Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Wyszukujesz frazę "battery supply" wg kryterium: Temat


Wyświetlanie 1-4 z 4
Tytuł:
Analiza pracy źródła zasilania elektrycznego autobusu miejskiego
Analysis of operate of the power supply source for the city bus
Autorzy:
Biernacki, M.
Majewski, P.
Powiązania:
https://bibliotekanauki.pl/articles/1197569.pdf
Data publikacji:
2018
Wydawca:
Sieć Badawcza Łukasiewicz - Instytut Napędów i Maszyn Elektrycznych Komel
Tematy:
autobus miejski
akumulator
źródło energii
city bus
battery
power supply source
Opis:
The paper involved the analysis of road tests used for the research of newly designed drive systems of city buses. An own model of the bus test route was developed based on one of the standardized bus cycles in urban conditions and real data collected on the basis of multiple journeys by one of the routes, between end stops, served by public transport in one of the largest cities in Poland. The electric energy storages operate have analyzed taking in to account of the vehicle range requirements (according to the needs of the municipal transport plant and taking into account the current technical capabilities), durability and mass of the Energy source, time needed to charge the source after the one cycle or driving cycles. For economic reasons, apart from currently the most commonly used lithium-ion or lithium-polymer type energy storage, other types of Energy sources, less beneficial from the point of view of energy accumulating (mass), have been taken into account. The purpose of this paper is to determine of the electric energy source operating regime and develop guidelines for the selection of parameters of the source which are important from the point of view exploitation and analysis of its durability depending on the assumed parameters of the traffic of the public transport vehicle (bus) in urban conditions. In addition, the this paper purpose is to draw attention to other energy storage technologies, sometimes much cheaper than currently used, and in appropriate conditions possible to apply.
W pracy wykonano analizę testów drogowych stosowanych między innymi do badań nowoprojektowanych układów napędowych autobusów miejskich. Został opracowany własny model trasy testowej autobusu na bazie jednego ze znormalizowanych cykli jazdy autobusu w warunkach miejskich oraz rzeczywistych danych zebranych na podstawie wielokrotnego przejazdu jedną z tras obsługiwanych przez komunikację miejską w jednym z największych miast w Polsce, między przystankami krańcowymi. Przeanalizowano pracę zasobników energii elektrycznej pod kątem wymagań odnośnie zasięgu pojazdu (według potrzeb zakładu komunikacji miejskiej i uwzględnieniu aktualnych możliwości technicznych), trwałości i masy źródła energii, czasu potrzebnego na naładowanie źródła po cyklu bądź cyklach jazdy. Ze względów ekonomicznych poza obecnie najczęściej stosowanymi zasobnikami energii typu litowo-jonowego, czy litowo-polimerowego, wzięto pod uwagę inne typy źródeł energii, mniej korzystne z punktu widzenia gromadzenia energii (z uwagi na masę). Celem pracy jest określenie charakteru pracy elektrycznego źródła energii oraz opracowanie wytycznych doboru parametrów źródła energii istotnych z punktu widzenia eksploatacji oraz analiza jego trwałości w zależności od założonych parametrów ruchu pojazdu komunikacji zbiorowej (autobusu) w warunkach miejskich. Ponadto, praca ma na celu zwrócenie uwagi na inne technologie wykonania zasobników energii, niekiedy znacznie tańsze niż obecnie wykorzystywane, a w odpowiednich warunkach możliwe do zastosowania.
Źródło:
Maszyny Elektryczne: zeszyty problemowe; 2018, 2, 118; 23-28
0239-3646
2084-5618
Pojawia się w:
Maszyny Elektryczne: zeszyty problemowe
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Analiza pracy źródła zasilania elektrycznego autobusu miejskiego
Analysis of operate of the power supply source for the city bus
Autorzy:
Biernacki, Marcin
Majewski, Przemysław
Powiązania:
https://bibliotekanauki.pl/articles/302304.pdf
Data publikacji:
2019
Wydawca:
Wydawnictwo Druk-Art
Tematy:
autobus miejski
akumulator
źródło energii
city bus
battery
power supply source
Opis:
W pracy wykonano analizę testów drogowych stosowanych między innymi do badań nowo projektowanych układów napędowych autobusów miejskich. Został opracowany własny model trasy testowej autobusu na bazie jednego ze znormalizowanych cykli jazdy autobusu w warunkach miejskich oraz rzeczywistych danych zebranych na podstawie wielokrotnego przejazdu jedną z tras obsługiwanych przez komunikację miejską w jednym z największych miast w Polsce, między przystankami krańcowymi. Przeanalizowano pracę zasobników energii elektrycznej pod kątem wymagań odnośnie do zasięgu pojazdu (według potrzeb zakładu komunikacji miejskiej i uwzględnieniu aktualnych możliwości technicznych), trwałości i masy źródła energii, czasu potrzebnego na naładowanie źródła po cyklu bądź cyklach jazdy. Ze względów ekonomicznych poza obecnie najczęściej stosowanymi zasobnikami energii typu litowo-jonowego czy litowo-polimerowego, wzięto pod uwagę inne typy źródeł energii, mniej korzystne z punktu widzenia gromadzenia energii (z uwagi na masę). Celem pracy jest określenie charakteru pracy elektrycznego źródła energii oraz opracowanie wytycznych doboru parametrów źródła energii istotnych z punktu widzenia eksploatacji, a także analiza jego trwałości w zależności od założonych parametrów ruchu pojazdu komunikacji zbiorowej (autobusu) w warunkach miejskich. Ponadto praca ma na celu zwrócenie uwagi na inne technologie wykonania zasobników energii, niekiedy znacznie tańsze niż obecnie wykorzystywane, a w odpowiednich warunkach możliwe do zastosowania.
The paper involved the analysis of road tests used for the research of newly designed drive systems of city buses. An own model of the bus test route was developed based on one of the standardized bus cycles in urban conditions and real data collected on the basis of multiple journeys by one of the routes, between end stops, served by public transport in one of the largest cities in Poland. The electric energy storages operate have analyzed taking in to account of the vehicle range requirements (according to the needs of the municipal transport plant and taking into account the current technical capabilities), durability and mass of the energy source, time needed to charge the source after the one cycle or driving cycles. For economic reasons, apart from currently the most commonly used lithium-ion or lithium-polymer type energy storage, other types of energy sources, less beneficial from the point of view of energy accumulating (mass), have been taken into account. The purpose of this paper is to determine of the electric energy source operating regime and develop guidelines for the selection of parameters of the source which are important from the point of view exploitation and analysis of its durability depending on the assumed parameters of the traffic of the public transport vehicle (bus) in urban conditions. In addition, the this paper purpose is to draw attention to other energy storage technologies, sometimes much cheaper than currently used, and in appropriate conditions possible to apply.
Źródło:
Napędy i Sterowanie; 2019, 21, 2; 92-97
1507-7764
Pojawia się w:
Napędy i Sterowanie
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Estimation of efficiency of electric power balance iautomobiles
Autorzy:
Puzakov, Andrey
Powiązania:
https://bibliotekanauki.pl/articles/2098141.pdf
Data publikacji:
2021
Wydawca:
Politechnika Śląska. Wydawnictwo Politechniki Śląskiej
Tematy:
power supply system of vehicles
battery
automotive alternator
electric power balance
system zasilania pojazdów
akumulator
alternator samochodowy
bilans mocy elektrycznej
Opis:
Increase in consumer power with the simultaneous reduction in the time and driving speed of personal automobiles results in systematic discharge of the batteries due to electric power balance inefficiency. The calculation methods for the evaluation of the electric power balance are inefficient, as a number of random factors (demand for electric power, driving speed, air temperature, technical condition of the units, etc.) influence the process of electric power generation, storage and consumption. The instrumental method for evaluation of the electric power balance efficiency assumes that the driver is informed about the battery charge condition prior to combustion engine startup, operational evaluation of the charge state change is performed during automobile driving and the driver is warned about critical reduction of charge state (including the forecast of its change for the period of the parking of the automobile in winter).
Źródło:
Transport Problems; 2021, 16, 2; 113--120
1896-0596
2300-861X
Pojawia się w:
Transport Problems
Dostawca treści:
Biblioteka Nauki
Artykuł
Tytuł:
Vybor vida i obosnovanie parametrov istočnika pitaniâ sistem protivopožarnoj zaŝity obektov turističeskoj otrasti
Selection and Substantiation of the Power Supply Parameters for Fire Protection Systems Installed in Tourism Industry Buildings
Dobór sposobu i parametrów zasilania systemów ochrony przeciwpożarowej w obiektach turystycznych
Autorzy:
Bondar, G. I.
Shapovalov, O. V.
Powiązania:
https://bibliotekanauki.pl/articles/372926.pdf
Data publikacji:
2014
Wydawca:
Centrum Naukowo-Badawcze Ochrony Przeciwpożarowej im. Józefa Tuliszkowskiego
Tematy:
fire
fire protection water supply
fire protection system
battery
standalone voltage converter
pożar
instalacja wodociągowa przeciwpożarowa
system ochrony przeciwpożarowej
bateria akumulatorowa
autonomiczny przetwornik napięcia
zasilanie elektryczne
Opis:
Purpose: The article presents the issue of the effectiveness of the internal fire protection water supply systems in tourism facility buildings in terms of providing them efficient power supply in different situations and working conditions. The authors discuss the ways to tackle this issue. Introduction: The development of the tourism industry in the country together with various types of international events led to the increase in construction and reconstruction sector activity. The construction boom was provoked by the need to provide tourists with comfortable living conditions. What is more, to ensure these conditions, many objects were built in scenic locations far away from human settlements. For this reasons the buildings are confined to the limited consumption of resources such as electrical power, water and transport communications. In order to protect people and their property from fires, it is essential to ensure an uninterrupted power supply to the fire protection systems, including the internal fire protection water supply system. Having analyzed the existing standby energy sources and the rapid development of technology, especially in the electronic and semiconductor field, the authors determined that in order to provide the backup power to the first category consumers of power supply, which include fire protection system, the optimal solution would be to use rechargeable batteries with autonomous voltage inverters. Methodology: The authors carried out the quantitative analysis of transmission power lines failures and power blackouts in settlements. With the use ofthe modelling theory of systems the authors designed a mathematical model for backup power from batteries with standby voltage inverters for the internal fire protection water supply system. The adequacy of the model was proved by the experiments carried out at the experimental stand. Conclusions: The discussed method of providing backup power to fire protection water supply system with the use of batteries and standalone voltage converters provides necessary parameters for the estimated time required for the arrival of fire operational units. What is more, the method enables to switch on the system more quickly in comparison to other power sources in the conditions of adverse weather. Moreover, it does not require retrofitting of existing and already used systems or special operating conditions, thus the efficiency of the system is improved by about 150 percent.
Cel: W artykule omówiono kwestię efektywności pracy wewnętrznej instalacji wodociągowej przeciwpożarowej w obiektach turystycznych z punktu widzenia jej zasilania w różnych sytuacjach i warunkach pracy, a także zaproponowano możliwe rozwiązania w tym zakresie. Wprowadzenie: Rozwój gałęzi turystycznej w państwie związany z organizacją różnego rodzaju przedsięwzięć o charakterze międzynarodowym przyczynił się do intensywnego budownictwa i rekonstrukcji obiektów mających na celu zapewnienie turystom komfortowych warunków pobytu. Dlatego też wiele obiektów zlokalizowanych jest w malowniczych punktach z dala od obszarów zamieszkanych. Takie budynki mają mniejsze możliwości korzystania określonych zasobów takich jak elektryczność, woda, komunikacja. Aby ochronić ludzi oraz ich majątki przed skutkami pożaru, konieczne jest zapewnienie regularnej dostawy energii elektrycznej do systemów ochrony przeciwpożarowej w tym wewnętrznej instalacji wodociągowej przeciwpożarowej. Analizując wykorzystywane dziś autonomiczne źródła zasilające oraz biorąc pod uwagę szybki rozwój techniki, szczególnie w sferze elektroniki i półprzewodników, ustalono, że do zapewnienia zasilania rezerwowego, zgodnie z dokumentami regulacyjnymi – użytkownikom systemów ochrony przeciwpożarowej pierwszej kategorii, optymalnym rozwiązaniem będzie wykorzystanie baterii akumulatorowych w zestawie z autonomicznymi przetwornikami napięcia. Metodologia: W procesie opracowywania artykułu przeprowadzono analizę ilościową przypadków wyłączenia sieci wysokiego napięcia i odcięcia energii na obszarach zamieszkanych. Opracowano model matematyczny rezerwowego źródła zasilania z akumulatorowych baterii z autonomicznymi przetwornikami napięcia dla wewnętrznej instalacji wodociągowej przeciwpożarowej, wykorzystując teorię modelowania systemów. W celu potwierdzenia słuszności modelu i przeprowadzenia eksperymentów opracowano i wykorzystano stanowisko eksperymentalne. Wnioski: Przedstawiony sposób zapewnienia rezerwowych źródeł zasilania instalacji wodociągowej przeciwpożarowej przy pomocy baterii akumulatorowych i autonomicznych przetworników napięcia zapewnia niezbędne parametry energii elektrycznej w obliczonym czasie do przybycia jednostek ratowniczo-gaśniczych oraz pozwala na szybszą aktywację systemów w porównaniu z innymi źródłami zasilania przy niesprzyjających warunkach pogodowych. Co więcej, metoda ta nie wymaga modernizacji funkcjonujących i używanych systemów, a także szczególnych warunków użytkowania. Proponowane rozwiązanie zwiększa efektywność zasilanego systemu półtorakrotnie.
Źródło:
Bezpieczeństwo i Technika Pożarnicza; 2014, 1; 59-66
1895-8443
Pojawia się w:
Bezpieczeństwo i Technika Pożarnicza
Dostawca treści:
Biblioteka Nauki
Artykuł
    Wyświetlanie 1-4 z 4

    Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies