Tytuł:
Rozwazania nad metodyka instrumentalnego pomiaru barwy marchwi
Discussion about a measurement of colour of carrot
Autorzy:
Zapotoczny, P
Zielinska, M
Powiązania:
https://bibliotekanauki.pl/articles/827008.pdf
Data publikacji:
2005
Wydawca:
Polskie Towarzystwo Technologów Żywności
Tematy:
warzywa
marchew
barwa
jakosc
pomiary barwy
pomiary instrumentalne
metody pomiarow
ocena jakosci
obliczenia matematyczne
vegetable
carrot
colour
quality
colour measurement
instrumental measurement
measurement method
quality assessment
computation
Opis:
W pracy przedstawiono rozważania nad metodyką pomiaru barwy materiałów niejednorodnych na przykładzie marchwi. Korzeń marchwi był krojony na kostkę o bokach 10 x 10 x 10 mm. Pomiaru dokonano na kostkach surowych, blanszowanych oraz suszonych fluidyzacyjnie w temp. 70°C. Suszeniu poddano zarówno kostki nieblanszowane, jak i blanszowane w wodzie o temp. 95°C przez 4 min z dodatkiem trójfosforanu sodowego. Sprawdzano także wpływ rozdrabniania kostek na pomiar barwy. Barwa mierzona była w systemie L*a*b*, wyliczone zostały indeksy barwy: bezwzględna różnica barwy DE* oraz indeks żółtości YI(313). Wykazano wpływ sposobu przygotowania próbek do pomiaru na interpretację uzyskanych wyników. Przed przystąpieniem do pomiarów wyliczono minimalną liczebność próby. Minimalna liczba powtórzeń przy zakładanym błędzie pomiaru wyniosła od 15 do 36, w zależności od mierzonej składowej. Stwierdzono statystycznie istotne różnice (p = 0,05) pomiędzy składowymi barwy w kolejnych seriach pomiarowych tych samych kostek marchwi. Sposób przygotowania próbek do pomiaru miał wpływ na składowe barwy. Blanszowanie kostek, a następnie ich rozdrabnianie wpłynęło na zmniejszenie jasności barwy. Sposób przygotowania próbek marchwi poddanej suszeniu nie miał dużego wpływu na zmianę jasności barwy. Natomiast w przypadku składowych a*, b* oraz indeksu ΔE* i YI313 sposób przygotowania próbek marchwi zarówno przed, jak i po suszeniu miał znaczący wpływ na badane parametry.
This paper shows a careful examination and discussion about a measurement of colour of inhomogeneous biological materials. An example of such materials is a carrot. Samples were cut into 10 mm cubes. An instrumental method for determining the changes in colour of raw, blanched and dried carrots is used in this paper. The fluidized bed drying was used as a method of food preservation. The samples which were used to drying were divided into two parts: blanched or unblanched. The drying process was carried out under specific operating conditions: 70°C and the mean of air velocity 4.5 m/s. The blanching operation was carried out for 4 minutes in boiling water. The parameters L*, a*, b* were applied to colour description. In an instrumental evaluation of colour and description of differences between the samples the following indices can be calculated and expressed in the form of: ΔE* (total colour difference), YI (313) (index of yellowness). This paper shows the influence of sample preparation on measurement of carrot colour. The results of this study show that the sample preparation is an important and significant step in colour measurement and how it could influence on interpretation of obtained experimental results. Previously to samples preparation the number of repetition was calculated. The minimum number of repetition was from 15 to 36 on the accepted error of measurement level. It depends on measurement constituents. There were observed statistical differences (p = 0,05) between measurement constituents in the following series of the same carrot cubes measurement. It was observed that the way of sample treatment had a significant influence on constituents of colour. The blanching operation of carrot cubes and further coarse grinding had a significant influence on lightness deterioration. The way of sample treatment before drying is irrelevant and not significant for lightness. Moreover the way of sample treatments (blanching, powdering) had a significant influence on parameter a*, b* and indices: ΔE*, YI313. The way of sample treatment may play an important role for further interpretation of obtained experimental results, what is shown in discussion.
Źródło:
Żywność Nauka Technologia Jakość; 2005, 12, 1; 121-132
1425-6959
Pojawia się w:
Żywność Nauka Technologia Jakość
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-1 z 1

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies