Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "fire temperature" wg kryterium: Temat


Wyświetlanie 1-9 z 9
Tytuł:
Analysis of the load-carrying capacity of a steel frame under fire conditions
Autorzy:
Bilko, P.
Sawczynski, S.
Powiązania:
https://bibliotekanauki.pl/articles/30147187.pdf
Data publikacji:
2018
Wydawca:
Akademia Wojsk Lądowych imienia generała Tadeusza Kościuszki
Tematy:
fire
ultimate limit state
steel structures
critical temperature
fire resistance
Opis:
This article aims at presenting the basic principles of designing steel structures according to Eurocode PN-EN 1993-1-2, i.e. with respect to ensuring the appropriate level of safety for such structures in case of a fire developing into flashover. The load-carrying capacity of a steel structure, serving as an example, was assessed on the basis of a static strain-stress analysis. The analysis was conducted regarding changes in the temperature of structural members, both the exposed and the fireproof protected ones, under fire conditions.
Źródło:
Scientific Journal of the Military University of Land Forces; 2018, 50, 1(187); 129-139
2544-7122
2545-0719
Pojawia się w:
Scientific Journal of the Military University of Land Forces
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Critical Temperature Evaluation for a Steel Frame with Joint Stiffness Decreasing in Fire
Autorzy:
Maślak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/105154.pdf
Data publikacji:
2018
Wydawca:
Politechnika Rzeszowska im. Ignacego Łukasiewicza. Oficyna Wydawnicza
Tematy:
steel bearing frame
fire
critical temperature
joint stiffness
moment-rotation relationship
weakest link
Opis:
A procedure to determine the critical temperature of a selected steel frame bearing structure is presented and discussed. This temperature, in case of fully developed fire, when the temperature of the exhaust gasses enveloping the structural members is equalized within the whole fire zone, may be considered as an impartial measure of safety. The obtained result does not depend on the heating progress but only on the static scheme and the load level in the considered structure. The quantitative and qualitative evaluation of the influence the joint stiffness decreasing in fire exerts on the resultant critical temperature constitutes the basic objective of the authors. It has been shown, that proceeding according to the recommended computational procedure does not necessarily result in an estimate fully unambiguous in interpretation. The critical temperature specified in a global mode, for the whole considered frame, is usually associated with a specific component of such frame, interpreted as the so called “weakest link”. Thus local loss of bearing capacity in such element is in this approach equivalent to the total destruction of the whole bearing structure. Indication, which of the components present in the considered frame should be treated as the critical one, because of its behaviour under fire conditions, seems to be a key to the forecast safety level warranted to the users of the structure. The authors show, that this association changes depending on the selected computational method, and this in turn substantially limits the reliability of the obtained estimate.
Źródło:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury; 2018, 65, 2; 91-101
2300-5130
2300-8903
Pojawia się w:
Czasopismo Inżynierii Lądowej, Środowiska i Architektury
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Programowanie liniowe jako technika obliczeniowa użyteczna w szacowaniu odporności ogniowej stalowej ramowej konstrukcji nośnej
Linear Programming as a Computational Procedure Useful in the Fire Resistance Evaluation of a Steel Loadbearing Frame Structure
Autorzy:
Maślak, M.
Tkaczyk, A.
Powiązania:
https://bibliotekanauki.pl/articles/372850.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
stalowa ramowa konstrukcja nośna
pożar
odporność ogniowa
temperatura krytyczna
programowanie liniowe
steel frame load bearing structure
fire
fire resistance
critical temperature
linear programming
Opis:
Cel: Przedstawiono i przedyskutowano oryginalną procedurę szacowania odporności ogniowej stalowego ramowego ustroju nośnego opartą na zastosowaniu metodyki programowania liniowego. Tego typu podejście wymaga dokonania linearyzacji zarówno klasycznych warunków równowagi, jak i warunku opisującego uplastycznienie krytycznego przekroju poprzecznego w elemencie stalowym miarodajnym do oceny nośności badanej ramy. Przekroje wybrane do analizy odpowiadają lokalizacji aktywujących się w pożarze przegubów plastycznych. Metody: Miarą poszukiwanej odporności jest określona dla całej ramy temperatura krytyczna odpowiadająca osiągnięciu przez badany ustrój stanu granicznego nośności ogniowej. Stan ten identyfikowany jest z realizacją tego spośród potencjalnie możliwych mechanizmów czysto plastycznego zniszczenia ramy, który odpowiada najniższej możliwej wartości temperatury aktywacji. Taka specyfikacja wymaga akceptacji założenia, że przez cały czas trwania pożaru prognozowanego dla analizowanego ustroju nośnego wszystkie elementy tego ustroju będą efektywnie stężone. Dzięki temu nie występuje ryzyko jego wcześniejszego zniszczenia przez globalną lub lokalną formę utraty stateczności. Wyniki: Pokazano sposób ogólnego formułowania problemu oraz specyfikacji funkcji celu, a także zasady budowy nierówności definiujących miarodajne ograniczenia. Uwzględniono przy tym interakcję momentu zginającego i siły podłużnej. Algorytm postępowania zilustrowano na załączonym przykładzie numerycznym. Uzyskane z rekomendowanych w pracy obliczeń oszacowanie temperatury krytycznej badanej ramy odniesiono do odpowiadającego mu wyniku alternatywnej analizy, przeprowadzonej w celach porównawczych, opartej na zastosowaniu klasycznego kinematycznego podejścia do teorii nośności granicznej. Wnioski: Zaproponowane podejście obliczeniowe w opinii autorów artykułu jest bardziej uniwersalne w stosunku do możliwych procedur alternatywnych, rekomendowanych we wcześniejszych pracach. Pozwala bowiem na jednoznaczne i czytelne w interpretacji oszacowanie odporności ogniowej także w przypadku ram o złożonej geometrii i rozbudowanym schemacie obciążenia. W świetle założeń modelu formalnego, przytoczonych i szczegółowo dyskutowanych w tekście, uzasadnione może być również twierdzenie o znacząco większej wiarygodności uzyskanych w ten sposób oszacowań temperatury krytycznej analizowanej ramy w porównaniu do oszacowań otrzymanych w sposób konwencjonalny.
Aim: A new original procedure which can be applied to evaluate the fire resistance of a steel frame, based on the linear programming approach, is presented and discussed in this article. Such a computational technique requires the linearisation of both the classical equilibrium conditions and a condition describing the yield of a critical cross-section relating to the structural member conclusive in assessing the frame resistance. The sections selected for the analysis correspond to the location of the plastic hinges forming as a consequence of fire exposure. Methods: The critical temperature, determined for the whole structure, and associated with the structure reaching its fire resistance limit state, is considered to represent the measure of such a fire resistance. This critical temperature corresponds to the realisation of such a potentially possible purely plastic failure mechanism that is bound to the lowest possible formation temperature. Such a specification requires the assumption that throughout the duration of the fire foreseen for the considered bearing structure, all the components of this system will be effectively braced, so that there is no risk of their earlier failure by local or global loss of stability. Results: The general problem formulation approach, the formulation of the objective function, and the rules governing the development of inequalities defining the representative constraints, are presented in detail. The interaction between the longitudinal force and the bending moment is taken into account as well. The obtained results are illustrated by the numerical example. The estimate resulting from the calculation recommended in this article is related to the corresponding one based on the use of the kinematical approach to the theory of plasticity. Conclusions: The proposed computational approach seems to be more universal in relation to the possible alternative procedures recommended by the authors of this study in their earlier works. It facilitates an unambiguous and clearly interpretable estimate of the steel frame fire resistance also sought in the case of the frame with complex geometry and a complicated load arrangement. In the light of the assumptions of a formal model discussed in detail in this article, the conclusion can also be made that the reliability of the estimates so obtained is significantly greater in comparison to the corresponding results calculated conventionally.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 99-120
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Probability-based critical temperature assessment for simple steel beam exposed to fire
Probabilistyczna ocena temperatury prostej belki stalowej eksponowanej na oddziaływanie pożaru
Autorzy:
Maslak, M.
Powiązania:
https://bibliotekanauki.pl/articles/231402.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
pożar
temperatura krytyczna
wymagania bezpieczeństwa
prawdopodobieństwo uszkodzenia
wskaźnik niezawodności
fire
critical temperature
safety requirements
failure probability
reliability index
Opis:
Zaproponowano i szczegółowo przedyskutowano nowe podejście do szacowania temperatury krytycznej eksponowanej na warunki pożarowe stalowej konstrukcji nośnej. Opiera się ono na rozważaniach w pełni probabilistycznych i może stanowić alternatywę w stosunku do tradycyjnych obliczeń normowych. W opinii autora rezultaty uzyskane dzięki zastosowaniu prezentowanej metodyki można uznać za bardziej wiarygodne i lepiej uzasadnione w zestawieniu z odpowiadającymi im wynikami otrzymanymi metodami konwencjonalnymi. Taki wniosek można uzasadnić faktem uwzględnienia w analizie losowego charakteru zarówno przyłożonych do konstrukcji obciążeń zewnętrznych jak i miarodajnej nośności przekroju poprzecznego, redukowanej wskutek oddziaływania na elementy konstrukcyjne wysokiej temperatury pożarowej. Ponadto wymagania co do gwarantowanego poziomu bezpieczeństwa ustalono w sposób bardziej racjonalny, przez specyfikację granicznej wartości prawdopodobieństwa zniszczenia, maksymalnej możliwej do zaakceptowania w warunkach wyjątkowej sytuacji projektowej kojarzonej z pożarem rozwiniętym potencjalnie zainicjowanym w rozważanej strefie pożarowej. Oszacowana w ten sposób temperatura krytyczna stalowej konstrukcji nośnej, kojarzona z osiągnięciem przez tę konstrukcję stanu granicznego nośności ogniowej, jest zawsze wyższa niż odpowiadająca jej temperatura wyliczona przy zastosowaniu konwencjonalnej procedury normowej. Wynika stąd wniosek, że tradycyjny algorytm normowy, opierający się najpierw na specyfikacji a następnie na porównywaniu ze sobą reprezentatywnych, obliczeniowych wartości miarodajnego efektu obciążenia i odpowiadającej temu efektowi nośności elementu, daje oszacowania wprawdzie bezpieczne ale niepotrzebnie nazbyt konserwatywne.
An advanced evaluation technique, helpful in the fire resistance assessment of a simple steel structure exposed to fire is presented and discussed in detail on the example of an unrestrained and uniformly heated steel beam. The proposed design methodology deals with the generalised probability-based approach in which the most probable failure point is formally identified. The random nature of all variables considered in the detailed analysis is taken into account. The critical temperature of the steel from which the considered beam is made of is accepted here as the authoritative safety measure. This temperature value is associated with the fire resistance limit state defined for the maximum acceptable value of failure probability. When forecasting the failure probability, not only the risk of a potential fire being initiated but also not being effectively extinguished is included in the calculation. Various levels of the target failure probability may be assumed in such the analysis, depending on the selected reliability class. They are specified in general by setting an appropriate value of the required reliability index β fire req. In the presented design algorithm no representative values of the considered random variables are specified. The critical temperature estimates obtained from these calculations are always less restrictive in comparison with the corresponding solutions computed after applying the conventional standard procedure.
Źródło:
Archives of Civil Engineering; 2020, 66, 3; 675-692
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
An analysis of the resistance of an extended end-plate beam-to-beam connection subjected to tension in fire conditions
Autorzy:
Słowikowska, Alina
Polus, Łukasz
Powiązania:
https://bibliotekanauki.pl/articles/390133.pdf
Data publikacji:
2019
Wydawca:
Politechnika Lubelska. Wydawnictwo Politechniki Lubelskiej
Tematy:
beam-to-beam connection
fire resistance
steel joint
critical temperature
połączenie belka-belka
odporność ogniowa
złącze stalowe
temperatura krytyczna
Opis:
This paper presents an analysis of the fire resistance of a steel joint subject-ed to tension. The authors of this article used prescriptive rules and simple calculation models to present an impact of the value of the load on the fire resistance of the connection. Designers often evaluate the critical temperature and fire resistance time of steel elements. However, they neglect the evaluation of the above-mentioned values for steel connections. In this article a simple engineering method was used to calculate the fire resistance of the joint.
Źródło:
Budownictwo i Architektura; 2019, 18, 1; 81-88
1899-0665
Pojawia się w:
Budownictwo i Architektura
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Zastosowanie zaawansowanej metody oceny odporności ogniowej w budownictwie przemysłowym
Application of advanced fire resistance assessment method for industrial structures
Autorzy:
Woźniczka, Piotr
Powiązania:
https://bibliotekanauki.pl/articles/128943.pdf
Data publikacji:
2020
Wydawca:
PWB MEDIA Zdziebłowski
Tematy:
ocena odporności
odporność ogniowa
hala stalowa
symulacja
rozwój pożaru
odpowiedź mechaniczna
modelowanie konstrukcji
temperatura krytyczna
model zniszczenia
resistance assessment
fire resistance
steel hall
simulation
fire development
mechanical response
structure modelling
critical temperature
failure mode
Opis:
W artykule przedstawiono przykład opracowanej oceny odporności ogniowej obiektu przemysłowego. Dla rozpatrywanej hali maszynowni o konstrukcji stalowej zaprezentowano wyniki symulacji rozwoju pożaru oraz odpowiedzi mechanicznej konstrukcji. Obliczenia przeprowadzono za pomocą zaawansowanych programów komputerowych. Omówiono wpływ takich czynników, jak nierównomierne ogrzewanie oraz sposób modelowania konstrukcji na szacowaną odporność ogniową. Wskazano także wartości temperatury krytycznej oraz prognozowane modele zniszczenia. Wykazano, że omawiana metoda może być z powodzeniem stosowana w odniesieniu do rozpatrywanej kategorii obiektów.
Both fire development and mechanical response analysis of the steel turbine hall are described. Factors like non-uniform heating and way of structural modeling and their impact on the anticipated fire resistance of the structure are discussed. Moreover, values of the crictical temperature and predicted failure modes are given. As a result it is shown that described method is appropriate for the considered type of buildings.
Źródło:
Builder; 2020, 24, 4; 58-60
1896-0642
Pojawia się w:
Builder
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Universalʹnyj kompleksnyj pokazatelʹ èndogennoj požaroopasnosti
Universal Index of Endogenous Fire Hazards
Uniwersalny kompleksowy wskaźnik zagrożenia pożarem endogenicznym
Autorzy:
Grekov, S. P.
Pashkovskiy, P. S.
Vsyakiy, A. A.
Powiązania:
https://bibliotekanauki.pl/articles/373280.pdf
Data publikacji:
2016
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
spontaneous combustion
critical temperature
critical thickness of coal seams
incubation period
spontaneous combustion fire hazard group
samozapłon
temperatura krytyczna
krytyczna grubość złóż
okres inkubacyjny
grupa zagrożenia pożarem endogenicznym
Opis:
Aim: The purpose of this study is to develop a universal hazard indicator associated with spontaneous fires. Development of the proposed indicator is based on mathematical techniques and aligned to laboratory investigations of chemical activity and analysis of causes for the selfheating of coal and ultimately fires in coal mines, which have taken place over a period of many years. Methods: The study made use of the theoretical kinetic model for heterogeneous oxidation of coal with variable reactionary surfaces, examined more than 200 locations and analysed causes of spontaneous fires, which occurred in 42 coal seams during a ten-year period. Results: An analysis of locations and causes of spontaneous fires in coal mines was accompanied by a study of currently applied evaluation criteria for coal seam propensity to spontaneous combustion and identified limitations associated with such evaluations. The authors proposed the use of a mathematical model describing heterogeneous oxidation of coal exposed to the evaporation of moisture and supply restriction of methane to determine a complex indicator of a fire hazard. It was revealed that a significant influence on temperature change in materials, apart from time, is associated with oxidation constant, methane heat suppression, coal seam gas content, moisture loss rate constant, evaporation heat rate, value of the criterion Bi and oxygen concentration in coal. The oxygen content of coal is determined by its natural properties: oxygen coefficient of internal diffusion, porosity, brittleness, fractional composition, degree of metamorphism as well as concentration of oxygen on the coal surface. A relationship was identified for the fire hazard indicator with heat release and heat transfer. Additionally, the study confirmed parameters used to differentiate coal mines according to fire hazard groups with the use of mathematical models and more than 200 fire incident sources of data. Finally, the study revealed necessary influences, which determine the incubation period for spontaneous combustion, critical size of accumulated coal seams and critical threshold value for predicting the likelihood of self ignition of coal. Practical value: Identified dependencies are recommended for use in the industry to recognise fire hazard levels associated with spontaneous combustion in coal deposits. Conclusions: Developed a new complex indicator for endogenous fire hazards and, based on data from analysed coal samples in laboratory conditions, facilitated the definition of necessary coal characteristics: critical size of coal deposits clusters/dangerous accumulation of coal, threshold values for the estimation criterion of propensity for spontaneous combustion, incubation period and fire hazard group.
Cel: Opracowanie uniwersalnego i kompleksowego wskaźnika zagrożenia pożarem endogenicznym na podstawie modelu matematycznego samonagrzewania węgla, badań laboratoryjnych jego aktywności chemicznej oraz analizy przyczyn rzeczywistych pożarów endogenicznych w kopalniach, które miały miejsce na przestrzeni wielu lat. Metody: Metody zostały oparte na modelu teoretycznym kinetyki heterogenicznego utlenienia węgli ze zmienną powierzchnią reakcyjną, analizie ponad 200 miejsc i przyczyn rzeczywistych pożarów endogenicznych 42 pokładów złoża węgla w okresie 10 lat. Wyniki: Przeprowadzono analizę miejsc i przyczyn postawania pożarów endogenicznych w kopalniach węglowych, przeanalizowano obecnie stosowane kryteria oceny skłonności złóż do samozapłonu i przedstawiono ich wady. Zaproponowano wykorzystanie modelu matematycznego heterogenicznej reakcji utleniania węgla z uwzględnieniem wyparowywania wilgoci i dławienia metanu w celu opracowania kompleksowego wskaźnika zagrożenia pożarem endogenicznym. Wskazano, że znaczny wpływ na zmianę temperatury materiału, poza czasem, mają konstanta reakcji utleniania, ciepło dławienia metanu, zawartość gazów w złożu, konstanta prędkości wyparowania wilgoci, ciepło parowania, wartość kryterium Bi i stężenie tlenu w węglu. Na wartość stężenia tlenu w węglu mają wpływ jego naturalne właściwości – współczynnik wewnętrznej dyfuzji, porowatość, kruchość, skład frakcyjny, stopień metamorfizmu, a także stężenie tlenu na granicy węgiel-powietrze. Otrzymano zależność dla kryterium zagrożenia pożarowego z uwzględnieniem wydzielenia i oddawania ciepła. Uzasadniono parametry dla podziału kopalni na grupy zagrożenia pożarowego na podstawie modelu matematycznego i danych z ponad 200 rzeczywistych zdarzeń. Przedstawiono zależności potrzebne do określenia okresu inkubacyjnego samozapłonu, krytycznej wielkości pokładów węgla, granicznej wartości kryterium oceny skłonności węgla do samozapłonu. Znaczenie praktyczne: Uzyskane zależności są rekomendowane do wykorzystania w przemyśle do określania stopnia zagrożenia pożarem endogenicznym złóż węgla. Wnioski: Opracowano nowy kompleksowy wskaźnik zagrożenia pożarem endogenicznym, który na podstawie danych z analizy próbek węgla w warunkach laboratoryjnych, pozwala określić wszystkie charakterystyki węgla: krytyczną wielkość zagrożenia pożarem skupiska złoża węgla, progową wartość kryterium oceny podatności na samozapłon, okres inkubacyjny i grupę zagrożenia pożarowego.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2016, 44, 4; 89-97
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ambiguity in determining the critical temperature of a steel sway frame with semi-rigid joints
Niejednoznaczność w wyznaczaniu temperatury krytycznej stalowej ramy przechyłowej z podatnymi węzłami
Autorzy:
Maslak, M.
Pazdanowski, M.
Snela, M.
Powiązania:
https://bibliotekanauki.pl/articles/1849756.pdf
Data publikacji:
2020
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
odporność ogniowa
rama stalowa
temperatura krytyczna
węzeł sztywny
węzeł półsztywny
węzeł doczołowy
węzeł belka-słup
fire resistance
steel frame
critical temperature
fully rigid joint
semi rigid joint
end plate joint
beam to column joint
Opis:
The problem of uniqueness and representativeness of steel frame fire resistance assessment is considered in this paper. The thesis, that the selection of analysis method determines the result in both qualitative and quantitative terms is given scrutiny. It is also shown, that the differences between computed values may be significant. The selection of an appropriate computational model for an analysis of this type seems to be especially important, as the possible overestimation of the fire resistance determined during computation is equivalent to an unjustified optimism of the user with respect to the safety level warranted. In the considerations presented here the critical temperature determined for the whole bearing structure is considered as the measure of sought resistance. The determined temperature is associated with the bearing structure reaching the bearing capacity limit state subject to fire conditions, treated as accidental design situation. Two alternative computational methods have been applied during calculations: the first one - classical, based on 1st order statics and using the buckling length concept for members of the considered frame, and the second one - taking account of 2nd order phenomena via simple amplification of the horizontal loads applied to the frame. Special attention has been paid to the influence exerted on the final fire resistance of the considered structure by the real joint rigidity, decreasing with increasing temperature of the structural members. The obtained results differ not only in the value of determined temperature but also in the indicated location of the weakest frame component, determining its safety.
W pracy rozważa się problem jednoznaczności i reprezentatywności oszacowania odporności ogniowej ramy stalowej. Weryfikacji poddano tezę, że wybór metody analizy determinuje uzyskany wynik zarówno pod względem ilościowym jak i jakościowym, a różnice pomiędzy wyliczonymi wartościami mogą okazać się znaczące. Dobór miarodajnego modelu obliczeniowego w tego typu analizie wydaje się być szczególnie ważny, bowiem ewentualne przeszacowanie wyznaczonej z obliczeń odporności jest równoznaczne z nieuzasadnionym optymizmem użytkownika budynku co do gwarantowanego mu poziomu bezpieczeństwa. W prezentowanych rozważaniach miarą poszukiwanej odporności jest temperatura krytyczna specyfikowana dla całego ustroju nośnego. Nie zależy ona od prognozowanego scenariusza rozwoju pożaru i z tego względu może zostać uznana za pewnego rodzaju charakterystykę samej konstrukcji. Wyznaczana temperatura kojarzona jest z osiągnięciem przez ustrój nośny stanu granicznego nośności w warunkach pożaru traktowanego jako wyjątkowa sytuacja projektowa. Nie oznacza to jednak natychmiastowej katastrofy badanej konstrukcji ale jedynie sytuację, gdy prawdopodobieństwo tego rodzaju zdarzenia staje się już na tyle duże że nie może być dalej akceptowane. Do szczegółowej analizy wykorzystano dwie alternatywne procedury obliczeń: pierwszą - opartą o klasyczną statykę pierwszego rzędu, z wykorzystaniem koncepcji długości wyboczeniowej elementów badanej ramy, i drugą - uwzględniającą efekty drugiego rzędu przez prostą amplifikację przyłożonego do tej ramy obciążenia poziomego.
Źródło:
Archives of Civil Engineering; 2020, 66, 4; 611-632
1230-2945
Pojawia się w:
Archives of Civil Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Użyteczność modelu obliczeniowego pojedynczej ramy poprzecznej w szacowaniu odporności ogniowej hali stalowej
The Usability of a Computational Model of a Single Transverse Frame in the Fire Resistance Assessment of an Entire Steel Hall
Autorzy:
Maślak, M.
Tkaczyk, A.
Woźniczka, P.
Powiązania:
https://bibliotekanauki.pl/articles/373628.pdf
Data publikacji:
2017
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
hala stalowa
odporność ogniowa
rama poprzeczna
model obliczeniowy
podejście Merchanta-Rankine’a
nośność sprężysta
nośność plastyczna
temperatura krytyczna
steel hall
fire resistance
transverse frame
computational model
Rankine-Merchant approach
purely elastic resistance
purely plastic resistance
critical temperature
Opis:
Cel: Celem zaprezentowanych rozważań jest wypracowanie miarodajnej odpowiedzi na pytanie o wiarygodność stosowania modelu obliczeniowego pojedynczej ramy poprzecznej wyizolowanej ze złożonego ustroju nośnego hali stalowej w ocenie odporności ogniowej tej hali. Badanie zachowania się w pożarze pojedynczej ramy poprzecznej poprzez weryfikację kolejnych potencjalnie możliwych form jej zniszczenia umożliwia specyfikację poszukiwanej odporności interpretowanej jako określona dla tej ramy temperatura krytyczna, niezależna od przyjętego scenariusza rozwoju pożaru. Temperatura ta kojarzona jest jednoznacznie z osiągnięciem przez ustrój nośny analizowanej ramy stanu granicznego nośności ogniowej. Metody: Do specyfikacji temperatury krytycznej wybranej ramy proponuje się procedurę obliczeniową opartą na uogólnionej na przypadek pożaru formule Merchanta-Rankine’a. Kwantyfikuje ona miarodajną nośność badanej ramy poprzez interakcję odpowiednich nośności skojarzonych z czysto sprężystą i czysto plastyczną formą jej zniszczenia. Opisano ograniczenia wybranej przez autorów metody oceny wynikające z konieczności akceptacji wielu upraszczających założeń formalnych. Pokazano również, jak na otrzymane rezultaty wpływa stopień złożoności zastosowanego modelu obliczeniowego. Wyniki: Weryfikację i walidację proponowanej w artykule procedury obliczeniowej przeprowadzono porównując przemieszczenia wybranych węzłów ramy poprzecznej hali stalowej analizowanej dla warunków pożaru. Chodziło o sprawdzenie, jakiego typu i jak duże rozbieżności wynikają z zastosowania uproszczonego modelu dwuwymiarowego pojedynczej ramy w stosunku do wyników otrzymanych z analizy pełnego trójwymiarowego modelu ustroju nośnego całej hali. Wnioski: Wykazano, że uproszczony model obliczeniowy pojedynczej ramy poprzecznej hali stalowej jest wystarczająco wiarygodny w przypadku, gdy o odporności ogniowej tej ramy decyduje pierwsza faza pożaru, gdy nie ma jeszcze znaczącego przyrostu prędkości deformacji elementów nośnych. Jeżeli jednak badana rama zapewnia bezpieczne przenoszenie przyłożonych do niej obciążeń także wtedy, gdy mamy do czynienia z dużymi deformacjami i znacznym osłabieniem elementów decydujących o nośności ramy, to oszacowanie prognozowanej odporności na podstawie modelu ograniczonego do pojedynczej ramy poprzecznej może być nazbyt optymistyczne. Nie uwzględnia bowiem przyspieszania ugięcia rygla przez ogrzane w pożarze płatwie dachowe rozciągane osiowo wskutek tak zwanego efektu cięgna.
Aim: The aim of these considerations is to achieve a reliable answer to the question about the credibility of the use of a simple computational model with a single transverse frame isolated from a complex load-bearing structure of an entire steel hall in the fire resistance-evaluation of such a hall. The study of the behaviour of a simple transverse frame under fire conditions through checking all its potential failure modes allows to specify the required fire resistance which can be interpreted as the critical temperature set especially for this frame and being independent of the fire scenario adopted for the analysis. This temperature is unequivocally associated with the reaching by the frame load-bearing structure of the fire-resistance limit state. Methods: The classical Rankine-Merchant formula generalised to the fire case is proposed to be used in the specification of the critical temperature for the transverse frame selected for the analysis. It quantifies the reliable bearing capacity of the tested frame through the interaction of the appropriate capacities associated with purely elastic and purely plastic failure modes. The limitations of the assessment method recommended by the authors are described in detail, resulting from the need for the acceptance of many formal assumptions simplifying the analysis. The impact of the complexity of the formal model adopted for the assessed frame fire-resistance evaluation on the obtained results is also verified. Results: Both the verification and the validation of the computational procedure proposed by the authors in this article were performed by comparing the displacements of the selected nodes in the transverse frame analysed for fire conditions. The idea was to check what type of differences are obtained through the use of a simplified two-dimensional computational model of a single frame in relation to the corresponding results obtained when a complex three-dimensional model of the entire hall is considered, and how big they are. Conclusions: It has been shown that the simplified computational model of a single transverse frame selected from the entire steel hall seems to be sufficiently reliable in the case in which fire resistance of such a frame is determined by the first phase of this fire, when the deformation rate of all bearing members is not yet significantly increased. However, if the tested frame also ensures the safe transfer of all loads applied to it when we are dealing with large deformations and large weakening of the members determining the real capacity of such a frame then the assessment of the predicted fire resistance obtained on the basis of the model limited to the analysis of only a single transverse frame might prove to be too optimistic. It does not account for the acceleration of the deflection of the frame beam due to the action of the heated purlins being in tension as a consequence of the so called catenary effect.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2017, 45, 1; 52-67
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-9 z 9

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies