Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "robot calibration" wg kryterium: Temat


Wyświetlanie 1-2 z 2
Tytuł:
Dual manipulator system calibration based on virtual constraints
Autorzy:
Zhu, Q.
Xie, X.
Li, C.
Powiązania:
https://bibliotekanauki.pl/articles/200227.pdf
Data publikacji:
2019
Wydawca:
Polska Akademia Nauk. Czytelnia Czasopism PAN
Tematy:
dual manipulators
calibration
virtual constraint
optical axis
robot-robot
hand-eye
Opis:
Calibration is necessary for dual manipulator to complete operational tasks. This paper proposes an effective robot-robot and hand-eye calibration method based on virtual constraints. Firstly, a rotational error model and a translational error model are established based on the relationships between the transformation matrices of the dual manipulator calibration system. Then a poses-alignment method is designed to make the poses of the two robots satisfy the constructed virtual constraints. At the aligned positions, the joint angles of the two robots are saved and used to calculate the values of the variables in the error models. Finally, the robot-robot and hand-eye rotational errors are estimated by an iterative algorithm. These errors are then used to calculate translational errors based on the SVD (singular value decomposition) method. To show the feasibility and effectiveness of the proposed method, experiments of robot-robot and hand-eye calibration for dual manipulators are performed. The experiment results demonstrate that the accuracy of the dual manipulator system is improved greatly.
Źródło:
Bulletin of the Polish Academy of Sciences. Technical Sciences; 2019, 67, 6; 1149-1159
0239-7528
Pojawia się w:
Bulletin of the Polish Academy of Sciences. Technical Sciences
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Evaluation of velocity and acceleration effect on mecanum wheel robot positioning
Autorzy:
Bączyk, Aleksander
Wojtowicz, Przemysław
Klekiel, Tomasz
Powiązania:
https://bibliotekanauki.pl/articles/2174213.pdf
Data publikacji:
2022
Wydawca:
Uniwersytet Zielonogórski. Oficyna Wydawnicza
Tematy:
robot
kalibracja
pomiar optyczny
mecanum wheel
calibration
optical measurements
Opis:
In this paper, a Mecanum wheel omnidirectional robotic platform made for taking measurements in harsh and dangerous conditions is introduced. Due to the necessity of highly accurate displacement of the platform for measuring the conditions at the exact measurement point and due to known Mecanum wheel slippage and relatively poor position accuracy, a calibration procedure for minimizing positioning error had to be implemented. For this task, a highly accurate stereographic digital image correlation (DIC) system was used to measure platform displacement. A series of parameters, namely linear maximum velocity and acceleration/deceleration values, were taken into account during the calibration procedure to find the best combination allowing precise movement of the robot. It was found that low acceleration values were the main causes of the robot’s poor positioning accuracy and could cause the robot’s motors to stall. Max speed values proved to have little effect on the robot’s positioning.
Źródło:
International Journal of Applied Mechanics and Engineering; 2022, 27, 3; 22--35
1734-4492
2353-9003
Pojawia się w:
International Journal of Applied Mechanics and Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-2 z 2

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies