- Tytuł:
- Supercritical power plant 600 MW with cryogenic oxygen plant and CCS installation
- Autorzy:
-
Kotowicz, J.
Dryjańska, A. - Powiązania:
- https://bibliotekanauki.pl/articles/240262.pdf
- Data publikacji:
- 2013
- Wydawca:
- Polska Akademia Nauk. Czytelnia Czasopism PAN
- Tematy:
-
CFB oxy boiler
oxy-combustion system
supercritical oxy power plant
electricity generation efficiency
cryogenic air separation
kocioł oxy
system spalania
elektrownia
sprawność wytwarzania energii elektrycznej
kriogeniczny rozdział powietrza - Opis:
- This article describes a thermodynamic analysis of an oxy type power plant. The analyzed power plant consists of: 1) steam turbine for supercritical steam parameters of 600°C/29 MPa with a capacity of 600 MW; 2) circulating fluidized bed boiler, in which brown coal with high moisture content (42.5%) is burned in the atmosphere enriched in oxygen; 3) air separation unit (ASU); 4) CO2 capture installation, where flue gases obtained in the combustion process are compressed to the pressure of 150 MPa. The circulated fluidized bed (CFB) boiler is integrated with a fuel dryer and a cryogenic air separation unit. Waste nitrogen from ASU is heated in the boiler, and then is used as a coal drying medium. In this study, the thermal efficiency of the boiler, steam cycle thermal efficiency and power demand were determined. These quantities made possible to determine the net efficiency of the test power plant.
- Źródło:
-
Archives of Thermodynamics; 2013, 34, 3; 123-137
1231-0956
2083-6023 - Pojawia się w:
- Archives of Thermodynamics
- Dostawca treści:
- Biblioteka Nauki