Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "Niedzielski, P." wg kryterium: Autor


Wyświetlanie 1-3 z 3
Tytuł:
DLC coating doped by specified elements as a biomaterial designed for individual patient needs
Autorzy:
Bociąga, D.
Szymański, W.
Jakubowski, W.
Komorowski, P.
Niedzielski, P.
Powiązania:
https://bibliotekanauki.pl/articles/284956.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
carbon coating
doped DLC
biomaterial
biocompatibility
implant
Opis:
Currently, there are more and more new materials (nanomaterials) proposed for biological and medical applications. They are, among other things, the effect of surface modification. One of the most frequently used techniques, fairly widespread, is plasmo-chemical method of diamond-like carbon (DLC) coating fabrication. There is many alterations of them, nevertheless all are characterized by short duration of the process and its economics. The final result does not require additional finishing treatments and the required coating properties can be controlled and obtained by selecting appropriate process parameters. Good mechanical and tribological properties, high corrosion resistance and its tolerance by biological systems have been documented in the literature. However, given the very wide range of applications of biomaterials found over time that the properties of carbon coatings are not always sufficient. The research conducting by scientific centres around the world have shown, however, that surface properties can be controlled by introducing specified elements into the DLC layer. Each of these added elements causes some properties change. Taking into consideration that we are dealing with biomaterials – the materials which are used in very harsh and demanding environment of a living organism, which also have a strong intra-individual variability, the solution in the form of material designed adequately to the needs of the individual patient is even more attractive and desirable. The DLC coatings doped by silver fulfilling constitute an innovative materials for biomedical application and are the subject of our investigations.
Źródło:
Engineering of Biomaterials; 2013, 16, no. 122-123 spec. iss.; 8-9
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Biologiczna ocena warstw węglowych domieszkowanych srebrem
Biological evaluation of carbon layers doped with silver
Autorzy:
Jakubowski, W.
Komorowski, P.
Bociaga, D.
Batory, D.
Niedzielski, P.
Walkowiak, B.
Powiązania:
https://bibliotekanauki.pl/articles/286153.pdf
Data publikacji:
2012
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
warstwy węglowe
inżynieria materiałowa
biozgodność
carbon layers
materials engineering
biocompatibility
Opis:
Postęp w naukach biologicznych i medycznych jest obecnie coraz silniej uzależniony od gromadzenia i poddawania analizie informacji o wzajemnych relacjach między komórkami żywych organizmów a powierzchniami materiałów abiotycznych. Szczególnie istotne jest to w dziedzinach związanych z wykorzystaniem biomateriałów, ale taka zależność jest też silnie widoczna w obszarze obejmującym przemysł przetwórczo-spożywczy. Oddziaływania materiał - komórka żywa, w znacznej mierze wykraczają poza dotychczas postrzegany zakres standardowego wykorzystania biomateriałów, a odkrycia na polu interakcji powierzchni materiałów z komórkami mają coraz większe znaczenie w prawidłowym użytkowaniu nowoczesnych systemów dystrybucji wody pitnej, a także przemysłowych systemów chłodzenia i obiegu cieczy. Wspomniany postęp stawia kolejne wyzwania przed inżynierią materiałową, która odpowiada za opracowywanie nowych technologii i materiałów mających spełniać coraz bardziej rygorystyczne oczekiwania użytkowników. Lepsze zrozumienie zależności w jakich pozostaje układ środowisko - organizmy żywe - materiał inżynierski prowadzą do wyeliminowania materiałów stwarzających potencjalnie zagrożenie, z jednoczesnym wprowadzeniem nowych materiałów, lepiej spełniających swoje funkcje. W procesie opracowania materiałów o wysokiej biozgodności uwagę naukowców w dużej mierze skupia grupa problemów związanych z zasiedlaniem powierzchni abiotycznych przez mikroorganizmy. Ograniczenie lub wyeliminowanie procesu kolonizacja powierzchni biomateriałów, zwykle prowadzącego do rozwinięcia się trudno zwalczanego biofilmu, stanowi istotne wyzwanie dla nowoopracowywanych biomateriałów. W literaturze fachowej dostrzegane są niekorzystne efekty, obserwowane przede wszystkim w praktyce klinicznej, do jakich doprowadza rozwiniecie się biofilmu na powierzchniach implantów. Opisywany jest także efekt wzrostu oporności takich kolonii bakteryjnych na działania układu immunologicznego oraz farmakoterapię. Jedną z możliwych modyfikacji powierzchni, pozwalających na ograniczenie zasiedlania ich przez mikroorganizmy, jest wprowadzenie elementów o działaniu bakterio- i grzybobójczym. W Instytucie Inżynierii Materiałowej opracowany został materiał, wytwarzany metodą hybrydową RF PACVD/MS, łączący bioinertny charakter warstw węglowych z bakteriobójczymi właściwościami jonów srebra. Powłoka tego typu pozwala na znaczące ograniczenie adhezji bakterii prowadzącej do rozwoju biofilmu na powierzchni materiału, przy jednoczesnej znikomej cytotoksyczności dla komórek organizmów wyższych. Wyniki eksperymentów prowadzonych z wykorzystaniem modelowych hodowli bakterii E.coli (DH5a) oraz komórek ludzkich osteoblastów (Saos 2) i komórek śródbłonka (EA.hy 926) w pełni potwierdziły zakładane właściwości nowego materiału.
Progress in biological sciences and medicine is today increasingly dependent on collecting and examining information on the relationship between the cells of living organisms and abiotic surfaces of different materials. This is especially important in areas related to the use of biomaterials, and this dependence is particularly evident in certain areas such as the food industry. Interactions between material - living cells, has until recently been largely considered outside the scope of the standard use of biomaterials. The discovery of cell interactions with material surfaces are of growing importance in the proper use of modern drinking water distribution systems, industrial cooling systems and fluid circulation. This progress poses new challenges for materials engineering, which is responsible for the development of new technologies and materials that must meet increasingly stringent standards. With a better understanding of relationships present in such a system: environment - living cells - material engineering, it will be possible to eliminate any materials that poses a potential threat, and introduce new materials, that perform their functions more efficiently. In the process of developing materials with high a degree of biocompatibility, much of the research has focused on the problem of abiotic surface colonization by different microorganisms. One of the most significant challenges in developing new biomaterials is the reduction or elimination of biomaterial surface colonization, which usually leads to the development of a biofilm. In the literature the adverse effects of such interactions have been observed, primarily in clinical practice and the development of biofilms on the surface of implants. Increased resistance of these bacterial colonies to the human immune system and drug therapy has also been described. One possible material surface modification, which could reduce microorganism colonization, is the introduction of elements that exhibit bactericidal and fungicidal activity. The Institute of Materials Engineering has developed a material produced using a hybrid method RF PACVD/MS, which combines the bioinert nature of carbon layers and the bactericidal properties of silver ions. Such a coating can significantly reduce the degree bacterial adhesion, which results in the development of a biofilm on the surface materials, whilst having a negligible cytotoxic effect on the cells of higher organisms. Results of experiments conducted using the model bacterium E. coli culture (DH5a) together with human osteoblastic (Saos 2) and endothelial cells (EA.hy 926) have fully confirmed the assumed properties of this new material.
Źródło:
Engineering of Biomaterials; 2012, 15, no. 116-117 spec. iss.; 89
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Materiały polimerowe i węglowe w aspekcie zastosowania jako materiał konstrukcyjny dysku polskiej mechanicznej zastawki serca - ocena wybranych własności fizycznych i biologicznych
Polymeric and carbon materials applied in the construction of Polish mechanical valve disk - evaluation of selected physical and biological properties
Autorzy:
Szuber, A.
Kościelniak-Ziemniak, M.
Janiczak, K.
Głowacki, M.
Gawlikowski, M.
Kustosz, R.
Gonsior, M.
Wilczek, P.
Duber, S.
Kaczorowski, W.
Niedzielski, P.
Grabarczyk, J.
Walke, W.
Powiązania:
https://bibliotekanauki.pl/articles/284095.pdf
Data publikacji:
2013
Wydawca:
Akademia Górniczo-Hutnicza im. Stanisława Staszica w Krakowie. Polskie Towarzystwo Biominerałów
Tematy:
dysk mechanicznej zastawki serca
biomateriały
biozgodność
mechaniczne wspomaganie serca
mechanical heart valve disc
biomaterials
biocompatibility
mechanical heart support
Opis:
Badania biomateriałów polimerowych i węglowych prowadzone są w celu doboru odpowiednich materiałów konstrukcyjnych dla polskiej dyskowej mechanicznej zastawki serca typu Moll. W obszarze zainteresowania znalazły się: polieteroeteroketon (PEEK), PEEK utwardzony powierzchniowo warstwą węglową typu DLC oraz węgiel szklisty. Biomateriały zostały poddane wybranym badaniom strukturalnym (badaniom mikrotwardości metodą Vickersa i porowatości z wykorzystaniem analizatora Autosorb iQ) oraz badaniom własności mechanicznych na stanowisku badań zmęczeniowych. Własności biozgodne biomateriałów oceniono wykorzystując nowoczesną metodę badań biologicznych biomateriałów - badania trombogenności powierzchni wykonano na urządzeniu Impact-R, w testach dynamicznego kontaktu z krwią w warunkach oddziaływania sił ścinających. Wyniki badań zmęczeniowych i oceny trombogenności materiałów polimerowych potwierdziły właściwe zastosowanie materiału PEEK w konstrukcji dysku zastawki mechanicznej przeznaczonej do stosowania krótkoterminowego (około 12 miesięcy) wpozaustrojowej pulsacyjnej pompie mechanicznego wspomagania serca. Zastosowanie utwardzającej powłoki węglowej typu DLC na polimerze stanowi właściwy kierunek prac mających na celu uzyskanie bardziej wytrzymałej powierzchni dysku w kontakcie z tytanowym pierścieniem zastawek, co potwierdziły testy zmęczeniowe. Przeprowadzone badania mikrotwardości biomateriałów wskazały wysoką wytrzymałość oraz twardość opracowywanego węgla szklistego.
The polymeric and carbon biomaterials tests are performed in order to select the proper constructional materials for Polish mechanical tilting valve type Moll. In the area of interests are: polyetheretherketone (PEEK), PEEK with a DLC (diamond like carbon) surface layer and glassy carbon. The biomaterials were analyzed in selected structural tests (micro hardness tests utilizing Vickers method and porosity tests utilizing Autosorb iQ analyzer) and mechanical properties investigation on the fatigue test stand. Biocompatibility properties of biomaterials were evaluated utilizing new biological investigation method - biomaterial surface thrombogenicity test performed using Impact-R device, in the dynamic blood contact conditions with shear stress impact. The results of fatigue and thrombogenicity tests of polymeric materials confirmed the proper PEEK use in the mechanical valve disk construction dedicated for short term application (approximately 12 months) in the extracorporeal pulsatile ventricular heart assists device. The hardened carbon type DLC surface layer on the polymer is the appropriate direction of investigation in order to obtain more durable disk surface in the contact with titanium valve housing, what was confirmed in fatigue tests. The micro hardness biomaterials tests showed high strength and hardness of investigated glassy carbon.
Źródło:
Engineering of Biomaterials; 2013, 16, 121; 25-32
1429-7248
Pojawia się w:
Engineering of Biomaterials
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-3 z 3

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies