Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "treatment wetland" wg kryterium: Temat


Wyświetlanie 1-11 z 11
Tytuł:
Textile Wastewater Treated by Constructed Wetlands – A Critical Review
Autorzy:
Hussein, Amjad
Powiązania:
https://bibliotekanauki.pl/articles/24201781.pdf
Data publikacji:
2023
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
azo dye
constructed wetland
textile wastewater
treatment
Opis:
Textile industries are among the most environmentally unsustainable businesses, releasing large amounts of effluent that endangers ecosystem health. Constructed wetlands (CWs) are low-cost eco-technical treatments for industrial wastewater control. The CWs are self-contained remediation systems that do not require external energy and have basic mechanisms for pollutant removal, such as biological, chemical, and physical processes. For more than sixty years, constructed wetlands have been utilized to clean wastewater. Most applications have been developed to treat municipal or household wastewater, although CWs are now successfully used to treat a wide range of wastewater types. Constructed wetlands were also employed to treat textile industry effluents in the 1990s. The survey indicated that textile manufacturing wastewaters were treated using subsurface and surface-flow wetlands. Both horizontal and vertical flow systems have been designed within subsurface flow-created wetlands. In addition, many hybrid-built wetlands have recently been documented in the literature for textile industrial wastewater treatment. According to the survey, textile industrial wastewater is treated in constructed wetlands on all continents, and this research includes the data from 65 constructed wetlands in 21 nations worldwide. This paper examined the latest improvements and discoveries in CWs and the many types of CWs used for textile wastewater treatment. The paper also demonstrated state-of-the-art integrated technologies for improving the performance and sustainability of CWs, such as CW-MFC systems.
Źródło:
Journal of Ecological Engineering; 2023, 24, 5; 256--275
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Kinetics of Pollutants Removal in Wetlands Influenced by Retention Time and Number of Plants Using Cyperus alternifolius
Autorzy:
Rahman, Danar Arifka
Priambodo, Eka Wahyudi
Caturputranto, Trisnadi Widyaleksono
Wahyudianto, Febri Eko
Powiązania:
https://bibliotekanauki.pl/articles/2202280.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
constructed wetland
Cyperus alternifolius
kinetics
wastewater treatment
Opis:
Constructed wetland is considered an alternative for domestic wastewater treatment in cities. This study serves to evaluate the removal capacity and kinetics of TSS, COD, phosphate, and surfactant in domestic wastewater with several plants of Cyperus alternifolius, through the use of the constructed wetlands treatment. The overall objective of the study was to determine the ability of Cyperus alternifolius to remove water pollutants in domestic wastewater in several plants. The domestic wastewater was contacted in a batch system. The results indicated that CWs had a good performance on COD, phosphate, and surfactant with removal efficiencies of more than 80%, with a retention time of 8 days and 5 plants. However, the removal of suspended solids was found limited, as shown that the TSS removal efficiency was under 40%. The first-order equation of kinetics described the degradation of pollutants. The q1/2 values, which were defined as the average removal loading prior to the half of the pollutant concentration being removed and represented the removal capacity without limitation of pollutants concentration, were moderately increased with an addition to the number of plants.
Źródło:
Journal of Ecological Engineering; 2022, 23, 12; 37--43
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza statystyczna zawartości azotu ogólnego w złożu oczyszczalni hydrofitowej w Małyszynie
Statistical analysis of total nitrogen in the soil of constructed wetland in Małyszyn
Autorzy:
Jakubaszek, A.
Wojciech, M.
Powiązania:
https://bibliotekanauki.pl/articles/372002.pdf
Data publikacji:
2011
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
oczyszczanie ścieków
oczyszczalnia hydrofitowa
wastewater treatment
constructed wetland
Opis:
Usuwanie związków azotu w oczyszczalniach hydrofitowych uzależnione jest od wielu czynników fizyczno-chemicznych i biochemicznych oraz warunków środowiskowych. W artykule przedstawiono opracowanie statystyczne zawartości azotu ogólnego w złożu hydrofitowym oczyszczalni. Wyniki badań materiału filtracyjnego wykazały, że największą zawartością azotu charakteryzowała się powierzchniowa warstwa gruntu do 20 cm głębokości. Kumulacja azotu ogólnego malała wraz z penetracją w głąb złoża oraz w kierunku odpływu ścieków z oczyszczalni.
Removal of nitrogen from constructed wetlands depends on many physic-chemical and biochemical conditions, deposit and environmental factors. The paper contains the results of statistical analysis the accumulation of total nitrogen in the soil. The results of the research have indicated that the highest content of nitrogen was observed in the surface layer of the soil at a depth of up to 20 cm. The content of total nitrogen has dropped with the penetration depth and towards the sewage flow from the constructed wetland.
Źródło:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski; 2011, 142 (22); 75-85
1895-7323
Pojawia się w:
Zeszyty Naukowe. Inżynieria Środowiska / Uniwersytet Zielonogórski
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Improving Wastewater Reclamation Using Constructed Wetlands by Artificial Plastic Biofilm Carriers
Autorzy:
Zaboon, Baneen Hussein
Al-Abbawy, Dunya A. H.
Yaseen, Dina A.
Powiązania:
https://bibliotekanauki.pl/articles/2202266.pdf
Data publikacji:
2022
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
wastewater treatment
free-water surface
Lemna minor
constructed wetland
Opis:
Increasing the demand for potable water, followed by the high quantity of discharged effluents linked with the water scarcity problems has necessitated giving more attention to improving wastewater treatment processes and operations. The constructed wetland has proven to be an excellent green sustainable technique for purification. This study aimed to examine the performance of four experimental free water surface constructed wetlands (FWSCWs) for the depuration of sewage effluents as a secondary treatment stage during winter season conditions. The objectives were to assess the raw and treated wastewater concentrations, evaluate the removal efficiency of chemical oxygen demand (COD), biological oxygen demand (BOD), nutrients, and total suspended solids (TSS) of each treatment line, and compare the impact of plastic rings (biofilm carriers) and Lemna minor L. with the presence of gravel bed on the treatment efficiency and bacterial growth, as well as assess the plant’s adaption and growth. The results showed that all treatment systems improved the water characteristics, and adding biofilm carriers enhanced the efficiency of water purification, especially BOD reduction. The combination of the plants, biofilm carriers, and gravel in the wetland filter significantly enhanced (ρ < 0.05) the treatment efficiency in terms of TSS, COD, BOD, Ammonia (NH3), Nitrates (NO3), and Orthophosphate (PO4) compared to the control treatment system (gravel bed). Plant growth was restricted in the presence of carriers in the system. Further study for examining the system performance under summer conditions, which may improve the nutrient reduction rates by biofilm carriers, is underway.
Źródło:
Journal of Ecological Engineering; 2022, 23, 11; 241--253
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of COD Fractions in Raw Wastewater Flowing into Small and Large Wastewater Treatment Plants
Autorzy:
Ignatowicz, Katarzyna
Powiązania:
https://bibliotekanauki.pl/articles/124764.pdf
Data publikacji:
2019
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
COD fractions
treatment plants
rotary biological contactor
constructed wetland
activated sludge
Opis:
The aim of the study was to determine and compare the amount and biodegradability of organic compounds determined by the COD measure contained in raw sewage inflowing to small sewage treatment plants and municipal sewage wastewater treatment plants with high personal equivalent (P.E.). Raw sewage samples were collected in three chosen facilities. The research presented in the article were conducted with two small plants: constructed wetland plant with an average capacity of 4 m3/d and the treatment plant with rotary biological contactor (RBC) with an average capacity of 5 m3/d. Also big municipal wastewater treatment plant (WWTP) with activated sludge in Bialystok with a capacity of about 63 000 m3/d was checked. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was founded in raw sewage in small wastewater treatment plants (CW and RBC).
Źródło:
Journal of Ecological Engineering; 2019, 20, 11; 197-201
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Nitrogen and phosphorus content in constructed wetlands
Autorzy:
Jakubaszek, Anita
Powiązania:
https://bibliotekanauki.pl/articles/1838101.pdf
Data publikacji:
2020
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
waste water treatment
constructed wetland
nitrogen
phosphorus
oczyszczalnie ścieków
oczyszczalnia hydrofitowa
azot
fosfor
Opis:
High effectiveness of organic pollutants and nutrients removal is achieved in biological wastewater treatments plants – in case of proper exploitation of these objects. Nitrogen and phosphorus transformation or removal depends on many physic – chemical and biochemical conditions, deposit and environmental factors. A rule for treating wastewater consists in decomposition of organic compounds included in wastewater in water-soil environment. Removing contaminations is performed as a result of sorption of contaminations, bio-chemical oxidation-reduction reactions and biological activity of soil microorganisms and hydrophyte flora. The research has been carried out in the constructed wetland in Małyszyn (1300 EP). The treatment plant operates in horizontal system, with under-surface flow of wastewater.
Źródło:
Civil and Environmental Engineering Reports; 2020, 30, 2; 247-257
2080-5187
2450-8594
Pojawia się w:
Civil and Environmental Engineering Reports
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Performance of subsurface vertical flow constructed wetlands receiving municipal wastewater
Autorzy:
Kowalik, P.
Mierzejewski, M.
Randerson, P. F.
Williams, H. G.
Powiązania:
https://bibliotekanauki.pl/articles/241164.pdf
Data publikacji:
2004
Wydawca:
Polska Akademia Nauk. Instytut Budownictwa Wodnego PAN
Tematy:
constructed wetland
municipal wastewater
nitrogen
Phragmites australis
phosphorus
sewage
suspended solids
wastewater treatment
Opis:
The efficiency of pollution removal from municipal sewage in two vertical flow constructed wetlands consisting of gravel filters with a surface area of 4 × 5 m, depth 60 cm, planted with reed (Phragmites) was assessed over a period of about two years. The flow of wastewater was 50 mm per day. Wastewater underwent only primary treatment before application to reed bed B, but reed bed A was supplied with wastewater after mechanical and biological treatment. Measurements were taken of sewage supply and discharge, precipitation and wastewater temperatures. The main indicator of efficiency was the elimination of suspended solids, BOD5, nitrogen and phosphorus from the wastewater during treatment. The elimination of the pollution load was 2-25g O2 per square meter per day for the BOD5 and 0-3.5 g per square meter per day for so-called "total nitrogen". Rates of pollution removal were between 2 and 4 times as high in bed B (after primary treatment) as in bed A (after biological treatment), but the loading rate of bed B was also substantially higher. The rate of BOD5 removal and the coefficient k for BOD5 were greatly dependent on temperature for reed bed B (primary treatment); less so for bed A (biological treatment). The difference between summer and winter temperatures indicates that the surface area of constructed wetland B with wastewater after mechanical treatment should be about 3 times greater during winter, to obtain the summer rate of BOD5 pollution removal in the climatic conditions of Northern Poland (54oN).
Źródło:
Archives of Hydro-Engineering and Environmental Mechanics; 2004, 51, 4; 349-370
1231-3726
Pojawia się w:
Archives of Hydro-Engineering and Environmental Mechanics
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Ekologiczne rozwiązanie gospodarki ściekowej i grzewczej w monasterze w Zwierkach
Ecological sewage management solution and heating in the monastery in Zwierki
Autorzy:
Ignatowicz, K.
Smyk, J
Powiązania:
https://bibliotekanauki.pl/articles/399716.pdf
Data publikacji:
2014
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
przydomowa oczyszczalnia ścieków
oczyszczalnia hydrofitowa
proekologiczne systemy grzewcze
wastewater treatment plants
constructed wetland
environmentally friendly heating systems
Opis:
Przedstawione w pracy badania dotyczą oceny efektywności działania przydomowej oczyszczalni ścieków ze złożem hydrofitowym w Zwierkach. W ściekach pobranych z poszczególnych etapów oczyszczania wykonano analizy BZT5, ChZT, form azotu i fosforu. Na podstawie uzyskanych wyników stwierdzono dużą skuteczność usuwania BZT5, ChZT, azotu amonowego i fosforanów. W pracy zaproponowano także zastosowanie ekologicznego rozwiązania systemu grzewczego oraz redukcję kosztów poprzez modernizację systemu przygotowania ciepłej wody użytkowej w klasztorze w Zwierkach. Założenie przewiduje wspomaganie procesu przygotowania ciepłej wody użytkowej od kwietnia do września za pomocą systemu solarnego w układzie pośrednim, a tym samym częściowe zastąpienie energii pozyskiwanej ze źródeł konwencjonalnych – w tym przypadku z paliwa jakim jest ekogroszek – energią słoneczną pozyskiwaną przez system solarny.
The study focused on the effectiveness of household sewage treatment plant in Zvierki. Were tested wastewater from the septic tank, the well with a diffuser, from the well of sludge, wastewater after filtration through filter with plants and the receiver of treated sewage – the pond. Checked the ability to remove a treatment with respect to BOD5, COD, ammonia nitrogen, nitrates and phosphates. Based on the results high efficiency removal of BOD5, COD, ammonia nitrogen and phosphate. Unfortunately, there was no reduction of nitrates – there has been a significant increase in this ratio from baseline. After comparing the final values to the limit values defined in the Polish legislation, it was found that the test treatment works in accordance with the requirements except for total phosphorus. Proposed reduction of costs through modernization of the domestic hot water in a monastery in Zvierki. The assumption provides support for the process of preparing hot water from April to September, with the solar system in the intermediate system, and thus the partial replacement of energy from conventional sources – in this case, the fuel which is coal – solar energy produced by the solar system.
Źródło:
Inżynieria Ekologiczna; 2014, 40; 7-16
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Survey of plant species present on constructed wetlands in Opalenica municipality
Analiza i porownanie wybranych przydomowych oczyszczalni hydrofitowych na terenie Gminy Opalenica
Autorzy:
Zmirek, M
Gawronski, S.
Powiązania:
https://bibliotekanauki.pl/articles/81657.pdf
Data publikacji:
2009
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
plant species
constructed wetland
Wielkopolska region
Opalenica municipality
village
macrophyte species
small community
waste water treatment
rural community
environment protection
Źródło:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation; 2009, 41, 2; 143-152
0208-5771
Pojawia się w:
Annals of Warsaw University of Life Sciences - SGGW. Land Reclamation
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Wpływ wybranych makrofitów na skuteczność oczyszczania ścieków w stokowych złożach filtracyjnych gruntowo-roślinnych
Influence of selected macrophytes on sewage treatment effectiveness in the slope soil-vegetation filtration beds
Autorzy:
Jucherski, A.
Walczowski, A.
Powiązania:
https://bibliotekanauki.pl/articles/239182.pdf
Data publikacji:
2012
Wydawca:
Instytut Technologiczno-Przyrodniczy
Tematy:
oczyszczalnia hydrofitowa
stokowe złoże gruntowo-roślinne
skuteczność oczyszczania ścieków
makrofity
constructed wetland
slope soil-vegetation bed
sewage treatment efficiency
macrophytes
Opis:
Celem wieloletnich badań była ocena wpływu monokulturowych nasadzeń manny mielec (Glyceria maxima (Hartm.) Holmb.), mozgi trzcinowatej (Phalaris arundinacea L.) i trzciny pospolitej (Phragmites australis) na skuteczność oczyszczania ścieków bytowych w poletkowych segmentach złóż filtracyjnych oraz wybór rośliny najbardziej przydatnej do stosowania na stokowych złożach gruntowo-roślinnych, opracowanych w GCB w Tyliczu. Manna mielec wykazała najlepszą kondycję botaniczną, dobre wskaźniki ewapotranspiracji (7,9 dm3*m-2*d-1) oraz najlepszą średnią wieloletnią skuteczność oczyszczania ścieków, zarówno w składnikach biogennych zanieczyszczeń (92,9% - Ncałk. i 87,4% - P-PO4), jak i we wskaźnikach BZT5 (90,6%) i ChZT (87,9%). Trzcina, ze względu na nadmierną ekspansję korzeniową, stwarza niebezpieczeństwo zagęszczania i wypierania mineralnych składników złóż, natomiast mozga trzcinowata jest mało stabilna pod względem kondycji biologicznej, a jej wpływ na skuteczność oczyszczania ścieków w złożu najmniejszy.
The aim of presented long-term research was to evaluate the influence of particular monocultures: reedgrass (Glyceria maxima Hartm.), reed Canary grass (Phalaris arundinacea L.) and common reed (Phragmites australis), on the effectiveness of household sewage treatment in the plot segments of filtration beds, and to select the most useful plant to be cultivated on slope type soil-vegetation filter beds (constructed wetland) of theTylicz system. The plot overgrown with reed grass showed the best botanical condition, good evapotranspiration rate (7.9 dm3*m-2 per day) and the highest long-term average effectiveness of sewage treatment, both in nutrient components (92.9% Ntot. and 87.4% P-PO4), as well as BOD (90.6%) and COD (87.9%) rates. The common reed, because of its exaggerated root proliferation, creates a danger of thickening and replacing mineral components of the bed. On the other hand, the reed canary grass is biologically unstable and its influence on the effectiveness of sewage treatment in constructed wetland proved to be the least.
Źródło:
Problemy Inżynierii Rolniczej; 2012, R. 20, nr 1, 1; 115-124
1231-0093
Pojawia się w:
Problemy Inżynierii Rolniczej
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie frakcji CHZT w ściekach surowych dopływających do małych i dużych oczyszczalni ścieków
Comparison of the fractions of cod in raw wastewater influent for small and large sewage treatment
Autorzy:
Smyk, J.
Ignatowicz, K.
Powiązania:
https://bibliotekanauki.pl/articles/401888.pdf
Data publikacji:
2016
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
frakcje ChZT
małe oczyszczalnie ścieków
złoża biologiczne
oczyszczalnia hydrofitowa
oczyszczalnia z osadem czynnym
COD fractions
small sewage treatment plants
rotary biological contactor
constructed wetland
treatment with activated sludge
Opis:
W artykule przedstawiono porównanie udziału frakcji ChZT w ściekach surowych w oczyszczalniach do których spływają małe ilości ścieków oraz oczyszczalnię z dużym przepływem. Porównano oczyszczalnię hydrofitową o średniej przepustowości 4 dm3/m, oczyszczalnię ze złożami biologicznymi o średniej przepustowości 8 dm3/m, oraz oczyszczalnię ścieków z osadem czynnym w Białymstoku o przepustowości około 70 000 m3/d. Najniższe udziały procentowe frakcji rozpuszczonych związków biologicznie nierozkładalnych SI w ściekach surowych odnotowano w małych oczyszczalniach ścieków. Na podstawie dostępnych danych niestwierdzono istotnych zależności między frakcjami XI, SS, XS w ściekach surowych a ilością wytwarzanych ścieków.
The article presents a comparison of the share fraction of COD in raw wastewater in treatment plants which flow in a small amount of wastewater and the sewage treatment with high flow. Compared the constructed wetlands with an average capacity of 4 dm3/m,, the treatment plant with biological deposits with an average capacity of 8 dm3/m, and a sewage treatment plant with activated sludge in Bialystok with a capacity of about 70 000 dm3/m. The lowest percentages of dissolved fraction of soluble organic non-biodegradable substances SI was reported in raw sewage in small sewage treatment plants. Based on the available data wasn’t found significant correlation between the factions XI, SS, XS in raw sewage and the amount of wastewater.
Źródło:
Inżynieria Ekologiczna; 2016, 48; 191-195
2081-139X
2392-0629
Pojawia się w:
Inżynieria Ekologiczna
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-11 z 11

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies