, o wartości szczytowej od 2,5 kA do 125 kA, przy przyjęciu możliwości pięciokrotnego powtarzania zwarć tej samej wartości i tej samej biegunowości składowej stałej, przy założonej dokładności transformacji.
Źródło:
Acta Energetica; 2017, 1; 101-106
2300-3022
Pojawia się w:
Acta Energetica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza wpływu niepoprawnego uziemienia przekładników prądowych w układzie Arona na działanie i wskazania 3-fazowego elektronicznego licznika energii elektrycznej
Analysis of influence of current transformer incorrect ground connections in Aron circuit on power measurement results
Autorzy:
Skórkowski, A.
Skubis, T.
Powiązania:
https://bibliotekanauki.pl/articles/154492.pdf
Data publikacji:
2012
Wydawca:
Stowarzyszenie Inżynierów i Techników Mechaników Polskich
Tematy:
przekładnik prądowy
układ Arona
3-fazowy licznik energii elektrycznej
współczynnik korekcyjny
current transformer
Aron system
3-phase energy meter
correction factor
Opis:
W pracy przedstawiono wpływ błędnego połączenia obwodów wtórnych przekładników prądowych na działanie i wskazania układu pomiarowo-rozliczeniowego energii elektrycznej. Uziemienie końców uzwojeń stron wtórnych przekładników prądowych zamiast początków skutkuje zmianą rozpływu prądów w torach prądowych licznika. Przeanalizowano sposób określenia współczynnika korek-cyjnego dla błędnie połączonego układu oraz wielkości mających wpływ na jego wartość.
Influence of incorrect connection of current transformer secondary circuits in Aron circuit on the operation of 3-phase electronic meas-uring and billing system of electrical energy in this paper has been described. Grounding the ends of secondary windings of current transformers instead of beginnings ones causes the current flow change in the measuring system, what was never reported before. Such a mistake connection can happen during the energy meter installation, and is difficult to the detection. It results in significant change of measurement results, lowering the cost of energy to be paid. The explanation of the grounding connection influence into measurement results is given in the paper. The correction factor for long time working incorrectly grounded system is calculated.
Źródło:
Pomiary Automatyka Kontrola; 2012, R. 58, nr 10, 10; 829-832
0032-4140
Pojawia się w:
Pomiary Automatyka Kontrola
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Pomiary pomontażowe urządzeń i sieci elektroenergetycznych średniego napięcia SN
Post-assembly measurements of devices and energy network for MV power grids
Autorzy:
Chrzan, M.
Moszyński, S.
Pietruszczak, D.
Powiązania:
https://bibliotekanauki.pl/articles/310356.pdf
Data publikacji:
2018
Wydawca:
Instytut Naukowo-Wydawniczy "SPATIUM"
Tematy:
pomiary pomontażowe
przekładnik prądowy
sieć elektroenergetyczna
sieć średniego napięcia SN
wyłącznik średniego napięcia SN
post-assembly measurements
current transformer
power grid
medium voltage MV power grids
MV voltage switch
Opis:
W artykule przedstawiono analizę pomiarów pomontażowych urządzeń i sieci elektroenergetycznych średniego napięcia SN. Przedstawiono je na przykładach urządzeń przesyłowo-rozdzielczych występujących w różnych zakładach przemysłowo-wytwórczych w Polsce.
The paper presents the analysis of post-assembly measurements of devices and energy network for MV power grids. They are presented on the examples of transmission and distribution devices present in various industrial and manufacturing plants in Poland.
Źródło:
Autobusy : technika, eksploatacja, systemy transportowe; 2018, 19, 12; 341-349
1509-5878
2450-7725
Pojawia się w:
Autobusy : technika, eksploatacja, systemy transportowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Laboratorium wysokich napięć Politechniki Wrocławskiej 1910-2020
High voltage laboratory of the Wroclaw University of Science and Technology
Autorzy:
Chrzan, Krystian Leonard
Powiązania:
https://bibliotekanauki.pl/articles/268939.pdf
Data publikacji:
2020
Wydawca:
Politechnika Gdańska. Wydział Elektrotechniki i Automatyki
Tematy:
generator udarowy
dzielnik napięciowy
transformator prądowy
laboratorium wysokich napięć
wyposażenie
Politechnika Wrocławska
historia
impulse generator
voltage divider
current transformer
high-voltage laboratory
equipment
Wrocław University of Science and Technology
history
Opis:
Opisano wyposażenie i lokalizacje laboratorium wysokich napięć na Politechnice Wrocławskiej od 1910 roku. Pierwsze laboratorium oddano do eksploatacji bezpośrednio po otwarciu Technische Hochschule Breslau. Jednak dopiero po przybyciu Prof. Paula Boeninga w 1936 r. zaczęto je w pełni wykorzystywać. Prof. Jerzy Ignacy Skowroński w 1946 r. przeniósł laboratorium do znacznie większego pomieszczenia w gmachu A-1, a następnie do budynku D-1 po jego ukończeniu w 1954 roku. Działalność laboratorium można podzielić na trzy okresy: przed II wojną światową 1910-1945, lata kierownictwa Prof. J. I. Skowrońskiego i okres 1971–2020. Największy rozwój laboratorium w zakresie zakupów wyposażenia i liczby zatrudnionych (20 pracowników) przypada na lata 1960-1990. W referacie opisano najważniejsze wyposażenie zakupione lub zmontowane przez Jerzego Lisieckiego.
Equipment and locations of the high voltage laboratory have been described since 1910. The first laboratory was put into operation immediately after the opening of the Technische Hochschule Breslau. However, only after the arrival of prof. Paul Boening in 1936 began to be fully used. Professor Jerzy Ignacy Skowroński in 1946 moved the laboratory to a much larger room in the A-1 building and then to the D-1 building after its completion in 1954. The laboratory can be divided into three periods: the time before World War II 1910-1945, the years of management of Prof. J.I. Skowronski and the years 1971–2020. The years 1960-1990 were the period of the greatest development, purchase of equipment and employment of almost 20 employees. The article describes the most important equipment purchased or assembled by Jerzy Lisiecki.
Źródło:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej; 2020, 70; 41-46
1425-5766
2353-1290
Pojawia się w:
Zeszyty Naukowe Wydziału Elektrotechniki i Automatyki Politechniki Gdańskiej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Korekcja kształtu prądu wtórnego przekładnika prądowego
Correction of the Secondary Current Shape of Current Transformer
Autorzy:
Biel, B.
Jakubowska, A.
Powiązania:
https://bibliotekanauki.pl/articles/1368621.pdf
Data publikacji:
2013
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
przekładnik prądowy
uzwojenie wtórne
krzywa magnesowania
pętla histerezy
energia strat w rdzeniu
przebieg odkształcony
błąd prądowy
błąd całkowity
błąd kształtu
current transformer
secondary winding
magnetization curve
hysteresis loop
energy loss in the core
process deformed
current error
total error
shape error
Opis:
The currents measured in industrial applications reach very high values and at the same time their courses are more and more distorted. In the case of the measurement of alternating current of very high intensity it is necessary to use a current transformer. Such a current transformer should only change the scale of the course but retain its shape. Unfortunately, current transformers distort the shape of the course. These distortions depend mainly on the harmonic content in the primary current and the distortions caused by the ferromagnetic core. The purpose of the article is to define the methodology to minimize the distortion of the secondary current caused by the current transformer, while leaving the distortion of the original course. Minimizing distortions does not consist in the idealization of core parameters but on the development of the algorithm for processing samples using the CT ratio parameters. In this method CT ratio parameters are determined on the basis of the data specified on the nameplate as well as on the basis of measurements. These measurements are carried out without intervention in its interior. The method presented enables more accurate reproduction of the shape of current being measured and can be applied in the industry. The method can be used both for transformers at the design stage and those already in operation.
Prądy mierzone w zastosowaniach przemysłowych osiągają bardzo duże wartości, a jednocześnie kształty przebiegów są coraz bardziej odkształcone. W przypadku pomiaru prądu zmiennego o dużym natężeniu musi być stosowany przekładnik prądowy. Stosowany przekładnik powinien tylko zmienić skalę przebiegu, zachowując jego kształt. Niestety przekładniki prądowe zniekształcają jego kształt. Zniekształcenia te zależą głównie od zawartości harmonicznych w prądzie pierwotnym oraz zniekształceń wprowadzanych przez rdzeń ferromagnetyczny. Celem artykułu jest określenie metodyki zminimalizowania zniekształceń przebiegu prądu wtórnego wprowadzanych przez przekładnik, przy pozostawieniu zniekształceń przebiegu pierwotnego. Minimalizacja zniekształceń nie polega na idealizacji parametrów rdzenia, ale na opracowaniu algorytmu przetwarzania próbek, przy wykorzystaniu parametrów przekładnika. W metodzie tej parametry przekładnika określa się na podstawie danych z tabliczki znamionowej oraz pomiarów. Pomiary te wykonywane są bez ingerencji w jego wnętrze. Przedstawiona metoda umożliwia dokładniejsze odwzorowanie kształtu przebiegu prądu mierzonego i będzie mogła być stosowana w przemyśle. Może być ona stosowana do przekładników zarówno projektowanych jak i już będących w eksploatacji.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2013, 1, 98; 7-12
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies