Tytuł:
Chlorination of N-acetyltyrosine with HOCl, chloramines, and myeloperoxidase-hydrogen peroxide-chloride system
Autorzy:
Drabik, Grażyna
Naskalski, Jerzy
Powiązania:
https://bibliotekanauki.pl/articles/1044197.pdf
Data publikacji:
2001
Wydawca:
Polskie Towarzystwo Biochemiczne
Tematy:
chlorination
hypochlorite
N-acetyltyrosine
tyrosine chloroderivatives
Opis:
N-acetyl-L-tyrosine (N-acTyr), with the alpha amine residue blocked by acetylation, can mimic the reactivity of exposed tyrosyl residues incorporated into polypeptides. In this study chlorination of N-acTyr residue at positions 3 and 5 in reactions with NaOCl, chloramines and the myeloperoxidase (MPO)-H2O2-Cl- chlorinating system were invesigated. The reaction of N-acTyr with HOCl/OCl- depends on the reactant concentration ratio employed. At the OCl-/N-acTyr (molar) ratio 1:4 and pH 5.0 the chlorination reaction yield is about 96% and 3-chlorotyrosine is the predominant reaction product. At the OCl-/ N-acTyr molar ratio 1:1.1 both 3-chlorotyrosine and 3,5-dichlorotyrosine are formed. The yield of tyrosine chlorination depends also on pH, amounting to 100% at pH 5.5, 91% at pH 4.5 and 66% at pH 3.0. Replacing HOCl/OCl- by leucine/chloramine or alanine/chloramine in the reaction system, at pH 4.5 and 7.4, produces trace amount of 3-chlorotyrosine with the reaction yield of about 2% only. Employing the MPO-H2O2-Cl- chlorinating system at pH 5.4, production of a small amount of N-acTyr 3-chloroderivative was observed, but the reaction yield was low due to the rapid inactivation of MPO in the reaction system. The study results indicate that direct chlorination of tyrosyl residues which are not incorporated into the polypeptide structure occurs with excess HOCl/OCl- in acidic media. Due to the inability of the myeloperoxidase-H2O2-Cl- system to produce high enough HOCl concentrations, the MPO-mediated tyrosyl residue chlorination is not effective. Semistable amino-acid chloramines also appeared not effective as chlorine donors in direct tyrosyl chlorination.
Źródło:
Acta Biochimica Polonica; 2001, 48, 1; 271-275
0001-527X
Pojawia się w:
Acta Biochimica Polonica
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Comparative analysis of selected water disinfection technologies with the use of life cycle assessment
Porównawcza analiza wybranych technologii dezynfekcji wody przy wykorzystaniu środowiskowej analizy cyklu życia
Autorzy:
Jachimowski, Artur
Nitkiewicz, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/205450.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
LCA
life cycle assessment
drinking water
sodium hypochlorite
chlorination
water disinfection
UV disinfection
cykl życia
woda pitna
podchloryn sodu
chlorowanie
dezynfekcja wody
dezynfekcja UV
Opis:
The objective of the paper is to use life cycle assessment to compare environmental impact of different technologies used in the process of water disinfection. Two scenarios are developed for water disinfection life cycle at ZUW Raba water treatment plant: (1) historical, in which gaseous chlorine is used as a disinfectant and (2) actual, in which UV radiation and electrolytically generated sodium hypochlorite are used for that purpose. Primary data is supplemented with ecoinvent 3 database records. Environmental impact is assessed by IMPACT2002+ method and its midpoint and endpoint indicators that are calculated with the use of SimaPro 8.4 software. The focus of the assessment is on selected life cycle phases: disinfection process itself and the water distribution process that follows. The assessment uses the data on flows and emissions streams as observed in the Raba plant. As the results of primal analysis show, a change of disinfectant results in quantitative changes in THMs and free chlorine in water supplied to the water supply network. The results of analysis confirm the higher potential of THMs formation and higher environmental impact of the combined method of UV/NaClO disinfection in distribution phase and in whole life cycle, mainly due to the increase of human toxicity factors. However, during the disinfection phase, gaseous chlorine use is more harmful for environment. But the final conclusion states that water quality indicators are not significant in the context of LCA, while both disinfection and distribution phases are concerned.
Celem artykułu było pokazanie wykorzystania środowiskowej oceny cyklu życia (LCA) do porównania wpływu na środowisko różnych technologii stosowanych w procesie dezynfekcji wody. Dla cyklu życia procesu dezynfekcji wody w zakładzie uzdatniania wody Raba Miejskiego Przedsiębiorstwa Wodociągów i Kanalizacji (MPWiK) w Krakowie w niniejszej pracy zostały sformułowane dwa scenariusze: (1) historyczny, w którym dezynfektantem jest chlor gazowy oraz (2) bieżący, w którym tę rolę spełnia układ dwustopniowy z promieniowaniem UV i podchlorynem sodu. Podstawowe dane były uzupełniane rekordami bazy danych ecoinvent 3. Oddziaływanie środowiskowe poddano ocenie przy wykorzystaniu metody IMPACT2002+. Pośrednie i końcowe wskaźniki kategorii wpływu wyliczono przy wykorzystaniu oprogramowania SimPro 8. Analiza obejmowała wybrane fazy cyklu życia: sam proces dezynfekcji i następujący po nim proces dystrybucji wody. W ocenie wykorzystano dane ilościowe o przepływach i emisjach w procesie dezynfekcji wody z wybranego zakładu uzdatniania wody. Wyniki wstępnych analiz pokazują, że zmiana dezynfektanta powoduje zmiany ilościowe trihalometanów (THM) i chloru wolnego w wodzie dostarczanej do sieci wodociągowej. Analiza wskazuje, że w fazie dezynfekcji użycie chloru gazowego jest bardziej szkodliwe dla środowiska. Natomiast wyniki analizy potwierdzają wyższy potencjał tworzenia się THM i większy wpływ na środowisko połączonej metody dezynfekcji UV/NaClO w fazie dystrybucji wody.
Źródło:
Archives of Environmental Protection; 2019, 45, 3; 3-10
2083-4772
2083-4810
Pojawia się w:
Archives of Environmental Protection
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies