Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "cobalt alloys" wg kryterium: Wszystkie pola


Wyświetlanie 1-7 z 7
Tytuł:
Corrosion Resistance and Microstructure of Recasting Cobalt Alloys Used in Dental Prosthetics
Autorzy:
Loch, J.
Krzykała, A.
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/380935.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
investment casting technology
ceramic moulds
dental prosthetics
cobalt alloys
corrosion resistance
technologia odlewania
formy ceramiczne
protetyka stomatologiczna
stopy kobaltu
odporność na korozję
Opis:
The work presents the results of the studies of Co-Cr-Mo casting alloys used in the production of frame casts of removable dentures, crowns and bridges in dental prosthetics. The studies were performed on four Co-Cr-Mo alloys of different contents of Mo, W and other additives. Electrochemical tests were performed, which aimed at examining the corrosion resistance of the alloys and observing the alloy structure after chronoamperometric tests with the potential in the area of the occurrence of the passive layer breakpoint. The alloy microstructure images after chronoamperometric tests show the presence of non-uniformly distributed general corrosion. Moreover, a project of cobalt alloy casting was elaborated using a ceramic mold casting. Additionally, analysis of the obtained microstructure was performed. The microstructure of the examined alloys was of the dendrite type. This microstructure was chemically inhomogeneous and consisted of an austenitic matrix formed by a solid cobalt solution and chromium in the core dendritic structure.
Źródło:
Archives of Foundry Engineering; 2017, 17, 2; 63-68
1897-3310
2299-2944
Pojawia się w:
Archives of Foundry Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Badania tribologiczne stopów kobaltu stosowanych jako biomateriały
Tribological research of cobalt alloys used as biomaterials
Autorzy:
Karpiński, R.
Walczak, M.
Śliwa, J.
Powiązania:
https://bibliotekanauki.pl/articles/101804.pdf
Data publikacji:
2015
Wydawca:
Politechnika Lubelska. Polskie Towarzystwo Promocji Wiedzy
Tematy:
stopy kobaltu
biomateriały
tribologia
cobalt alloys
biomaterials
tribology
Opis:
Poniższe opracowanie zawiera informacje dotyczące stopów kobaltu stosowanych w stomatologii oraz medycynie. Praca zawiera przegląd literatury opisujący ogólne właściwości stopów kobaltu. Opisano także wpływ warunków wytwarzania i wykorzystywanych dodatków stopowych na strukturę oraz właściwości mechaniczne tych stopów. W opracowaniu umieszczona została metodyka przeprowadzonych badań oraz uzyskane wyniki. Do badań wybrane zostały dwa stopy na osnowie kobaltu Co-CrMo-W oraz Co-Cr-Ni-Mo. Pierwszy z nich wytworzony został techniką odlewniczą drugi natomiast wyniku obróbki plastycznej. Przeprowadzona została analiza składu chemicznego, a następnie badania tribologiczne in vitro zrealizowane na tribotesterze typu „ball-on-disc”. Przedstawiona została porównawcza charakterystyka tribologiczna tych stopów.
This study provides information about the cobalt alloys used in dentistry and medicine. The work includes a review of the literature describing the general properties of cobalt alloys. In addition it describes the impact of the manufacturing conditions and alloy additives used , on the structure and mechanical properties of these alloys. The research methodology and the results obtained has been presented in the study. Two cobalt-based alloys Co-CrMo-W and Co-Cr-Ni-Mo were selected for the tests. The first one was prepared with the use of casting technique whereas the second was obtained due to plastic forming. An analysis of the chemical composition and in vitro tribological tests with the use of tribotester of "ball-on-disc" type was conducted. Comparative tribological characteristics of these alloys has been presented.
Źródło:
Journal of Technology and Exploitation in Mechanical Engineering; 2015, 1, 1-2; 17-32
2451-148X
Pojawia się w:
Journal of Technology and Exploitation in Mechanical Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Research on resistance to corrosive wear of dental CoCrMo alloy containing post-production strap
Badanie odporności na zużycie korozyjne stomatologicznego stopu CoCrMo zawierającego złom poprodukcyjny
Autorzy:
Beer-Lech, K.
Surowska, B.
Powiązania:
https://bibliotekanauki.pl/articles/1365888.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
corrosive wear
cobalt alloys
post-production scrap
zużycie korozyjne
stopy kobaltu
złom poprodukcyjny
Opis:
Use of metal base dental prostheses is accompanied by not only wear due to biomechanical loads that occur during the process of chewing, but also by corrosive wear occurring in aggressive oral environment. Corrosive wear of metal elements of prosthesis may result in excluding it from further use by the occurrence of allergic or even carcinogenic reactions in patient, resulting from the release of toxic metal ions into the body. A common practice in prosthetic laboratories used in order to reduce production costs of dental prostheses is using so-called post-production scrap to subsequent castings. This scrap constitute the elements of casting channels, defectively made skeletons of prostheses or metal residues after prosthetic treatment. Use of post-production scrap to manufacture components to fulfill such high performance criteria (presence of complex biomechanical loads), and in particular taking into account the evaluation of biocompatibility, is the subject of discussion not only in the environment of scientists, but also the producers of dental alloys.The aim of the study was to investigate resistance to corrosive wear of dental cobalt alloy containing post-production scrap. The commercial dental alloy Wironit extra-hard with cobalt matrix has been used in this research. The study was based on a conducted polarity by means of potentiodynamic method in a solution of artificial saliva. Tested alloy samples, containing different percentage intake of post-production scrap, were cast by two casting methods - centrifugal and vacuum-pressure. Average values of parameters of Wironit extra – hard alloy resistance to corrosive wear: corrosion potential – Ecor , corrosion current Icor, polarisation resistance Rpol and pitting potential – Epit were determined. In order to assess alloy surface after corrosion microscopic observation was made. The results of research confirm high resistance of alloy to corrosive wear in environment of artificial saliva. Castings made using centrifugal methods provide lower current density in the passive state than those carried out by vacuum – pressure method, which suggests greater durability of passive layer confirmed by analysis of microstructure of samples after corrosion. Determination of correlation between content of post-production scrap and resistance to corrosion is ambiguous.
Eksploatacji stomatologicznych protez na podbudowie metalowej towarzyszy nie tylko zużycie wskutek obciążeń biomechanicznych, występujących podczas procesu żucia, ale również zużycie korozyjne mające miejsce w agresywnym środowisku jamy ustnej. Zużycie korozyjne metalowych elementów protezy skutkować może wyłączeniem jej z dalszego użytkowania wskutek wystąpienia u pacjenta reakcji alergicznych lub nawet kancerogennych, będących rezultatem uwalniania do organizmu toksycznych jonów metali. Częstą praktyką w laboratoriach protetycznych stosowaną w celu obniżania kosztów produkcji protez jest stosowanie tzw. złomu poprodukcyjnego do kolejnych odlewów. Złom ten stanowią elementy kanałów odlewniczych, wadliwie wykonane szkielety protez bądź metalowe pozostałości po obróbce protetycznej. Zastosowanie złomu poprodukcyjnego do wytwarzania elementów mających spełniać tak wysokie kryteria eksploatacyjne (występowanie złożonego stanu obciążeń biomechanicznych), a zwłaszcza biorąc pod uwagę ocenę biokompatybilności otrzymanych wyrobów, jest tematem dyskusyjnym nie tylko w środowisku naukowców, ale również i samych producentów stopów stomatologicznych. Celem pracy było zbadanie odporności na zużycie korozyjne stomatologicznego stopu kobaltu zawierającego złom poprodukcyjny. Do badań zastosowano komercyjny stop stomatologiczny Wironit extra – hard na osnowie kobaltu. Badanie polegało na przeprowadzeniu polaryzacji metodą potencjodynamiczną w środowisku roztworu sztucznej śliny. Próbki stopu poddane badaniu, zawierające różny udział procentowy złomu poprodukcyjnego, odlane zostały dwiema metodami odlewniczymi - odśrodkową i próżniowo-ciśnieniową. Wyznaczono średnie parametrów określających odporność stopu Wironit extra – hard na zużycie korozyjne: potencjał korozji – Ekor, prąd korozji Ikor, opór polaryzacyjny Rpol i potencjał przebicia – Epit. W celu oceny powierzchni stopu po korozji dokonano obserwacji mikroskopowych. Wyniki badań potwierdzają dużą odporność stopu na zużycie korozyjne w środowisku sztucznej śliny. Odlewy wykonane za pomocą metody odśrodkowej cechują się niższą gęstością prądu w stanie pasywnym niż te wykonane metodą próżniowo – ciśnieniową, co sugeruje większą trwałość warstwy pasywnej potwierdzoną analizą mikrostruktury próbek po korozji. Wyznaczenie zależności pomiędzy zawartością złomu poprodukcyjnego a odpornością na korozję jest niejednoznaczne.
Źródło:
Eksploatacja i Niezawodność; 2015, 17, 1; 90-94
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Effect of recasting on the useful properties CoCrMoW alloy
Wpływ powtórnego przetapiania na właściwości użytkowe stopu CoCrMoW
Autorzy:
Walczak, M.
Pieniak, D.
Niewczas, A. M.
Powiązania:
https://bibliotekanauki.pl/articles/301158.pdf
Data publikacji:
2014
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
stopy kobaltu
trwałość aparatów protetycznych
powtórne przetapianie
cobalt alloys
durability of prosthetic devices
recasting
Opis:
Przetapianie uprzednio odlanego metalu może spowodować zmianę składu chemicznego nowopowstałego materiału, co w końcowym efekcie może oddziaływać na właściwości użytkowestopu stomatologicznego. Do badań zastosowano stop stomatologiczny CoCrMoW o nazwie handlowej Remanium 2001.Przygotowano 3 grupy stopu stomatologicznego przez zmieszanie 50% fabrycznie nowego stopu ze stopem po poprzednim przetopieniu. Grupę pierwszą odlano w 100% z nowego fabrycznie stopu jako grupę kontrolną (R1). Grupa druga (R2) została odlana z mieszaniny jednakowych ilości nowegostopu oraz stopu odlanego tylko raz. Grupa trzecia (R3) zawierała 50% świeżego stopu oraz stopu odlanego 2 razy.Wykonano analizę mikrostrukturalną oraz składu chemicznego, badania XRD, pomiary twardości, badania tribologiczne oraz badania przyczepności wg ISO 9693.Wykazano, że w odlewaniu należy używać nowego materiału a w przypadku wykorzystania materiału wcześniej używanego należy go wymieszać z materiałem nowym.Wykorzystanie procedury przetapiania może obniżyć koszty odlewów CoCrMoW oraz może być bezpieczne w stomatologii.
Recasting of the previously cast metal can change the chemical composition of the newly formed material, which ultimately could affect the properties of a dental alloy. The research used a dental alloy CoCrMoW trade name Remanium 2001. Three groups of dental alloy were prepared by mixing 50% fresh alloy to alloy remnants from previous castings. The specimens in the first casting group used 100% fresh alloy and served as control (R1). The second group consisted of equal amounts of fresh alloy and alloy remnants cast only once (R2). The third group contained 50% fresh alloy and alloy cast twice (R3). Microstructural analysis was performed and the chemical composition, XRD studies, hardness, and tribological test and the metal–ceramic bond strength was investigated according to ISO9693 standard. New material should be used in casting, and if previously casted material is used, it should be mixed with new material. The use of the recasting procedure can lower the costs of CoCrMoW castings and can be safely in dentistry.
Źródło:
Eksploatacja i Niezawodność; 2014, 16, 2; 330-336
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
A quality assessment of casting dental prosthesis elements
Ocena jakościowa odlewanych elementów protetycznych
Autorzy:
Beer, K.
Pałka, K.
Surowska, B.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/1366170.pdf
Data publikacji:
2013
Wydawca:
Polska Akademia Nauk. Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne PAN
Tematy:
trwałość aparatów protetycznych
wady odlewnicze
stopy kobaltu
durability of prosthetic devices
casting defects
cobalt alloys
Opis:
Properties of fixed and mobile dentures, as well as their design have a significant impact on their durability in a complex state of biomechanical loads that occur in the oral cavity during the chewing process. Elements that are usually mechanical damaged (cracking) in skeletal prostheses are metal clamps. Damage of fixation of dentures not only results in the inability to further operation, but also is causing discomfort in the patient and can lead to injury of the oral cavity, teeth and risk of complications in case of access into the digestive system.The aim of this study was to evaluate the quality of items of prostheses manufactured using available techniques and the analysis of the causes of premature loss of functional quality of these elements. Dental cobalt matrix alloy - Wironit Extra-hard was used for the study. Qualitative research consisted of the evaluation of the nature and intensity of internal casting defects and evaluation of macro-and microstructure of manufactured castings using microscopic techniques. Research of breakthroughs indicate the occurrence of casting shrinkages. Microstructural research revealed the presence of a typical dendritic structure of the matrix in form of solid solution Co-Cr-Mo and eutectic. Strength test results achieved in the relation to the macro and microstructure were also carried out. A quantitative assessment of the intensity of casting defects using image analysis was realized. Potential risks of casting technology were identified and a methodology of monitoring the state of elements of dentures was proposed.
Właściwości stosowanych uzupełnień protetycznych stałych i ruchomych oraz ich konstrukcja mają istotny wpływ na ich trwałość w warunkach złożonego stanu obciążeń biomechanicznych, jakie występują w jamie ustnej w trakcie procesu żucia. Elementami, które najczęściej ulegają uszkodzeniom mechanicznym (pękaniu) w protezach szkieletowych są metalowe klamry. Uszkodzenie mocowania protezy skutkuje nie tylko brakiem możliwości jej dalszej eksploatacji, ale również jest przyczyną uczucia dyskomfortu dla pacjenta i może powodować skaleczenia jamy ustnej, uszkodzenia zębów oraz ryzyko powikłań w przypadku przedostania się do układu pokarmowego. Celem pracy była ocena jakościowa elementów protez wytwarzanych dostępnymi technikami oraz analiza przyczyn przedwczesnej utraty funkcjonalności tych elementów. Do badań zastosowano stop stomatologiczny na osnowie kobaltu Wironit Extra-hard. Badania jakościowe polegały na ocenie rodzaju i nasilenia wewnętrznych wad odlewniczych oraz ocenie makro- i mikrostruktury wytworzonych odlewów z wykorzystaniem technik mikroskopowych. Badania przełomów wskazują na występowanie rzadzizn spowodowanych skurczem odlewniczym. Badania mikrostrukturalne wykazały obecność typowej struktury dendrytycznej z osnową w postaci roztworu stałego Co-Cr-Mo i eutektyką. Wykonano również analizę wyników badań wytrzymałościowych w powiązaniu z uzyskiwaną makro i mikrostrukturą. Dokonano oceny ilościowej nasilenia wad odlewniczych wykorzystując analizę obrazu. Wskazano potencjalne zagrożenia technologii odlewania oraz zaproponowano metodykę monitorowania stanu elementów protez.
Źródło:
Eksploatacja i Niezawodność; 2013, 15, 3; 230-236
1507-2711
Pojawia się w:
Eksploatacja i Niezawodność
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Corrosion Resistance of Co-Cr-Mo Alloy Used in Dentistry
Odporność korozyjna stopu Co-Cr-Mo wykorzystywanego w stomatologii
Autorzy:
Łukaszczyk, A.
Augustyn-Pieniążek, J.
Powiązania:
https://bibliotekanauki.pl/articles/353547.pdf
Data publikacji:
2015
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
cobalt alloys
corrosion resistance
method of wasted wax
microstructure
stopy kobaltu
odporność na korozję
metoda traconego wosku
mikrostruktura
Opis:
The presented paper studies the effect of the casting technology on the corrosion resistance of Co-Cr-Mo alloy. The investigations were conducted on a commercial alloy with the brand name ARGELOY N.P SPECIAL (Co-Cr-Mo) produced by Argen as well as the same alloy melted and cast by the lost wax casting method performed by a dental technician. The corrosion behavior of the dental alloys in an artificial saliva was studied with the use of the following electrochemical techniques: open circuit potential and voltammetry. After the electrochemical tests, studies of the surface of the examined alloys were performed by means of a scanning electron microscope with an X-ray microanalyzer. The results of the electrochemical studies show that the dependence of the corrosion resistance on the microstructure associated with the recasting process is marginal. The results of the electrochemical studies of the considered alloy clearly point to their good corrosion resistance in the discussed environment.
Zbadano wpływ technologii odlewania na odporność korozyjną stopu Co-Cr-Mo. Badaniom poddano stop komercyjny o nazwie handlowej ARGELOY N.P SPECIAL (Co-Cr-Mo) firmy Argen oraz ten sam stop przetopiony i odlany przez technika dentystycznego metodą traconego wosku. Zachowanie korozyjne badanego stopu w środowisku sztucznej śliny zostało zbadane przy użyciu technik elektrochemicznych: pomiaru potencjału bezprądowego, woltamperometrii cyklicznej. Po przeprowadzeniu badań elektrochemicznych wykonano badania powierzchni badanego stopu przy pomocy elektronowego mikroskopu skaningowego z mikroanalizatorem rentgenowskim. Wyniki badań elektrochemicznych wskazują, że na odporność korozyjną oraz mikrostrukturę stopu proces powtórnego odlania wpływa jedynie w niewielkim stopniu. Wyniki badań elektrochemicznych rozpatrywanego stopu wskazują jednoznacznie na ich dobrą odporność korozyjną w rozpatrywanym środowisku.
Źródło:
Archives of Metallurgy and Materials; 2015, 60, 1; 523-528
1733-3490
Pojawia się w:
Archives of Metallurgy and Materials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Porównanie właściwości mechanicznych i mikrostruktury stomatologicznych stopów kobaltu i niklu po zastosowaniu złomu poprodukcyjnego
Comparison of mechanical properties and microstructure of cobalt and nickel dental alloys after post-production scrap application
Autorzy:
Beer, K.
Walczak, M.
Powiązania:
https://bibliotekanauki.pl/articles/284101.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
stopy kobaltu
stopy niklu
biomateriały
złom poprodukcyjny
twardość
węgliki
cobalt alloys
nickel alloys
biomaterials
post-production scrap
hardness
carbides
Opis:
Celem pracy było dokonanie analizy wpływu ilości materiału przetapianego wtórnie dodanego do fabrycznie nowego stopu na właściwości mechaniczne i mikrostrukturę stopów stomatologicznych CoCrMo oraz NiCrMo. Stopy te wykorzystywane są w stomatologii do wytwarzania podbudów metalowych protez częściowych. Ze względów ekonomicznych większość laboratoriów protetycznych korzysta z tzw. złomu poprodukcyjnego jako części wsadu do kolejnego procesu odlewania protez. Złom ten stanowić mogą metale lub ich stopy, które były już raz użyte w procesie odlewania, jak również pozostałości po obróbce protetycznej. Doniesienia literaturowe wskazują, iż procedura ta może powodować zmianę właściwości mechanicznych i mikrostrukturalnych uzyskanych odlewów i wpływać na końcową jakość wytworzonych protez. Praca ta powstała w odpowiedzi na problem uzyskiwania różnych wyników przez badaczy. Jako próbki do badań zastosowano jednokrotne przetopy stopu kobaltu i niklu o zawartości wyjściowej odpowiednio: 100, 50, 25% stopu fabrycznego oraz technologię odlewania odśrodkowego. Wykonano próbę zginania, pomiar makrotwardości oraz badania mikrostruktury. Dla badanych stopów zaobserwowano zmianę badanych właściwości mechanicznych, w zależności od udziału odpadów poprodukcyjnych. Zidentyfikowano typy faz występujące strukturze badanych stopów.
The aim of this study was to analyze the impact of the amount of remelted material added to the new alloy on mechanical properties and microstructure of CoCrMo and NiCrMo dental alloys. These alloys are used to manufacture the metal partial frameworks of the dental prostheses. For economic reasons, most dental laboratories use a post-production scrap as part of the batch for the next process of casting dentures. This scrap are metals or their alloys, which have already been used once in the casting process, as well as the residues after prosthetic treatment. Literature reports suggest that this procedure affects the mechanical and structural properties and could affect the quality of the final prosthesis. This work was created in response to the problem of getting different results by the researchers. As the test sample disposable cobalt and nickel alloys were used with a starting composition: 100, 50, 25% of the brand new material and centrifugal casting technology was applied. Bending test as well as macrohardness test and microstructural analysis were performed. For tested castings changes of the mechanical properties were noticed depending on the amount of postproduction scrap in castings. The types of phases occurring in the alloys microstructures were also identified.
Źródło:
Engineering of Biomaterials; 2013, 16, 118; 5-11
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-7 z 7

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies