Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "solid fraction" wg kryterium: Wszystkie pola


Wyświetlanie 1-5 z 5
Tytuł:
Impact of Air-Flow Rate and Biochar Addition on the Oxygen Concentration in Waste and Emitted Gases During Biostabilization of Undersized Fraction from Municipal Solid Waste
Autorzy:
Malinowski, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/1838279.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipal solid waste
biochar
intensive phase
biostabilization
oxygen concentration
Opis:
Mechanical biological treatment of waste is still one of the most popular methods for mixed municipal waste treatment. The result of mechanical processing of waste is sorting out: the undersized fraction from municipal solid waste (UFMSW) with granulation below 80 mm, rich in biodegradable organic waste (mainly including food waste, paper, wood, etc.). UFMSW is treated in biological processes in order to reduce the negative environmental effect of this waste. Unfortunately, the processing is not neutral to the environment. The correct course of the aerobic biostabilization process depends on the activity of microorganisms, the intensity of aeration, and the oxygen content in the processed waste. The aim of this paper was to analyze the effect of air-flow rate and biochar addition on the oxygen concentration in waste and in emitted gases during the intensive phase of UFMSW biostabilization. The study was performed under laboratory conditions. Six different variants of the process (without biochar addition and using 1.5; 3; 5; 10 and 20% of biochar addition) were applied. Subsequent replicates were conducted using an averaged air-flow rate of 0.1, 0.2, and 0.4 m3∙d-1∙kg dm.org-1. As a result of the conducted experiments, it was found that both the air-flow rate and the addition of biochar have a significant effect on the oxygen concentration in the treatment waste, as well as its content in the outlet air. Using the highest air-flow rate resulted in the oxygen content not decreasing below 14%, both in the free spaces between the waste and in the emitted gases, while the addition of biochar significantly reduced the oxygen concentration. In the case of lower air-flow rate values, the oxygen content decreased even below 5%. It was found that a high addition of biochar (10 and 20% by weight) at the lowest air-flow rate resulted in the occurrence of anaerobic zones in waste in the first days of the intensive process (between days 2 and 6 of the process), as well as absence of oxygen in the outlet air (between days 2 and 4 of the process). Despite this, no methane (biogas) emissions were found in any of the conducted experiments.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 136-144
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Impact of Air-Flow Rate and Biochar Addition on the Oxygen Concentration in Waste and Emitted Gases During Biostabilization of Undersized Fraction from Municipal Solid Waste
Autorzy:
Malinowski, Mateusz
Powiązania:
https://bibliotekanauki.pl/articles/1838370.pdf
Data publikacji:
2021
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
municipal solid waste
biochar
intensive phase
biostabilization
oxygen concentration
Opis:
Mechanical biological treatment of waste is still one of the most popular methods for mixed municipal waste treatment. The result of mechanical processing of waste is sorting out: the undersized fraction from municipal solid waste (UFMSW) with granulation below 80 mm, rich in biodegradable organic waste (mainly including food waste, paper, wood, etc.). UFMSW is treated in biological processes in order to reduce the negative environmental effect of this waste. Unfortunately, the processing is not neutral to the environment. The correct course of the aerobic biostabilization process depends on the activity of microorganisms, the intensity of aeration, and the oxygen content in the processed waste. The aim of this paper was to analyze the effect of air-flow rate and biochar addition on the oxygen concentration in waste and in emitted gases during the intensive phase of UFMSW biostabilization. The study was performed under laboratory conditions. Six different variants of the process (without biochar addition and using 1.5; 3; 5; 10 and 20% of biochar addition) were applied. Subsequent replicates were conducted using an averaged air-flow rate of 0.1, 0.2, and 0.4 m3∙d-1∙kg dm.org-1. As a result of the conducted experiments, it was found that both the air-flow rate and the addition of biochar have a significant effect on the oxygen concentration in the treatment waste, as well as its content in the outlet air. Using the highest air-flow rate resulted in the oxygen content not decreasing below 14%, both in the free spaces between the waste and in the emitted gases, while the addition of biochar significantly reduced the oxygen concentration. In the case of lower air-flow rate values, the oxygen content decreased even below 5%. It was found that a high addition of biochar (10 and 20% by weight) at the lowest air-flow rate resulted in the occurrence of anaerobic zones in waste in the first days of the intensive process (between days 2 and 6 of the process), as well as absence of oxygen in the outlet air (between days 2 and 4 of the process). Despite this, no methane (biogas) emissions were found in any of the conducted experiments.
Źródło:
Journal of Ecological Engineering; 2021, 22, 6; 136-144
2299-8993
Pojawia się w:
Journal of Ecological Engineering
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Dobór modelu i wyznaczanie parametrów kinetycznych aktywności oddechowej odpadów w trakcie procesu tlenowej biostabilizacji frakcji podsitowej odpadów komunalnych
Model Selection and Estimation of Kinetic Parameters of Oxygen Consumption During Biostabilization of Under-size Fraction of Municipal Solid Waste
Autorzy:
Stegenta, S.
Kałdun, B.
Białowiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/1817968.pdf
Data publikacji:
2016
Wydawca:
Politechnika Koszalińska. Wydawnictwo Uczelniane
Tematy:
biostabilizacja odpadów
frakcja podsitowa
parametry kinetyczne
zużycie tlenu
biostabilization
under-size fraction
municipal solid waste
kinetic parameters
oxygen demand
biostimulator
Opis:
Końcowym produktem procesu biostabizacji jest stabilizat, czyli odpad stały, który po biologicznym przetworzeniu, spełnia wymogi rozporządzenia Ministra Środowiska w sprawie mechaniczno-biologicznego przetwarzania zmieszanych odpadów komunalnych (Dz.U. z 2012, poz. 1052). Aby określić stopień stabilizacji odpadu, (w praktyce stopień dekompozycji materii organicznej), stosuje się wskaźniki określające aktywność biologiczną. W polskim prawie przyjęto iż jednym z parametrów wskazującym na stopień stabilizacji odpadu jest aktywność respirometryczna AT4 (rozporządzenie Dz.U. z 2012, poz. 1052). Zużycie tlenu w trakcie procesu rozkładu materii organicznej zawartej w odpadach może mieć charakter równania 0-ego lub 1-ego rzędu. Odpowiednie dopasowanie modelu do reakcji jest kluczowe aby wyznaczyć poprawnie parametry kinetyczne reakcji. Z tego względu wykonano badania, których celem było sprawdzenie stopnia dopasowania 2 modeli matematycznych do krzywej zużycia tlenu dla próbek odpadów będących w różnych fazach procesu biostabilizacji oraz zaproponowanie modelu o najwyższej użyteczności. Eksperyment przeprowadzono w skali technicznej, w instalacji do biostabilizacji odpadów, gdzie stosowany jest biopreparat bakteryjny w celu obniżenia uciążliwości odorowej. Badania wykonano w dwóch wariantach z wykorzystaniem partii odpadów zaszczepionych biopreparatem i odpadów niezaszczepionych. W trakcie procesu biostabilizacji pobierano próbki odpadów w interwałach cotygodniowych. Po pobraniu, próbki odpadów transportowane były do laboratorium, gdzie tego samego dnia rozpoczynano pomiary aktywności oddechowej metodą OxiTop®. Przeprowadzone badania wykazały, iż niezależnie od czasu trwania procesu oraz zastosowania lub niezastosowania inokulacji biopreparatem modelem najlepiej opisującym kinetykę zużycia tlenu jest model I-ego rzędu. Wykazano także, iż dodatek biopreparatu spowodował podwyższenie aktywności oddechowej odpadów w pierwszych 3 tygodniach procesu biostabilizacji.
Final product of waste biostabilization process is stabilized organic fraction. It is a solid waste, after biological process, which perform requirements of actual law regulation (Dz.U. z 2012, poz. 1052). To determine stabilization of waste degree (in practice decomposition of organic matter degree), used indicator which define biological activity. The Polish regulations adopted that one of the parameters indicating the degree of stabilization of waste, is the respiration activity index AT4. Oxygen consumption during organic matter decomposition process, could have 0-order or 1st-orderreaction character. Suitable fit of the model to react is crucial, to correctly determine the kinetic parameters of the reaction. For this reason, experiments, which purposes were to: examine the relevance of two mathematical models, to the oxygen consumption curves, for waste samples that are in various stages of the biostabilization process, and to propose a model of the highest utility, were performed. The study was conducted on an industrial scale, in operating conditions biostabilization plant, where biostimulator was used to reduce odors. Two variants, first using waste with biostimulator and second without biostimulator were tested. During the biostabilization process, samples were collected in weekly intervals. Samples of waste were transported to the laboratory, where respiratory activity was measured. Research has shown that independently of the duration of the process, and the inoculation or without -inoculation of biostimulator, the best fitting model which describes the kinetics of oxygen consumption is the first order reaction model. It was also shown that the addition of biostimulator increase respiration activity of waste during first 3 weeks of biostabilization process.
Źródło:
Rocznik Ochrona Środowiska; 2016, Tom 18, cz. 1; 800-814
1506-218X
Pojawia się w:
Rocznik Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analysis of the undersize fraction temperature changes during the biostabilization process
Autorzy:
Malinowski, M.
Powiązania:
https://bibliotekanauki.pl/articles/101271.pdf
Data publikacji:
2017
Wydawca:
Polska Akademia Nauk. Stowarzyszenie Infrastruktura i Ekologia Terenów Wiejskich PAN
Tematy:
municipal solid waste
undersize fraction
biostabilization
Opis:
Mixed municipal solid waste collected from the area of each Polish district (commune) is transferred to Regional Installations for Municipal Solid Waste Treatment. They comprise one or more of the following facilities: installations for mechanical-biological waste treatment (MBT), installations for thermal treatment of municipal solid waste, green waste composting plants and landfill sites. MBT installations have been currently the dominant technology of mixed municipal solid waste treatment in Poland. In these installations mixed waste is subjected to mechanical processes (including: crushing, separation, screening and classification) resulting in the production of the undersize fraction with usual grain size below 80mm and the oversize fraction with grain size over 80mm. Because of the necessity of stabilization and hygenization of the undersize fraction prior to landfilling, it is subjected to the process of biological treatment, e.g. biostabilization. The main aim of the research was to analyze the temperature changes during the biostabilization of the undersized fraction in thermally insulated BKB100 laboratory bioreactor. The research covered a 14-day period of the intensive phase. The analyses were performed in 6 replications. 40.1±2.2kg of waste with density of 519.2±27.5kgˑm-3 and the biodegradable fraction content of 41.9±1.9% was placed in the reactor. The temperature of waste inside the reactor was measured by 9 Pt 1000 temperature sensors. The air for the process was constantly supplied from the outside of the reactor. Flow of the supplied air with temperature of 18.3±3.1°C was regulated depending on the average indication of all temperature sensors. Results of the temperature measurements were averaged and showed using Golden Software Surfer 7. As a result of the conducted research it was found that changes in the temperature inside the bioreactor occurred uniformly throughout its full volume. The time of reaching the temperature of 45°C (the beginning of thermophilic phase) was 25.6±4.0 hours (21 hours at the earliest). During the first period the temperature in the reactor was increasing most intensively in the lower parts of the layer, in the central part of the layer the temperature reached 45°C after 34 hours at the earliest, whereas on average it took 47.7±9.9 hours. The average maximum process temperature was 64.8±3.5°C.
Źródło:
Infrastruktura i Ekologia Terenów Wiejskich; 2017, IV/3; 1773-1784
1732-5587
Pojawia się w:
Infrastruktura i Ekologia Terenów Wiejskich
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Aktywność biologiczna ustabilizowanej drobnej frakcji odpadów komunalnych podczas ich długotrwałej ekspozycji na warunki atmosferyczne
Biological activity of stabilized municipal waste fine fraction under long-lasting exposure to atmospheric conditions
Autorzy:
Stegenta, S.
Kałdun, B.
Sobieraj, K.
Białowiec, A.
Powiązania:
https://bibliotekanauki.pl/articles/237151.pdf
Data publikacji:
2017
Wydawca:
Polskie Zrzeszenie Inżynierów i Techników Sanitarnych
Tematy:
solid waste
biostabilization
under-size fraction
kinetic parameters
oxygen demand
respiration activity
odpady komunalne
biostabilizacja
frakcja podsitowa
parametry kinetyczne
zużycie tlenu
aktywność oddechowa
Opis:
One of the accepted technological solutions used in mechanical-biological waste treatment is screening of stabilized undersize fraction (code 190599) through a sieve to separate two fractions with the grain size of 20–80 mm (code 190599) and < 20 mm (code 190503 – compost that fails to comply with requirements). Fraction < 20 mm may be used for landfill remediation as a landfill cover. However, its long-lasting exposure to atmospheric conditions may have an adverse effect on microbial respiration. This phenomenon was verified in the field study and lysimetric experiment aimed to simulate landfill conditions, which lasted 10 weeks (both in winter and summer season). The lysimeters contained stabilized fine fraction, while half of the containers were additionally filled with water to reflect adverse conditions at a landfill site resulting from stagnant pond formation. Both the direct measurements and model studies confirmed a significant increase of microbial activity in hydrated waste samples. During remediation works special care should be taken to avoid stagnant pond formation on the landfill top because of the unfavourable pond conditions that facilitate decomposition of organic matter in the stabilized fine fraction. Therefore, biological stabilization of municipal solid waste should be planned to effectively lower organic matter content and minimize moisture of the under-size fraction. It was demonstrated that activity at the level of AT4 < 2 mgO2/g allowed for safe use of the stabilized fine fraction in restoration process of closed landfills.
Jednym z akceptowanych rozwiązań technologicznych mechaniczno-biologicznego przetwarzania odpadów komunalnych jest wielkościowa waloryzacja ustabilizowanej frakcji podsitowej o kodzie 190599, przez jej przesianie na sicie w celu wydzielenia dwóch frakcji – o uziarnieniu 20÷80 mm (o kodzie 190599) oraz <20 mm (o kodzie 190503 – kompost nieodpowiadający wymaganiom). Frakcja <20 mm może być wykorzystana do rekultywacji składowisk odpadów, jednakże podczas jej długotrwałej ekspozycji na warunki atmosferyczne możliwe są niekorzystne zmiany aktywności oddechowej mikroorganizmów obecnych w tej frakcji. Zjawisko to zweryfikowano w doświadczeniu polowym oraz eksperymencie lizymetrycznym, trwającym 10 tygodni (w sezonie zimowym i letnim), mającym symulować warunki panujące na składowisku. Lizymetry zawierały frakcję podsitową odpadów z procesu stabilizacji, przy czym połowę z nich wypełniono wodą, aby odzwierciedlić niekorzystne warunki w postaci zastoisk wody na powierzchni składowiska. Zarówno bezpośrednie pomiary aktywności oddechowej drobnoustrojów, jak i badania modelowe potwierdziły znacznie większą aktywność mikroorganizmów w nawodnionych próbkach odpadów. Podczas rekultywacji składowiska odpadów należy więc unikać powstawania zastoisk wody na wierzchowinie, ponieważ powstające w nich warunki wpływają na przyspieszenie rozkładu związków organicznych pozostałych w stabilizacie. Biologiczna stabilizacja odpadów komunalnych powinna zatem dążyć do skutecznego zmniejszenia zawartości związków organicznych oraz do ograniczenia wilgotności uzyskanego stabilizatu. Potwierdzono, że stosowanie materiału o aktywności AT4<2 mgO2/g pozwala na bezpiecznie użycie frakcji podsitowej do rekultywacji zamkniętych składowisk.
Źródło:
Ochrona Środowiska; 2017, 39, 4; 31-40
1230-6169
Pojawia się w:
Ochrona Środowiska
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-5 z 5

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies